At least 217 records · Page 12

Wholesale Electricity Analysis via Simulation & Learning Experiments (WEASLE): Platform Development and Pilot Competition

This document reports the development of the Wholesale Electricity Analysis via Simulation and Learning Experiments (WEASLE) platform and the pilot competition that was conducted to test the platform. Due to the increasing reliance on variable renewable energy resources for bulk power, the pilot competition, called the Energy Storage Participation Algorithm Competition (ESPA-Comp), was used to test the effect of various market designs on storage utilization and market efficiency. Basic details of the platform are provided, including an overview of the market clearing engine, the battery dispatch and degradation models, electric grid topology and resource mix, and software architecture. Two market designs were tested: a two-settlement market analogous to typical ISO design today, and a multi-settlement market that allows additional forward-trading periods during the real-time market. Results from the pilot competition show that the storage bidding problem is nontrivial and is well suited for future challenges. We find that: 1) all four teams utilized different approaches to the bidding problem, 2) different methodological approaches led to substantially different offer behaviors, 3) resource profits are clustered by team and methodological approach, 4) simulated offers reduced market surplus by about 0.5%, 5) substantially different prices between two-settlement and multi-settlement markets albeit minimal difference in overall market surplus.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of hydrophobic physical solvents for pre-combustion CO 2 capture at a pilot scale coal gasification facility

Here, in this paper, we present the first pilot plant data for hydrophobic physical solvents for CO 2 and H 2 S removal from coal-derived H 2 -rich syngas. Four physical solvents were tested under pre-combustion CO 2 capture conditions at bench scale and pilot plant scale: one baseline hydrophilic solvent and three hydrophobic solvents. The solvents were: (1) polyethylene-glycol-dimethyl ether (PEGDME), a hydrophilic solvent analog for the commercial process Selexol, (2) tributyl- phosphate (TBP), a commercially available hydrophobic solvent, (3) polyethylene glycol-poly(dimethylsiloxane) (PEG-PDMS-3), and (4) diethyl sebacate (CASSH-1), a novel, computationally screened hydrophobic solvent developed by the National Energy Technology Laboratory (NETL). All solvents were studied under pure gas (CO 2 /N 2 /H 2 /CH 4 ) equilibrium conditions at NETL followed by pilot plant testing with syngas at the University of North Dakota Energy & Environmental Research Center (UND EERC). Long term performance of CASSH-1 and PEDGME was then assessed with results compared to process simulation predictions. Within experimental uncertainties, all solvents showed comparable CO 2 absorption performance at above room temperature operation while the hydrophobic solvents had limited water uptake and low vapor pressure, which alleviates concerns related to corrosion, water absorption, and solvent loss to evaporation. These results indicate low viscosity, low vapor pressure hydrophobic solvents are a promising option for lower cost CO 2 capture from high pressure syngas applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying Candidate Biomarkers of Ionizing Radiation in Human Pulmonary Microvascular Lumens Using Microfluidics—A Pilot Study

The microvasculature system is critical for the delivery and removal of key nutrients and waste products and is significantly damaged by ionizing radiation. Single-cell capillaries and microvasculature structures are the primary cause of circulatory dysfunction, one that results in morbidities leading to progressive tissue and organ failure and premature death. Identifying tissue-specific biomarkers that are predictive of the extent of tissue and organ damage will aid in developing medical countermeasures for treating individuals exposed to ionizing radiation. In this pilot study, we developed and tested a 17 µL human-derived microvascular microfluidic lumen for identifying candidate biomarkers of ionizing radiation exposure. Through mass-spectrometry-based proteomics, we detected 35 proteins that may be candidate early biomarkers of ionizing radiation exposure. This pilot study demonstrates the feasibility of using humanized microfluidic and organ-on-a-chip systems for biomarker discovery studies. A more elaborate study of sufficient statistical power is needed to identify candidate biomarkers and test medical countermeasures of ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

MODELING AND TESTING OF A NOVEL ULTRA-LOW TEMPERATURE SCO2 OPPOSING PISTON EXPANDER

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

01 COAL, LIGNITE, AND PEAT↗

2020 LANL Contributions to the BATS Test in WIPP

The DOE Office of Nuclear Energy (DOE-NE) repository research and development program seeks to provide a sound technical basis for multiple viable disposal options, increase confidence in the robustness of generic disposal concepts, and develop science and engineering tools needed to support disposal concept implementation. Sandia, Los Alamos, and Lawrence Berkeley National labs are conducting research into salt, which includes the Brine Availability Test in Salt (BATS) field test at the Waste Isolation Pilot Plant (WIPP), a DOE Office of Environmental Management facility. BATS is leveraging the existing infrastructure associated with the WIPP to advance science informing generic disposal concepts. BATS is an ongoing heated borehole experiment being conducted in the WIPP underground. The goal of this experiment is to reduce the uncertainty associated with spent nuclear fuel disposition in geologic salt formations. The BATS experiments is designed to accomplish this by increasing our understanding of brine migration in salt, assessing damaged zones from mining and drilling, simulating a post-closure environment, confirming salt properties, and providing data for model validation. Phased testing for generic salt repository R&D was proposed in 2015. Subsequently, borehole thermal testing was developed as a first step in this process. This document summarizes the work conducted on the BATS experiment during fiscal year 2020 with an emphasis on the contributions by Los Alamos National Lab.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

The advanced tokamak path to a compact net electric fusion pilot plant

Abstract Physics-based simulations project a compact net electric fusion pilot plant with a nuclear testing mission is possible at modest scale based on the advanced tokamak concept, and identify key parameters for its optimization. These utilize a new integrated 1.5D core-edge approach for whole device modeling to predict performance by self-consistently applying transport, pedestal and current drive models to converge fully non-inductive stationary solutions, predicting profiles and energy confinement for a given density. This physics-based approach leads to new insights and understanding of reactor optimization. In particular, the levering role of high plasma density is identified, which raises fusion performance and self-driven ‘bootstrap currents’, to reduce current drive demands and enable high pressure with net electricity at a compact scale. Solutions at 6–7 T, ∼4 m radius and 200 MW net electricity are identified with margins and trade-offs possible between parameters. Current drive comes from neutral beam and ultra-high harmonic (helicon) fast wave, though other advanced approaches are not ruled out. The resulting low recirculating power in a double null configuration leads to a divertor heat flux challenge that is comparable to ITER, though reactor solutions may require more dissipation. Strong H-mode access (x2 margin over L–H transition scalings) and ITER-like heat fluxes are maintained with ∼20%–60% core radiation, though effects on confinement need further analysis. Neutron wall loadings appear tolerable. The approach would benefit from high temperature superconductors, as higher fields would increase performance margins while potential for demountability may facilitate nuclear testing. However, solutions are possible with conventional superconductors. An advanced load sharing and reactive bucking approach in the device centerpost region provides improved mechanical stress handling. The prospect of an affordable test device which could close the loop on net-electric production and conduct essential nuclear materials and breeding research is compelling, motivating research to validate the techniques and models employed here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D high-fidelity automated neutronics guided optimization of fusion blanket designs

The compact Fusion Pilot Plant (FPP) is defined in the recent National Academies of Sciences, Engineering, and Medicine report as the next step of fusion energy demonstration with a $50$ MWe peak net electricity production, $Q_e$ greater than $1$, and at least $3$ hours of continuous operation. This fusion pilot plant will be a test bed enabling materials, designs, and fuel management assessment, and it will represent an engineering challenge because of its high-fusion power and compact design targets. Previous reactor data is limited to experiments operating in different design space ranges. Therefore, design iterations and assessments should rely on high-fidelity first-principle theoretical and computational models. The high-fidelity integrated modeling of the plasma is a fundamental part of fusion energy research. However, the whole device modeling is often neglected, utilizing low-fidelity, system-level analysis. Recently, the need for high-fidelity multi-physics modeling was recognized, resulting in a selection of integrated tools. Further, autonomous design optimization requires a streamlined framework that perturbs the design point, reruns the analysis, and examines the outputs. However, high-fidelity analysis requires complex geometry specification that is difficult to perturb. This work presents the parametric CAD generation tool TRACER and a new neutronic workflow. TRACER allows the perturbation of the geometry representation, creating geometry files ready for further analysis. The streamlined neutronic workflow allows efficient and accurate calculations. The two new tools coupled together were used to perform a 3D high-fidelity multi-objective, multi-input optimization of an "ARC Class" compact tokamak design. The workflow was driven by an optimization driver for full automation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of air-fuel equivalence ratio effects on advanced dual-fuel ammonia/diesel combustion on a single-cylinder medium-duty diesel engine at high load

Ammonia (NH 3 ) has garnered significant interest as an alternative fuel for meeting international emissions reduction mandates in sectors with high weight and distance requirements, such as shipping. Technical barriers and unanswered questions remain on the combustion strategies that can maximize ammonia utilization and minimize emissions. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH 3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH 3 combustion performance at richer in-cylinder conditions, a global λ sweep compared the use of early (E-pilot) and late (L-pilot) single diesel injections. The experiments were conducted at 1200 RPM and 12.8 ± 0.2 bar (75 % load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90 % ammonia energy substitution level. A diesel injection timing sweep was conducted for both the injection strategies at fixed λ, and the timing with the lowest engine-out N 2 O emissions was identified. The results indicated an optimal balance between CO 2,eq and thermal efficiency benefits both E-pilot and l-pilot injection strategy cases compared with CDC at a λ of 1.4. In conclusion, the indicated nitrogen-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for l-pilot, but no apparent trend emerged for the E-pilot injection strategy at the tested boundary conditions.

Ammonia↗

The SMART Cables Initiative for Ocean and Geophysical Observing [Slides]

SMART Cables are becoming a reality, and have the potential to revolutionize submarine oceanographic and geophysical sensing. Pilot / demonstration projects are underway to test the technology and explore the feasibility of incorporating both in-repeater standardized sensor packets but also ancillary sensor types on external, branching nodes. The projects currently in planning will set the standard and influence the norms for the future of SMART systems. The interest of all potential stakeholders and users, and input as to needs and concerns, is welcomed as testing proceeds.

54 ENVIRONMENTAL SCIENCES↗

An Applied Strategy for Using Empirical and Hybrid Models in Online Monitoring

The monitoring of plant equipment for failure prediction is one of the key contributors to operation and maintenance (O&M) costs for a nuclear power plant (NPP) because O&M monitoring depends on labor-intensive activities that are required to meet high equipment reliability standards. These activities rely primarily on humans for information gathering, condition diagnosis, and predictive analysis. Online monitoring aims to automate these activities by relying on sensors to replace human information gathering and machine learning to replace human analysis and decision making. To facilitate automated monitoring, a systematic strategy for anomaly detection is needed to optimally use the available sensor data, empirical models, and physics-supported models. This strategy is essential to provide credible reasoning on why and when an empirical (i.e., purely data-driven) versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. The extant methods usually adopt an ad hoc trial-and-error approach that, in addition to being time-consuming and costly, is also highly subjective; it is impacted by the background and the skill set of the personnel making the decisions. Thus, such an approach cannot guarantee an optimum outcome. This represents the motivation of the current research effort, which is focused on devising a scientifically supported strategy for the optimum selection of anomaly detection methods. This report presents a detailed assessment of the main anomaly detection techniques within the empirical or hybrid method streams. Empirical methods include pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The listed techniques within these two streams represent the vast majority of techniques performed for anomaly detection. Using the techniques as outcomes, a strategy was developed to enable a systematic decision-making process to lead to one of these techniques. The strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability and suitability for training and testing, cause-effect, entropy inference, and model fitting. Each of these decision points in the strategy is explained in detail in this report with examples, along with the scientific basis behind the decisions and outcomes in common and simplified terminology. The strategy is developed for use by any NPP staff with basic engineering or science knowledge. A user-friendly graphical state flow diagram was also developed as a visual presentation of the strategy. The strategy was tested and demonstrated through two pilot projects for the application of anomaly detection at an NPP. Each pilot had two use cases: an initial case in which certain decisions were made that resulted in one or more empirical techniques and a revised use case where one or more key decisions were modified resulting in using a set of hybrid methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Advanced Scale Up Reactor Experiment (ASURE) Facility: A Testbed for Advancing the Art of Biomass and Waste Co-Gasification Systems

Powerpoint slides for an oral presentation at the 2024 Clearwater Clean Energy conference. It includes a brief discussion of the plans to construct a small pilot-scale co-gasification test facility known as the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL’s Morgantown, WV site in support of FECM’s goals for advancing biomass and waste co-gasification systems for carbon-neutral hydrogen production.

Rowan, Steven↗

Foam and Unreacted Material Reduction in Magnesium Oxysulfate for SRPPF Waste Solidification

A magnesium oxysulfate (MOS) grout formulation has been proposed to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). This formulation uses a combination of light-burnt MgO, anhydrous MgSO 4 , and dead-burnt MgO resulting in a grout with good mixability and acceptable density. The setting time for the grout is within the operational limits of the SRPPF facility and the leachate pH is ~9.4, which is within the assumed pH range of the brine from the Waste Isolation Pilot Plant (WIPP). When first tested at the 1-gallon small-scale and 55-gallon full-scale, there was a significant foam layer that raised concerns of a nonhomogeneous final form. A nonhomogeneous mixture could have variable density throughout the waste form and therefore allow for unequal shielding. To reduce the potential for unequal shielding in the final form, a series of foam reduction tests were carried out and a final formulation of 28 wt% light burnt MgO, 10 wt% MgSO 4 , and 62 wt% dead burnt MgO was used to remove the foam in under two hours while still maintaining a mix that has an acceptable density, mix time, peak temperature, and set time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Advanced Scale Up Reactor Experiment (ASURE) Facility: A Testbed for Advancing the Art of Biomass and Waste Co-Gasification Systems.

This paper was an executive summary for an oral presentation to be included in the conference proceedings of the 2024 Clearwater Clean Energy conference. It includes a brief discussion of the plans to construct a small pilot-scale co-gasification test facility known as the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL’s Morgantown, WV site in support of FECM’s goals for advancing biomass and waste co-gasification systems for carbon-neutral hydrogen production.

Rowan, Steven↗

A Handbook for Designing, Implementing, and Evaluating Successful Electric Utility Pilots

Since at least the late 1970s, electric utilities and their regulators have recognized the value of experimentation to motivate innovation. The industry has a long history of using pilots to help inform future decision making about electric utility rates, customer technology adoption and integration, and even changes to the utility’s regulatory or business model. Although utility pilots have become almost ubiquitous proving grounds for new rates, technologies, and alterations to the traditional utility regulatory and business model, some regulators are beginning to raise questions about what constitutes a “good” pilot. Much has been written about utility pilots over the years; however, what is missing from the literature is the identification of a comprehensive process for not only designing and evaluating a pilot, but also implementing, successful utility pilots that provide actionable outcomes upon which more informed decisions can be made. This report provides a step-by-step process that regulators, policymakers, and utilities can follow to help promote a more successful pilot, even if whatever is being tested fails to produce the intended or expected result(s). It is worth noting that this report is not intended to serve as a technical resource for those designing, implementing, and evaluating pilots. However, there are myriad references provided for those wishing to delve deeper into the technical details.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Summary of the Brine Availability Test in Salt (BATS), Including Extended Plan for Experiments at the Waste Isolation Pilot Plant (WIPP)

This document lays out a set of near-future investigations in salt, the third phase of BATS (BATS 3). This phase is planned to answer the few remaining issues from the first two phases of BATS (BATS 1 and BATS 2), and to prepare for a subsequent large-scale demonstration phase. The BATS experiments are the first part of a larger plan to conduct field experiments to answer specific technical questions, improve the technical basis for disposal of heat-generating radioactive waste in salt (Stauffer et al., 2015; SNL et al., 2020), and demonstrate readiness for disposal of radioactive waste in salt, including large, hot waste packages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗