Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature checks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Shuttle era - A challenge to the earth scientist

Satellite observations of large-scale earth features and phenomena, with either instruments or astronauts, are discussed on the basis of earlier experience (mainly Skylab). Off-nadir views and photographs by astronauts have provided valuable supplements to instrument nadir views, providing cross-checks through remote sensing at different angles, different altitudes, and in different seasons. New information on plate tectonics, global cooling/drying trends, global oceanographic data (changing positions of major ocean current patterns, evolution of warm and cold eddies and their relation to sea temperatures and concentrations of marine fauna, location of internal sea waves, interactions between ocean currents and atmosphere, plankton blooms), storm development, snow cover patterns, lake and sea ice growth, sand-dune patterns, desert storms blown out to sea, effects of grazing and swidden agriculture, and other earth features and phenomena are surveyed.

Muehlberger, W. R.↗

DC Performance Testing of MgB2 Superconducting Straight Wire Samples

To enable turboelectric aircraft that utilize fully superconducting motors and generators, testing of high-current, low-AC-loss superconducting wires and coils must be performed. A preliminary investigation was conducted on the critical current capabilityof a magnesium diboride sample and on the complications that arise from testing the sample with a cryocooler. While a cryocooler provides the benefit of a wide and continuous operating temperature range, cooling a sample by conduction through solid media without a heat-exchange gas is difficult. This paper outlines the hardware and software used to conduct the first DC performance tests on magnesium diboride superconducting samples, along with several check-out tests and mitigation steps needed to produce quality superconducting data using a cryocooler rather than a cryogen

Superconductor↗

Laser speckle technique for burner liner strain measurements

Thermal and mechanical strains were measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnance. The physical geometry of the sample surface was recorded at selected temperatures by a set of 12 single exposure speckle-grams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which give high precision measurement of differential displacements. Good speckle correlation between the first and last specklegrams is noted which allows a check on accumulate errors.

Stetson, K. A.↗

Investigative techniques used to locate the liquid hydrogen leakage on the Space Shuttle Main Propulsion System

Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.

Hammock, William R., Jr.↗

The Cross Correlation of the ABS and ACT Maps

One of the most important checks for systematic errors in CMB studies is the cross correlation of maps made by independent experiments. In this paper, we report on the cross correlation between maps from the Atacama B-mode Search (ABS) and Atacama Cosmology Telescope (ACT) experiments in both temperature and polarization. These completely different measurements have a clear correlation with each other and with the Planck satellite in both the EE and TE spectra at l < 400 over the roughly 1100 deg(exp 2) common to all three. The TB, EB, and BB cross spectra are consistent with noise. Exploiting such cross-correlations will be important for future experiments operating in Chile that aim to probe the 30 < l < 8,000 range.

CMBR experiments↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: METSAT Phase Locked Oscillator Assembly, P/N 1334360-1, S/N's F03 and F04

Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.

Pines, D.↗

CO2 Insulation for Thermal Control of the Mars Science Laboratory

The National Aeronautics and Space Administration (NASA) is sending a large (>850 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars in 2011. The rover's primary power source is a Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) that generates roughly 2000 W of heat, which is converted to approximately 110 W of electrical power for use by the rover electronics, science instruments, and mechanism-actuators. The large rover size and extreme thermal environments (cold and hot) for which the rover is designed for led to a sophisticated thermal control system to keep it within allowable temperature limits. The pre-existing Martian atmosphere of low thermal conductivity CO2 gas (8 Torr) is used to thermally protect the rover and its components from the extremely cold Martian environment (temperatures as low as -130 deg C). Conventional vacuum based insulation like Multi Layer Insulation (MLI) is not effective in a gaseous atmosphere, so engineered gaps between the warm rover internal components and the cold rover external structure were employed to implement this thermal isolation. Large gaps would lead to more thermal isolation, but would also require more of the precious volume available within the rover. Therefore, a balance of the degree of thermal isolation achieved vs. the volume of rover utilized is required to reach an acceptable design. The temperature differences between the controlled components and the rover structure vary from location to location so each gap has to be evaluated on a case-by-case basis to arrive at an optimal thickness. For every configuration and temperature difference, there is a critical thickness below which the heat transfer mechanism is dominated by simple gaseous thermal conduction. For larger gaps, the mechanism is dominated by natural convection. In general, convection leads to a poorer level of thermal isolation as compared to conduction. All these considerations play important roles in the optimization process. A three-step process was utilized to design this insulation. The first step is to come up with a simple, textbook based, closed-form equation assessment of gap thickness vs. resultant thermal isolation achieved. The second step is a more sophisticated numerical assessment using Computational Fluid Dynamics (CFD) software to investigate the effect of complicated geometries and temperature contours along them to arrive at the effective thermal isolation in a CO2 atmosphere. The third step is to test samples of representative geometries in a CO2 filled chamber to measure the thermal isolation achieved. The results of these assessments along with the consistency checks across these methods leads to the formulation of design-guidelines for gap implementation within the rover geometry. Finally, based on the geometric and functional constraints within the real rover system, a detailed design that accommodates all these factors is arrived at. This paper will describe in detail this entire process, the results of these assessments and the final design that was implemented.

CO2↗

Identification and Study of Validation Level Test Cases for Computational Modeling of Non-Charring Ablators

Computational modeling of Thermal Protection System (TPS) materials, used for aerospace applications, provides numerous advantages in preliminary selection and design of a heatshield material and shape for atmospheric entry vehicles. However, to serve as a reliable tool for prediction of material thermal and ablative behavior, the modeling approach needs to be validated against real experimental and flight data, preferably at a range of applied conditions. The validation study is typically very complex as it requires reliable measured data not only for the material thermal response and surface recession, but also well characterized environmental conditions. The validation problem becomes even more complex when the material thermal response is dictated by multi-physics effects such as solid conduction, in-depth thermal decomposition, pyrolysis gas flow and chemical reactions. The multi-physics effects complicate not only the modeling effort, but also the experimental measurement for validation of various aspects of the highly coupled problem. In this study, an attempt is made to identify suitable experimental data that could serve as a source for validation of material thermal response modeling tools. To reduce the computational complexity, this study focuses only on non-charring ablators, where the material thermal response could be modeled with a single governing equation for solid conduction and the ablation is limited only to the surface of the material. With a well characterized and publicly available experimental data being sparse, the study is limited in presenting test cases for only three materials: camphor, graphite and FiberForm® in the sequence of increased modeling complexity. Graphite is a commonly used TPS material for aerospace applications, both for leading edges of high-speed vehicles and internal insulation of solid rocket motors. FiberForm® is a porous carbon pre-form used in preparation of the well known PICA material Tran et al. [1996]. Inclusion of camphor into the list is conditioned with the relative simplicity in modeling the material thermal and chemical response and the low-enthalpy flow environment. In addition, camphor has been used as a simple test material for study of flow transition behavior by Stock and Ginoux [1973] and assessment of a heatshield shape change at flight relevant conditions by Rotondi et al. [2022]. In this work, the identified experimental data was extracted from the public literature and test cases that yet have been published. As it was found from the review, not a single test case contains an exhaustive set of data that would validate every aspect of the material physics. However, in the data collected, various aspects of the material behavior can be still validated, such as surface and in-depth temperature, amount of recession and a shape change. The identified experimental data for each case is accompanied with a characterized flow environment and simulated boundary conditions predicted by a Data-Parallel Line Relaxation (DPLR) code Wright et al. [1998]. In addition, material thermal response numerical simulations in each test case are performed with Kentucky Aerothermodynamics and Thermal Response System (KATS-MR) Zibitsker et al. [2022] providing a comparative study and a sanity check for the proposed validation data. Sample results from the performed numerical study are shown below. Figure 1 shows distribution of surface heat flux and pressure values on a hemi-cylinder model made of FiberForm® and tested in HyMETS arc-jet facility. The results are shown for the high pressure condition among the two tests. Flow simulation was performed with DPLR code on a quarter of original geometry. In the figure, the quarter shape was mirrored across zx and xy planes to show the complete distribution. Figure 2 shows the material response results for the high pressure case (7500 Pa), simulated with KATS-MR and a comparison to the experimental data for the surface temperature and shape shape. The simulation was performed on a 2-D slice, extracted in the xy plane at the middle of the sample. Figure 3 shows the material response simulation for the low pressure case (3500 Pa) and a comparison to the experimental data for surface temperature and shape change.

ablation↗

Determination of elastic stresses in gas-turbine disks

A method is presented for the calculation of elastic stresses in symmetrical disks typical of those of a high-temperature gas turbine. The method is essentially a finite-difference solution of the equilibrium and compatibility equations for elastic stresses in a symmetrical disk. Account can be taken of point-to-point variations in disk thickness, in temperature, in elastic modulus, in coefficient of thermal expansion, in material density, and in Poisson's ratio. No numerical integration or trial-and-error procedures are involved and the computations can be performed in rapid and routine fashion by nontechnical computers with little engineering supervision. Checks on problems for which exact mathematical solutions are known indicate that the method yields results of high accuracy. Illustrative examples are presented to show the manner of treating solid disks, disks with central holes, and disks constructed either of a single material or two or more welded materials. The effect of shrink fitting is taken into account by a very simple device.

Manson, S S↗

Computation of Jupiter interior models from gravitational inversion theory

Spacecraft measurements of Jupiter have provided the mass, standard pressure level radius, rotation law, internal mass distribution multipole moments, and internal composition and temperature distribution constraints, for the present implementation of a method for deriving planetary interior models that exactly satisfy a set of N gravitational constraints by means of appropriate iteration. The models are not forced to fit the more indirectly derived constraints, which are instead used as conistency checks. In the case of an He mass fraction in the envelope Y of 0.2, the inferred pressure at a mass density of about 0.2 g/cu cm is about a factor of 2 higher than would be indicated by experimental H compression data in the relevant pressure range of 100,000 to one million bar. The inferred pressure distribution is in better agreement with the shock data for a nominal Y value of 0.3 + or - 0.05.

Hubbard, W. B.↗

Modified Newtonian dynamics and the Coma cluster

The consistency of Milgrom's theory of modified Newtonian dynamics is checked against optical and X-ray data for the Coma cluster of galaxies. It is found that viable models for the cluster containing no dark matter can be constructed. They require an extensive gaseous atmosphere through which galaxies move on near-radial orbits. The gas temperature is predicted to have a shallow minimum near the cluster center; this structure may conflict with the best X-ray spectra of the cluster.

The, Lih Sin↗

Calculation of Internal Pressures in the Fuel Tube of a Nuclear Reactor

General procedures for computing internal pressures in fuel tubes of nuclear reactors are described and the effects on the pressure of varying neutron flux, fissioning material, and operating temperatures are discussed. A general proof is given that during pile operation each fission product is monotonically increasing and therefore a maximum amount of all elements is present at the time of shit down. The post-shutdown build-up of elements that are held in check during pile operation because of their inordinately high capture cross sections is calculated quantitatively. An account of chemical interactions between the many fission-product elements and the resulting effect on the total pressure completes the discussion. The general methods are illustrated by calculations applied to a system consisting of 90 percent enriched U235 in the form of UO2 packed into a hollow metal cylinder or "pin", operating at a flux of 8 x 10(exp 14) at 2000 F. Calculations of the pressure inside a pin are made with and without a sodium metal heat-transfer additive. The bulk of the pressure is shown to depend on the four elements, xenon, krypton, rubidium, and cesium; the amount of free oxygen, however, was also significant. For a shutdown time of 10(exp 6) seconds, the pressure was about 100 atmospheres.

Rosenbaum, B. M.↗

Laser application to measure vertical sea temperature and turbidity, design phase

An experiment to test a new method was designed, using backscattered radiation from a laser beam to measure oceanographic parameters in a fraction of a second. Tyndall, Rayleigh, Brillouin, and Raman scattering all are utilized to evaluate the parameters. A beam from a continuous argon ion laser is used together with an interferometer and interference filters to gather the information. The results are checked by direct measurements. Future shipboard and airborne experiments are described.

Hirschberg, J. G.↗

Characterization of the Heat Extraction Capability of a Compliant, Sliding, Thermal Interface for Use in a High Temperature, Vacuum Microgravity Furnace

Much of the material science gained in microgravity research requires processing a sample in a high performance furnace. One such furnace currently being designed is the Quench Module Insert (QMI). The Principle Investigators, for whom the furnace is proposed, require high temperature gradients in their cylindrical samples to achieve the science objectives. One of the components critical to achieving high sample axial temperature gradients in the Quench Module Insert is a high performance cold zone to extract the heat from the sample. This cold zone employs a compliant, sliding thermal interface based on a Vel-Therm felt. This felt provides a conductive path between the Sample Cartridge Assembly (SCA) exterior surface and the interior surface of the water cooled chill block while allowing movement of the sample relative to the chill block. The Vel-Therm felt is composed of long polymer-based fibers affixed to a thin flexible substrate layer. The fibers are oriented perpendicular to this substrate giving the felt the appearance of a velvet fabric. The Vel-Therm felt heat extraction capability was quantified in earlier tests performed in an inert gas environment. The current activity, described in this paper, is intended to characterize the extraction capability of Vel-Therm felt in a vacuum environment similar to the QMI environment. This testing is necessary to quantify the thermal performance of the Vel-Therm felt and the sensitivity of that performance to key variables. The data derived from these tests will be incorporated into the current thermal models to improve the quality of the models and reduce uncertainty of the analytical results. In addition, the data will be used to help select the appropriate Vel-Therm felt and set proper operating limits as well as assess the performance range of the furnace. The objective of this test is to measure the heat extraction rate of the Vel-Therm felt as specified by the effective heat transfer coefficient. Therefore, the test setup was designed to force the bulk of the heat transfer through the area where the Vel-Therm felt was applied. A heat source, consisting of a ceramic heating element encased in a Copper (Cu) housing is mounted on four isolated support rods. A 6-layer molybdenum radiation shield is used to insulate against heat loss from the heater and prevent heat exchange between the hot and cold sides of the test apparatus. The Vel-Therm felt is affixed to the surface of the cold sink, a water-cooled Cu chill block. An adjustable plate supports and isolates the cold sink from above and is used to control the amount of the deflection of the Vel- Therm when in contact with the Cu heating element housing. The primary means of establishing the power being conducted through the felt is to measure the energy being transferred to the water passing through the chill block. Analysis was performed to support the assumption that the source and sink surfaces were approximately isothermal under the specific test conditions. As a check on the amount of power passing through the felt, the power supplied to the heater was also measured. Thermocouples were strategically located throughout the test apparatus for measurement purposes. A bell jar was lowered over the assembly to impose vacuum conditions. Currently, variables tested have been fiber compression and fiber type and surface temperatures (both the hot and cold side temperatures are hypothesized to be important to the performance of the Vel-Therm.) Selected runs were repeated to ensure consistency and repeatability. Results obtained thus far reveal that Vel-Therm performance is significantly degraded by fibers being exposed to high compression. It also shows that performance is somewhat negatively impacted by previous compression, thereby, raising the question of repeatability. In addition, early results show a significant dependence on temperature. A computer aided mathematical analysis of the test setup is ongoing. The results will be correlated to actual results. The correlation will examine such details as parasitic loses, conduction down the power leads and many other concerns.

Bellomy-Ezell, Jenny↗

Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Calibration System

As a continuing effort to increase the calibration accuracy of the AVIRIS data a number of recent improvements have been implemented and are in the process of being tested during the 1994 flight season. These include the following innovations: A direct observation of a laboratory radiance standard is now used to double check the wide field-of-view calibration via an integrating sphere source. Launch site field calibration of the AVIRIS sensor is now being planned to augment the laboratory and inflight calibration. Modification to a dry air conditioning unit has been made to enable ground calibration at flight operating temperatures. One hundred lines of dark imagery has been added to the end of each flight line to assist in the analysis and removal of residual coherent noise. The intensity of the onboard calibration lamp has been modified to improve response in the blue end of the spectrum. Novel spectral filters have been installed in the onboard calibration source.

Airborne Visible/Infrared Imaging Spectrometer Cal↗

Recent Checks on the Radiometric and Spatial Calibration of AIRS In-Orbit

The Atmospheric Infrared Sounder (AIRS) on the EOS Aqua Spacecraft was launched on May 4, 2002 and is currently fully operational. AIRS acquires hyperspectral infrared radiances in 2378 channels ranging in wavelength from 3.7-15.4 um with spectral resolution of better than 1200, and spatial resolution of 13.5 km with global daily coverage. The AIRS was designed to measure temperature and water vapor profiles for improvement in weather forecast and improved parameterization of climate processes. Currently the AIRS Level 1B Radiance Products are assimilated by NWP centers worldwide and have shown considerable forecast improvement. Although the calibration of AIRS (< 200 mK 3 sigma) is sufficient for data assimilation into Numerical Weather Prediction (NWP) models, long term trends of Earth’s climate require radiances with stability approaching 10 mK/year, and absolute accuracies better than 100 mK. This investigation uses views of space during roll maneuvers of the Aqua spacecraft to calibrate the mirror emission (one of the largest error sources for AIRS) and reduce the residual errors in cold scenes. We also present results of a secondary study that uses MODIS data to determine the alignment of the AIRS boresight. In this study we match AIRS and MODIS data and iterate on the assumed boresight to find the minimum difference in signal. In this way we are able to confirm the boresight projections determined shortly after launch.

Pagano, Thomas S.↗

Scaled centrifugal compressor, collector and running gear program

The Scaled Centrifugal Compressor, Collector and Running gear Program was conducted in support of an overall NASA strategy to improve small-compressor performance, durability, and reliability while reducing initial and life-cycle costs. Accordingly, Garrett designed and provided a test rig, gearbox coupling, and facility collector for a new NASA facility, and provided a scaled model of an existing, high-performance impeller for evaluation scaling effects on aerodynamic performance and for obtaining other performance data. Test-rig shafting was designed to operate smoothly throughout a speed range up to 60,000 rpm. Pressurized components were designed to operate at pressures up to 300 psia and at temperatures to 1000 F. Nonrotating components were designed to provide a margin-of-safety of 0.05 or greater; rotating components, for a margin-of-safety based on allowable yield and ultimate strengths. Design activities were supported by complete design analysis, and the finished hardware was subjected to check-runs to confirm proper operation. The test rig will support a wide range of compressor tests and evaluations.

Kenehan, J. G.↗

Ames Research Center Mars/Pathfinder Heat Shield Design Verification ARC-JET Test

Design verification tests were performed on samples representing the aerobrake of the Mars/Pathfinder vehicle. The test specimens consisted of the SLA-561V ablator bonded to the honeycomb structure. The primary objective was to evaluate the ablation materials performance and to measure temperatures within the ablator, at the structural bondline and at the back sheet of the honeycomb structure. Other objectives were to evaluate the effect of ablative repair plug material treatment and voids in the heat shield. A total of 29 models were provided for testing in the Ames 60MW arc-jet facility. Of these, 23 models were flat-faced and six remaining models were curved edge ones, intended to simulate the conditions on the curved rim of the forebody where the maximum shear occurred. Eight sets of test conditions were used. The stagnation point heating rates varied from 47 to 240 W/cm2 and the stagnation pressures from 0.15 to 0.27 atm. (The maximum flight values are 132 W/cm2 and 0.25 atm) The majority of these runs were made at a nominal stagnation pressure of 0.25 atm. Two higher pressure runs were made to check the current (denser) ablation material for spallation, or other forms of thermal stress failure. Over 60% of the flatfaced models yielded good thermocouple data and all produced useful surface recession information. Of the five curved-edge models that were tested, only one gave good data; the remaining ones experienced model-holder failure. The test results can be summarized by noting that no failure of the ablative material was observed on any model. Also, the bondline temperature design limit of 250 C was never reached within an equivalent flight time despite a stagnation point heat load that exceeded the maximum flight value by up to 130%. At heating rates of over 200W/cm2 and stagnation pressures of 0.25 atm, or greater, the average surface recessions exceeded 0.5 cm on some models. The surface roughness increased dramatically at pressures above 0.25 atm and was four times greater at 0.27 atm than at 0.25 atm. Procured repair plug material performed much better than room-temperature cured plugs, as observed in the previous tests. Voids in the ablator did not increase local temperatures and gaps did not grow during testing.

Tran, Huy K.↗