Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Stratification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Single and Multi-Node Modeling of Direct, Submerged, and Self-Pressurization of A Cryogenic Propellant Tank Using Nodal Tools

The pressurization of cryogenic propellant tanks will always be an important process so long as cryogenic liquids are being considered as fuel sources or used for other in-space applications. Pressure control of the tank ullage is necessary for managing propellant flowrates to an engine or a receiver tank, and modeling of the process is used to predict the pressurant requirements and the amount of propellant boiloff. Direct ullage pressurization is the more traditional approach to tank pressurization, as the physics are straight-forward, and ample test (flight) data have been collected and analyzed over the past several decades. Submerged injection pressurization is an alternate method for tank pressurization and has been shown to reduce pressurant requirements, subcool the propellant, and reduce the risk of ullage collapse. Additionally, the pressurant gas entering the ullage is usually much colder when using the submerged pressurization approach, resulting in reduced propellant boiloff. These benefits are at the expense of vaporizing a small percentage of the propellent. Both tank pressurization methods are viable options for current and future space missions, and it is important to have the capability of analyzing the tank ullage conditions for both approaches. Our previous work has demonstrated the development of a Generalized Fluid System Simulation Program (GFSSP) model, which contains a thermodynamic equilibrium heat and mass transfer subroutine capable of effectively analyzing both direct and submerged pressurization systems [1-2]. This subroutine has most recently been enhanced to include the non-equilibrium effect of pressurant dissolution into the propellant. To date the ullage has always been represented as a single node, and although the simulated single-node temperatures have good comparison with the volume-averaged ullage temperatures computed from test data, the physics of the thermal stratification in the ullage were never captured, and adjustment factors in the model were required. The purpose of this paper is to introduce the development of a multi-node ullage model using GFSSP and to discuss the improvements of the simulated ullage temperature distribution and its resulting effects on ullage heat transfer processes. Test data from the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) was used for model validation. For additional comparison, a Thermal Desktop (TD) model was also developed to analyze the CPST EDU direct ullage pressurization tests using both a single node and multi-node approach. The model includes the direct pressurant line, vent line, fill/drain line, and a TD FloCAD Compartment. The TD FloCAD Compartment is employed to represent the liquid and ullage as single volumes inside the tank, to include a liquid/vapor interface, and to generate network level objects such as lumps (analogous to nodes in GFSSP), paths, and ties between the fluid and thermal elements. An established heat load on the model tank was leveraged from a pre-existing higher-fidelity model correlated to CPST EDU test data.

pressurization↗

Thermal stratification potential in rocket engine coolant channels

The potential for rocket engine coolant channel flow stratification was computationally studied. A conjugate, 3-D, conduction/advection analysis code (SINDA/FLUINT) was used. Core fluid temperatures were predicted to vary by over 360 K across the coolant channel, at the throat section, indicating that the conventional assumption of a fully mixed fluid may be extremely inaccurate. Because of the thermal stratification of the fluid, the walls exposed to the rocket engine exhaust gases will be hotter than an assumption of full mixing would imply. In this analysis, wall temperatures were 160 K hotter in the turbulent mixing case than in the full mixing case. The discrepancy between the full mixing and turbulent mixing analyses increased with increasing heat transfer. Both analysis methods predicted identical channel resistances at the coolant inlet, but in the stratified analysis the thermal resistance was negligible. The implications are significant. Neglect of thermal stratification could lead to underpredictions in nozzle wall temperatures. Even worse, testing at subscale conditions may be inadequate for modeling conditions that would exist in a full scale engine.

Kacynski, Kenneth J.↗

SAM Code Enhancements for Modeling of Liquid Metal-Cooled Fast Reactor Concepts

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. This report summarizes two major efforts in addressing the modeling gaps in SAM for liquid-metal-cooled fast reactor (LMFR) applications, i.e. thermal mixing and stratification phenomena in large pools and corrosion-oxidation of components in flowing lead. A new one-dimensional model for thermal mixing and stratification effects in large pools and enclosures is developed and implemented. Thermal mixing and stratification occur when fluid enters a pool at a temperature different than the bulk fluid itself, a scenario often encountered during transients in pool-type systems. These phenomena are critical for the safety of reactors, impacting phenomena like natural circulation, which is essential for passive cooling. The improved model in SAM addresses limitations of state-of-the-art approaches by combining one-dimensional (1D) channels, representing the coolant jet flow, with lumped-parameter zero-dimensional (0D) pools, representing the rest of coolant in the tank. Energy exchange between the 1D jet and the 0D pools is based on heat transfer correlations calibrated against 3D simulations. It is verified that this model can handle various flow configurations, including hot jets in colder pools, cold jets in hotter pools, and the presence of features like ceilings, free surfaces, and obstacles. Additionally, validation against experimental data demonstrates the ability of the model to capture mixing and stratification effects in a wide range of conditions. The flexibility and improved accuracy of the new model make it a valuable tool for reactor safety analysis, allowing for the simulation of different geometries encountered in advanced reactors. A system-level corrosion modeling capability is developed and implemented in SAM to support Lead Fast Reactor (LFR) development. Although the initial focus of this capability will be on LFR application, this can later be expanded to include other liquid metals such as Lead-Bismuth Eutectic (LBE) and PbLi. This report summarizes the common corrosion mitigation strategies and outlines the progress on implementing and validating a corrosion-oxidation model in SAM. Verification and validation of the corrosion-oxidation portion of the model was performed using analytical solution and measured data from samples tested in the non-isothermal pumped lead loop at IPPE Obninsk. The iron transport and corrosion/precipitation portion of the model was assessed using an analytical model and measured corrosion depths from a natural convection lead loop experiment performed at CEA. It is demonstrated that the model implemented in SAM performed well in these assessments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Detonation structure in the presence of mixture stratification using reaction-resolved simulations

Many investigations of detonation-based combustors have identified reactant mixture inhomogeneity as having a leading-order impact on wave dynamics and combustion efficiency. To examine this phenomenon in a simplified context, an array of two- and three-dimensional channel detonation simulations are conducted in the present work. The reactant mixture consists of stratified fuel and air, wherein the randomly distributed equivalence ratio field features a characteristic stratification length scale. Detailed chemical kinetics are implemented in an adaptive mesh refinement solution framework where the region near the shock front is resolved with Ο (100) cells per representative ZND induction length. The results show that in comparison to baseline cases with uniform reactant mixtures, reactant stratification has a marked impact on the detonation structure. Increasing the stratification length scale increases the size and irregularity of the detonation cells, yielding larger variations in wave speed. Triple point collisions in fuel-rich regions lead to local wave speeds above the notional mean CJ speed, but wave passage through inert regions causes the local wave speed and strength to diminish. Further, conditional statistics show that increasing the stratification length scale increases the variance in pressure and temperature in the primary reaction zone, as well as the variance in heat release over a range of mixture conditions. In addition to the reactant mixture, the impact of the boundary condition behind the detonation is also investigated. The results show that an inflow boundary condition acts to over-drive the wave, leading to higher peak pressures, smaller detonation cells, and increased reactant consumption. On the other hand, cases with a wall behind the wave exhibit weaker waves with lower peak pressures and heat release rates, as well as greater variance in conditional quantities. Comparisons between complementary two- and three-dimensional simulations show reasonable qualitative agreement in wave structure, speed, and conditional statistics.

42 ENGINEERING↗

High temperature high velocity direct power extraction using an open-cycle oxy-combustion system

The implementation of oxy-fuel technology in fossil-fuel power plants may contribute to increased system efficiencies and a reduction of pollutant emissions. One technology that has potential to utilize the temperature of undiluted oxy-combustion flames is open-cycle magnetohydrodynamic (MHD) power generators. These systems can be configured as a topping cycle and provide high enthalpy, electrically conductive flows for direct conversion of electricity. This report presents the design and modeling strategies of a MHD combustor operating at temperatures exceeding 3000 K. Throughout the study, computational fluid dynamics (CFD) models were extensively used as a design and optimization tool. A lab-scale 60 kWth model was designed, manufactured and tested as part of this project. A fully-coupled numerical method was developed in ANSYS FLUENT to characterize the heat transfer in the system. This study revealed that nozzle heat transfer may be predicted through a 40% reduction of the semi-empirical Bartz correlation. Experimental results showed good agreement with the numerical evaluation, with the combustor exhibiting a favorable performance when tested during extended time periods. A transient numerical method was employed to analyze fuel injector geometries for the 60-kW combustor. The ANSYS FLUENT study revealed that counter-swirl inlets achieve a uniform pressure and velocity ratio when the ports of the injector length to diameter ratio (L/D) is 4. An angle of 115 degrees was found to increase distribution efficiency. The findings show that this oxy-combustion concept is capable of providing a high-enthalpy environment for seeding, in order to render the flow to be conductive. Based on previous findings, temperatures in the range of 2800-3000 K may enable magnetohydrodynamic power extraction. The heat loss fraction in this oxy-combustion system, based on CFD and analytical calculations, at optimal operating conditions, was estimated to be less than 10 percent. Furthermore, the heat transfer design removed approximately 7 MW/m2. The results observed in the lab-scale system were employed to develop a 1-MW scaled prototype. Scaling methods were based on critical design criteria found in similar systems, aimed at replicating combustion flow fields and reducing possible instabilities. A numerical simulation of the combustor wall was developed for a combined thermal steady model and static structural model. This combined model was developed predict combined stress parameters within the wall during testing conditions. Both models were developed within ANSYS FEA software package. The relative accuracy presented as well major performance parameters are discussed to assess the design's validity and ensure safety. The scaled prototype was manufactured through selective laser melting (SLM)-based additive manufacturing to reduce lead times and increase geometrical complexity. Additional CFD models were developed to optimize coolant manifold system parameters and perform a parametric study on channel geometry. An investigation on coolant manifold geometry demonstrated improvements in channel flow distribution when enlarging manifold lengths and increasing the number of tubes feeding into the flow. A three-dimensional model based on a single channel was developed to capture the effect of variable properties and thermal stratification. All cases in the simulation exhibited higher wall temperatures and lower convective coefficients than those determined through 1-D analytical equations. This implies that pressure and velocity safety factors must be implemented during system operation. Overall, the findings made in this investigation are thought to be of value to researchers and industrial practitioners when designing oxy-fuel direct power extraction systems operating at temperatures exceeding 3000 K. In addition to this, the implementation of the developed technology at pilot and commercial scales could result in a significant improvement in the efficiencies of heritage and next-generation power cycles.

03 NATURAL GAS↗

North Pacific Cloud Feedbacks Inferred from Synoptic-Scale Dynamic and Thermodynamic Relationships

This study analyzed daily satellite cloud observations and reanalysis dynamical parameters to determine how mid-tropospheric vertical velocity and advection over the sea surface temperature gradient control midlatitude North Pacific cloud properties. Optically thick clouds with high tops are generated by synoptic ascent, but two different cloud regimes occur under synoptic descent. When vertical motion is downward during summer, extensive stratocumulus cloudiness is associated with near surface northerly wind, while frequent cloudless pixels occur with southerly wind. Examinations of ship-reported cloud types indicates that midlatitude stratocumulus breaks up as the the boundary level decouples when it is advected equatorward over warmer water. Cumulus is prevalent under conditions of synoptic descent and cold advection during winter. Poleward advection of subtropical air over colder water causes stratification of the near-surface layer that inhibits upward mixing of moisture and suppresses cloudiness until a fog eventually forms. Averaging of cloud and radiation data into intervals of 500-hPa vertical velocity and advection over the SST gradient enables the cloud response to changes in temperature and the stratification of the lower troposphere to be investigated independent of the dynamics.

Norris, Joel R.↗

Logarithmic scaling of higher-order temperature moments in the atmospheric surface layer

A generalized logarithmic law for high-order moments of homogeneous passive scalars is proposed for turbulent boundary layers. This law is analogous to the generalized log law that has been proposed for high-order moments of the turbulent longitudinal velocity and is derived by combining the random sweeping decorrelation hypothesis with a spectral model informed by the attached eddy hypothesis. The proposed theory predicts that the high-order moments of passive scalar fluctuations within the inertial sublayer will vary logarithmically with wall-normal distance (), and is evaluated using high frequency time-series measurements of temperature and streamwise velocity fluctuations obtained in the first meter of the atmospheric surface layer (ASL) under near-neutral thermal stratification. The logarithmic dependence with within the inertial sublayer is observed in both the air temperature and velocity moments, with good agreement to the predictions from the proposed theory. Surprisingly, the proposed theory appears to be as, if not more, valid for transported passive scalars than for the longitudinal velocity.

54 ENVIRONMENTAL SCIENCES↗

Hydrodynamic Modeling of Stratification and Mixing in a Shallow, Tropical Floodplain Lake

Abstract Floodplain lakes are widespread and ecologically important throughout tropical river systems, however data are rare that describe how temporal variations in hydrological, meteorological and optical conditions moderate stratification and mixing in these shallow lakes. Using time series measurements of meteorology and water‐column temperatures from 17 several day campaigns spanning two hydrological years in a representative Amazon floodplain lake, we calculated surface energy fluxes and thermal stratification, and applied and evaluated a 3‐dimensional hydrodynamic model. The model successfully simulated diel cycles in thermal structure characterized by buoyancy frequency, depth of the actively mixing layer, and other terms associated with the surface energy budget. Diurnal heating with strong stratification and nocturnal mixing were common; despite considerable heat loss at night, the strong stratification during the day meant that mixing only infrequently extended to the bottom at night. Simulations indicated that the diurnal thermocline up and downwelled creating lake‐wide differences in near‐surface temperatures and mixing depths. Infrequent full mixing creates conditions conducive to anoxia in these shallow lakes given their warm temperatures.

Environmental Sciences & Ecology↗

Benchmark Specification for Select Experiments Conducted at the University of Wisconsin-Madison Thermal Stratification Test Facility

The Department of Energy (DOE)-Nuclear Energy University Programs (NEUP) supported the creation and operation of the Thermal Stratification Test Facility (TSTF) at the University of Wisconsin Madison (UWM) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. The TSTF was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements of the flow and temperature were collected for use as experimental benchmarks to support validation efforts for computational models. The results of these tests contribute to the greater understanding of thermal stratification behavior of liquid sodium under various configurations and operating conditions. The six TSTF tests selected for benchmarking are a set of forced circulation tests at a fixed flow rate with different Upper Internal Structure (UIS) configurations in the test section (no UIS, solid UIS, and a UIS with flow area of 4, 8, 12, and 100%). This report provides a complete description of the benchmark problems, including all key test facility details, descriptions of each test condition, and measured data for comparison with modeled results.

42 ENGINEERING↗

On the Use of Ocean Dynamic Temperature for Hurricane Intensity Forecasting

Sea surface temperature (SST) and the Tropical Cyclone Heat Potential (TCHP) are metrics used to incorporate the ocean's influence on hurricane intensification in the National Hurricane Center's Statistical Hurricane Intensity Prediction Scheme (SHIPS). While both SST and TCHP serve as useful measures of the upper-ocean heat content, they do not accurately represent ocean stratification effects. Here we show that replacing SST in the SHIPS framework with a dynamic temperature (Tdy), which accounts for the oceanic negative feedback to the hurricane's intensity arising from storm-induced vertical mixing and sea-surface cooling, improves the model performance. While the model with SST and TCHP explains nearly 41% of the variance in 36-hr intensity changes, replacing SST with Tdy increases the variance explained to nearly 44%. Our results suggest that representation of the oceanic feedback, even through relatively simple formulations such as Tdy, may improve the performance of statistical hurricane intensity prediction models such as SHIPS.

Balaguru, Karthik↗

Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code

The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previous VTR calculation reports, the undocumented limitation in SAS v5.4 does not allow the user to activate the CFD coupling option during restart calculations. Since the analysts were unaware of this limitation, prior SAS-CFD simulation results for the protected station blackout (PSBO) transient were erroneous. Root-cause analysis was performed to determine the cause of this undocumented limitation in SAS v5.4, the SAS software was updated in a new patch, and the SAS-CFD simulations were repeated with this patched software. The results of the SAS-CFD simulations documented in this report show that the software patch does address the cited issue, and that the patched software indeed supports the activation of the CFD coupling model in restart calculations. The SAS development team will determine the schedule for implementing the patch in an official software release. This report documents updated SAS-CFD simulations of the PSBO transient response in the VTR. The hot pool is modeled with the CFD code STAR-CCM+, which is coupled at the flow boundaries to the SAS model of the primary heat transport system. SAS computes the mass flow rate and temperature at each core subassembly outlet, the thermal insulation cavity bypass, and the IHX inlet windows. CFD in turn computes the absolute pressure and temperature at each of these boundaries. The SAS code will ignore the temperature data at flow boundaries where flow is directed into the hot pool, i.e., at the core subassembly outlets unless flow reversal occurs. Similarly, CFD will ignore temperature data at boundaries where the flow is directed out of the hot pool, i.e., at the IHX inlets except under flow reversal. The focus of this work is to ensure that the SAS software patch addresses the undocumented limitation described in prior VTR calculation reports, rather than the accurate assessment of thermal stratification in the VTR during protected transients. This motivates the development of a new, simplified CFD model with a coarser mesh to accelerate the testing process. The updated model, and simplifying assumptions, are documented in this report. In future work, the thermal stratification assessment should be performed in more detail. The simplified CFD model can be improved by performing grid convergence studies sensitivity studies of turbulence parameters (e.g., Prandtl number, turbulence production and dissipation parameters) on temperature distributions and thermal stratification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SPRUCE Deep Peat Microbial Diversity, CO2 and CH4 Production in Response to Nutrient, Temperature, and pH Treatments during Incubation Studies

This dataset contains the results of a microcosm incubation study on deep peat collected from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA in September 2014. Microcosms were monitored for carbon dioxide (CO2) and methane (CH4) production, and microbial community dynamics were assessed using quantitative polymerase chain reaction (qPCR) and amplicon sequencing. The experiment was designed with a full factorial design with elevated temperature, nitrogen (N), (P), and pH treatments was used with samples from each transect serving replicates. In all, 96 microcosms were constructed to account for the 16 treatment combinations (Nitrogen x Phosphorous x pH x temperature), 2 time points, and 3 replicates. Temperature treatments were 6 degrees C, to mimic the SPRUCE ambient plot temperatures, and 15 degrees C to mimic the SPRUCE +9 degrees C treatment. These data show that one year of deep peat warming, microbial community structure and abundance of bacterial, archaeal, fungal, and methanogenic populations showed strong vertical stratification across the peat depth profile yet no clear response to the temperature treatments (Kluber et al, 2020). In an effort to identify factors that may be limiting decomposition and microbial community change in deep peat, we conducted an anerobic microcosm incubation of deep peat (150-200 cm depth). This dataset contains one data file in comma-separate values (*.csv) format. Additional metadata are provided: a data dictionary and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format.

54 ENVIRONMENTAL SCIENCES↗

Experimental annular stratified flames characterisation stabilised by weak swirl

A burner for the investigation of lean stratified premixed flames propagating in intense isotropic turbulence has been developed. Lean pre-mixtures of methane at different equivalence ratios were divided between two concentric co-flows to obtain annular stratification. Turbulence generators were used to control the level of turbulence intensity in the oncoming flow. A third annular weakly swirling airflow provided the flame stabilisation mechanism. A fundamental characteristic was that flame stabilisation did not rely on flow recirculation. The flames were maintained at a position where the local mass flux balanced the burning rate, resulting in a freely propagating turbulent flame front. The absence of physical surfaces in the vicinity of the flame provided free access for laser diagnostics. Stereoscopic Planar Image Velocimetry (SPIV) was applied to obtain the three components of the instantaneous velocity vectors on a vertical plane above the burner at the point of flame stabilisation. The instantaneous temperature fields were determined through Laser Induced Rayleigh (LIRay) scattering. Planar Laser Induced Fluorescence (PLIF) of acetone was used to calculate the average equivalence ratio distributions. Instantaneous turbulent burning velocities were extracted from SPIV results, while flame curvature and flame thermal thickness were calculated using the instantaneous temperature fields. The PDFs of these quantities were analysed to consider the separate influence of equivalence ratio stratification and turbulence. Increased levels of turbulence resulted in the expected higher turbulent burning velocities and flame front wrinkling. Flames characterised by higher fuel gradients showed higher turbulent burning velocities. Increased fuel concentration gradients gave rise to increased flame wrinkling, particularly when associated with positive small radius of curvature. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nineteenth‐Century Tides in the Gulf of Maine and Implications for Secular Trends

Since the early twentieth century, the amplitudes of tidal constituents in the Gulf of Maine and Bay of Fundy display clear secular trends that are among the largest anywhere observed for a regional body of water. The M2 amplitude at Eastport, Maine, increased at a rate of 14.1 ± 1.2 cm per century until it temporarily dropped during 1980–1990, apparently in response to changes in the wider North Atlantic. Annual tidal analyses indicate M2 reached an all‐time high amplitude last year (2018). Here we report new estimates of tides derived from nineteenth century water‐level measurements found in the U.S. National Archives. Results from Eastport, Portland, and Pulpit Harbor (tied to Bar Harbor) do not follow the twentieth century trends and indicate that the Gulf of Maine tide changes commenced sometime in the late nineteenth or early twentieth centuries, coincident with a transition to modern rates of sea‐level rise as observed at Boston and Portland. General agreement is that sea level rise alone is insufficient to cause the twentieth‐century tide changes. A role for ocean stratification is suggested by the long‐term warming of Gulf of Maine waters; archival water temperatures at Boston, Portland, and Eastport show increases of ∼2 °C since the 1880s. In addition, a changing seasonal dependence in M2 amplitudes is reflected in a changing seasonal dependence in water temperatures. The observations suggest that models seeking to reproduce Gulf of Maine tides must consider both sea level rise and long‐term changes in stratification.

Ray, R. D.↗

Analysis of Coastal Fog from a Ship During the C-FOG Campaign

This work presents ship-based measurements of fog off St John’s Newfoundland on 13 September 2018 during the Coastal Fog (C-FOG) field campaign. The measurements included cloud-particle spectra, cloud-base height and aerosol backscatter, radiation, turbulence, visibility, and sea surface temperature. Radiosonde soundings were made at intervals less than 2 hours. Fog occurred in two episodes under the center of eastward-moving synoptic low-pressure system. The boundary layer structure during the first fog episode consisted of 3 layers, separated by 2 saturated air temperature inversions and capped by a subsidence inversion. The lowest layer was fog and the upper layers were cloud. The second fog episode consisted of one well-mixed fog layer capped by a subsidence inversion. Low wind speeds and stable stratification maintained low surface-layer turbulence during fog. Droplet size distributions had typical bimodal distributions. The visibility correlated with the droplet number concentration and liquid water content. The air temperature was higher than the sea surface temperature for the first 30 minutes of the first fog episode but was colder than the sea for the remainder of all fog. The sensible heat flux was upward, from sea to air, for the first 62 % of the first fog episode and then reversed to downward, from air to sea, for the remainder of the first fog episode and the second fog episode. Here, the counter-gradient heat fluxes observed (i.e., opposite to what is expected from the instantaneous air-sea temperature difference) appear to be related to turbulence, entrainment and stratification in the fog layer that overwhelmed the influence of air-sea temperature difference. While the synoptic-scale dynamics preconditioned the area for fog formation, the final step of fog appearance in this case was nuanced by stratification-turbulence interactions, local advective processes and microphysical environment.

54 ENVIRONMENTAL SCIENCES↗

Reference Natural Gas Flames at Nominally Autoignitive Engine-Relevant Conditions

Laminar natural gas flames are investigated at engine-relevant thermochemical conditions where the ignition delay time r is short due to very high ambient temperatures and pressures. At these conditions, it is not possible to measure or calculate well-defined values for the laminar flame speed S-l, laminar flame thickness delta(l), and laminar flame time scale tau(l) = delta(l)/S-l due to the explosive thermochemical state. Here, the corresponding reference values, S-R, delta(R), and tau(R) = S-R/S-R, that account for the effects of autoignition, are numerically estimated to investigate the enhancement of flame propagation, and the competition with autoignition that arises under nominally autoignitive conditions (characterised here by the number tau/tau(R)). Large values of tau/tau(R) indicate that autoignition is unimportant, values near or below unity indicate that flame propagation is not possible, and intermediate values indicate that a combination of both flame propagation and autoignition may be important, depending upon factors such as device geometry, turbulence, stratification, et cetera. The reference quantities are presented for a wide range of temperatures, equivalence ratios, pressures, and hydrogen concentrations, which includes conditions relevant to stationary gas turbine reheat burners and boosted spark ignition engines. It is demonstrated that the transition from flame propagation to autoignition is only dependent on residence time, when the results are non-dimensionalised by the reference values. The temporal evolution of the reference values are also reported for a modelled boosted SI engine. It is shown that the nominally autoignitive conditions enhance flame propagation, which may be an ameliorating factor for the onset of engine knock. The calculations are performed using a recently-developed, detailed 177 species mechanism for C0-C3 chemistry that is derived from theoretical chemistry and is suitable for a wide range of thermochemical conditions as it is not tuned or optimised for a particular operating condition. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

autoignition↗

Improved fluid dynamics similarity, analysis and verification. Part 5: Analytical and experimental studies of thermal stratification phenomena

The stratification behavior of a contained fluid subjected to transient free convection heat transfer was studied. A rectangular vessel was employed with heat transfer from two opposite walls of the vessel to the fluid. The wall temperature was increased suddenly to initiate the process and was then maintained constant throughout the transient stratification period. Thermocouples were positioned on a post at the center of the vessel. They were adjusted so that temperatures could be measured at the fluid surface and at specific depths beneath the surface. The predicted values of the surface temperature and the stratified layer thickness were found to agree reasonably well with the experimental measurements. The experiments also provided information on the transient centerline temperature distribution and the transient flow distribution.

Winter, E. R. F.↗