At least 217 records · Page 12

Unrecoverable lattice rotation governs structural degradation of single-crystalline cathodes

Transitioning from polycrystalline to single-crystalline nickel-rich cathodes has garnered considerable attention in both academia and industry, driven by advantages of high tap density and enhanced mechanical properties. However, cathodes with high nickel content (>70%) suffer from substantial capacity degradation, which poses a challenge to their commercial viability. Here, leveraging multiscale spatial resolution diffraction and imaging techniques, we observe that lattice rotations occur universally in single-crystalline cathodes and play a pivotal role in the structure degradation. These lattice rotations prove unrecoverable and govern the accumulation of adverse lattice distortions over repeated cycles, contributing to structural and mechanical degradation and fast capacity fade. These findings bridge the previous knowledge gap that exists in the mechanistic link between fast performance failure and atomic-scale structure degradation.

36 MATERIALS SCIENCE↗

Phenotypic and genomic characterization of Methanothermobacter wolfeii strain BSEL, a CO 2 -capturing archaeon with minimal nutrient requirements

A new variant of Methanothermobacter wolfeii was isolated from an anaerobic digester using enrichment cultivation in anaerobic conditions. Here, the new isolate was taxonomically identified via 16S rRNA gene sequencing and tagged as M. wolfeii BSEL. The whole genome of the new variant was sequenced and de novo assembled. Genomic variations between the BSEL strain and the type strain were discovered, suggesting evolutionary adaptations of the BSEL strain that conferred advantages while growing under a low concentration of nutrients. M. wolfeii BSEL displayed the highest specific growth rate ever reported for the wolfeii species (0.27 ± 0.03 h –1 ) using carbon dioxide (CO 2 ) as unique carbon source and hydrogen (H 2 ) as electron donor. M. wolfeii BSEL grew at this rate in an environment with ammonium (NH 4 + ) as sole nitrogen source. The minerals content required to cultivate the BSEL strain was relatively low and resembled the ionic background of tap water without mineral supplements. Optimum growth rate for the new isolate was observed at 64°C and pH 8.3. In this work, it was shown that wastewater from a wastewater treatment facility can be used as a low-cost alternative medium to cultivate M. wolfeii BSEL. Continuous gas fermentation fed with a synthetic biogas mimic along with H 2 in a bubble column bioreactor using M. wolfeii BSEL as biocatalyst resulted in a CO 2 conversion efficiency of 97% and a final methane (CH 4 ) titer of 98.5%v, demonstrating the ability of the new strain for upgrading biogas to renewable natural gas.

09 BIOMASS FUELS↗

Complementary Metagenomic Approaches Improve Reconstruction of Microbial Diversity in a Forest Soil

ABSTRACT Soil ecosystems harbor diverse microorganisms and yet remain only partially characterized as neither single-cell sequencing nor whole-community sequencing offers a complete picture of these complex communities. Thus, the genetic and metabolic potential of this “uncultivated majority” remains underexplored. To address these challenges, we applied a pooled-cell-sorting-based mini-metagenomics approach and compared the results to bulk metagenomics. Informatic binning of these data produced 200 mini-metagenome assembled genomes (sorted-MAGs) and 29 bulk metagenome assembled genomes (MAGs). The sorted and bulk MAGs increased the known phylogenetic diversity of soil taxa by 7.2% with respect to the Joint Genome Institute IMG/M database and showed clade-specific sequence recruitment patterns across diverse terrestrial soil metagenomes. Additionally, sorted-MAGs expanded the rare biosphere not captured through MAGs from bulk sequences, exemplified through phylogenetic and functional analyses of members of the phylum Bacteroidetes . Analysis of 67 Bacteroidetes sorted-MAGs showed conserved patterns of carbon metabolism across four clades. These results indicate that mini-metagenomics enables genome-resolved investigation of predicted metabolism and demonstrates the utility of combining metagenomics methods to tap into the diversity of heterogeneous microbial assemblages. IMPORTANCE Microbial ecologists have historically used cultivation-based approaches as well as amplicon sequencing and shotgun metagenomics to characterize microbial diversity in soil. However, challenges persist in the study of microbial diversity, including the recalcitrance of the majority of microorganisms to laboratory cultivation and limited sequence assembly from highly complex samples. The uncultivated majority thus remains a reservoir of untapped genetic diversity. To address some of the challenges associated with bulk metagenomics as well as low throughput of single-cell genomics, we applied flow cytometry-enabled mini-metagenomics to capture expanded microbial diversity from forest soil and compare it to soil bulk metagenomics. Our resulting data from this pooled-cell sorting approach combined with bulk metagenomics revealed increased phylogenetic diversity through novel soil taxa and rare biosphere members. In-depth analysis of genomes within the highly represented Bacteroidetes phylum provided insights into conserved and clade-specific patterns of carbon metabolism.

59 BASIC BIOLOGICAL SCIENCES↗

Single $\pi ^0$ production off neutrons bound in deuteron with linearly polarized photons

The quasifree γ → d → π 0 n(p) photon beam asymmetry, Σ, has been measured at photon energies, E γ , from 390 to 610 MeV, corresponding to center of mass energy from 1.271 to 1.424 GeV, for the first time. The data were collected in the A2 hall of the MAMI electron beam facility with the Crystal Ball and TAPS calorimeters covering pion center-of-mass angles from 49° to 148°. In this kinematic region, polarization observables are sensitive to contributions from the Δ(1232) and N(1440) resonances. The extracted values of Σ have been compared to predictions based on partial-wave analyses (PWAs) of the existing pion photoproduction database. Our comparison includes the SAID, MAID and Bonn–Gatchina analyses; while a revised SAID fit, including the new Σ measurements, has also been performed. In addition, isospin symmetry is examined as a way to predict π 0 n photoproduction observables, based on fits to published data in the channels π 0 p, π + n and π – p.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unconventional Catalytic Approaches to Ammonia Synthesis

Ammonia is a critically important industrial chemical and is largely responsible for sustaining the growing global population. To provide ammonia to underdeveloped regions and/or regions far from industrial production hubs, modular systems have been targeted and often involve unconventional production methodologies. These novel approaches for ammonia production can tap renewable resources at smaller scales located at the point of use, while decreasing the CO 2 footprint. Plasma-assisted catalysis and electrochemical ammonia synthesis have promise owing to their atmospheric pressure and low-temperature operation conditions and the ability to construct units at scales desired for modularization. Fundamental and applied studies are underway to assess these processes, although many unknowns remain. In this review, we discuss recent developments and opportunities for unconventional ammonia synthesis with a focus on plasma-stimulated systems.

42 ENGINEERING↗

divergence in basal transcriptomes of "Wild Type" Chlamydomonas reinhardtii strains

This is a study to compare the basal transcriptomes of several widely used laboratory strains of the Chlorophyte alga, Chlamydomonas reinhardtii. Given that there is a high degree of genetic diversity among the closely-related laboratory strains, we wished to examine how much variation there is at the transcriptome level. A panel of WT strains (CC-124, CC-125, CC-1009, CC-1690, CC-1691), all believed to be descended from a single zygospore isolated in 1945, were chosen based on their representing the oldest lineages among the standard laboratory strains. Additionally, CC-4532, which was the source for the current (v6) reference assembly, and CC-4533, which is the initial parental strain of the CLiP library collection of mutant strains, were also included in this study based on their significance to the Chlamydomonas community. All strains were grown in liquid cultures under identical, mixotrophic conditions (light + acetate) to mid-log phase before collecting mRNA for RNA-Seq analysis. Overall design: Pre-cultures of each strain (CC-124, CC-125, CC-1009, CC-1690, CC-1691, CC-4532, and CC-4533) were used to innoculate flasks of Tris-Acetate-Phosphate (TAP) media supplemented with Kropat's trace metals at a concentration of 1.5 x 10^4 cells/mL. Flasks were placed on a shaking platform at 180 RPM under 50-70 µmol x m^-2 x s^-1 of light. Cultures were grown until they reached ~2-3 x 10^6 cells/mL, about three days, before total RNA was collected and subjected RNA-Seq analysis.

Source record↗

WindWatts Computational Framework and Web UI [SWR-20-100]

This software provides a collection of algorithms, an API, and a functional Web UI for the Distributed Wind’s WindWatts project. DW WindWatts is a DOE WETO-funded project aimed at the development of tools to supporting the distributed wind industry, particularly with respect to siting and resource assessment. The computational framework and the back-end API are powering the easy to use front-end services available at: https://windwatts.nrel.gov. https://github.com/NREL/dw-tap-api; https://github.com/NREL/dw-tap; https://github.com/NREL/windwatts-data For reference, this software was previously known as DW TAP Computational Framework.

Phillips, Caleb↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗

pnnl/FLOWER

Network FLOW analyzER - Network bi-directional deep packet header inspection. This software is designed to generate custom network flow records by monitoring bi-directional traffic from a span port, tap or other source. This function is independent of proprietary hardware or software solutions. This tool solves the problem of existing COTS solutions being either too complex or too slow.

Curtis, Darren↗

CFD-Enhanced Calibration of a Multihole Probe for Small Uncrewed Aircraft Systems

A robust calibration method with a 9-hole probe (9HP) for inertial wind vector measurements from a small uncrewed aircraft system (sUAS) is presented. Calibration accuracy is improved by using computational fluid dynamics (CFD) to estimate corrections, such as those for test section blockage, that are generally applied in wind tunnel testing. A method for estimating experimental bias is presented to account for flow variations over the pressure taps as the 9HP is repositioned in the test section. Installation effects from flow over the airframe and upwash produced by the wings are estimated from CFD simulations of the entire airframe at the expected cruise speed. An initial CFD analysis has demonstrated a quantifiable linear relationship between the measured and actual angle of attack as measured from the relative wind frame. In conclusion, the objective of these additional steps is to increase the accuracy of 9HP calibration.

54 ENVIRONMENTAL SCIENCES↗

Development, Testing, and Validation of Fabry-Pérot Cavity Acoustic Sensors for Microreactor Applications

Nuclear microreactors are a unique reactor design which may allow for the nuclear energy industry to tap into unconventional markets, and their modularity presents some advantages over larger, conventional reactor designs. For nuclear microreactors to be economically viable, on-line structural health monitoring may be necessary to reduce operation and maintenance costs with lower power production. Optical fiber sensors, and specifically optical Fabry-Pérot cavities (FPCs), may present the opportunity to monitor vibrational frequencies of microreactor components during operation, enabling identification of the location and severity of potential damage. In this work, FPCs were designed and fabricated with materials which may be able to survive in the extremely harsh environment of nuclear microreactors. The FPCs were bonded to metal test specimens to monitor their vibrational frequencies, along with a reference piezoelectric accelerometer. Euler-Bernoulli theory was used to calculate the fundamental modes and mode-shapes to compare with experimentally measured frequency spectra. The peak frequencies detected with the FPC and piezoelectric accelerometer, and theoretical modes, all agreed well for the first four fundamental modes (within 5%). Furthermore, when the FPC and accelerometer were co-located on the test specimen, their peak frequencies all agreed within 1%.

Birri, Tony↗

Rapid simulations of hyperspectral near-field images of three-dimensional heterogeneous surfaces – part II

The modeling of the near-field interaction in the scattering-type scanning near-field optical microscope (s-SNOM) is rapidly advancing, although an accurate yet versatile modeling framework that can be easily adapted to various complex situations is still lacking. In this work, we propose a time-efficient numerical scheme in the quasi-electrostatic limit to capture the tip-sample interaction in the near field. This method considers an extended tip geometry, which is a significant advantage compared to the previously reported method based on the point-dipole approximation. Using this formalism, we investigate, among others, nontrivial questions such as uniaxial and biaxial anisotropy in the near-field interaction, the relationship between various experimental parameters (e.g. tip radius, tapping amplitude, etc.), and the tip-dependent spatial resolution. The demonstrated method further sheds light on the understanding of the contrast mechanism in s-SNOM imaging and spectroscopy, while also representing a valuable platform for future quantitative analysis of the experimental observations.

Chen, Xinzhong (ORCID:0000000261033848)↗

Literature Data on Foam Fracturing Fluid

At the beginning of this project, the Temple team spent significant effort to collect data relevant to foam fracturing. More than 40 articles/reports were found in the open literature that reported the properties of aqueous foams under various testing conditions. The foam properties included viscosity and stability in terms of half-life, while were influenced by the foam quality, shear rate, temperature, pressure, as well as surfactants and additives used in making the foam base solutions. As a result, more than 1100 data points were collected, which are included in a master worksheet named "Literature data on Foam Fracturing Fluid". These data points are organized based on following parameters: 1. Literature source, including authors and publication year 2. Gaseous phase (e.g. CO2, N2) 3. Liquid phase (e.g. tap water, DI water, salt water) 4. Surfactants and their concentrations 6. Additives 7. Foam quality 8. Pressure 9. Temperature 10. Viscosity 11. Foam stability, which was characterized by its half-life: Half-life Foam study data base with data analysis was completed and a webpage is designed hosted on public server at https://surfactant-dashboard.herokuapp.com

15 GEOTHERMAL ENERGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unattended Single Channel Analyzer (USCA) FY20 Summary Report

In FY20 LANL was funded to design, fabricate, test and document an instrument that can be used by the IAEA for gamma ray measurements in scintillator applications. This instrument, the Unattended Single Channel Analyzer (USCA), will be part of the family of IAEA unattended instruments and completes the suite of most used data acquisition needs provided by the previously designed UNAP instrument. The USCA is designed to meet all the same IAEA requirements designed into the UMSR and UDCM. The new instrument has the same look and feel making it simple for agency staff to move between instruments. This project taps into all the design functions developed during the UMSR and UDCM development. Along with the design and fabrication of a USCA, this project included production of a prototype for IAEA testing and a complete set of documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Reports of the 2020 Los Alamos National Laboratory Computational Physics Student Summer Workshop

For the past ten years, the workshop has been bringing a highly talented and diverse group of student every summer. Students work in teams of two, alongside typically two mentors, on research projects reflecting a broad range of topics within computational physics. In addition, students attend a series of lectures on topics within computational physics, facility tours, and networking events. The program lasts ten weeks, with this year’s workshop running from June 8 to August 14. At the end of the summer, students give a final presentation, along with a written report. Those reports are what make up the remaining sections of this document. Admission to the workshop is by a competitive process, with the mentors forming the selection committee. One of the important accomplishments of the workshop has been to create a student pipeline from diverse schools that sometimes are not normally tapped by LANL recruiting. Many workshop students maintain a continuing relationship with LANL, returning as students interns, post-doctoral researchers, and staff members. Additionally, workshop alumni act as ambassadors for LANL. The result is a wider awareness both of LANL as a potential employer, and of the technical work that happens at LANL. This year, the workshop format was changed in several ways, in order to accommodate the off-site, virtual format. Students worked on LANL virtual desktop systems remotely, also accessing LANL HPC resources. In order to facilitate communication, student were given accounts on both Webex, a video teleconferencing platform, and Mattermost, an online team collaboration and chat platform, similar to Slack. Daily communication between students and mentors was primarily on Mattermost, with Webex conferencing as needed. The lectures were all done on Webex. Given the difficulty of the virtual format, and a concern that students might have video teleconferencing burn-out after an academic semester largely moved to that format, all lectures were optional this year. In spite of this, the attendance was generally high. Lecturers were asked to try to move to a more high-level, ”What is it?,” format. Once again, the students did a tremendous job. Over the course of ten weeks, they did important research across a staggering array of disciplines. The following pages contain the final report for each team’s research efforts. We hope you will find reading them as exciting as it was for us to produce them.

36 MATERIALS SCIENCE↗

Cyber Secure Sensor Network for Fossil Fuel Power Generation Assets Monitoring

The energy sector is undergoing digital transformation which is to say more and more power generation assets have become automated and connected to the internet. The connected sensors can tap into plants to monitor the health of assets and manage fleets remotely. These are just some of the benefits digitalization is bringing to the power industry. Within a power plant, control systems are no longer concerned with one system or one piece of equipment, but rather whole fleet of assets inter-connected with smart sensors which have the function of continuously monitoring and transmitting real-time operational data to operators. These connected systems will form a part of the industrial internet of things (IIoT). The big data scenarios provide benefits of performing system prognostics and optimization which is a key selling point of power plant digitalization.

20 FOSSIL-FUELED POWER PLANTS↗

“Mirror” magnet experiment for quench studies, quench analysis techniques development and in support of superconducting magnet modeling

In order to progress on various research points related to superconducting magnets, we suggest performing series of tests with induced and natural quenches on a mirror magnet, probably using a “11 T” coil. The “mirror” is to have voltage taps instrumented on half the strands, on both coil ends. It is to be instrumented with multiple spot-heaters, of the order of ten, in designated pole-turn areas. Instrumentation is to include quench antenna array facing the inner coil surface, as well as acoustic sensors on the inner layer pole. Further, acoustic sensors at the magnet ends and an acoustic calibration transducer are to be installed. Thus, we are to test sensitivity and precision of acoustic and quench antenna (QA) array sensors, both at close proximity to the coil, and we are to test and commission acoustic on-magnet real-time “calibration”. New or extended DAQ will be tested as well. In addition to diagnostic development, the purpose of the magnet experiment is to investigate current redistribution in the coil, both during quenching and in operating conditions; to assess voltage build up across strands and in the coil segments during quenching, to explore voltage signature differentiation between different type of quenches; to improve modeling of processes during quenching and for magnet design purposes. In this experiment, we expect to be able to characterize the processes during a quench in unprecedented details.

43 PARTICLE ACCELERATORS↗