Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Rapid solidification via melt spinning - Equipment and techniques

One of the simpler methods available to accomplish rapid solidification processing is free jet melt spinning. With only a modest expenditure of time, effort, and capital, an apparatus suitable for preliminary experimentation can be assembled. Wheel and crucible materials, process atmospheres, crucible design, heating methods, and process parameters and their relationship to melt composition are described. Practical solutions to processing problems, based on 'hands-on' experience, are offered. Alloys with melting points up to 3000 F have been rapidly solidified using the techniques described.

Jech, R. W.↗

Optical Pattern Recognition With Self-Amplification

In optical pattern recognition system with self-amplification, no reference beam used in addressing mode. Polarization of laser beam and orientation of photorefractive crystal chosen to maximize photorefractive effect. Intensity of recognition signal is orders of magnitude greater than other optical correlators. Apparatus regarded as real-time or quasi-real-time optical pattern recognizer with memory and reprogrammability.

Liu, Hua-Kuang↗

Measurement of the Electric Form Factor of the Neutron at High Momentum Transfer

The E02-013 collaboration's precision measurement of the electric form factor of the neutron at high momentum took place in Hall A of Jefferson Laboratory [1]. Four kinematic points spread in Q2 from 1.2 to 3.5 (GeV/c)2 reach the region of momentum transfer where there is little ambiguity that the form factors are dominated by the valence quarks. The electric form factor provides important constraints on the generalized parton distributions (GPDs) of the nucleon and therefore to understand the currently unknown quark angular orbital moments. The talk presented newly obtained results for GnE including at Q2 of 2.5 (GeV/c)2. These measurements provide access to twice the range of momentum transfer for complete iso-spin decomposition of the nucleon form factors. The form factors of the u and d quarks were also presented. The measurement used a double polarization asymmetry method [2][3] with He polarized up to 55% (provided by a novel hybrid alkali optical pumping scheme utilizing a Rb & K mixture) and the highly polarized (85%) electron beam at CEBAF. A specially constructed detector package consisting of an electron spectrometer, named Big-Bite, with a solid angle of 95 msr and a large neutron detector were used to detect the particles in the reaction {sup 3}H{rvec e}({rvec e},e',h). The experimental apparatus provided more than 100 times better Figure-of-Merit than other GnE experiments utilizing polarized targets; for more information see [4].

43 PARTICLE ACCELERATORS↗

Actinide-ion sensor

An apparatus for the real-time, in-situ monitoring of actinide-ion concentrations. A working electrolyte is positioned within the interior of a container. The working electrolyte is separated from a reference electrolyte by a separator. A working electrode is at least partially in contact with the working electrolyte. A reference electrode is at least partially in contact with the reference electrolyte. A voltmeter is electrically connected to the working electrode and the reference electrode. The working electrolyte comprises an actinide-ion of interest. The separator is ionically conductive to the actinide-ion of interest. The separator comprises an actinide, Zr, and Nb. Preferably, the actinide of the separator is Am or Np, more preferably Pu. In one embodiment, the actinide of the separator is the actinide of interest. In another embodiment, the separator further comprises P and O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

M.I.T. Stirling-cycle heat transfer apparatus

The design and construction of a two-cylinder apparatus to measure heat transfer under conditions of oscillating pressure and oscillating flow such as found in Stirling-cycle machines are described. The apparatus consists of two large single-stage air compressors joined by a rigid drive shaft between the two crack shafts, and is powered by a 25-hp variable speed DC motor. The apparatus is capable of measuring heat transfer while velocity and pressure change over the range of dimensionless parameters normally found in Stirling cycle machines. It allows each parameter to be varied independently and easily. Instrumentation for the apparatus is adequate for measurement of pressure, time, gas and wall temperature, wall heat flux, and gas velocity. It yields preliminary data which show that the apparatus and data acquisition are operating satisfactorily and produce reasonable results.

Smith, Joseph L., Jr.↗

OH detection by Ford Motor Company

Two different methods for detection of OH are presented: a low pressure flow cell system and a frequency modulation absorption measurement. Using conventional absorption spectroscopy, detection limits were quoted of 1,000,000 OH molecules per cu cm using a 30-minute averaging time on the ground, and a 3-hour averaging time in the air for present apparatus in use. With the addition of FM spectroscopy at 1 GHz, a double-beam machine should permit detectable absorption of and an OH limit of 100,000 per cu cm in a 30-minute averaging time. In the low pressure system on which experiments are ongoing nonexponential time behavior was observed after the decay had progressed to about 0.3 of its original level; this was attributed to ion emission in the photomultiplier. A flame source with OH present at high concentration levels was used as a calibration. It was estimated that within the sampling chamber, 400,000 OH could be measured. With a factor-of-2 loss at the sampling orifice, this means detectability of 5 to 8 x 100,000 cu cm at the present time. This could be reduced by a factor of 2 in one hour averaging time; improvements in laser bandwidth and energy should provide another factor of 2 in sensitivity.

Wang, Charles C.↗

Apparatus and Method for Compensating for Process, Voltage, and Temperature Variation of the Time Delay of a Digital Delay Line

A process, voltage, and temperature (PVT) compensation circuit and a method of continuously generating a delay measure are provided. The compensation circuit includes two delay lines, each delay line providing a delay output. The two delay lines may each include a number of delay elements, which in turn may include one or more current-starved inverters. The number of delay lines may differ between the two delay lines. The delay outputs are provided to a combining circuit that determines an offset pulse based on the two delay outputs and then averages the voltage of the offset pulse to determine a delay measure. The delay measure may be one or more currents or voltages indicating an amount of PVT compensation to apply to input or output signals of an application circuit, such as a memory-bus driver, dynamic random access memory (DRAM), a synchronous DRAM, a processor or other clocked circuit.

Seefeldt, James↗

Time-reversed nonlinear acoustic downhole pore pressure measurements

Apparatus (10) and methods for measurement of pore pressure in rock formations through a metal borehole casing (32) after a well is cased and cemented, are described. Such measurements may be accomplished by using the Dynamic Acoustic Elasticity (DAE) method for characterizing nonlinear parameters by perturbing a selected rock formation region with a High Amplitude, Low Frequency (HALF) acoustic strain wave, and probing this region using a Low Amplitude, High Frequency (LAHF) acoustic wave (18), (22). Time reversal techniques (36) may be employed for focusing acoustic energy into the formation in the vicinity of the pipe or open hole. The change in wave speed of the probe pulses as the HALF induced strain wave oscillation propagates through the formation, as a function of the induced strain, may be used to determine the nonlinear elastic parameters α, β, δ, and A of the pore pressure, from which the pore pressure may be determined in the region of the HALF wave.

Goodman, Harvey E.↗

The Varestraint test for refractory metals, task 2

The principles of the Varestraint test were applied to the evaluation of refractory metal alloys. This required development of a special test apparatus employing a modest specimen size for improved economy and compatible with the high purity inert atmosphere required for welding these alloys. Minimum specimen size is desirable because of the high cost of these alloys and also to permit timely testing of limited production developmental alloys. The Varestraint apparatus satisfies these requirements by providing a timely and economic test for hot crack sensitivity. This test can be used both for alloy development and production surveillance. The test apparatus was designed for use in vacuum purged dry boxes and is completely compatible with high purity inert atmosphere. Augmented strain can be varied continuously from 1/4% thru 4%. In addition to varying the augmented strain, the primary Varestraint variable, the effect on hot cracking of varying other weld parameters such as unit weld length heat input have also been studied. Test reproducibility, in terms of bending or strain rate, was demonstrated using high speed photography.

Lessmann, G. G.↗

Apparatus Would Stain Microscope Slides

Proposed apparatus meters specific amounts of fluid out of containers at specific times to stain microscope slides. Intended specifically for semiautomated staining of microbiological and hematological samples in microgravity, leakproof apparatus used in other environments in which technicians have little time to allocate to staining procedures and/or exposure to toxic staining agents or to micro-organisms to be stained hazardous. Apparatus adapted to perform almost any staining procedure and accommodates multiple staining reagents, useful for small or remote clinical laboratories.

Breeding, James D.↗

Hydraulic Apparatus for Mechanical Testing of Nuts

The figure depicts an apparatus for mechanical testing of nuts. In the original application for which the apparatus was developed, the nuts are of a frangible type designed for use with pyrotechnic devices in spacecraft applications in which there are requirements for rapid, one-time separations of structures that are bolted together. The apparatus can also be used to test nonfrangible nuts engaged without pyrotechnic devices. This apparatus was developed to replace prior testing systems that were extremely heavy and immobile and characterized by long setup times (of the order of an hour for each nut to be tested). This apparatus is mobile, and the setup for each test can now be completed in about five minutes. The apparatus can load a nut under test with a static axial force of as much as 6.8 x 10(exp 5) lb (3.0 MN) and a static moment of as much as 8.5 x 10(exp 4) lb in. (9.6 x 10(exp 3) N(raised dot)m) for a predetermined amount of time. In the case of a test of a frangible nut, the pyrotechnic devices can be exploded to break the nut while the load is applied, in which case the breakage of the nut relieves the load. The apparatus can be operated remotely for safety during an explosive test. The load-generating portion of the apparatus is driven by low-pressure compressed air; the remainder of the apparatus is driven by 110-Vac electricity. From its source, the compressed air is fed to the apparatus through a regulator and a manually operated valve. The regulated compressed air is fed to a pneumatically driven hydraulic pump, which pressurizes oil in a hydraulic cylinder, thereby causing a load to be applied via a hydraulic nut (not to be confused with the nut under test). During operation, the hydraulic pressure is correlated with the applied axial load, which is verified by use of a load cell. Prior to operation, one end of a test stud (which could be an ordinary threaded rod or bolt) is installed in the hydraulic nut. The other end of the test stud passes through a bearing plate; a load cell is slid onto that end, and then the nut to be tested is threaded onto that end and tightened until the nut and load cell press gently against the bearing plate.

Hinkel, Todd J.↗

Continuous-flow electrophoretic separator for biologicals

In the near absence of gravity, a continuous-flow type of electrophoretic separator can be operated with a much thicker separation chamber than is possible under 1 g conditions. This should permit either better resolution or shorter separation time per unit of sample. An apparatus to perform experiments on sounding rockets is under development and will be described. The electrophoresis cell is 5 mm thick by 5 cm wide with 10 cm long electrodes. It is supplied with buffer, sample, and coolant at about 4 C through the use of a passive refrigerant system. UV sample detection and provision for recovery and cold storage of up to 50 sample fractions are now being added to the basic unit. A wide range of operating conditions are electronically programmable into the unit, even up to a short time before flight, and a further range of some parameters can be achieved by exchanging power supplies and by changing gears in the motor drive units of the pump. The preliminary results of some separation studies on various biological products using a commercially available electrophoretic separator are also presented.

Mccreight, L. R.↗

A compact high-performance low-field NMR apparatus for measurements on fluids at very high pressures and temperatures

We discuss an innovative new high-performance apparatus for performing low-field Nuclear Magnetic Resonance (NMR) relaxation times and diffusion measurements on fluids at very high pressures and high temperatures. The apparatus sensor design and electronics specifications allow for dual deployment either in a fluid sampling well logging tool or in a laboratory. The sensor and electronics were designed to function in both environments. This paper discusses the use of the apparatus in a laboratory environment. The operating temperature and pressure limits, and the signal-to-noise ratio (SNR) of the new system exceed by a very wide margin what is currently possible. This major breakthrough was made possible by a revolutionary new sensor design that breaks many of the rules of conventional high pressure NMR sensor design. A metallic sample holder capable of operating at high pressures and temperatures is provided to contain the fluid under study. The sample holder has been successfully tested for operation up to 36 Kpsi. A solenoid coil wound on a slotted titanium frame sits inside the metallic sample holder and serves as an antenna to transmit RF pulses and receive NMR signals. The metal sample holder is sandwiched between a pair of gradient coils which provide a linear field gradient for pulsed field gradient diffusion measurements. The assembly sits in the bore of a low-gradient permanent magnet. The system can operate over a wide frequency range without the need for tuning the antenna to the Larmor frequency. The SNR measured on a water sample at room temperature is more than 15 times greater than that of the commercial low-field system in our laboratory. Thus, the new system provides for data acquisition more than 200 times faster than was previously possible. Laboratory NMR measurements of relaxations times and diffusion coefficients performed at pressures up to 25 Kpsi and at temperatures up to 175 °C with crude oils enlivened with dissolved hydrocarbon gases (referred to as “live oils”) are shown. This is the first time low-field NMR measurements have been performed at such high temperatures and pressures on live crude oil samples. We discuss the details of the apparatus design, tuning, calibration, and operation. NMR data acquired at multiple temperatures and pressures on a live oil sample are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

Olson, Sandra↗

Nonlinear luminescence response of CaF{sub 2}:Eu and YAlO{sub 3}:Ce to single-ion excitation

Understanding scintillation physics and nonproportionality is essential to accelerate materials discovery that has been restricted due to the difficulties inherent to large crystal growth and complex nature of gamma-solid interaction. Taking advantage of less restrictive growth and deposition techniques for smaller crystal sizes or thin films and better fundamental understanding of ion-solid interactions, a unique ion approach is demonstrated to effectively screen candidate scintillators with relatively small size and evaluate their nonlinear scintillation response. Response of CaF{sub 2}:Eu and YAlO{sub 3}:Ce scintillators to single ions of H{sup +}, He{sup +}, and O{sup 3+} are measured by the corresponding pulse height over a continuous energy range using a time-of-flight–scintillator–photoelectric multiplier tube apparatus. Nonlinear response of the scintillators under ionizing ion irradiation is quantitatively evaluated by considering the energy partitioning process. In a differential energy deposition region with negligible displacement damage, the low, medium and high excitation energy deposition density (D{sub exci}) can be produced by energetic H{sup +}, He{sup +} and O{sup 3+} ions, respectively, and significantly different impacts on the response characteristics of these two benchmark scintillators are observed. For CaF{sub 2}:Eu, the scintillation efficiency under ion irradiation monotonically decreases with increasing excitation-energy density. In contrast, the response efficiency of YAlO{sub 3}:Ce scintillation initially increases with excitation-energy density at low excitation-energy densities, goes through a maximum, and then decreases with further increasing excitation-energy density. The fundamental mechanism causing these different response behaviours in the scintillators is based on the competition between the scintillation response and the nonradiative quenching process under different excitation densities, which is also the main origin of the nonlinear response of the scintillators to irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A versatile electron-ion coincidence spectrometer for photoelectron momentum imaging and threshold spectroscopy on mass selected ions using synchrotron radiation

We present a photoelectron-photoion coincidence (PEPICO) spectrometer named DELICIOUS II which combines a velocity map imaging apparatus with a Wiley-McLaren time of flight analyzer for the study of gas phase samples in interaction with the synchrotron radiation (SR). This versatile system is capable of providing photoelectron images on mass-selected compounds with kinetic energy resolutions of {delta}E/E=5% and a 17 eV bandwidth, as well as threshold photoelectron spectra with a measured resolution of 0.8 meV, as demonstrated on the 3p{sup -1} ionization of argon. This instrument is also employed for threshold PEPICO experiments, allowing the selection of the parent ion's internal state with sub-meV resolution for light masses (<40 amu) and with typically 2 meV resolution for a mass of 100 amu and with a mass resolving power above 200. The continuous operation of the extraction fields and the independence from the electron's time of flight are well adapted to the quasicontinuous multibunch mode of the SR. This, together with the high transmission of both the electron and ion detection, allows a high coincidence counting rate and facilitates the subtraction of false coincidences. We illustrate the spectrometer's coincidence principle of operation with examples from the valence photoionization of an Ar+Xe mixture and of CF{sub 4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full waveform analysis for high pressure ultrasonic measurement

In this paper we report a data analysis protocol for ultrasonic velocity measurements carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. Synthetic ultrasonic signals for the time period between echoes from the two ends of the sample assembly are created with a few simple parameters as the echo waveform is modeled by the first echo from the anvil-assembly boundary. Each echo is modeled as a delta function with an amplitude and arrival time and convolved with this waveform. The final waveform, fit to the data, enables analysis of signals with overlapped echoes as they are common in small cell assemblies and high pressure.

47 OTHER INSTRUMENTATION↗

Photon statistics in the macroscopic realm measured without photon counters

In a macroscopic realm, in which photons are too many to be counted by any photon-counting detector, photon statistics can be measured by using detectors simply endowed with linear response. We insert one of such detectors in a conventional photon-counting apparatus, which returns a voltage every time the detector responds to light by generating a number of elementary charges via its primary photodetection process. We only assume that, when a single charge is photogenerated, the probability density of the voltages is a distribution that is narrow with respect to its mean value. Under this hypothesis the output voltages can be suitably binned so that their probability distribution is the same as that of the photogenerated charges, that is, of the detected photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗