Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Switched systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Ethernet for Space Flight Applications

NASA's Goddard Space Flight Center (GSFC) is adapting current data networking technologies to fly on future spaceflight missions. The benefits of using commercially based networking standards and protocols have been widely discussed and are expected to include reduction in overall mission cost, shortened integration and test (I&T) schedules, increased operations flexibility, and hardware and software upgradeability/scalability with developments ongoing in the commercial world. The networking effort is a comprehensive one encompassing missions ranging from small University Explorer (UNEX) class spacecraft to large observatories such as the Next Generation Space Telescope (NGST). Mission aspects such as flight hardware and software, ground station hardware and software, operations, RF communications, and security (physical and electronic) are all being addressed to ensure a complete end-to-end system solution. One of the current networking development efforts at GSFC is the SpaceLAN (Spacecraft Local Area Network) project, development of a space-qualifiable Ethernet network. To this end we have purchased an IEEE 802.3-compatible 10/100/1000 Media Access Control (MAC) layer Intellectual Property (IP) core and are designing a network node interface (NNI) and associated network components such as a switch. These systems will ultimately allow the replacement of the typical MIL-STD-1553/1773 and custom interfaces that inhabit most spacecraft. In this paper we will describe our current Ethernet NNI development along with a novel new space qualified physical layer that will be used in place of the standard interfaces. We will outline our plans for development of space qualified network components that will allow future spacecraft to operate in significant radiation environments while using a single onboard network for reliable commanding and data transfer. There will be a brief discussion of some issues surrounding system implications of a flight Ethernet. Finally, we will show an onboard network architecture for a proposed new mission using Ethernet for science data transport.

Webb, Evan↗

Use of graphics in the design office at the Military Aircraft Division of the British Aircraft Corporation

The CAD/CAM interactive computer graphics system was described; uses to which it has been put were shown, and current developments of the system were outlined. The system supports batch, time sharing, and fully interactive graphic processing. Engineers using the system may switch between these methods of data processing and problem solving to make the best use of the available resources. It is concluded that the introduction of on-line computing in the form of teletypes, storage tubes, and fully interactive graphics has resulted in large increases in productivity and reduced timescales in the geometric computing, numerical lofting and part programming areas, together with a greater utilization of the system in the technical departments.

Coles, W. A.↗

Constant-voltage drive current-steering switch

Two-element voltage control system regulates a magnetic switch consisting of dual ferrite-core shift registers. The system has a magnetic, two-core-per-bit, voltage-controlled shift register.

Caplette, R. K.↗

Chemical pumps and flexible sheets spontaneously form self-regulating oscillators in solution

The synchronization of self-oscillating systems is vital to various biological functions, from the coordinated contraction of heart muscle to the self-organization of slime molds. Through modeling, we design bioinspired materials systems that spontaneously form shape-changing self-oscillators, which communicate to synchronize both their temporal and spatial behavior. Here, catalytic reactions at the bottom of a fluid-filled chamber and on mobile, flexible sheets generate the energy to “pump” the surrounding fluid, which also transports the immersed sheets. The sheets exert a force on the fluid that modifies the flow, which in turn affects the shape and movement of the flexible sheets. This feedback enables a single coated (active) and even an uncoated (passive) sheet to undergo self-oscillation, displaying different oscillatory modes with increases in the catalytic reaction rate. Two sheets (active or passive) introduce excluded volume, steric interactions. This distinctive combination of the hydrodynamic, fluid–structure, and steric interactions causes the sheets to form coupled oscillators, whose motion is synchronized in time and space. We develop a heuristic model that rationalizes this behavior. These coupled self-oscillators exhibit rich and tunable phase dynamics, which depends on the sheets’ initial placement, coverage by catalyst and relative size. Moreover, through variations in the reactant concentration, the system can switch between the different oscillatory modes. This breadth of dynamic behavior expands the functionality of the coupled oscillators, enabling soft robots to display a variety of self-sustained, self-regulating moves.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A High Voltage Distribution System for the Mu2e Electron Tracker

This paper describes the design and development of a High Voltage distribution system (Smart Switch - SS) which distributes one input high voltage (HV) into six High Voltage channels (HVDS) of a straw detector plane. The SS independently sets, controls, and monitors the HV to each individual channel of a straw-detector plane in the Mu2E Electron Tracking Detector. Each straw plane is composed of three 120 deg crescent-shaped panels, and each panel is composed of 96 straw-tube detectors. Each output channel of the SS has independent, ON-OFF, current and HV monitoring, as well as filtration, isolation, and a crowbar to provide overcurrent protection for in that channel. The inter-communication system is based on TCP/IP protocol using a Raspberry Pi. The HVDS meets all required specifications including long term stability, accurate monitoring of the HV and current, and overcurrent trip. The performance of the HVDS was found to be comparable to, if not better than, commercial HV power supplies.

42 ENGINEERING↗

A study of universal modulation techniques applied to satellite data collection

A universal modulation and frequency control system for use with data collection platform (DCP) transmitters is examined. The final design discussed can, under software/firmwave control, generate all of the specific digital data modulation formats currently used in the NASA satellite data collection service and can simultaneously synthesize the proper RF carrier frequencies employed. A novel technique for DCP time and frequency control is presented. The emissions of NBS radio station WWV/WWVH are received, detected, and finally decoded in microcomputer software to generate a highly accurate time base for the platform; with the assistance of external hardware, the microcomputer also directs the recalibration of all DCP oscillators to achieve very high frequency accuracies and low drift rates versus temperature, supply voltage, and time. The final programmable DCP design also employs direct microcomputer control of data reduction, formatting, transmitter switching, and system power management.

Source record↗

Modular, Multifunction, Multiport and Medium Voltage Utility Scale SiC PV Inverter (Final Report)

This project is to develop and demonstrate a Modular, Multi-function, Multiport and Medium Voltage utility scale SiC solar inverter (M4 Inverter). The M4 Inverter is a next generation utility scale PV + storage inverter that can substantially reduce the levelized cost of energy (LCOE) while providing grid friendly ancillary services. Conventional utility scale solar inverters includes three parts, a megawatt rated solar inverter, a low frequency transformer (LFT) and a medium voltage switch gear. The proposed M4 Inverter directly converts the DC output of solar panels to medium voltage AC, eliminating the bulky and costly LFT. The M4 Inverter also has a DC port to interface with an additional energy storage device. This plus its bidirectional power flow capability, allows multiple functions in addition to PV maximum power tracking be achieved. These additional functionalities include but not limited to reactive power support, peak shaving, fast frequency regulation and synthetic inertia. Predicted LCOE reductions with these added functionalities, improved efficiency and longer lifetime time are more than 30% compared with the 2017 utility scale solar LCOE. A 1MVA SiC M4 Inverter was developed and tested at high power level. The project has also advanced the state of the art in controller hardware in the loop simulation capability. Power electronic innovations introduced in the M4 Inverter includes 1700V SiC MOSFET application in 1500V PV system, soft switching three-port power converters and modular converter architecture.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insights on the Influence of the Central-Cut Width of the Box Assembly with Removable Component on Its Dynamical Responses

This investigation focuses on the dynamical effects caused by varying the central-cut width within the Box Assembly with Removable Component (BARC) system. The central-cut widths included in this study are a 0.5″ cut, a 0.25″ cut, a thin 0.1″ cut, and a structure that did not have a cut at all. Finite element analysis was conducted to determine the mode shapes and natural frequencies of each of the BARC structures. Structural dynamics experiments were run to examine the effects of the central-cut width on the dynamical responses and nonlinear characteristics of the BARC system. Free vibration testing with an impact hammer was carried out to excite the system and extract the dominant frequencies and directions of the significant responses. A pseudorandom vibration test that allows for the qualitative determination of any nonlinear behavior within the system was performed. This type of behavior can include nonlinear softening, nonlinear hardening, and the most common, nonlinear damping due to the presence of several bolted-joint connections and the possible activation of geometric and inertia nonlinearities. To quantitatively investigate the impacts of the central-cut width on the dynamics of the system, swept sinusoidal testing was conducted. It is determined that almost all systems with central cuts demonstrate the presence of nonlinear softening, but at times, nonlinear hardening trends are seen, particularly in the 0.1″ cut and no-cut systems when testing harmonically. Each of the central-cut systems displays nonlinear damping, with the amount of damping generally increasing as the central cut decreases in size. The effect of the central cut of the BARC system on the mode-switching ability of the system is negligible; however, mode switching takes place when comparing the central-cut configurations to the no-cut one. These results show the significance of accurately measuring the central-cut width and how geometric uncertainty may change the dynamical responses and nonlinear properties of the system.

Padilla, Christopher (ORCID:000900033446732X)↗

Distributed Finite-Time Termination for Consensus Algorithm in Switching Topologies

Here, in this article, we present a finite-time stopping criterion for consensus algorithms in networks with dynamic communication topology. Prior state of the art has established convergence to the consensus value; however, the asymptotic convergence of these algorithms poses a challenge in practical settings where the response from agents is required in finite time. To this end, we propose a maximum-minimum protocol that propagates the global maximum and minimum values of agent states (while running the consensus algorithm) in the network. This article focuses on establishing that the global maximum and minimum values are strictly monotonic even for a dynamic topology, and they can be used to distributively ascertain the closeness to convergence in finite time. We rigorously show that each node can have access to the global maximum and minimum by running the proposed maximum-minimum protocol to realize a finite-time stopping criterion for the otherwise asymptotic consensus algorithm. The practical utility of the algorithm is illustrated through experiments where each agent is instantiated by a NodeJS socket.io server.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-frequency switching voltage regulators for terrestrial photovoltaic systems

The photovoltaic technology project and the stand alone applications project are discussed. Two types of low frequency switching type regulators were investigated. The design, operating characteristics and field application of these regulators is described. The regulators are small in size, low in cost, very low in power dissipation, reliable and allow considerable flexibility in system design.

Delombard, R.↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan K.↗

Control-inspired design and power optimization of an active mechanical motion rectifier based power takeoff for wave energy converters

Ocean waves have high energy density and are persistent and predictable. Yet, converting wave energy to a useable form remains challenging. A significant hurdle is the oscillatory nature of waves resulting in the alternating loads, which necessitate the use of rectification at some stage of the energy conversion. This research effort presents a novel design of active mechanical motion rectifier (AMMR) for the power takeoff (PTO), which provides enhanced controllability and better power performance when compared to passive mechanical motion rectifiers (MMR). Inspired by transistors used in synchronous electrical rectifiers, the proposed design uses controllable electromagnetic clutches in the mechanical transmission to allow active engagement-disengagement control; thus, rectifying the oscillatory motion into a unidirectional rotation for high energy conversion efficiency and allowing the generator in unidirectional rotation to control the bidirectional wave capture structure for maximizing the power output. A semi-analytical computational approach is developed to efficiently evaluate the optimal power achieved using the proposed AMMR-based PTO and active control. It is found that the AMMR-based PTO design yields a higher optimal power than the previous passive MMR design across the wave spectrum. The influences of generator inertia and reactive power are discussed. Furthermore, the effects of control parameters on the power output and the optimal trajectories are analyzed. Wave tank tests with the AMMR prototype demonstrated the effectiveness of AMMR based PTO design and validated the numerical analysis.

16 TIDAL AND WAVE POWER↗

Exact Coherent Structures and Phase Space Geometry of Preturbulent 2D Active Nematic Channel Flow

Confined active nematics exhibit rich dynamical behavior, including spontaneous flows, periodic defect dynamics, and chaotic “active turbulence.” Here, we study these phenomena using the framework of exact coherent structures, which has been successful in characterizing the routes to high Reynolds number turbulence of passive fluids. Exact coherent structures are stationary, periodic, quasiperiodic, or traveling wave solutions of the hydrodynamic equations that, together with their invariant manifolds, serve as an organizing template of the dynamics. We compute the dominant exact coherent structures and connecting orbits in a preturbulent active nematic channel flow, which enables a fully nonlinear but highly reduced-order description in terms of a directed graph. Using this reduced representation, we compute instantaneous perturbations that switch the system between disparate spatiotemporal states occupying distant regions of the infinite-dimensional phase space. Overall, our results lay the groundwork for a systematic means of understanding and controlling active nematic flows in the moderate- to high-activity regime.

36 MATERIALS SCIENCE↗

High throughput battery failure experimental platform

Addressing the need to increase the sample set to understand the causes of lithium battery thermal runaway, we conceived of an experimental platform with capability to increase the number of runaway experiments (currently 3-5 per week), while also collecting detailed electrochemical impedance spectroscopy measurements (EIS). Once expanded, the platform would enable data collection on 10s to 100s of cells that all experience runaway, thereby creating a statistical database necessary to identify early indication of risk. A primary containment unit to house cylindrical cells of variety NMC811 and of size 21700 (21 mm diameter by 70 mm length) was designed with features such as debris containment, preloaded cells in an exchangeable port, nitrogen ventilation, and exhaust containment. We performed the first overcharge abuse experiments of several 21700 cells, handpicked because of different initial EIS, and demonstrated that EIS changes dramatically during early stages of overcharge, but in a different manner than previous pouch cell experiments. The abuse experiments also revealed the discharge pattern and debris field created during runaway, as well as the cell temperature control and overheat, that must be considered in the primary containment apparatus. We designed and built a switching relay system to permit measurement of EIS without an active charging circuit, and created instrument control software for charging, EIS, and cell temperature control. The late-start funding was insufficient to fully construct the primary containment unit, but the foundational design and knowhow is available for any future work.

25 ENERGY STORAGE↗

The spacecraft power supply system

The power supply system in the Telstar spacecraft consists of a solar cell plant to convert solar radiation to electrical energy when the satellite is illuminated by the sun, a 19-cell nickel-cadmium battery to store energy, and a regulation circuit to supply constant output voltages over a wide variation in input voltages. Additionally, the power supply system provides switching to conserve power and allow battery recharging during periods between communications experiments.

POWER SUPPLY↗