Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Steam Generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Predicting Rupture Pressure and Leak Rate of Alloy 600 U-bend Tubes with PWSCC and Comparing with Test Results (Technical Letter Report)

This report summarizes structural integrity work performed for the US NRC that predicts the structural integrity of steam generator (SG) tubes with flaws in the U-bend. The work covers model development and validation for U-bend tubes containing lab-induced primary water stress corrosion cracks (PWSCC). Limit load models for plastic collapse predicting ligament rupture pressure and leak rate of cracked U-bend tubes were developed and validated with pressure tests and finite element analyses (FEAs). Failure pressure and leak rate tests were conducted at room temperature on Alloy 600 U-bend tubes containing flaws located at various locations around the U-bend. Existing models for predicting structural integrity of straight tubes with well defined, rectangular, electro-discharge-machined (EDM) flaws were modified and used to predict the ligament rupture and unstable burst pressures as well as leak rates for the PWSCC flaws in the U-bend section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DTK C/Fortran Interface Development for NEAMS FSI Simulations

This report documents the development of DataTransferKit (DTK) C and Fortran interfaces for fluid-structure-interaction (FSI) simulations in NEAMS. In these simulations, the codes Nek5000 and Diablo are being coupled within the SHARP framework to study flow-induced vibration (FIV) in reactor steam generators. We will review the current Nek5000/Diablo coupling algorithm in SHARP and the current state of the solution transfer scheme used in this implementation. We will then present existing DTK algorithms which may be used instead to provide an improvement in both flexibility and scalability of the current SHARP implementation. We will show how these can be used within the current FSI scheme using a new set of interfaces to the algorithms developed by this work. These new interfaces currently expose the mesh-free solution transfer algorithms in DTK, a C++ library, and are written in C and Fortran to enable coupling of both Nek5000 and Diablo in their native Fortran language. They have been compiled and tested on Cooley, the test-bed machine for Mira at ALCF.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety Analyses of Design Basis and Design Extended Condition Events for the PGSFR

KAERI (Korea Atomic Energy Research Institute) has been developing the PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor), which is a pool type sodium-cooled fast reactor with the thermal power of 392.2 MWt, uses metallic fuel of U-10%Zr for a core. The preliminary specific design of PGSFR is completed in 2015. The main parts of PGSFR consist of PHTS (Primary Heat Transport System), IHTS (Intermediate Heat Transport System), two SG (Steam Generator), and DHRS (Decay Heat Removal System). The main feature of PGSFR in safety is from the adoption of metallic fuel core, leading to inherent reactivity feedback mechanisms and high thermal conductivity. In this work, safety analysis on DBE (Design Basis Event) and DEC (Design Extended Condition event) for PGSFR preliminary specific design is conducted using MARS-LMR code. Conservative and best-estimated approaches are applied to DBA and DEC, respectively. It is found that the most severe accidents in the AOO, DBA class 1, DBA class 2, and DEC are LOF, OPS, TOP and ULOF event, respectively. And all analysis results are found to meet safety acceptance criteria requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models

Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integral Effect Test of ATLAS Facility on Multiple Failure in a Prolonged Station Blackout

Since the Fukushima accident, the design extension conditions (DECs) in a nuclear power plant (NPP) have attracted more importance with respect to nuclear reactor safety, and a consensus has been developed such that these high-risk multiple failure accidents should be revisited from the viewpoint of a reinforcement of the 'defense in depth' concept. In particular, a station blackout (SBO) is one of the most important DECs because a loss of the heat sink without an appropriate accident measure might lead to a core uncovery, core damage, and ultimately, a core meltdown under high pressure. SBO has been recognized to be one of the risk-contributing sequences when combined with additional failure of components such as a reactor coolant pump (RCP) seal leakage or a steam generator tube rupture (SGTR). The RCP seal failure could occur due to a loss of continuous cooling through the seal during SBO. The SGTR during SBO can be a potentially important risk due to the release of the fission product with bypassing the containment boundary. The objective of this study is to experimentally simulate and analyze a prolonged SBO scenario in a thermal hydraulic integral effect test facility, ATLAS. As test items in OECD-ATLAS project, two tests for the SBO condition were conducted with additional failures, that is, a RCP seal failure (A2.1 test) and a SGTR (A2.2 test). In those tests, both the effect of the additional failure on reactor safety and the natural circulation characteristics during prolonged SBO conditions could be investigated. The present test can provide physical insight into the system response during the prolonged SBO scenario combined with the multiple failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cogeneration of electricity and liquid fuels using an HTGR as the heat source - 18698

A high temperature gas-cooled reactor (HTGR) used for cogeneration of electricity and liquid transportation fuels was modeled. The model consisted of two HTGRs, each transferring heat through: - a steam generator (SG) to a supercritical Rankine Cycle (SCRC) producing electricity, and - an intermediate heat exchanger (IHX) to a biomass gasifier and Fischer-Tropsch (FT) process producing gasoline, jet fuel, diesel, liquefied petroleum gas (LPG) and/or naphtha. The individual systems and components in the cogeneration model are mature technologies and commercially available, because minimizing the need for additional innovation increases the overall probability of success for a new and unique hybrid system. Technical evaluations of cogeneration on the island of Oahu in the State of Hawaii, using eucalyptus and sugarcane as the biomass feedstock, indicated that high thermal efficiency was achievable and that the concept is technically viable. Economic evaluations of cogeneration, based on construction and finance costs and current electricity and liquid fuel prices, indicated that the cogeneration plant is economically viable. Additional analyses quantified the potential number of jobs created in the state and the reduction in carbon emissions. Further analyses indicated that cogeneration would significantly enhance Hawaii's energy security. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical Simulation of Isothermal Flow Across Slant Five-Tube Bundle with Spectral Element Method Code Nek5000

The helical coil steam generator (HCSG) is a specific type of shell-and-tube heat exchanger known for having a higher heat transfer coefficient than many other designs. For this reason, they are considered in small modular reactor and high temperature reactor designs. Investigation of flow behavior in HCSGs is important for better design. In this paper we present our study for modeling the coolant flow in the primary side of the HCSG. We used Nek5000, an open source, high-order spectral element computational fluid dynamics code developed in Argonne National Laboratory. Nek5000 accepts only hexahedral mesh, which makes the meshing process for the complicated HCSG geometry very challenging. A tetrahedral-to-hexahedral meshing strategy was applied to bypass the geometric complexities. In this study large eddy simulation (LES) was performed at the Reynolds number of 9000 based on the inlet velocity and the tube diameter. The employed subgrid-scale model for LES relies on explicit filtering. First- and second-order statistics were compared to available experimental data. We report overall velocity and turbulent kinetic energy showed good agreement with particle image velocimetry data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characteristics Analysis of SGTR accidents under the Shutdown Conditions

The Steam Generator Tube Rupture (SGTR) accident is one of design basis accidents that could result in undesirable radiation release as it bypasses the containment. According to Ref. [1], SGTRs have been experienced in several nuclear power plants and Ulchin 4 of Korea is one of them. Basically, SGTR analysis assumes that it occurs at full power, the SGTR at Ulchin 4 in 2002, was in the shutdown condition. Therefore, the transient behavior was different from the cases in full power conditions and especially, the effectiveness of Emergency Operating Procedure (EOP) needs to be checked if it is also applicable to the shutdown conditions, because EOP is prepared for full power conditions. In this paper, we set up a MARS-KS code model for Ulchin 4 unit and simulated the SGTR accident for benchmarking the model to the actual plant behavior during the accident. And then, several case studies were done to investigate the consequence of SGTR and the effectiveness of the EOP, focusing on the amount of the primary to secondary discharge flow which was influenced by operator actions. At the end, we'll discuss about the EOP for the shutdown conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Semi-Empirical Correlation for Counter-Current Flow Limitation in a Vertical Pipe

Counter-current two-phase flows may take place in the steam generator of a pressurized water reactor (PWR) during a reflux-cooling mode. Therefore developing reliable correlations of counter-current flow limitation (CCFL) is of great importance in safety analyses. Wallis derived a CCFL correlation, which is expressed in terms of the so-called Wallis parameters, which are the dimensionless gas and liquid volumetric fluxes. Although effects of the fluid properties are not sufficiently accounted for in this correlation, he introduced the inverse liquid viscosity number into it to account for the viscous effect on CCFL . The functional form of the factor for the viscous effect was however empirically determined without physical grounds. Zapke and Kroeger proposed an empirical CCFL correlation by introducing the Ohnesorge number into the original Wallis correlation to account for the effects of the liquid viscosity and surface tension on CCFL. The effects of the fluid properties have been thus added in the original Wallis correlation in an empirical manner. In this study, a semi-empirical correlation for CCFL in a vertical pipe is derived from one-dimensional equations for a steady counter-current annular two-phase flow in a vertical pipe. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The MELCOR Analysis of Chinshan Nuclear Power Plant Spent Fuel Pool for Fukushima-like Accident

The safety analysis of the nuclear power plant (NPP) is very important work in the NPP safety. Especially after the Fukushima NPP accident occurred, the importance of NPP safety analysis has been raised and there is more concern for the safety of NPPs in Taiwan. Because the earthquake and tsunami occurred, the cooling system of spent fuel pool failed and the safety issue of spent fuel pool generated in Japan's Fukushima NPP. Chinshan NPP is the first NPP in Taiwan which is BWR/4 plant and OLTP (Original Licensed Thermal Power) for each unit is 1775 MWt. Chinshan NPP finished SPU (stretch power uprate) and the operating power is 103.66% of the OLTP, which is 1840 MWt now. After Fukushima NPP accident occurred, in order to concern the safety of Chinshan NPP spent fuel pool, we performed the safety analysis of spent fuel pool by using MELCOR/SNAP which also assumed the cooling system of spent fuel pool failed. The geometry of Chinshan NPP spent fuel pool is 12.17 m x 7.87 m x 11.61 m and the initial condition is 60 deg. (water temperature) / 1.013 x 10{sup 5} Pa. And, the total power of the fuels is roughly 8.9 MWt initially. MELCOR is developed by Sandia National Laboratories. MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor NPPs, including containment response and leakage of activity to the environment. A broad spectrum of severe accident phenomena in both BWRs and PWRs is treated in MELCOR in a unified framework. These include thermalhydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. According to Dr. Carbajo's paper, MELCOR was used to perform the study of spent fuel pool of Fukushima Daiichi Unit 4. Niina E. Koenoenen used MELCOR to establish the spent fuel pool model of a Nordic BWR. The loss-of-pool-cooling accidents was simulated and analyzed by this model. The above studies indicate that MELCOR is capable of handling the simulation of the spent fuel pool. An increasing number of researchers are using MELCOR code to analyze test facilities and nuclear power plants. Jun Wang et al. used MELCOR to perform core degradation simulation and MELCOR results were compared with CORA experimental data. Through this work, they reviewed the performance of MELCOR COR package in detail. Tae Woon Kim et al. developed MELCOR model of APR1400 (an advanced pressurized water reactor). They used this model to perform the LBLOCA transient simulation and sensitivity study. Longze Li et al. established the MELCOR model of CPR1000 (a Chinese pressurized reactor 1000-MW power plant). The station blackout (SBO) with failure of the steam generator (SG) safety relief valve (SRV) transient was simulated and analyzed by this model. SNAP is a graphic user interface program that processes the inputs and outputs of MELCOR. In addition, there is an animation function in SNAP which can present the animation of analysis results. There are two main steps in this research. The first step was the establishment of Chinshan NPP spent fuel pool MELCOR/SNAP model. And the transient analysis of Chinshan NPP spent fuel pool MELCOR/SNAP model under the cooling system failure condition was performed. The next step was the comparison among the MELCOR, TRACE and CFD data. TRACE and CFD data were from INER reports. In addition, the animation model of Chinshan NPP spent fuel pool was presented by using the animation function of SNAP with MELCOR/SNAP analysis results. This study has developed MELCOR/SNAP model of Chinshan NPP spent fuel pool successfully. By using the above model, the safety analysis of the spent fuel pool was performed under the cooling system of spent fuel pool failed condition. The analysis results of MELCOR, TRACE and CFD were similar in this case. It indicated that there was a respectable accuracy in MELCOR/SNAP model. The analysis results depicted that the uncovered of the fuels occurred at 2.6 day and the metal-water reaction of fuels occurred roughly at 3.7 day after the cooling system failed. The above results indicated that the failure of cladding occurred after 3.7 day. This study's results can help to evaluate the safety issue of Chinshan NPP spent fuel pool. In addition, the cooling system and some mitigation measures of spent fuel pool is not simulated in the above model. However, we will do it in the future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Science-based HRA: experimental comparison of operator performance to IDAC (Information-Decision-Action Crew) simulations

Information-Decision-Action Crew (IDAC) operator model simulations of a Steam Generator Tube Rupture are compared to student operator performance in studies conducted in the Ohio State University’s Nuclear Power Plant Simulator Facility. This study is presented as a prototype for conducting simulator studies to validate key aspects of Human Reliability Analysis (HRA) methods. Seven student operator crews are compared to simulation results for crews designed to demonstrate three different decision-making strategies. The IDAC model used in the simulations is modified slightly to capture novice behavior rather that expert operators. Operator actions and scenario pacing are compared. A preliminary review of available performance shaping factors (PSFs) is presented. After the scenario in the NPP Simulator Facility, student operators review a video of the scenario and evaluate six PSFs at pre-determined points in the scenario. This provides a dynamic record of the PSFs experienced by the OSU student operators. In this preliminary analysis, Time Constraint Load (TCL) calculated in the IDAC simulations is compared to TCL reported by student operators. We identify potential modifications to the IDAC model to develop an “IDAC Student Operator Model.” This analysis provides insights into how similar experiments could be conducted using expert operators to improve the fidelity of IDAC simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulations of a Helical Tube Bundle in Cross-Flow for Application to Flow-Induced Vibration

Helical tubes have been used in a number of systems, including the energy and chemical processing industries. Helical-Coil Steam Generators (HCSGs) in particular have special application in systems for which spatial constraints are important. Variants of these designs are notably included in a number of integral-vessel small modular reactor (SMR) designs which are currently in development by multiple companies. These designs typically have the primary side located within the vessel, with the secondary side flowing upward through the helical tubes. One complexity in implementing an HCSG within the reactor pressure vessel is that any potential flow-induced vibration (FIV) can impact reactor safety. In a typical power plant, heat exchanger tube failures caused by FIV can be costly, but generally do not have immediate impact on the core safety due to their relative isolation from the core area. In an integral-vessel design, a tube rupture could eject material from the secondary side into the primary flow, potentially damaging the core itself or other crucial components. Thus a higher degree of confidence in predicting and/or preventing FIV should be attained for implementing the helical tubes in these designs. A significant campaign is currently underway to address the topic of FIV in helical tube arrays. The U.S. Department of Energy, under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) initiative, has deemed this a 'high-impact problem'. This will include both experimental and computational contributions from a consortium consisting of multiple universities, industry partners, and national laboratories, including Argonne National Laboratory. The primary industrial partner is NuScale, which will see direct benefits from this initiative to the development of their SMR and its component design. The primary focus of this paper is to establish some of the computational efforts that have been made to this stage and the initial benchmarking of computational tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

The ATWS analysis of the HTR-10GT core induced by the earthquake - 18489

The 10 MW High Temperature Gas Cooled Test Reactor (HTR-10) has been built in Institute of Nuclear and New Energy Technology (INET) and has been operating successfully since the beginning of 2003. The core outlet temperature of HTR-10 is 700 deg. C. To verify the technology of gas-turbine direct cycle, at first INET had a plan to increase its core outlet temperature to 750 deg. C and use a helium gas turbine instead of the steam generator (then the reactor is called HTR-10GT). Though HTR-10 has good intrinsic safety, the design basic accidents and beyond design basis accidents of HTR-10GT must be analyzed according to China s nuclear regulations due to changed operation parameters. THERMIX code system is used to study the Anticipated Transient Without Scram (ATWS) caused by an earthquake. The gravity acceleration of the earthquake will make the porosity of the pebble bed smaller, which will thus induce a positive reactivity. The packing fraction of the HTR-10GT core will increase to 0.64 from 0.61, while a reactivity of 1.24% will be inserted into an initial core and 0.788% for an equilibrium core. Then the reactor power increased and the temperature of the core increased. When the neutron flux of power measuring range exceeded 123% and the reactor period becomes less than 20 seconds, the reactor should scram. It was supposed that all the control rods in the reflectors had been blocked and the reactor could not scram. Thus the accident went on and the core temperature and the system pressure increased but the reactor shutdown at last because of its natural negative temperature reactivity feedback mechanism. The residual heat would be removed out of the core by the cavity cooling system. During the accident sequence the maximum fuel temperature was 1223 deg. C. If a temperature coefficient error of 20% was considered during analyzing, the peak temperature of the fuel during the ATWS will reach 1266 deg. C. It was a little higher than 1230 deg. C --the fuel temperature limitation of HTR-10. Now the sphere fuel used in HTR-10GT will also be used in HTR-PM and the temperature limitation has been raised to 1620 deg. C, so the HTR-10GT is safe during the ATWS caused by an earthquake. The paper also compares the analysis result of HTR10-GT to those of HTR-10. The results shows that the HTR-10GT is still safe during the accident though its operating temperature is higher than HTR-10. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Density Effects on Lock Exchange Flow During a DCC

The High Temperature Test Facility (HTTF) is a scaled, electric model at Oregon State University (OSU) of the Modular High Temperature Gas Reactor (MHTGR) by General Atomics. There are a few major differences between the design and the OSU facility. In the HTTF the reactor pressure vessel and the reactor cavity are in two separate tanks connected by a crossover duct similar to the crossover duct that would be seen between the reactor core and the steam generator in the MHTGR. This feature allows for the facility to open two main break valves simulating a Double-Ended Guillotine Break (DEGB) of the cross over duct, synonymous to a crossover duct break in the MHTGR. The density gradient driven flow phenomena in the HTTF duct can then be studied further. This break would cause a depressurization of the reactor and a loss of flow. It is called the Depressurized Loss of Forced Convection Accident (D-LOFC), also known as the Depressurized Conduction Cool-Down Event for High Temperature Gas Reactors (HTGRs) because heat removal is by conduction through the core and radiation out of the vessel. The HTTF was built and scaled to maintain the highest accuracy for the DCC. Prototypical temperatures with an inlet temperature of 259 deg. C and an outlet temperature of 687 deg. C are maintained in the HTTF. The temperature profile is also maintained in the smaller volume by using a ceramic core. The HTTF uses graphite heaters because the resistive heat produced does not change significantly with temperature . In order to produce a facility of similar temperatures within the allotted budget, sacrifices had to be made in other areas. The HTTF is scaled one-fourth in diameter, one-fourth in height and one-eighth in pressure of the MHTGR. There are also a few limitations for the HTTF. While in the MHTGR, the cavity is filled with air, the HTTF uses highly pure Nitrogen and does not have the ability to simulate a full depressurization. The DCC event is traditionally comprised of multiple stages: depressurization, molecular diffusion and natural circulation. However, this traditional interpretation ignores lock exchange flow which will occur immediately following depressurization and could have significant consequences in the reactor. It was found that the traditional model underestimates the amount of air ingress by at least 660 times according to Oh and Kim in their theoretical research of air ingress. Molecular diffusion also decreases with stratification. Any model that specifies the gases are stratified has further underestimated the air ingress of the DCC event. In addition, molecular diffusion is a much slower process, allowing the reactor to shut down and cool off considerably from operating temperatures. Thus, understanding lock exchange flow, the air ingress concentrations and the time scale is critical to MHTGR research and licensing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗