Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Machining Specific Fourier Power Spectrum Profiles into Plastics for High Energy Density Physics Experiments [Machining Specific Fourier Power Spectrum Profiles into Plastics for HEDP Experiments]

In this paper, the High Energy Density Physics program at Los Alamos National Laboratory (LANL) has had a multiyear campaign to verify the predictive capability of the interface evolution of shock propagation through different profiles machined into the face of a plastic package with an iodine-doped plastic center region. These experiments varied the machined surface from a simple sine wave to a double sine wave and finally to a multitude of different profiles with power spectrum ranges and shapes to verify LANL’s simulation capability. The MultiMode-A profiles had a band-pass flat region of the power spectrum, while the MultiMode-B profile had two band-pass flat regions. Another profile of interest was the 1-Peak profile, a band-pass concept with a spike to one side of the power spectrum. All these profiles were machined in flat and tilted orientations of 30 and 60 deg. Tailor-made machining profiles, supplied by experimental physicists, were compared to actual machined surfaces, and Fourier power spectra were compared to see the reproducibility of the machining process over the frequency ranges that physicists require.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interannual consistency of migration phenology is season- and breeding region-specific in North American Golden Eagles

Abstract Interannual consistency (an indicator of the strength of adjustments) in migration phenology of Golden Eagles (Aquila chrysaetos) in North America is most strongly associated with the breeding region, the season, and with late-season temperature on breeding and wintering grounds. Consistency was greatest in boreal spring migration and the breeding regions of eastern Canada. Using multi-year GPS tracks of 83 adults breeding in 3 spatially distant regions (Alaska, northeast Canada, and southeast Canada), we quantified the interannual consistency of migration phenology and wintering latitude within and among individuals tracked across multiple years and the repeatability (r) by breeding regions and seasons. By comparing regions and seasons, we found that consistency was highest (r > 0.85) for boreal spring migration in eastern Canada while Alaska had the lowest value (r < 0.15). Because seasonal consistency of migration phenology was only detected in eastern Canada, we conclude that seasonal features are not a primary constraint. While regional differences in consistency were not related to differences in migratory distances, they could be the result of genetic or habitat differences. We also found that temperatures warmer than the decadal average at the region of departure delayed the start of boreal spring migration by ~10 days and advanced boreal autumn migration by ~20 days. These results suggest that warmer temperatures would reduce residence time on breeding grounds, contrary to expectations and trends found in other studies. Wide variations in migratory strategies across a species distribution can add to the list of challenges for conservation but may give migrants the capacity to acclimate to environmental changes.

Zoology↗

Component-specific electromechanical response in a ferroelectric/dielectric superlattice.

The electronic and electromechanical properties of complex oxide superlattices are closely linked to the evolution of the structure and electrical polarization of the component layers in applied electric fields. Efforts to deduce the responses of the individual components of the superlattice to applied fields have focused on theoretical approaches because of the limitations of available experimental techniques. Time-resolved x-ray microdiffraction provides a precise crystallographic probe of each component using the shift in wave vector and change in intensity of superlattice satellite reflections. We report in detail the methods to measure and analyze the x-ray diffraction patterns in applied electric field and their application to a 2-unit-cell BaTiO{sub 3}/4-unit-cell CaTiO{sub 3} superlattice. We find that the overall piezoelectric distortion is shared between the two components. Theoretical predictions of the electromechanical properties of a superlattice with the same composition constrained to tetragonal symmetry are in excellent agreement with the experiments. Lattice instability analysis, however, suggests that the low-temperature ground state could exhibit antiferrodistortive rotations of TiO{sub 6} octahedra within and/or at the interfaces of the CaTiO{sub 3} component.

36 MATERIALS SCIENCE↗

CBCT with specification of imaging dose and CNR by anatomical volume of interest

Purpose: A novel method has been developed for volume of interest (VOI) cone-beam CT (CBCT) imaging using a 2.35 MV/Carbon target linac imaging beam line combined with dynamic multileaf collimator sequences. Methods: The authors demonstrate the concept of acquisition of multiple, separate imaging volumes, where volumes can be either completely separated or nested, and are associated with predetermined imaging dose and contrast-to-noise ratio (CNR) characteristics. Two individual MLC sequences were established in the planning system (Eclipse, Varian Medical) to collimate the beam according to a defined inner VOI (e.g., containing a target volume under image guidance) and an outer VOI (e.g., including surrounding landmarks or organs-at-risk). MLC sequences were interleaved as a function of gantry angle to produce a reconstructed CBCT image with nested VOIs. By controlling the ratio of inner-to-outer ratio of MLC segments (and thus Monitor Units) during acquisition, the relative dose and CNR in the two volumes can be controlled. Inner-to-outer ratios of 2:1 to 6:1 were examined. Results: The concept was explored using an anatomical head phantom to assess image quality. A geometric phantom was used to quantify absolute dose and CNR values for the various sequences. The authors found that the dose in the outer VOI decreased by a functional relationship dependent on the inner-to-outer sequence ratio, while the CNR varied by the square root of dose, as expected. Conclusions: In this study the authors demonstrate flexibility in VOI CBCT by tailoring the imaging dose and CNR distribution in separate volumes within the patient anatomy. This would allow for high quality imaging of a target volume for alignment purposes, with simultaneous low dose imaging of the surrounding anatomy (e.g., for coregistration)

62 RADIOLOGY AND NUCLEAR MEDICINE↗