Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Replacing fish oil and astaxanthin by microalgal sources produced different metabolic responses in juvenile rainbow trout fed 2 types of practical diets

Dietary fish oil supplementation provides n-3 long-chained polyunsaturated fatty acids for supporting fish growth and metabolism and enriching fillet with eicosapentaenoic acid (EPA; 20:5n-3) and docosahexaenoic acid (DHA; c22:6n-3). Two experiments were performed as a 3 × 2 factorial arrangement of dietary treatments for 16 wk to determine effects and mechanisms of replacing 0%, 50%, and 100% fish oil with DHA-rich microalgae in combination with synthetic vs. microalgal source of astaxanthin in plant protein meal (PM)- or fishmeal (FM)- based diets for juvenile rainbow trout (Oncorhynchus mykiss). Fish (22 ± 0.26 g) were stocked at 17/tank and 3 tanks/diet. The 100% fish oil replacement impaired (P < 0.0001) growth performance, dietary protein and energy utilization, body indices, and tissue accumulation of DHA and EPA in both diet series. Here, the impairments were associated (P < 0.05) with upregulation of hepatic gene expression related to growth (ghr1and igf1) and biosynthesis of DHA and EPA (fads6 and evol5) that was more dramatic in the FM than PM diet-fed fish, and more pronounced on tissue EPA than DHA concentrations. The source of astaxanthin exerted interaction effects with the fish oil replacement on several measures including muscle total cholesterol concentrations. In conclusion, replacing fish oil by the DHA-rich microalgae produced more negative metabolic responses than the substitution of synthetic astaxanthin by the microalgal source in juvenile rainbow trout fed 2 types of practical diets.

59 BASIC BIOLOGICAL SCIENCES↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used in the reconstruction process. Conclusions: The concept of assessing temporal resolution by means of the data employed for reconstruction can nicely be extended from single-source to dual-source CT. However, for advanced (possibly nonlinear iterative) reconstruction algorithms the examined approach fails to deliver accurate results. New methods and measures to assess the temporal resolution of CT images need to be developed to be able to accurately compare the performance of such algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic Source Localization via Time Difference of Arrival Estimation for Distributed Sensor Networks Using Tera‐Scale Optical Core Devices

For real‐time acoustic source localization applications, one of the primary challenges is the considerable growth in computational complexity associated with the emergence of ever larger, active or passive, distributed sensor networks. These sensors rely heavily on battery‐operated system components to achieve highly functional automation in signal and information processing. In order to keep communication requirements minimal, it is desirable to perform as much processing on the receiver platforms as possible. However, the complexity of the calculations needed to achieve accurate source localization increases dramatically with the size of sensor arrays, resulting in substantial growth of computational requirements that cannot be readily met with standard hardware. One option to meet this challenge builds upon the emergence of digital optical‐core devices. The objective of this work was to explore the implementation of key building block algorithms used in underwater source localization on the optical‐core digital processing platform recently introduced by Lenslet Inc. This demonstration of considerably faster signal processing capability should be of substantial significance to the design and innovation of future generations of distributed sensor networks.

Imam, Neena↗

Mapping Correlation of a Simulated Dark Matter Source and a Point Source in the Gamma-Ray Sky - Oral Presentation [Slides]

In my research, I analyzed how two gamma-ray source models interact with one another when optimizing to fit data. This is important because it becomes hard to distinguish between the two point sources when they are close together or looking at low energy photons. The reason for the first is obvious, the reason why they become harder to distinguish at lower photon energies is the resolving power of the Fermi Gamma-Ray Space Telescope gets worse at lower energies. When the two point sources are highly correlated (hard to distinguish between), we need to change our method of statistical analysis. What I did was show that highly correlated sources have larger uncertainties associated with them, caused by an optimizer not knowing which point source’s parameters to optimize. I also mapped out where their is high correlation for 2 different theoretical mass dark matter point sources so that people analyzing them in the future knew where they had to use more sophisticated statistical analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverting infrasound data for the seismoacoustic source time functions and surface spall at the Source Physics Experiments Phase II: Dry Alluvium Geology

This report presents the infrasound data recorded as part of the Source Physics Experiment - Phase 2, Dry Alluvium Geology. This experiment, also known colloquially as DAG, consisted of four underground chemical explosions at the Nevada National Security Site. We focus our analysis on only the fourth explosion (DAG-4) as we determined that this was the only event that produced clear source-generated infrasound energy as recorded by the DAG sensors. We analyze the data using two inversion methods. The first method is designed to estimate the point-source seismoacoustic source time functions, and the second inversion method is designed to estimate the first-order characteristics (e.g. horizontal dimensions and maximum amplitude) of the actual spall surface. For both analysis methods, we are able to fit the data reasonably well, with various assumptions of the source model. The estimated seismoacoustic source appears to be a combination of a buried, isotropic explosion with a maximum amplitude of ~2 x 10 9 Nm and a vertically oriented force, applied to the Earth's surface with a maximum amplitude of 4 x 10 7 N. We use the vertically oriented force to simulate surface spall. The estimated spall surface has an approximate radius of ~40 m with a maximum acceleration magnitude in the range of 0.8 to 1.5 m/s/s. These estimates are approximately similar to the measured surface acceleration at the site.

58 GEOSCIENCES↗

All-sky Search for Time-integrated Neutrino Emission from Astrophysical Sources with 7 yr of IceCube Data

Since the recent detection of an astrophysical flux of high-energy neutrinos, the question of its origin has not yet fully been answered. Much of what is known about this flux comes from a small event sample of high neutrino purity, good energy resolution, but large angular uncertainties. In searches for point-like sources, on the other hand, the best performance is given by using large statistics and good angular reconstructions. Track-like muon events produced in neutrino interactions satisfy these requirements. We present here the results of searches for point-like sources with neutrinos using data acquired by the IceCube detector over 7 yr from 2008 to 2015. The discovery potential of the analysis in the northern sky is now significantly below E{sub ν}{sup 2}dϕ/dE{sub ν} = 10{sup −12} TeV cm{sup −2} s{sup −1}, on average 38% lower than the sensitivity of the previously published analysis of 4 yr exposure. No significant clustering of neutrinos above background expectation was observed, and implications for prominent neutrino source candidates are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Uhuru observations of 4U 1608-52 - The 'steady' X-ray source associated with the X-ray burst source in Norma

Data are presented for the X-ray source 4U 1608-52, summarizing its light curve, location, and spectral parameters. Evidence is presented showing that this source is the 'steady' X-ray counterpart of the X-ray burst source in Norma. The spectrum of the 'steady' source is compared with the spectrum observed during two bursts, and it is noted that there is substantially more low-energy absorption during the bursts. The 'steady' source spectral data are used to examine the optical data, and it is concluded that if the X-ray spectrum is thermal, then a globular-cluster counterpart probably would have been detected (whereas none has been). Further X-ray and optical observations are suggested for this source, since an optical identification may be central in determining whether all X-ray bursts have a common origin and if this origin requires a globular-cluster environment.

Tananbaum, H.↗

Transfer of polarized radiation in self-absorbed synchrotron sources. I - Results for a homogeneous source

The solution to the equation of transfer of polarized radiation in a steady-state homogeneous rarefied medium is applied to self-absorbed synchrotron sources. Relativistic electrons (independent of the presence of any cold plasma) can quite easily produce in such sources significant Faraday rotation and/or conversion of linear to circular polarization. Structural inhomogeneities do not obviate the importance of these phenomena in compact nonthermal sources. Contrary to the calculation of Pacholczyk and Swihart (1975), the circular polarization for a homogeneous source changes sign just below the self-absorption turnover as the source becomes opaque, even when polarization conversion dominates; however, for a physically realistic source, structural inhomogeneity may alter this behavior. The observational evidence bearing upon these effects is reviewed.

Jones, T. W.↗

A new method of measuring radio source parameters of a partially polarized distributed source from spacecraft observations

An experimental system is analyzed which is designed to determine the angular and polarization properties of low frequency radio sources from measurements made on a spinning spacecraft. The system has been optimized to provide high accuracies for sources at high as well as low elevation angles. Theoretical expressions are derived for the response of this system to a partially polarized point source. Integrations are then carried out to get the system response to a uniform circular distributed source. Data processing techniques are derived so that computer simulations can be carried out to investigate the accuracy of this technique. It is shown that using 24 measurements of a partially polarized source (with Q = U = V = 0.5), taken in one spacecraft rotation, the resulting rms errors in angular position are less than one degree and the errors in determining the Stokes parameters are generally 1-10% for a wide range of source elevations.

Manning, R.↗

Far-infrared sources in Cygnus X - An extended emission complex at DR 21 and unresolved sources at S106 and ON 2

A new map of 90 micron emission with 15 arcmin resolution is presented of a complex of sources approximately centered on DR 21. The emission is primarily from diffuse sources. Comparison of the 90 micron map with maps at 20 microns and 2.7 GHz leads to a model for diffuse sources in which there are at least two components of interstellar dust, one at 40 K and one at 165 K, responsible for the 90 micron and 20 micron emission respectively. Both components and the ionized gas must be mixed together; dust in an outer neutral shell is relatively unimportant for these sources. The diffuse sources have small infrared excesses and weak temperature gradients. Unresolved, probably compact, sources were observed at S106 and ON 2 and are briefly discussed.

Campbell, M. F.↗

Arcsecond Positions for Milliarcsecond VLBI Nuclei of Extragalactic Radio Sources, Part 2: 207 Sources

Very long base interferometry measurements of time delay and fringe frequency at 2.29 GHz on baselines of 10,000 km between Deep Space Network stations were used to determine the positions of the milliarcsecond nuclei in 207 extragalactic radio sources. Estimated accuracies generally range from approximately 0.1 to approximately 1.0, in both right ascension and declination, with all sources having uncertainties 4" in both coordinates. The observed sources are part of an all-sky VLBI catalog of milliarcsecond radio sources. Arcsecond positions are now determined for 752 of these sources. Arcsecond positions serve as a useful starting point in the construction of high-precision VLBI reference frames and are also important for unambiguous determination of optical counterparts to compact radio sources.

Morabito, D. D.↗

Discovery of a Hand X-Ray Source, SAX J0635+0533, in the Error Box of the Gamma-Ray Source 2EG J0635+0521

We have discovered an X-ray source, SAX J0635+0533, with a hard spectrum within the error box of the GeV gamma-ray source in Monoceros, 2EG J0635+0521. The unabsorbed flux from the source is 1.2 x 10(exp -11) ergs /sq cm s in the 2-10 keV band. The X-ray spectrum is consistent with a simple power-law model with absorption. The photon index is 1.50 +/- 0.08, and we detect emission out to 40 keV. Optical observations identify a counterpart with a V magnitude of 12.8. The counterpart has broad emission lines and the colors of an early B-type star. If the identification of the X-ray/optical source with the gamma-ray source is correct, then the source would be a gamma-ray-emitting X-ray binary.

Kaaret, P.↗

A source-attractor approach to network detection of radiation sources

Radiation source detection using a network of detectors is an active field of research for homeland security and defense applications. We propose Source-attractor Radiation Detection (SRD) method to aggregate measurements from a network of detectors for radiation source detection. SRD method models a potential radiation source as a magnet -like attractor that pulls in pre-computed virtual points from the detector locations. A detection decision is made if a sufficient level of attraction, quantified by the increase in the clustering of the shifted virtual points, is observed. Compared with traditional methods, SRD has the following advantages: i) it does not require an accurate estimate of the source location from limited and noise-corrupted sensor readings, unlike the localizationbased methods, and ii) its virtual point shifting and clustering calculation involve simple arithmetic operations based on the number of detectors, avoiding the high computational complexity of grid-based likelihood estimation methods. We evaluate its detection performance using canonical datasets from Domestic Nuclear Detection Office s (DNDO) Intelligence Radiation Sensors Systems (IRSS) tests. SRD achieves both lower false alarm rate and false negative rate compared to three existing algorithms for network source detection.

Wu, Qishi↗

Seismic source functions from free-field ground motions recorded on SPE: Implications for source models of small, shallow explosions

In this, reduced displacement potentials (RDPs) for chemical explosions of the Source Physics Experiments (SPE) in granite at the Nevada Nuclear Security Site are estimated from free-field ground motion recordings. Far-field P wave source functions are proportional to the time derivative of RDPs. Frequency domain comparisons between measured source functions and model predictions show that high-frequency amplitudes roll off as ω -2 , but models fail to predict the observed seismic moment, corner frequency, and spectral overshoot. All three features are fit satisfactorily for the SPE-2 test after cavity radius R c is reduced by 12%, elastic radius is reduced by 58%, and peak-to-static pressure ratio on the elastic radius is increased by 100%, all with respect to the Mueller-Murphy model modified with the Denny-Johnson R c scaling law. A large discrepancy is found between the cavity volume inferred from RDPs and the volume estimated from laser scans of the emplacement hole. The measurements imply a scaled R c of ~5 m/kt 1/3 , more than a factor of 2 smaller than nuclear explosions. Less than 25% of the seismic moment can be attributed to cavity formation. A breakdown of the incompressibility assumption due to shear dilatancy of the source medium around the cavity is the likely explanation. New formulas are developed for volume changes due to medium bulking (or compaction). A 0.04% decrease of average density inside the elastic radius accounts for the missing volumetric moment. Assuming incompressibility, established R c scaling laws predicted the moment reasonable well, but it was only fortuitous because dilation of the source medium compensated for the small cavity volume.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

High Intensity Polarized Electron Sources

During the 1990s, at numerous facilities world wide, extensive R and D devoted to constructing reliable GaAs photoguns helped ensure successful accelerator-based nuclear and high-energy physics programs using spin polarized electron beams. Today, polarized electron source technology is considered mature, with most GaAs photoguns meeting accelerator and experiment beam specifications in a relatively trouble-free manner. Proposals for new collider facilities however, require electron beams with parameters beyond today's state-of-the-art and serve to renew interest in conducting polarized electron source R and D. And at CEBAF/Jefferson Lab, there is an immediate pressing need to prepare for new experiments that require considerably more beam current than before. One experiment in particular - Q-weak, a parity violation experiment that will look for physics beyond the Standard Model--requires 180 uA average current at polarization >80% for a duration of one year, with run-averaged helicity correlated current asymmetry less than 0.1 ppm. Neighboring halls will continue taking beam during Q-weak, pushing the total average beam current from the gun beyond 300 uA. This workshop contribution describes R and D at Jefferson Lab, dedicated toward extending the operating current of polarized electron sources to meet the requirements of high current experiments at CEBAF and to better appreciate the technological challenges of new accelerators, particularly high average current machines like eRHIC that require at least 25 mA at high polarization.

43 PARTICLE ACCELERATORS↗

Control system for the Spallation Neutron Source H{sup -} source test facility Allison scanner

Spallation Neutron Source is currently in progress of a multiyear plan to ramp ion beam power to the initial design power of 1.4 MW. Key to reaching this goal is understanding and improving the operation of the H{sup -} ion source. An Allison scanner was installed on the ion source in the test facility to support this improvement. This paper will discuss the hardware and the software control system of the installed Allison scanner. The hardware for the system consists of several parts. The heart of the system is the scanner head, complete with associated bias plates, slits, and signal detector. There are two analog controlled high voltage power supplies to bias the plates in the head, and a motor with associated controller to position the head in the beam. A multifunction data acquisition card reads the signals from the signal detector, as well as supplies the analog voltage control for the power supplies. To synchronize data acquisition with the source, the same timing signal that is used to trigger the source itself is used to trigger data acquisition. Finally, there is an industrial personal computer to control the rest of the hardware. Control software was developed using National Instruments LABVIEW, and consists of two parts: a data acquisition program to control the hardware and a stand alone application for offline user data analysis.

43 PARTICLE ACCELERATORS↗