Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Optical boundary reconstruction of tokamak plasmas for feedback control of plasma position and shape

A new diagnostic is developed to reconstruct the plasma boundary using visible wavelength images. Exploiting the plasma's edge localized and toroidally symmetric emission profile, a new coordinate transform is presented to reconstruct the plasma boundary from a poloidal view image. The plasma boundary reconstruction is implemented in MATLAB and applied to camera images of Mega-Ampere Spherical Tokamak discharges. The optically reconstructed plasma boundaries are compared to magnetic reconstructions from the offline reconstruction code EFIT, showing very good qualitative and quantitative agreement. Average errors are within 2 cm and correlation is high. In the current software implementation, plasma boundary reconstruction from a single image takes 3 ms. The applicability and system requirements of the new optical boundary reconstruction, called OFIT, for use in both feedback control of plasma position and shape and in offline reconstruction tools are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VERIFICATION MEASUREMENTS OF THE MASS AND ENRICHMENT OF URANIUM OXIDE CARD SOURCES

Measurements were performed to determine the mass and enrichment of 10 uranium oxide (U3O8) card sources. The measurements and analysis were completed as a verification of the card sources in support of Oak Ridge National Laboratory’s nuclear material control and accountability program. Although these cards are not nationally accredited as a nuclear standard, they are used as a working reference for measurements, such as holdup. The uranium card source measurements were taken with a broad energy germanium detector and the Genie 2000 Gamma Acquisition and Analysis software. A complete characterization of each of the 10 uranium card sources was performed using the 4 characteristic full energy peaks of 235U. Using the In Situ Object Counting System software to determine the mathematical efficiency of the measurement, the mass of 235U in each card was determined. The 235U mass in each card ranged from 10.42 to 12.63 g with a systematic error between 0.76 and 0.95 g and a random error of 0.01 g for each card source. The Multi-Group Analysis for Uranium (MGAU) software and the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) isotopic analysis software were used to determine the isotopic composition of the uranium cards. The measured enrichment was compared to the declared enrichment for each card, with uncertainties ranging from 2.7% to 4.3% for the MGAU analysis and 2.3% to 4.1% for the FRAM analysis. This is a good example of how a well-benchmarked mathematical calibration method can be useful in characterizing uranium sources.

Hunneke, Rachel↗

Active learning emulators for nuclear two-body scattering in momentum space

In this work we extend the active learning emulators for two-body scattering in coordinate space with error estimation, recently developed by Maldonado et al. [Phys. Rev. C 112, 024002], to coupled-channel scattering in momentum space. Our full-order model (FOM) solver is based on the Lippmann-Schwinger integral equation for the scattering t-matrix as opposed to the radial Schrödinger equation. We use (Petrov-)Galerkin projections and high-fidelity calculations at a few snapshots across the parameter space of the interaction to construct efficient reduced-order models (ROMs), trained by a greedy algorithm for locally optimal snapshot selection. Both the FOM solver and the corresponding ROMs are implemented efficiently in Python using Google's JAX library. We present results for emulating scattering phase shifts in coupled and uncoupled channels and cross sections, and assess the accuracy of the developed ROMs and their computational speedup factors. We also develop emulator error estimation for both the t-matrix and the total cross section. The software framework for reproducing and extending our results is publicly available. Together with our recent advances in developing active-learning emulators for three-body scattering, these emulator frameworks set the stage for full Bayesian calibrations of chiral nuclear interactions and optical models against scattering data with quantified emulator errors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

KT3D GUI

The KT3D GUI provides a graphic user interface to a public domain FORTRAN code (kt3d) that was developed at Stanford University in 1998 (see Deutsch and Journel, 1998). The kt3d software contains the implementation of several kriging algorithms that complete spatial estimation onto a grid or a set of points from a set of available data and using a variogram model to describe the spatial variation of the data. The variogram model is calculated and modeled using the GAM/GAMV GUI software described separately. The KT3D GUI software allows the user to set various parameters for the FORTRAN code by using dialog boxes, it provides some error checking as these parameters are set and then allows the user to run the calculation by calling the executable compiled from the previously developed FORTRAN software. The resulting output of the kt3d code can be visualized in the KT3D GUI in several ways. If a gridded estimation problem is selected, color maps of the estimated values and the kriging variance are displayed in side by side images. If either jackknifing or cross-validation options are selected, then a series of user-defined X-Y plots can be created.

McKenna, Sean↗

Theoretical investigation of resonant frequencies of unstrapped magnetron with arbitrary side resonators

In this paper, a sector steps approximation method is proposed to investigate the resonant frequencies of magnetrons with arbitrary side resonators. The arbitrary side resonator is substituted with a series of sector steps, in which the spatial harmonics of electromagnetic field are also considered. By using the method of admittance matching between adjacent steps, as well as field continuity conditions between side resonators and interaction regions, the dispersion equation of magnetron with arbitrary side resonators is derived. Resonant frequencies of magnetrons with five common kinds of side resonators are calculated with sector steps approximation method and computer simulation softwares, in which the results have a good agreement. The relative error is less than 2%, which verifies the validity of sector steps approximation method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Effects of Charge Transfer Inefficiency (CTI) on Galaxy Shape Measurements

(Abridged) We examine the effects of charge transfer inefficiency (CTI) during CCD readout on galaxy shape measurements required by studies of weak gravitational lensing. We simulate a CCD readout with CTI such as that caused by charged particle radiation damage. We verify our simulations on data from laboratory-irradiated CCDs. Only charge traps with time constants of the same order as the time between row transfers during readout affect galaxy shape measurements. We characterize the effects of CTI on various galaxy populations. We baseline our study around p-channel CCDs that have been shown to have charge transfer efficiency up to an order of magnitude better than several models of n-channel CCDs designed for space applications. We predict that for galaxies furthest from the readout registers, bias in the measurement of galaxy shapes, Delta(e), will increase at a rate of 2.65 +/- 0.02 x 10^(-4) per year at L2 for accumulated radiation exposure averaged over the solar cycle. If uncorrected, this will consume the entire shape measurement error budget of a dark energy mission within about 4 years. Software mitigation techniques demonstrated elsewhere can reduce this by a factor of ~10, bringing the effect well below mission requirements. CCDs with higher CTI than the ones we studeied may not meet the requirements of future dark energy missions. We discuss ways in which hardware could be designed to further minimize the impact of CTI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cooperative Application/OS DRAM Fault Recovery

Exascale systems will present considerable fault-tolerance challenges to applications and system software. These systems are expected to suffer several hard and soft errors per day. Unfortunately, many fault-tolerance methods in use, such as rollback recovery, are unsuitable for many expected errors, for example DRAM failures. As a result, applications will need to address these resilience challenges to more effectively utilize future systems. In this paper, we describe work on a cross-layer application/OS framework to handle uncorrected memory errors. We illustrate the use of this framework through its integration with a new fault-tolerant iterative solver within the Trilinos library, and present initial convergence results.

99 GENERAL AND MISCELLANEOUS↗

diffReplication - An Energy-Aware Fault Tolerance Model for Silent Error Detection and Mitigation in Heterogeneous Extreme-scale Computing Environment

At extreme scale, the frequency of silent errors – a class of errors that remain undetected by low-level error detection mechanisms – increases significantly with the computational complexity of the application and the scale of the computing infrastructure. As hardware and software advances are made to usher in the next scientific era of computing, developing new approaches to mitigate the impact of silent errors remains a challenging problem. In this work, we propose an energy-aware fault-tolerance model, referred to diffReplication to overcome silent errors. In the proposed model, the main process is associated with one replica that executes at the same rate as the main process, and one diffReplica that is executed at a fraction of the main process' execution rate. If the main and its replica reach consensus at the end of a computation phase, the state of the diffReplica is updated and computation is resumed. If the synchronization attempt results in a disagreement, however, the diffReplica increases its execution speed to complete the computation and quickly reach the synchronization barrier. Assuming a single error over any given synchronization interval, a majority voting is used to reach consensus and tolerate silent errors. To further enhance its performance, diffReplication is augmented with speculative execution, whereby the main or its fast replica is selected to continue execution without waiting for the diffReplica. The selection process is based on the previous behaviour of the main and its replica. A performance analysis study is carried out to assess the performance of diffReplication, in terms of the energy saving and time-to-completion reduction achieved by the diffReplication scheme. The experiment shows that speculative execution reduces the time to completion with additional energy, and dynamic decision-making balances the energy consumption and time to completion.

97 MATHEMATICS AND COMPUTING↗

Simultaneous {sup 233}U and{sup 235}U characterization through the assay of delayed neutron temporal behavior

Aqueous solutions containing dissolved uranium-233 and uranium-235 were irradiated for 60's in the SLOWPOKE-2 reactor at the Royal Military College of Canada. The temporal behavior of the delayed neutrons produced was recorded by the Facility's Delayed Neutron Counting (DNC) system. The percentage of uranium-233 as a function of total fissile mass present in each sample ranged from 0 to 100% and was predicted by the DNC system with average absolute errors of {+-} 4%. Future work will upgrade the system electronics and software to reduce both uncertainties in timings and electrical noise. Mixture analysis will also be expanded to include plutonium-239 and fissile materials contained in non-aqueous matrices. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-BRF-04: Evaluation of Five Commercially-Available Algorithms for Deformable Image Registration

Purpose: Deformable image registration (DIR) is increasingly being used in various clinical applications. Although there are several DIR packages all making successful attempts at modeling complex anatomical changes using even more complex mathematical approximations, they are all subject to various uncertainties. Many studies have attempted to quantify the spatial uncertainty with DIR. This is the first study to compare the uncertainty for interfraction DIR for 5 different commercially-available algorithms. The aim of this study was to benchmark the performance of the most commonlyused DIR algorithms offered through these 5 software packages: Eclipse, MIM, Pinnacle, RaySearch, and Velocity. Methods: A set of 10 virtual H'N phantoms [Pukala et al. MedPhys. 40(11) 2013] with known deformations were used to determine the spatial errors that might be seen when performing DIR. The “ground-truth” deformation vector field (DVF) was compared to the DVF output of the 5 commercially-available algorithms in order to evaluate spatial errors for six regions of interest (ROIs): brainstem, cord, mandible, left parotid, right parotid, and the external body contour. Results: We found that each software package had varying uncertainties with the various ROIs, but were generally all comparable to one another – with mean spatial errors for each algorithm below 3.5 mm for each ROI (averaged across all phantoms). We also found that no single algorithm was the clear winner over the other 4 algorithms. However, at times, we found huge maximum errors in our results (e.g. phantom #9 maximum errors: right parotid = 22.9 mm, external contour = 30.5mm) with the varying DIR algorithms. Conclusion: Although our evaluation was limited to H'N patients, we show that our methods are a single-assessment analysis tool that could be used by any physicist, within any type of facility, to compare their DIR software before initiating widespread use within their daily radiotherapy practice.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-02: Auto Weekly - An Automated Online Weekly Chart Check System for Medical Physics

Purpose: Radiation therapy has evolved to become not only more precise and potent, but also more complicated to monitor and deliver. More rigorous and comprehensive quality assurance is needed to safeguard ever advancing radiation therapy. ICRU standards dictate that an ever growing set of treatment parameters are manually checked weekly by medical physicists. This “weekly chart check” procedure is laborious and subject to human errors or other factors. A computer-assisted chart checking process will enable more complete and accurate human review of critical parameters, reduce the risk of medical errors, and improve the efficiency. Methods: We developed a web-based software system that enables a thorough weekly quality assurance checks. In the backend, the software retrieves all machine parameters from a Treatment Management System (TMS) and compares them against the corresponding ones from the treatment planning system. They are also checked for validity against preset rules. The results are displayed as a web page in the front-end for physicists to review. Then a summary report is generated and uploaded automatically to the TMS as a record for weekly chart checking. Results: The software system has been deployed on a web server in our department’s intranet, and has been tested thoroughly by our clinical physicists. A plan parameter would be highlighted when it is off the preset limit. The developed system has changed the way of checking charts with significantly improved accuracy, efficiency, and completeness. It has been shown to be robust, fast, and easy to use. Conclusion: A computer-assisted system has been developed for efficient, accurate, and comprehensive weekly chart checking. The system has been extensively validated and is being implemented for routine clinical use.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-00: Deformable Image Registration: Is It Right for Your Clinic

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-01: Overview of DIR Advantages/Challenges and Workflow

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-02: DIR QA Options and Research Development

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-03: Overview of Proposed TG-132 Recommendations

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

Algorithm and program for precise determination of unit-cell parameters of single crystal taking into account the sample eccentricity

A technique has been developed to refine the unit-cell parameters of single crystals with minimization of the influence of instrumental errors on the result. The corresponding computational procedure HuberUB is added to the software package of Huber-5042 diffractometer with a point detector and closedcycle helium cryostat Displex DE-202. The parameters of unit cell, its orientation, the goniometer zero angles, the sample eccentricity, the distances in the goniometer, and the radiation wavelength were refined by the nonlinear least-squares method, which allows imposition of constraints on the unit-cell parameters, depending on the crystal symmetry. The technique is approved on a LuB{sub 12} single crystal. The unit-cell parameters are determined in a temperature range of 20–295 K, with an absolute error not larger than 0.0004 Å (the relative error is of ~5 × 10{sup –5}). The estimates of the unit-cell parameters obtained by the proposed method are evidenced to be unbiased. Some specific features of the behavior of parameters in the ranges of 120–140 and 20–50 K are revealed, which correlate with the anomalies of the physical properties of the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance study of atomic tally methods for GPU-accelerated Monte Carlo dose calculation - 25352

Over the past several years, the graphics processing unit (GPU) technology has rapidly gained ground in scientific computing due to its outstanding performance and programmability. GPU implementation of Monte Carlo radiation transport for dose calculations has been reported by many investigators. The majority of these studies adopted single-precision floating point format because of the higher peak floating point operations per second (FLOPS) the GPUs can deliver than double-precision. It has been known that calculation using single-precision is more prone to numerical round-off errors, especially when a single tally data is accumulated 'atomically' and repeatedly by thousands of GPU threads. To mitigate this problem, the least intrusive solution in theory is to replace the single-precision atomic-add tally function with a double-precision version. However, the complexity lies in the fact that some GPUs (Nvidia GPUs prior to the Pascal generation; all current AMD GPUs) do not readily offer such double-precision function at hardware level, and that software emulation is too slow to use if not optimized properly. This paper discusses several atomic-add tally methods with reduced numerical errors used throughout ARCHER development. The original software-based compare-and-swap method (CAS) was shown to be inefficient due to high intra-warp thread contention, whereas the improved software-based warp-aggregated method (WAG) and Kahan summation method (KAS) eliminated the thread contention and performed very well on Kepler and Maxwell GPUs, being more than 13 times faster than CAS in our tests. The hardware-based (HB) double-precision atomic-add feature available on Pascal and Volta GPUs exceeded software emulation and offered the best performance universally, so did WIB, a combination of WAG and HB methods. It was also shown that in a single-precision dose engine, KAS managed to maintain high reliability when the single-precision atomic-add tally underestimated the dose by 25%. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗