Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ScO2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Approaches for Water Removal in Direct-Fired sCO 2 Power Cycles

There is interest in investigation of water removal processes in direct fired sCO 2 flows, as this may potentially lead to greater system efficiency as the removal of this contaminant will result in sCO 2 behaving close to idealized behaviors. Water removal should be split into a two-step process, condensation of the water, followed by separation of the liquid phase water from the sCO 2 . The two main avenues of condensation are manipulation of pressure and temperature for phase change. For this paper, temperature-based phase change is the primary focus through the implementation of heat exchangers. Of the heat exchangers investigated it was found that printed circuit heat exchangers (PCHEs) could be an alternative for this use case, though the specific design of flow channel geometry and flow direction depends on the specific system case and cannot be determined at this point. For water separation there were four processes identified, all of which already assume water is in liquid phase at that point in the system. Of these separation avenues the best candidate is the hydrocyclone as it has a proven history of separating liquid-liquid phase mixtures with small density differences in oilfield use, in addition they have been investigated and modeled specifically for water separation for sCO 2 flows and the footprint is relatively small.

20 FOSSIL-FUELED POWER PLANTS↗

Adiabatic Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for an adiabatic cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Direct Dry Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Gen3 Gas Phase System Development and Demonstration (Final Technical Report)

Work undertaken in this project seeks to transform the current baseline technology – which is a collection of related but separately developed components and concepts – into a unified and operating test facility and an accompanying preliminary commercial design. This project is motivated by the primary goal of developing a system to absorb concentrated solar energy and deliver it into thermal energy storage at temperatures above 700°C, thereby enabling integration with a high-efficiency supercritical carbon dioxide (sCO 2 ) power cycle to achieve or exceed a levelized cost of electricity (LCOE) target of 6 ¢ per kilowatt-hour electric (kW e -hr). The proposed baseline solution utilizes a high-temperature gas phase (GP) system interfacing with a two-tank particle thermal energy storage (TES) and intermediate heat exchangers to supply sCO 2 at 20-25 megapascals (MPa) and 700°C at the turbine inlet.

14 SOLAR ENERGY↗

High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines (Final Report)

This is the final report for project DE-FE0031924 titled “High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines.” The report provides a summary of the entire project efforts from October 2020 through December 2024 including the high-temperature commercial dry gas seal (DGS) tests and thermal modeling of Task 2, as well as the high-temperature, large-diameter seal design and high-temperature tests of large-diameter seals in Task 3. A key outcome of Task 2 was the testing completion of specially instrumented commercial DGS in the GE-SwRI Apollo sCO 2 compressor (27,000 rpm). Test data from the DGS showed elevated temperatures upwards of 350 o F, which are close to the higher operating temperature limit of the DGS. The temperature measurements provide insight into the expected thermal loads on DGS operating in high-speed sCO 2 compressor and provided test data for validation of an in-house thermal model of the compressor/seal. Under Task 2.0, this report also presents the development of a steady-state conjugate heat-transfer model of the DGS operating in the sCO 2 compressor – a first of its kind model for modeling heat transfer of sCO 2 in an actual operating compressor. The findings of the thermal model show a reasonable match between temperature predictions of the model and the measured temperature data, also pointing out the validity of the approach and assumptions made in modeling the flows, heat transfer coefficients and windage modeling in the rig. Under Task 3.0, this report presents the preliminary design of a large-diameter hybrid face seal (14 inch and 26-inch diameter) for field testing in a land-based GE turbine. The preliminary seal design effort presented in this report under project DE-FE0031924 builds on the development and successful laboratory testing for such large diameter hybrid face seal under the prior DE-FE0024007 project. Key aspects of seal fluid analyses with CFD, mechanical design considerations and assembly considerations in a land-based turbine are presented. Finally, under Task 3.0, this report also presents the continued high-temperature testing of the 14-inch diameter hybrid face seal developed previously under the DE-FE0024007 program. Specifically, test data demonstrating successful non-contact seal operation and seal effective leakage of 0.001-inch with seal inlet temperatures above 700 o F are presented in this report. Successful hybrid seal operation in a laboratory environment for a large diameter (14-inch) seal at temperatures above 700 o F is a major technological milestone for this technology.

01 COAL, LIGNITE, AND PEAT↗

Thermal hydraulic characteristics of liquid sodium and supercritical CO 2 in a diffusion bonded heat exchanger

Compact heat exchangers are being examined for use in advanced, high-temperature nuclear or concentrated solar power plants to improve thermal efficiencies and reduce capital costs. At the time of this work, no experimental investigation of liquid sodium in the popular diffusion-bonded heat exchanger design had been performed. Herein this paper describes the thermal-hydraulic and overall operations performance observed during testing of a 316/L stainless steel “zig-zag” microchannel heat exchanger operating between a (0.5 kg/s) sodium loop and a (0.3 kg/s) recuperated supercritical CO 2 system with outlet conditions up to 550 °C at 16 MPa. Observed pressure drop is presented in the form of an effective friction factor correlation which aligns closely with recent experimental data. The thermal performance of this heat exchanger, measured by its overall conductance under various flow conditions, was decomposed to examine the independent convection behaviors of both the CO 2 and sodium streams. These results are presented in the form of Nusselt correlations fitted to the experimental data. The sodium heat transfer correlation aligns closely with the widely accepted Lubarsky-Kaufman correlation, while the CO 2 heat transfer correlation lies between previous correlations developed by computational and experimental methods. This was the first long-duration use of sodium in a microchannels (~1.8 mm hydraulic diameter) heat exchanger. The use of an oxide control system enabled trouble-free operation of the heat exchanger for over 150 h of high-temperature operation. This first-of-a-kind demonstration using liquid sodium and supercritical carbon dioxide shows great promise for further application of this technology in advanced nuclear or solar power plants.

42 ENGINEERING↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Physics-Informed Deep Learning-Based Proof-of-Concept Study of a Novel Elastohydrodynamic Seal for Supercritical CO 2 Turbomachinery

Supercritical carbon dioxide (sCO 2 ) power cycles show promising potential of higher plant efficiencies and power densities for a wide range of power generation applications such as fossil fuel power plants, nuclear power production, solar power, and geothermal power generation. sCO 2 leakage through the turbomachinery has been one of the main concerns in such applications. To offer a potential solution, we propose an elastohydrodynamic (EHD) seal that can work at elevated pressures and temperatures with low leakage and minimal wear. The EHD seal has a very simple, sleeve-like structure, wrapping on the rotor with minimal initial clearance at micron levels. Here, in this work, a proof-of-concept study for the proposed EHD seal was presented by using the simplified Reynolds equation and Lame’s formula for the fluid flow in the clearance and for seal deformation, respectively. The set of nonlinear equations was solved by using both the conventional Prediction–Correction (PC) method and modern Physics-Informed Neural Network (PINN). It was shown that the physics-informed deep learning method provided good computational efficiency in resolving the steep pressure gradient in the clearance with good accuracy. The results showed that the leakage rates increased quadratically with working pressures and reached a steady-state at high-pressure values of 15~20 MPa, where Q = 300 g/s at 20 MPa for an initial seal clearance of 255 μm. This indicates that the EHD seal could be tailored to become a potential solution to minimize the sCO 2 discharge in power plants.

30 DIRECT ENERGY CONVERSION↗

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Closed Loop Geothermal Working Group: GeoCLUSTER App, Subsurface Simulation Results, and Publications

To better understand the heat production, electricity generation performance, and economic viability of closed-loop geothermal systems in hot-dry rock, the Closed-Loop Geothermal Working Group -- a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed-loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and supercritical CO2) while varying seven continuous independent parameters of interest (mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying Python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the techno-economic analysis script are provided. This data submission will contain results from the Closed Loop Geothermal Working Group study that are within the public domain, including publications, simulation results, databases, and computer codes. GeoCLUSTER is a Python-based web application created using Dash, an open-source framework built on top of Flask that streamlines the building of data dashboards. GeoCLUSTER provides users with a collection of interactive methods for streamlining the exploration and visualization of an HDF5 dataset. The GeoCluster app and database are contained in the compressed file geocluster_vx.zip, where the "x" refers to the version number. For example, geocluster_v1.zip is Version 1 of the app. This zip file also contains installation instructions. **To use the GeoCLUSTER app in the cloud, click the link to "GeoCLUSTER on AWS" in the Resources section below. To use the GeoCLUSTER app locally, download the geocluster_vx.zip to your computer and uncompress this file. When uncompressed this file comprises two directories and the geocluster_installation.pdf file. The geo-data app contains the HDF5 database in condensed format, and the GeoCLUSTER directory contains the GeoCLUSTER app in the subdirectory dash_app, as app.py. The geocluster_installation.pdf file provides instructions on installing Python, the needed Python modules, and then executing the app.

15 GEOTHERMAL ENERGY↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Ultra High-Temperature Magnetic Bearing System for s-CO 2 Turbines/Expanders. Phase II Final Report

The goal of this project is to design and construct of a prototype of ultra-high temperature permanent magnet (UHT–PM), which provides the force to pull the spinning shaft towards the target position in the magnetic bearing (MB) clearance circle. This project will develop a PM biased MB system, that is actively cooled to the 550°C maximum operating temperature limit of PMs. The MB test environment will include 700°C, 40krpm and 4,000 psi requirements to advance the supercritical carbon dioxide (sCO 2 ) and other types of Brayton power cycle systems. The proposed novel MBs combine PMs for supplying the bias field and electromagnets for supplying the control field, both in UHT conditions. The choice of material is the UHT Sm-Co PMs (US patent 6,451,132) due to their significantly better thermal stability. The 6-pole homopolar design permits uninterrupted force delivery via a redundant control capability (US patent 7,429,811) even if 3 poles were to fail. The Phase I efforts was to focus on development and demonstration of component technologies and detailed design of full scale components and a demonstrator test rig for use in Phase II. UHT–PMs were produced and used in the MB actuator. The operating environment of the EEC-T550 Sm-Co magnet material could be extended by implementing active cooling. Electromagnetic coils imbedded in the MB provide forces to stabilize the shaft position at the target via sensing and control stages. Shaft position sensors enable to identify the present position of the spinning shaft relative to its desired target position in the MB clearance circle (air gap). Auxiliary bearings will be installed to provide a backup support system in the event that power to the MB fails or there is a fault in a device providing current to the MB coils. For control, reliability and safety reasons the sensors and auxiliary bearings are typically located as close as possible to the MBs, which exposes them to the same environmental conditions. Development of only the actuator for the UHT environment is an inadequate approach to complete integration of the MB system in the turbine/expander. Therefore the UHT sensor and auxiliary bearing were designed and developed along with the actively cooled, UHT-PM actuator development. Although shaft position sensors are commercially available (Kaman) they may cost up to $10k per channel, and a full 5 axis magnetic suspension is best implemented with up to 20 sensors. Once successfully completed, this project will significantly extend the operating environment capability for turbomachinery applications such as nuclear power, concentrated solar thermal, fossil fuel, geothermal, and shipboard propulsion. The further advancement of UHT-PM-MB will also strengthen the US position in PM technology, which is presently heavily dominated by China. The UHT Sm-Co magnet material that will be utilized in the proposed work has been developed exclusively by the project proposer. Many actuators, motors, generators and other MB applications will greatly benefit from the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovative Method for Welding in Generation 3 CSP to Enable Reliable Manufacturing of Solar Receivers to withstand Daily Cycling at Temperatures Above 700°C (Final Technical Report)

Inconel® Alloy 740H® (alloy 740H) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. Over the past ~20 years the alloy has been optimized for weldability and high-temperature stability, approved for use in different applications. Development of a supply chain combined with the advantageous properties of the alloy (high-temperature creep strength, oxidation and corrosion resistance, etc.) have resulted in the alloy being applied to new high-temperature power cycle demonstration projects, and of particular interest are applications to concentrating solar power (CSP) to enable higher-efficiency Generation 3 CSP systems and the corresponding supercritical CO 2 (sCO 2 ) power cycle components (heat exchangers, piping, etc.). The high allowable stresses of alloy 740H also make it a desirable material for current Generation 2 CSP solar power receivers to improve cyclic capability and/or reduce receiver height. Recent experiences in demonstration projects utilizing alloy 740H identified cracking issues during welding and fabrication. In this project, a detailed study was done to confirm and clarify the Stress Relaxation Cracking (SRxC) mechanism, also known as stress relief cracking or strain-age cracking (SAC), during post-weld heat-treatment (PWHT). This involved detailed microscopy and advanced characterization to understand the root cause(s) of three failures obtained from industry. Based in-part on these findings, a targeted laboratory based SRxC test method was utilized to evaluate variables such as heat-to-heat variations, strain level, PWHT temperature, and starting material condition on three heats of alloy 740H. Industrial shop welding of cold-worked plates was also conducted. The research showed the following: SRxC was confirmed as the cracking mechanism for all field failures; Stress state (from residual stresses, constraint, deformation, and local stress concentrations) was playing a significant role in field failures and laboratory testing confirmed increasing susceptibility for all heats with increasing strain levels. High levels of microstructural strain were identified at crack initiation locations, in some cases leading to local recrystallization; Precipitate free zones (PFZs) at grain boundaries were found at relaxation cracks and crack initiation locations uniquely associated with SRxC in alloy 740H. Laboratory testing reproduced this microstructural feature which had only previously been reported in long-term creep testing of weldments. Advanced nano-scale characterization confirmed the presence of a moving boundary leading to coarsening of precipitates and PFZs where damage accumulated; The research suggested heat-to-heat variations due to local chemistry and processing may influence SRxC susceptibility, but more work is needed to fully clarify these effects. To disseminate the key learnings from this research to the scientific and engineering communities and alloy 740H end users, multiple technical publications and presentations were made, an industrial alloy 740H users meeting was held, and a new industry guideline specification document which can be directly implemented by end-users of alloy 740H was produced.

14 SOLAR ENERGY↗

High Inlet Temperature Combustor for Direct-Fired Supercritical Oxy-Combustion

It is envisioned that supercritical CO 2 (sCO 2 ) electric power plant efficiencies can exceed 52% with 99% carbon capture using direct-fired oxy-combustion. Such efficiencies would be competitive with Natural Gas Combined Cycles (NGCC) and operate with nearly zero carbon emissions. To achieve high plant efficiencies, turbine inlet conditions must approach 1,200 °C at 250 bar. Such conditions, while desirable from a systems perspective, exceed the current state of the art in turbine design and materials qualification. The team of Southwest Research Institute ® (SwRI ® ), Georgia Institute of Technology (Georgia Tech), Spectral Energies, LLC (Spectral), GE Global Research (GE-GRC), and the University of Central Florida (UCF) sought to demonstrate an intermediate step toward these high efficiency plants with the development of a 1 MWth, subscale direct-fired oxy-fuel combustor. The efforts focused largely on the development of an auto-ignition based combustion system capable of providing the targeted 1200 °C and the pilot-scale plant to operate the combustor. While the project was stopped short of the commissioning and demonstration work, the advances made in this effort will reduce risks associated with chemical kinetics, thermal management, water separation, flue gas cleanup, materials selection, and corrosion in future demonstration efforts for the direct-fired oxy-fuel combustion cycles. The following report documents the design, analysis, and installation efforts completed during the project periods of performance.

03 NATURAL GAS↗

Low‐cost, Long Duration Electrical Energy Storage Using a CO 2 ‐based Pumped Thermal Energy Storage

The increasing deployment of non‐dispatchable, intermittent renewable energy generation sources to address climate change is placing pressure upon electrical grids’ ability to match supply with demand. The need to deploy large quantities of long duration energy storage assets is rapidly approaching, and innovative methods of energy storage that are low cost, efficient, safe and environmentally benign are needed urgently. CO 2 ‐based Pumped Thermal Energy Storage (PTES) is a low cost, efficient and environmentally safe energy storage technology. PTES uses an electrically‐driven CO 2 heat pump to charge thermal reservoirs that are later used as resources to generate electricity using a CO 2 heat engine. In this program, Echogen and collaborators refined the design of a utility‐scale CO 2 PTES system and demonstrated key technologies that will be required for successful commercial development in a laboratory‐scale system. Component and system‐level performance was evaluated over multiple charge/discharge cycles, with favorable results. Echogen is continuing to develop and commercialize this technology at utility scale.

25 ENERGY STORAGE↗