Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a network hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAR regulation technologies as an example to illustrate system setups, communication requirements among different HIL test systems, and connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

digital twin, distribution system, co-simulation, ↗

Analysis of Multi-Output Hybrid Energy Systems Interacting with the Grid: Application of Improved Price-Taker and Price-Maker Approaches to Nuclear-Hydrogen Systems

The growing recognition of the value of hydrogen as an energy intermediate in supporting future power systems with high shares of variable renewable energy has prompted many studies to quantify the economic potential of multi-output hybrid systems, which are one type of integrated energy systems (IES). Because of the complexity of modeling multiple sectors, these studies typically use simplified modeling approaches to capture the interactions between sectors. In this study, we explore the implications of alternative modeling approaches for nuclear-hydrogen IES focusing on a power system in the Midwest United States. We combine highly resolved capacity expansion and production cost modeling tools of the power system with a detailed hydrogen system optimization tool to determine the optimal electrolyzer and storage sizing and optimal operations of the nuclear-hydrogen hybrid resource across three future study years. We compare economic and operational outcomes across a spectrum of modeling approaches, including a non-hybridized base approach; a traditional price-taker approach that does not include the impact of hydrogen production on the electricity system; a power-system-focused price-maker approach that does not account for temporal hydrogen constraints; and two improved price-taker and price-maker approaches that each address the impact of revenue-optimal levels of electricity production on the resulting power system and temporal hydrogen constraints on the overall feasible solution. Results show how a traditional price-taker approach can overestimate the economic benefits of multi-output nuclear-hydrogen IES compared to our two improved approaches that estimate both hydrogen system constraints and power system interaction. We find that hydrogen output requirements and storage size limits are key drivers to overall operations and some economic outcomes. Under our assumed constant hydrogen output requirement, storage costs, test system, and modeling approaches, our results indicate that hybridization can provide a net benefit, but results are sensitive to the treatment of hydrogen revenues and electricity prices as impacted by the power system evolution.

capacity expansion modeling↗

Performance evaluation of radiant cooling system integrated with air system under different operational strategies

The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Integrated Daylighting and Electric Lighting Systems: Current State of the Art and Needed Research

This paper presents the results of a multi-disciplinary scoping study, the goals of which were to see the seamless integration and application of light in buildings, regardless of source, that is purposely modulated to illuminate surfaces and designed in a way that is comfortable, healthy, pleasing, cost effective, and energy efficient. The scoping study was performed in order to set the stage for transforming the design and realization of lighting systems integration (daylight and electric). This, in turn, will support achieving the the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO) long-term energy savings goals. Holistic lighting systems of the future should include components that are adaptable to change, resilient to disruption, and robust. The system of codes, standards, guidelines, and contracts employed to design and implement lighting systems should be structured to help them to flourish, rather than being barriers to realization. Finally, the research thrusts and mechanisms should be engaged with these goals in mind. While integrated lighting systems may reduce lighting energy use in buildings, a broader web of non-energy impacts affecting occupant’s overall health, comfort, and satisfaction may also guide technology investment goals when the entire lighting systems lifecycle is considered. Daylighting systems are separated from electric lighting systems, and both are characteristically detached from other systems such as safety, security, communications, and information systems. Being disconnected from the inputs and outputs of other building systems precludes the ability to acquire and utilize information about occupation, status of systems, and interior and exterior environmental conditions. The outcome of this separation is that the standard building is not fulfilling the potential for creating dynamic and holistic lighting for building occupants.

Davis, Robert G.↗

Resilience assessment and planning in power distribution systems: Past and future considerations

High impact low probability (HILP) events such as hurricanes, heat waves, and floods have instigated widespread power outages and blackouts around the globe in the past decade. With the increasing challenges concerning the threats to the power distribution systems and the growing need to mitigate the impacts of the HILP events, resilience has become a crucial requirement for the power grid infrastructures. Numerous efforts have been made to define, measure, and characterize the resilience of power distribution systems. This study thoroughly reviews the state-of-the-art methods on the existing resilience evaluation framework and metrics. Here, the desirable characteristics of resilience metrics are highlighted, and the challenges associated with formulating, developing, and calculating such metrics are discussed. Next, we detail the state-of-the-art literature on planning solutions to ensure distribution system resilience. This paper aims to extract a deep insight into this challenging and critical research area and envision future opportunities that can guide the power distribution system operators/planners to formulate more effective mitigation strategies to enhance the resilience of power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architecture of Kepler's multi-transiting systems. II. New investigations with twice as many candidates

We report on the orbital architectures of Kepler systems having multiple-planet candidates identified in the analysis of data from the first six quarters of Kepler data and reported by Batalha et al. (2013). These data show 899 transiting planet candidates in 365 multiple-planet systems and provide a powerful means to study the statistical properties of planetary systems. Using a generic mass-radius relationship, we find that only two pairs of planets in these candidate systems (out of 761 pairs total) appear to be on Hill-unstable orbits, indicating ∼96% of the candidate planetary systems are correctly interpreted as true systems. We find that planet pairs show little statistical preference to be near mean-motion resonances. We identify an asymmetry in the distribution of period ratios near first-order resonances (e.g., 2:1, 3:2), with an excess of planet pairs lying wide of resonance and relatively few lying narrow of resonance. Finally, based upon the transit duration ratios of adjacent planets in each system, we find that the interior planet tends to have a smaller transit impact parameter than the exterior planet does. This finding suggests that the mode of the mutual inclinations of planetary orbital planes is in the range 1.°0-2.°2, for the packed systems of small planets probed by these observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Method to study complex systems of mesons in lattice QCD

Correlation functions involving many hadrons allow finite density systems to be explored with Lattice QCD. Recently, systems with up to 12 $\pi^+$'s or $K^+$'s have been studied to determine the the $3$-$\pi^+$ and $3$-$K^+$ interactions and the corresponding chemical potential has been determined as a function of density in each case. We derive recursion relations between correlation functions that allow us to extend this work to systems of arbitrary numbers of mesons and to systems containing arbitrary different types of mesons such as $\pi^+$'s, $K^+$'s, $D^0$'s and $B^+$'s. These relations allow for the study of finite-density systems in arbitrary volumes, and the study of high-density systems. Systems comprised of up to N=12 m mesons can be explored with Lattice QCD calculations utilizing $m$ different sources for the quark propagators. As the recursion relations require only a small, N-independent, number of operations to derive the N+1 meson contractions from the N meson contractions, they are compuationally feasible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BurstMem: A high-performance burst buffer system for scientific applications

The growth of computing power on large-scale systems requires commensurate high-bandwidth I/O systems. Many parallel file systems are designed to provide fast sustainable I/O in response to applications' soaring requirements. To meet this need, a novel system is imperative to temporarily buffer the bursty I/O and gradually flush datasets to long-term parallel file systems. In this paper, we introduce the design of BurstMem, a high-performance burst buffer system. BurstMem provides a storage framework with efficient storage and communication management strategies. Our experiments demonstrate that BurstMem is able to speed up the I/O performance of scientific applications by up to 8.5× on leadership computer systems.

Wang, Teng↗

Hyperbolification of dynamical systems: The case of continuous-time systems

We present a new method to generate chaotic hyperbolic systems. The method is based on the knowledge of a chaotic hyperbolic system and the use of a synchronization technique. This procedure is called hyperbolification of dynamical systems. The aim of this process is to create or enhance the hyperbolicity of a dynamical system. In other words, hyperbolification of dynamical systems produces chaotic hyperbolic (structurally stable) behaviors in a system that would not otherwise be hyperbolic. The method of hyperbolification can be outlined as follows. We consider a known n-dimensional hyperbolic chaotic system as a drive system and another n-dimensional system as the response system plus a feedback control function to be determined in accordance with a specific synchronization criterion. We then consider the error system and apply a synchronization method, and find sufficient conditions for the errors to converge to zero and hence the synchronization between the two systems to be established. This means that we construct a 2n-dimensional continuous-time system that displays a robust hyperbolic chaotic attractor. An illustrative example is given to show the effectiveness of the proposed hyperbolification method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems

Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awareness of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators’ situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: • Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. • Online detection and location of a major event (location, time, size, and type, such as generator or line outage). • Near-real-time event replay (in seconds) after a major event occurs. • Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interaction of feel system and flight control system dynamics on lateral flying qualities

An investigation of feel system and flight control system dynamics on lateral flying qualities was conducted using the variable stability USAF NT-33 aircraft. Experimental variations in feel system natural frequency, force-deflection gradient, control system command architecture type, flight control system filter frequency, and control system delay were made. The experiment data include pilot ratings using the Cooper-Harper (1969) rating scale, pilot comments, and tracking performance statistic. Three test pilots served as evaluators. The data indicate that as the feel system natural frequency is reduced lateral flying qualities degrade. At the slowest feel system frequency, the closed-loop response becomes nonlinear with a 'bobweight' effect apparent in the feel system. Feel system influences were essentially independent of the control system architecture. The flying qualities influence due to the feel system was different than when the identical dynamic systenm was used as a flight control system element.

Bailey, Randall E.↗

Space station integrated propulsion and fluid systems study. Space station program fluid management systems databook

Commonality and integration of propulsion and fluid systems associated with the Space Station elements are being evaluated. The Space Station elements consist of the core station, which includes habitation and laboratory modules, nodes, airlocks, and trusswork; and associated vehicles, platforms, experiments, and payloads. The program is being performed as two discrete tasks. Task 1 investigated the components of the Space Station architecture to determine the feasibility and practicality of commonality and integration among the various propulsion elements. This task was completed. Task 2 is examining integration and commonality among fluid systems which were identified by the Phase B Space Station contractors as being part of the initial operating capability (IOC) and growth Space Station architectures. Requirements and descriptions for reference fluid systems were compiled from Space Station documentation and other sources. The fluid systems being examined are: an experiment gas supply system, an oxygen/hydrogen supply system, an integrated water system, the integrated nitrogen system, and the integrated waste fluids system. Definitions and descriptions of alternate systems were developed, along with analyses and discussions of their benefits and detriments. This databook includes fluid systems descriptions, requirements, schematic diagrams, component lists, and discussions of the fluid systems. In addition, cost comparison are used in some cases to determine the optimum system for a specific task.

Bicknell, B.↗

Intelligent systems technology infrastructure for integrated systems

Significant advances have occurred during the last decade in intelligent systems technologies (a.k.a. knowledge-based systems, KBS) including research, feasibility demonstrations, and technology implementations in operational environments. Evaluation and simulation data obtained to date in real-time operational environments suggest that cost-effective utilization of intelligent systems technologies can be realized for Automated Rendezvous and Capture applications. The successful implementation of these technologies involve a complex system infrastructure integrating the requirements of transportation, vehicle checkout and health management, and communication systems without compromise to systems reliability and performance. The resources that must be invoked to accomplish these tasks include remote ground operations and control, built-in system fault management and control, and intelligent robotics. To ensure long-term evolution and integration of new validated technologies over the lifetime of the vehicle, system interfaces must also be addressed and integrated into the overall system interface requirements. An approach for defining and evaluating the system infrastructures including the testbed currently being used to support the on-going evaluations for the evolutionary Space Station Freedom Data Management System is presented and discussed. Intelligent system technologies discussed include artificial intelligence (real-time replanning and scheduling), high performance computational elements (parallel processors, photonic processors, and neural networks), real-time fault management and control, and system software development tools for rapid prototyping capabilities.

Lum, Henry, Jr.↗

Optimal Sizing of a Solar-Plus-Storage System for Utility Bill Savings and Resiliency Benefits

Solar-plus-storage systems can achieve significant utility savings in behind-the-meter deployments in buildings, campuses, or industrial sites. Common applications include demand charge reduction, energy arbitrage, time-shifting of excess photovoltaic (PV) production, and selling ancillary services to the utility grid. These systems can also offer some energy resiliency during grid outages. It is often difficult to quantify the amount of resiliency that these systems can provide, however, and this benefit is often undervalued or omitted during the design process. We propose a method for estimating the resiliency that a solar-plus-storage system can provide at a given location. We then present an optimization model that can optimally size the system components to minimize the lifecycle cost of electricity to the site, including the costs incurred during grid outages. The results show that including the value of resiliency during the feasibility stage can result in larger systems and increased resiliency.

14 SOLAR ENERGY↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Post-Disturbance Dynamic Distribution System Restoration with DGs and Mobile Resources

Distributed generations (DGs) can act as emergency power supplies when distribution systems suffer from outages. However, the generation capabilities of DGs are generally limited by a number of factors including weather conditions, fuel limitations, etc. In this context, mobile resources that are able to reallocate resources to desired locations are regarded as important complements to conventional fixed DGs in assisting distribution system restoration. In this paper, a distribution system restoration model with DGs and mobile resources is proposed. Firstly, the dispatch and allocation of mobile resources are modeled with respect to the characteristics of the traffic network. Then the developed mobile resource models are integrated into the distribution system restoration model to co-optimize the scheduling of DGs and mobile resources. Uncertainty factors are managed by a model predictive control approach so that system operators can dynamically adjust the restoration strategy with the up-to-date information. The effectiveness of the proposed method is validated through an IEEE 13-bus test system.

distributed generations (DGs)↗