Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine

High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-Level Quantum Systems in Two-Dimensional Materials for Single Photon Emission

Single photon emission (SPE) by a solid-state source requires presence of a distinct two-level quantum system, usually provided by point defects. Here we note that a number of qualities offered by novel, two-dimensional materials, their all-surface openness and optical transparence, tighter quantum confinement, and reduced charge screening—are advantageous for achieving an ideal SPE. On the basis of first-principles calculations and point-group symmetry analysis, a strategy is proposed to design paramagnetic defect complex with reduced symmetry, meeting all the requirements for SPE: its electronic states are well isolated from the host material bands, belong to a majority spin eigenstate, and can be controllably excited by polarized light. Here, the defect complex is thermodynamically stable and appears feasible for experimental realization to serve as an SPE-source, essential for quantum computing, with Re Mo V S in MoS 2 as one of the most practical candidates.

36 MATERIALS SCIENCE↗

Hydrogen refinement during solid phase epitaxy of buried amorphous silicon layers

The effect of hydrogen on the kinetics of solid phase epitaxy (SPE) have been studied in buried amorphous Si layers. The crystallization rate of the front amorphous/crystalline (a/c) interface is monitored with time resolved reflectivity. Secondary ion mass spectrometry (SIMS) is used to examine H implanted profiles at selected stages of the anneals. The H retardation of the SPE rate is determined up to a H concentration of 2.3x10{sup 20} cm{sup -3} where the SPE rate decreases by 80%. Numerical simulations are performed to model the H diffusion, the moving a/c interfaces and the refinement of the H profile at these interfaces. Despite the high H concentration involved, a simple Fickian diffusion model results in good agreement with the SIMS data. The segregation coefficient is estimated to be 0.07 at 575 deg. C. A significant fraction of the H escapes from the a-Si layer during SPE especially once the two a/c interfaces meet which is signified by the lack of H-related voids after a subsequent high temperature anneal.

36 MATERIALS SCIENCE↗

Temperature dependent dielectric properties and ion transportation in solid polymer electrolyte for lithium ion batteries

Solid polymer electrolyte (SPE) film consisted of poly(ethylene oxide) (PEO) and poly(methyl methacrylate) (PMMA) blend matrix with lithium tetrafluroborate (LiBF{sub 4}) as dopant ionic salt and poly(ethylene glycol) (PEG) as plasticizer has been prepared by solution casting method followed by melt pressing. Dielectric properties and ionic conductivity of the SPE film at different temperatures have been determined by dielectric relaxation spectroscopy. It has been observed that the dc ionic conductivity of the SPE film increases with increase of temperature and also the decrease of relaxation time. The temperature dependent relaxation time and ionic conductivity values of the electrolyte are governed by the Arrhenius relation. Correlation observed between dc conductivity and relaxation time confirms that ion transportation occurs with polymer chain segmental dynamics through hopping mechanism. The room temperature ionic conductivity is found to be 4 × 10{sup −6} S cm{sup −1} which suggests the suitability of the SPE film for rechargeable lithium batteries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

OCCURRENCE OF EXTREME SOLAR PARTICLE EVENTS: ASSESSMENT FROM HISTORICAL PROXY DATA

The probability of occurrence of extreme solar particle events (SPEs) with proton fluence (>30 MeV) F{sub 30} {>=} 10{sup 10} cm{sup -2} is evaluated based on data on the cosmogenic isotopes {sup 14}C and {sup 10}Be in terrestrial archives covering centennial-millennial timescales. Four potential candidates with F{sub 30} = (1-1.5) Multiplication-Sign 10{sup 10} cm{sup -2} and no events with F{sub 30} > 2 Multiplication-Sign 10{sup 10} cm{sup -2} are identified since 1400 AD in the annually resolved {sup 10}Be data. A strong SPE related to the Carrington flare of 1859 AD is not supported by the data. For the last 11,400 years, 19 SPE candidates with F{sub 30} = (1-3) Multiplication-Sign 10{sup 10} cm{sup -2} are found and clearly no event with F{sub 30} > 5 Multiplication-Sign 10{sup 10} cm{sup -2} (50 times the SPE of 1956 February 23) has occurred. These values serve as observational upper limits on the strength of SPEs on the timescale of tens of millennia. Two events, ca. 780 and 1460 AD, appear in different data series making them strong candidates for extreme SPEs. We build a distribution of the occurrence probability of extreme SPEs, providing a new strict observational constraint. Practical limits can be set as F{sub 30} Almost-Equal-To 1, 2-3, and 5 Multiplication-Sign 10{sup 10} cm{sup -2} for occurrence probabilities Almost-Equal-To 10{sup -2}, 10{sup -3}, and 10{sup -4} yr{sup -1}, respectively. Because of the uncertainties, our results should be interpreted as a conservative upper limit on the SPE occurrence near Earth. The mean solar energetic particle (SEP) flux is evaluated as Almost-Equal-To 40 (cm{sup 2} s){sup -1}, in agreement with estimates from lunar rocks. On average, extreme SPEs contribute about 10% to the total SEP fluence.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Ground Motion from An Underground Chemical Explosion

Here in this paper we investigate the excitation and propagation of far-field seismic waves from the 905 kg trinitrotoluene equivalent underground chemical explosion SPE-3 recorded during the Source Physics Experiment (SPE) at the Nevada National Security Site. The recorded far-field ground motion at short and long distances is characterized by substantial shear-wave energy, and large azimuthal variations in P-and S-wave amplitudes. The shear waves observed on the transverse component of sensors at epicentral distances <50 m suggests they were generated at or very near the source. The relative amplitude of the shear waves grows as the waves propagate away from the source. We analyze and model the shear-wave excitation during the explosion in the 0.01–10 Hz frequency range, at epicentral distances of up to 1 km. We used two simulation techniques. One is based on the empirical isotropic Mueller–Murphy (MM) (Mueller and Murphy, 1971) nuclear explosion source model, and 3D anelastic wave propagation modeling. The second uses a physics-based approach that couples hydrodynamic modeling of the chemical explosion source with anelastic wave propagation modeling. Comparisons with recorded data show the MM source model overestimates the SPE-3 far-field ground motion by an average factor of 4. The observations show that shear waves with substantial high-frequency energy were generated at the source. However, to match the observations additional shear waves from scattering, including surface topography, and heterogeneous shallow structure contributed to the amplification of far-field shear motion. Comparisons between empirically based isotropic and physics-based anisotropic source models suggest that both wave-scattering effects and near-field nonlinear effects are needed to explain the amplitude and irregular radiation pattern of shear motion observed during the SPE-3 explosion.

58 GEOSCIENCES↗

Infrasound Predictions Using the Weather Research and Forecasting Model: Atmospheric Green's Functions for the Source Physics Experiments 1-6.

This report shows the results of constructing predictive atmospheric models for the Source Physics Experiments 1-6. Historic atmospheric data are combined with topography to construct an atmo- spheric model that corresponds to the predicted (or actual) time of a given SPE event. The models are ultimately used to construct atmospheric Green's functions to be used for subsequent analysis. We present three atmospheric models for each SPE event: an average model based on ten one- hour snap shots of the atmosphere and two extrema models corresponding to the warmest, coolest, windiest, etc. atmospheric snap shots. The atmospheric snap shots consist of wind, temperature, and pressure profiles of the atmosphere for a one-hour time window centered at the time of the predicted SPE event, as well as nine additional snap shots for each of the nine preceding years, centered at the time and day of the SPE event.

54 ENVIRONMENTAL SCIENCES↗

Detecing Surface Change Created by an Underground Chemical Explosion Using Fully Polarimetric VideoSAR

Sandia National Laboratories (SNL) flew its Facility for Advanced RF and Algorithm Development (FARAD) X-Band (9.6 GHz center frequency), fully-polarimetric synthetic aperture radar (PolSAR) in VideoSAR-mode to collect complex-valued SAR imagery before, during, and after the fifth and sixth Source Physics Experiment's (SPE-5 and SPE-6) underground explosion. The results from the fifth Source Physics Experiment (SPE-5) used single-polarimetric VideoSAR data while SPE-6 used single and fully-polarimetric VideoSAR data. We show that SAR can provide surface change products indicative of disturbances caused by the underground chemical explosions. These are surface coherence measures, Po1SAR change signatures, and differential interferometric SAR (InSAR) height change.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Predicting Atmospheric Green's Functions using the Weather Research and Forecasting Model

This report shows the results of constructing predictive atmospheric models for the Source Physics Experiments 1-6. Historic atmospheric data are combined with topography to construct an atmospheric model that corresponds to the predicted (or actual) time of a given SPE event. The models are ultimately used to construct atmospheric Green's functions to be used for subsequent analysis. We present three atmospheric models for each SPE event: an average model based on ten one-hour snap shots of the atmosphere and two extrema models corresponding to the warmest, coolest, windiest, etc. atmospheric snap shots. The atmospheric snap shots consist of wind, temperature, and pressure profiles of the atmosphere for a one-hour time window centered at the time of the predicted SPE event, as well as nine additional snap shots for each of the nine preceding years, centered at the time and day of the SPE event.

54 ENVIRONMENTAL SCIENCES↗

Material Property Determinations for Rock Valley Legacy Samples in Support of Source Physics Experiment

The Source Physics Experiment (SPE) is a long-term NNSA research and development effort designed to improve nonproliferation verification and monitoring capabilities. The overarching goals of the SPE program are to improve understanding of prompt signals and physical signatures that develop from underground chemical explosions and associated modeling capabilities. Our work focuses on a primary factor controlling chemical explosion induced signals and signatures: the material properties of the rocks in which the chemical explosion takes place. This document reports on material property determinations of legacy core USGS Test Well F and outcrop analogs for the subsurface stratigraphy for the third phase of SPE in the Rock Valley (RV) area of the Nevada National Security Site (NNSS). The objective of this work is to establish a baseline set of lithologic descriptions and material properties expected prior to observatory borehole drilling in support of the SPE-RVDC (Rock Valley Direct Comparison) experiment. We determine for each rock type the compressional failure envelope, elastic properties as a function of stress (bulk modulus versus mean stress, shear modulus versus shear stress, Young’s modulus versus axial stress and Poisson’s ratio versus axial stress), indirect tensile strength, and porosity. Geologic characterization, both at the core-scale and microscale, provides context for using the data in modeling efforts and to inform interpretations for the material properties testing.

36 MATERIALS SCIENCE↗

Mechanisms of Low Dose Radiation-induced T helper Cell Function

Exposure to radiation above levels normally encountered on Earth can occur during wartime, accidents such as those at Three Mile Island and Chernobyl, and detonation of “dirty bombs” by terrorists. Relatively high levels of radiation exposure can also occur in certain occupations (low-level waste sites, nuclear power plants, nuclear medicine facilities, airline industry, and space agencies). Depression or dysfunction of the highly radiosensitive cells of the immune system can lead to serious consequences, including increased risk for infections, cancer, hypersensitivity reactions, poor wound healing, and other pathologies. The focus of this research was on the T helper (Th) subset of lymphocytes that secrete cytokines (proteins), and thus control many actions and interactions of other cell types that make up what is collectively known as the immune system. The Department of Energy (DOE) Low Dose Radiation Program is concerned with mechanisms altered by exposure to high energy photons (x- and gamma-rays), protons and electrons. This study compared, for the first time, the low-dose effects of two of these radiation forms, photons and protons, on the response of Th cells, as well as other cell types with which they communicate. The research provided insights regarding gene expression patterns and capacity to secrete potent immunostimulatory and immunosuppressive cytokines, some of which are implicated in pathophysiological processes. Furthermore, the photon versus proton comparison was important not only to healthy individuals who may be exposed, but also to patients undergoing radiotherapy, since many medical centers in the United States, as well as worldwide, are now building proton accelerators. The overall hypothesis of this study was that whole-body exposure to low-dose photons (gamma-rays) will alter CD4+ Th cell function. We further proposed that exposure to low-dose proton radiation will induce a different pattern of gene and functional changes compared to photons. Over the course of this research, tissues other than spleens were archived and with funding obtained from other sources, including the Department of Radiation Medicine at the Loma Linda University Medical Center, some additional assays were performed. Furthermore, groups of additional mice were included that were pre-exposed to low-dose photons before irradiating with acute photons, protons, and simulated solar particle event (SPE) protons. Hence, the original support together with the additional funding for our research led to generation of much valuable information that was originally not anticipated. Some of the data has already resulted in published articles, manuscripts in review, and a number of presentations at scientific conferences and workshops. Difficulties in reliable and reproducible quantification of secreted cytokines using multi-plex technology delayed completion of this study for a period of time. However, final analyses of the remaining data are currently being performed and should result in additional publications and presentations in the near future. Some of the most notable conclusions, thus far, are briefly summarized below: - Distribution of leukocytes were dependent upon cell type, radiation quality, body compartment analyzed, and time after exposure. Low-dose protons tended to have less effect on numbers of major leukocyte populations and T cell subsets compared to low-dose photons. - The patterns of gene and cytokine expression in CD4+ T cells after protracted low-dose irradiation were significantly modified and highly dependent upon the total dose and time after exposure. - Patterns of gene and cytokine expression differed substantially among groups exposed to low-dose photons versus low-dose protons; differences were also noted among groups exposed to much higher doses of photons, protons, and simulated SPE protons. - Some measurements indicated that exposure to low-dose photon radiation, especially 0.01 Gy, significantly “normalized” at least some adverse effects of simulated SPE protons, thereby suggesting that this low level of radiation may induce protective mechanisms against a relatively large radiation event. - Analysis of signal transduction pathways in CD4+ T cells showed that whole-body priming with 0.01 Gy photons before exposure to simulated SPE protons significantly increased expression of p38MAPK and NF-kappaB, while JNK expression was decreased. Overall, it appears that the p38MAPK signaling pathway may be most important in inducing a radioprotective response.

43 PARTICLE ACCELERATORS↗

Novel One-Step Production of Carbon-Coated Sn Nanoparticles for High-Capacity Anodes in Lithium-Ion Batteries

Lithium-ion batteries offer the highest energy density of any currently available portable energy storage technology. By using different anode materials, these batteries could have an even greater energy density. One material, tin, has a theoretical lithium capacity (994 mAh/g) over three-times higher than commercial carbon anode materials. Unfortunately, to achieve this high capacity, bulk tin undergoes a large volume expansion, and the material pulverizes during cycling, giving a rapid capacity fade. To mitigate this issue, tin must be scaled down to the nano-level to take advantage of unique micromechanics at the nanoscale. Synthesis techniques for Sn nanoparticle anodes are costly and overly complicated for commercial production. A novel one-step process for producing carbon-coated Sn nanoparticles via spark plasma erosion (SPE) shows great promise as a simple, inexpensive production method. The SPE method, characterization of the resulting particles, and their high-capacity reversible electrochemical performance as anodes are described. With only a 10% addition of these novel SPE carbon-coated Sn particles, one anode composition demonstrated a reversible capacity of ~460 mAh/g, achieving the theoretical capacity of that particular electrode formulation. These SPE carbon-coated Sn nanoparticles are drop-in ready for present commercial lithium-ion anode processing and would provide a ~10% increase in the total capacity of current commercial lithium-ion cells.

25 ENERGY STORAGE↗

The effects of solar particle events on the middle atmosphere

Solar particle events (SPEs) have been investigated since the late 1960's for possible effects on the middle atmosphere. Solar protons from SPEs produce ionizations, dissociations, dissociative ionizations, and excitations in the middle atmosphere. The production of HO(x) and NO(x) and their subsequent effects on ozone can also be computed using energy deposition and photochemical models. The effects of SPE-produced HO(x) species on the odd nitrogen abundance of the middle atmosphere as well as the SPE-produced long term effects on ozone. Model computations indicate fairly good agreement with ozone data for the SPE-induced ozone depletion caused by NO(y) species connected with the August 1972 SPE. The model computations indicate that NO(y) will not be substantially changed over a solar cycle by SPEs. The changes are mainly at high latitudes and are on time scales of several months, after which the NO(y) drifts back to its ambient levels.

Jackman, Charles H.↗

Description, analysis and impact of major solar activity during recent U.S. Shuttle missions

Since STS-26, three large solar events have occurred during Shuttle missions: a geomagnetic storm during STS-29 and solar particle events (SPEs) during STS-28 and -34. The maximum dose to a crew attributed to an SPE was estimated to be 30 micro-Gy. Time-resolved dosimetry measurements of the SPE dose during STS-28 were made using the USAF Radiation Monitoring Equipment. Comparison of calculated and measured dose demonstrated a discrepancy, possibly a result of deficiencies in the geomagnetic cutoff model used. This experience demonstrates that dose from an SPE is strongly dependent on numerous factors such as orbit inclination, SPE start time, spectral parameters and geomagnetic field conditions; the exact combination of these factors is fortuitous. New sources of data and procedures are being investigated, including real-time tracking of auroral oval positions or determination of particle cutoff latitudes, for incorporation into operational Shuttle radiation support practices.

Golightly, M. J.↗

Active Regions on the Farside of the Sun as Seen from Mars: 3D Visualization with Marie Data

From March 2002, the MARIE (Martian Radiation Environment Experiment) instrument of NASA-JSC onboard the 2001 Mars Odyssey spacecraft has been providing radiation data from the Martian orbit. During the past two years, the orbit alignment of Mars-Sun-Earth provided a wealth of opportunity between 180 degrees (August 2002) and 0 degrees (October 2003). During this time, the MARIE data included the background GCR (Galactic Cosmic Rays) and several SPE (Solar Particle Events) enhanced radiation dose-rate measurements at Mars. The MARIE instrument provided a unique data set of radiation dose-rate at Mars from the active regions on the solar disk facing the Mars side. The SPE observations of October 2002 at Mars by the MARIE instrument are unique and there were no indications of these events towards the Earth at that time. Nearly 40 times increase in the quiet-time GCR dose-rate was noted from about 25 mradday to nearly 1000 mradday at Mars. Radiation dose-rate enhancement was not observed toward the Earth or in the Low Earth Orbit (LEO) during this time. Understanding the active regions on the Sun that are likely to result into SPE on the far side will also be of concern for future deep space explorations beyond LEO. We present the observations of these SPE enhanced dose rates due to the active regions from the far side of the Sun with the 3D visualization of solar disks facing Mars and Earth.

Saganti, P. B.↗

Science Goals in Radiation Protection for Exploration

Space radiation presents major challenges to future missions to the Earth s moon or Mars. Health risks of concern include cancer, degenerative and performance risks to the central nervous system, heart and lens, and the acute radiation syndromes. The galactic cosmic rays (GCR) contain high energy and charge (HZE) nuclei, which have been shown to cause qualitatively distinct biological damage compared to terresterial radiation, such as X-rays or gamma-rays, causing risk estimates to be highly uncertain. The biological effects of solar particle events (SPE) are similar to terresterial radiation except for their biological dose-rate modifiers; however the onset and size of SPEs are difficult to predict. The high energies of GCR reduce the effectiveness of shielding, while SPE s can be shielded however the current gap in radiobiological knowledge hinders optimization. Methods used to project risks on Earth must be modified because of the large uncertainties in projecting health risks from space radiation, and thus impact mission requirements and costs. We describe NASA s unique approach to radiation safety that applies probabilistic risk assessments and uncertainty based criteria within the occupational health program for astronauts and to mission design. The two terrestrial criteria of a point estimate of maximum acceptable level of risk and application of the principle of As Low As Reasonably Achievable (ALARA) are supplemented by a third requirement that protects against risk projection uncertainties using the upper 95% confidence level (CL) in radiation risk projection models. Exploration science goals in radiation protection are centered on ground-based research to achieve the necessary biological knowledge, and in the development of new technologies to improve SPE monitoring and optimize shielding. Radiobiology research is centered on a ground based program investigating the radiobiology of high-energy protons and HZE nuclei at the NASA Space Radiation Laboratory (NSRL) located at DoE s Brookhaven National Laboratory in Upton, NY. We describe recent NSRL results that are closing the knowledge gap in HZE radiobiology and improving exploration risk estimates. Linking probabilistic risk assessment to research goals makes it possible to express risk management objectives in terms of quantitative metrics, which include the number of days in space without exceeding a given risk level within well defined confidence limits, and probabilistic assessments of the effectiveness of design trade spaces such as material type, mass, solar cycle, crew selection criteria, and biological countermeasures. New research in SPE alert and risk assessment, individual radiation sensitivity, and biological countermeasure development are described.

Cucinotta, Francs A.↗

Predictions of Leukemia Risks to Astronauts from Solar Particle Events

Leukemias consisting of acute and chronic myeloid leukemia and acute lymphatic lymphomas represent the earliest cancers that appear after radiation exposure, have a high lethality fraction, and make up a significant fraction of the overall fatal cancer risk from radiation for adults. Several considerations impact the recommendation of a preferred model for the estimation of leukemia risks from solar particle events (SPE's): The BEIR VII report recommends several changes to the method of calculation of leukemia risk compared to the methods recommended by the NCRP Report No. 132 including the preference of a mixture model with additive and multiplicative components in BEIR VII compared to the additive transfer model recommended by NCRP Report No. 132. Proton fluences and doses vary considerably across marrow regions because of the characteristic spectra of primary solar protons making the use of an average dose suspect. Previous estimates of bone marrow doses from SPE's have used an average body-shielding distribution for marrow based on the computerized anatomical man model (CAM). We have developed an 82-point body-shielding distribution that faithfully reproduces the mean and variance of SPE doses in the active marrow regions (head and neck, chest, abdomen, pelvis and thighs) allowing for more accurate estimation of linear- and quadratic-dose components of the marrow response. SPE's have differential dose-rates and a pseudo-quadratic dose response term is possible in the peak-flux period of an event. Also, the mechanistic basis for leukemia risk continues to improve allowing for improved strategies in choosing dose-rate modulation factors and radiation quality descriptors. We make comparisons of the various choices of the components in leukemia risk estimates in formulating our preferred model. A major finding is that leukemia could be the dominant risk to astronauts for a major solar particle event.

Cucinotta, F. A.↗

Multiplexed Colorimetric Solid-Phase Extraction

Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

Gazda, Daniel B.↗