At least 217 records · Page 12

The double pentaladder integral to all orders

We compute dual-conformally invariant ladder integrals that are capped off by pentagons at each end of the ladder. Such integrals appear in six-point amplitudes in planar N = 4 super-Yang-Mills theory. We provide exact, finite-coupling formulas for the basic double pentaladder integrals as a single Mellin integral over hypergeometric functions. For particular choices of the dual conformal cross ratios, we can evaluate the integral at weak coupling to high loop orders in terms of multiple polylogarithms. We argue that the integrals are exponentially suppressed at strong coupling. Here in this paper, we describe the space of functions that contains all such double pentaladder integrals and their derivatives, or coproducts. This space, a prototype for the space of Steinmann hexagon functions, has a simple algebraic structure, which we elucidate by considering a particular discontinuity of the functions that localizes the Mellin integral and collapses the relevant symbol alphabet. This function space is endowed with a coaction, both perturbatively and at finite coupling, which mixes the independent solutions of the hypergeometric differential equation and constructively realizes a coaction principle of the type believed to hold in the full Steinmann hexagon function space.

1/N Expansion↗

Detection of terahertz radiation by tightly concatenated InGaAs field-effect transistors integrated on a single chip

A tightly concatenated chain of InGaAs field-effect transistors with an asymmetric T-gate in each transistor demonstrates strong terahertz photovoltaic response without using supplementary antenna elements. We obtain the responsivity above 1000 V/W and up to 2000 V/W for unbiased and drain-biased transistors in the chain, respectively, with the noise equivalent power below 10{sup −11} W/Hz{sup 0.5} in the unbiased mode of the detector operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reprogrammable field programmable gate array with integrated system for mitigating effects of single event upsets

An integrated system mitigates the effects of a single event upset (SEU) on a reprogrammable field programmable gate array (RFPGA). The system includes (i) a RFPGA having an internal configuration memory, and (ii) a memory for storing a configuration associated with the RFPGA. Logic circuitry programmed into the RFPGA and coupled to the memory reloads a portion of the configuration from the memory into the RFPGA's internal configuration memory at predetermined times. Additional SEU mitigation can be provided by logic circuitry on the RFPGA that monitors and maintains synchronized operation of the RFPGA's digital clock managers.

Ng, Tak-kwong↗

Integrated work management system.

Sandia National Laboratories develops technologies to: (1) sustain, modernize, and protect our nuclear arsenal (2) Prevent the spread of weapons of mass destruction; (3) Provide new capabilities to our armed forces; (4) Protect our national infrastructure; (5) Ensure the stability of our nation's energy and water supplies; and (6) Defend our nation against terrorist threats. We identified the need for a single overarching Integrated Workplace Management System (IWMS) that would enable us to focus on customer missions and improve FMOC processes. Our team selected highly configurable commercial-off-the-shelf (COTS) software with out-of-the-box workflow processes that integrate strategic planning, project management, facility assessments, and space management, and can interface with existing systems, such as Oracle, PeopleSoft, Maximo, Bentley, and FileNet. We selected the Integrated Workplace Management System (IWMS) from Tririga, Inc. Facility Management System (FMS) Benefits are: (1) Create a single reliable source for facility data; (2) Improve transparency with oversight organizations; (3) Streamline FMOC business processes with a single, integrated facility-management tool; (4) Give customers simple tools and real-time information; (5) Reduce indirect costs; (6) Replace approximately 30 FMOC systems and 60 homegrown tools (such as Microsoft Access databases); and (7) Integrate with FIMS.

99 GENERAL AND MISCELLANEOUS↗

Effects of Eye Measures on Human Controller Remnant and Control Behavior

The aim of the current research was to investigate the possible relation between changes in eye activity parameters, variations in human remnant at the perceptual level and changes in human operator model parameters. Fourteen subjects performed a pitch tracking task, in which the display brightness was varied by changing the background color around a simplified primary flight display, in order to create a controlled, quasilinear change in the pupil diameter through the pupillary light reflex. Pupil diameter, blink, eye opening, and opening and closing amplitudes and speeds were recorded using an eye tracker. Participants controlled single integrator-like and double integrator-like dynamics. The variation in pupil diameter did not introduce significant differences in neither remnant characteristics nor the human operator model parameters. An interesting effect occurred in the human controller’s time delay for the single integrator task, where the time delay was significantly higher for the darkest brightness compared to the other levels of brightness. This effect was not observed for the double integrator dynamics. Data suggested that the more difficult controlled dynamics induced a squinting effect, visible in smaller eye opening, and smaller eye opening and closing amplitudes. These results suggest that performance, and control behavior are invariant to the display brightness. Moreover, monitoring changes in the eye activity could represent a method of predicting variations in human remnant characteristics and human controller model parameters, introduced by task difficulty.

Eye tracking↗

OVERVIEW OF HANFORD SINGLE SHELL TANK (SST) STRUCTURAL INTEGRITY - 12123

To improve the understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. Seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The structural integrity of the tanks is a key element in completing the cleanup mission at the Hanford Site. There are eight primary recommendations related to the structural integrity of Hanford SSTs. Six recommendations are being implemented through current and planned activities. The structural integrity of the Hanford SSTs is being evaluated through analysis, monitoring, inspection, materials testing, and construction document review. Structural evaluation in the form of analysis is performed using modern finite element models generated in ANSYS{reg_sign} The analyses consider in-situ, thermal, operating loads and natural phenomena such as earthquakes. Structural analysis of 108 of 149 Hanford SSTs has concluded that the tanks are structurally sound and meet current industry standards. Analyses of the remaining Hanford SSTs are scheduled for FY2013. Hanford SSTs are monitored through a dome deflection program. The program looks for deflections of the tank dome greater than 1/4 inch. No such deflections have been recorded. The tanks are also subjected to visual inspection. Digital cameras record the interior surface of the concrete tank domes, looking for cracks and other surface conditions that may indicate signs of structural distress. The condition of the concrete and rebar of the Hanford SSTs is currently being tested and planned for additional activities in the near future. Concrete and rebar removed from the dome of a 65-year-old tank is being tested for mechanics properties and condition. Results indicated stronger than designed concrete with additional Petrographic examination and rebar testing ongoing. Material properties determined from previous efforts combined with current testing and construction document review will help to generate a database that will provide continuing indication of Hanford SST structural integrity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DUNE DAQ R&D integration in ProtoDUNE Single-Phase at CERN

The DAQ system of ProtoDUNE-SP successfully proved its design principles and met the requirements of the beam run of 2018. The technical design of the DAQ system for the DUNE experiment has major differences compared to the prototype due to different requirements placed on the detector, as well as a radically different location of operation. The single-phase prototype at CERN is a major integration facility for R&D aspects of the DUNE DAQ system. The facility allows for the exploration of additional data processing capabilities and optimization of the FELIX system, which is the chosen TPC readout solution for the DUNE single-phase detectors. One of the fundamental differences from the prototype is that the DUNE DAQ relies on self-triggering. Therefore, real-time processing of the data stream for hit and trigger primitive finding is essential for the requirement of continuous readout. The supernova burst trigger requires a large and fast buffering technique, where 3D XPoint persistent memory solutions are evaluated and integrated. In order to maximize resource utilization of the FELIX hosting servers, the elimination of the 100 Gb network communication stack is desired. This implies the design and development of a single-host application layer, which is a fundamental element of the self-triggering chain. This paper discusses the evaluation and integration of these developments for the DUNE DAQ, in the ProtoDUNE environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design - working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching.

54 ENVIRONMENTAL SCIENCES↗