Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras

Purpose: The purpose of this project is to build a volumetric scintillation detector for quantitative imaging of 3D dose distributions of proton beams accurately in near real-time. Methods: The liquid scintillator (LS) detector consists of a transparent acrylic tank (20×20×20 cm{sup 3}) filled with a liquid scintillator that when irradiated with protons generates scintillation light. To track rapid spatial and dose variations in spot scanning proton beams we used three scientific-complementary metal-oxide semiconductor (sCMOS) imagers (2560×2160 pixels). The cameras collect optical signal from three orthogonal projections. To reduce system footprint two mirrors oriented at 45° to the tank surfaces redirect scintillation light to cameras for capturing top and right views. Selection of fixed focal length objective lenses for these cameras was based on their ability to provide large depth of field (DoF) and required field of view (FoV). Multiple cross-hairs imprinted on the tank surfaces allow for image corrections arising from camera perspective and refraction. Results: We determined that by setting sCMOS to 16-bit dynamic range, truncating its FoV (1100×1100 pixels) to image the entire volume of the LS detector, and using 5.6 msec integration time imaging rate can be ramped up to 88 frames per second (fps). 20 mm focal length lens provides a 20 cm imaging DoF and 0.24 mm/pixel resolution. Master-slave camera configuration enable the slaves to initiate image acquisition instantly (within 2 µsec) after receiving a trigger signal. A computer with 128 GB RAM was used for spooling images from the cameras and can sustain a maximum recording time of 2 min per camera at 75 fps. Conclusion: The three sCMOS cameras are capable of high speed imaging. They can therefore be used for quick, high-resolution, and precise mapping of dose distributions from scanned spot proton beams in three dimensions.

60 APPLIED LIFE SCIENCES↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Separation of scintillation and Cherenkov lights in linear alkyl benzene

To separate scintillation and Cherenkov lights in water-based liquid scintillator detectors is a desired feature for future neutrino and proton decay experiments. Linear alkyl benzene (LAB) is one important ingredient of a water-based liquid scintillator currently under development. In this paper we report on the separation of scintillation and Cherenkov lights observed in an LAB sample. The rise and decay times of the scintillation light are measured to be (7.7±3.0)ns and (36.6±2.4)ns, respectively, while the full width [–3σ, 3σ] of the Cherenkov light is 12 ns and is dominated by the time resolution of the photomultiplier tubes. Here, the scintillation light yield was measured to be (1.01±0.12)×103photons/MeV .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Ultrafast Scintillators with Core Valence Luminescence: Cs 2 MgCl 4 and Cs 3 MgCl 5

Future experiments in high energy physics and medical imaging require radiation detectors having properties which are not presently available. The main limitations arise from lack of suitable scintillation crystals. This dilemma prompts the need for research leading to the discovery of new fast and bright scintillator materials that combine unique properties to fulfil modern experiment requirements without compromises. In this work, single crystals of Cs 2 MgCl 4 and Cs 3 MgCl 5 up to 12 mm in diameter are grown via the vertical Bridgman method. Scintillation properties are reported for the first time, and core valence luminescence is observed for both compounds. X-ray excited radioluminescence emission of Cs 2 MgCl 4 is centered at 295 nm, with a scintillation decay time of 2.25 ± 0.05 ns and relatively high core-valence light yield of 2,200 ± 110 ph/MeV. Cs 3 MgCl 5 has two main emission peaks centered at 242 nm and 302 nm, decay time of 1.46 ± 0.05 ns, and light yield of 1,340 ± 70 ph/MeV. The better coincidence time resolution (CTR) is obtained with Cs 2 MgCl 4 , which is measured to be 129 ± 4 ps FWHM. Density functional theory (DFT) calculations are also performed and provide supporting evidence that the observed scintillation originates from core valence luminescence. Furthermore, the combination of speed and brightness of these new scintillators could be useful for fast timing applications in which moderately dense materials are required.

36 MATERIALS SCIENCE↗

350 ps Ultrafast room-temperature scintillation realized on CsPbBr 3 -based single crystals via Br 2 over-doping

Ultrafast scintillators are essential for next-generation radiation detection, positron emission tomography, and high-speed medical imaging. All-inorganic CsPbBr 3 perovskites are attractive candidates because of their high stopping power, and excellent optical quality, yet their long carrier lifetimes result in slow scintillation responses on the order of hundreds of nanoseconds. Here, we demonstrate that controlled over-doping with Br 2 produces CsPbBr 3.03 single crystals with sub-nanosecond scintillation at room temperature while preserving crystal quality. Single crystals grown by the Bridgman method exhibit high transparency and maintain the orthorhombic perovskite structure. Br 2 over-doping induces a slight lattice expansion (about 0.42% increase in unit-cell volume) while maintaining the orthorhombic perovskite phase and high optical transparency. Optical absorption reveals a slight redshift of the absorption edge after Br 2 introduction, indicating a modified defect landscape. Time-resolved photoluminescence and radioluminescence measurements show that Br 2 doping creates dense and efficient recombination centers that reduce the scintillation decay time from more than 100 ns in undoped crystals to 350 ps under 5.486 MeV α-particle excitation, and the scintillation decay time decreases by two orders of magnitude. The doped crystals also achieve a spatial resolution of 12 lp mm −1 in X-ray imaging. These results reveal a defect-engineering route for achieving ultrafast scintillation in halide perovskites and highlight the potential of Br 2 -modified CsPbBr 3 for fast timing applications.

Li, Zongxiao [Chinese Academy of Sciences (CAS), N↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Capture-gated Spectroscopic Measurements of Monoenergetic Neutrons with a Composite Scintillation Detector

Abstract—We report on the measurements of Monoenergetic neutrons from DD and DT fusion reactions by use of the capture gating method in a heterogeneous plastic-glass composite scintillation detector. The cylindrical detector is 5.08 cm in diameter and 5.05 cm in height and was fabricated using 1-mm diameter Li-doped glass rods(GS20) and scintillating polyvinyl toluene (EJ-290). Different scintillation decay constants are used to identify energy depositions in two materials constituting the composite scintillator. Geant4 simulations of the neutron thermalization and capture process were conducted, finding a mean capture time of approximately 2.6 ms for both DD and DT neutrons. A capture gating time acceptance window based on simulation results was used to identify the neutron thermalization pulses. The total scintillation light yield produced in neutron thermalization was measured and found to show consistency on event-by-event basis despite the variety of neutron thermalization histories prior to capture. The ratio of light yields from thermalization of 14.1 MeV and 2.45 MeV neutrons in the EJ-290 scintillator was determined to be 14.6, and the light output from 2.45 MeV neutrons was also correlated to its electron equivalent, obtaining a value of 0.58*0.05 MeVee.

47 OTHER INSTRUMENTATION↗

SU-E-T-108: An Investigation of Cerenkov Light Production in the Exradin W1 Scintillator Under Various Measurement Conditions

Purpose: To investigate the effects of depth, fiber-optic cable bends, and incident radiation angle on Cerenkov production in the Standard Imaging Exradin W1. Methods: Measurements were completed using a Varian Clinac 21EX linear accelerator with an Exradin W1 scintillator as well as a cable-only scintillator (no scintillation material) to isolate the Cerenkov signal. The effects of cable bend radius and location were investigated by bending the fiber-optic cable into a circle with radii ranging from 1.0 to 10.8 cm and positioning the center of the coil at distances ranging from 10.0 to 175.0 cm from the photodiode. The effects of depth and incident radiation angle were investigated by performing measurements in water at depths ranging from 1.0 cm to 25.0 cm and angles ranging from 0° to 80°. Eclipse treatment-planning software was utilized to ensure a consistent dose was delivered to the W1 regardless of depth or angle. Results: Measured signal in both channels of the cable-only scintillator decreased as the bend radius decreased and as the distance between the bend and photodiode increased. A fiber bend of 1.0 cm radius produced a 17.1% decrease in the green channel response in the cable-only scintillator. The effect of depth was less severe; a maximum increase of 6.6% in the green channel response was observed at a depth of 25.0 cm in the W1. In the angular dependence investigation, the signal in both channels of the W1 peaked at an angle of 40°; which is in agreement with the nominal Cerenkov emission angle of 45°. Conclusion: The green channel response in the W1 (mainly Cerenkov signal) varied with depth, fiber-optic cable bends, and incident radiation angle. Fully characterizing Cerenkov production is essential to ensure it is properly accounted for in scintillator measurements. Research funding and materials received by Standard Imaging, Inc. (Middleton WI)

07 ISOTOPE AND RADIATION SOURCES↗

WE-DE-BRA-04: A Cost-Effective Pixelated EPID Scintillator for Enhanced Contrast and DQE

Purpose: Beams-eye-view imaging applications such as real-time soft-tissue motion estimation and MV-CBCT are hindered by the inherently low image contrast of electronic portal imaging devices (EPID) currently in clinical use. We investigate a cost effective scintillating glass that provides substantially increased detective quantum efficiency (DQE) and contrast to noise ratio (CNR). Methods: A pixelated scintillator prototype was built from LKH-5 glass. The array is 12mm thick; 42.4×42.4cm2 wide and features 1.51mm pixel pitch with 20µm separation (glue+septa). The LKH-5 array was mounted on the active matrix flat panel imager (AMPFI) of an AS-1200 (Varian) with the GdO2S2:Tb removed. A second AS-1200 was utilized as reference detector. The prototype EPID was characterized in terms of CNR, modulation transfer function (MTF) and DQE. Additionally, the visibility of various fiducial markers typically used in the clinic as well as a realistic 3D-printed lung tumor model was assessed. All items were placed in a 12cm thick solid water phantom. CNR is estimated using a Las Vegas contrast phantom, presampled MTF is estimated using a slanted slit technique and the DQE is calculated from measured normalized noise power spectra (NPS) and the MTF. Results: DQE(0) for the LKH-5 prototype increased by a factor of 8× to about 10%, compared to the AS-1200 equipped with its standard GdO2S2:Tb scintillator. CNR increased by a factor of 5.3×. Due to the pixel size the MTF50 decreased by about 55% to 0.23lp/mm. The visibility of all fiducial markers as well as the tumor model were however markedly improved in comparison to an acquisition with the same parameters using the GdO2S2:Tb scintillator. Conclusion: LKH-5 scintillating glasses allow the cost effective construction of thick pixelated scintillators for portal imaging which can yield a substantial increase in DQE and CNR. Soft tissue and fiducial marker visibility was found to be markedly improved. The project was supported in part by NIH grant R01CA188446-01 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Final Report on Actinide Glass Scintillators for Fast Neutron Detection

This is the final report of an experimental investigation of actinide glass scintillators for fast-neutron detection. It covers work performed during FY2012. This supplements a previous report, PNNL-20854 “Initial Characterization of Thorium-loaded Glasses for Fast Neutron Detection” (October 2011). The work in FY2012 was done with funding remaining from FY2011. As noted in PNNL-20854, the glasses tested prior to July 2011 were erroneously identified as scintillators. The decision was then made to start from “scratch” with a literature survey and some test melts with a non-radioactive glass composition that could later be fabricated with select actinides, most likely thorium. The normal stand-in for thorium in radioactive waste glasses is cerium in the same oxidation state. Since cerium in the 3+ state is used as the light emitter in many scintillating glasses, the next most common substitute was used: hafnium. Three hafnium glasses were melted. Two melts were colored amber and a third was clear. It barely scintillated when exposed to alpha particles. The uses and applications for a scintillating fast neutron detector are important enough that the search for such a material should not be totally abandoned. This current effort focused on actinides that have very high neutron capture energy releases but low neutron capture cross sections. This results in very long counting times and poor signal to noise when working with sealed sources. These materials are best for high flux applications and access to neutron generators or reactors would enable better test scenarios. The total energy of the neutron capture reaction is not the only factor to focus on in isotope selection. Many neutron capture reactions result in energetic gamma rays that require large volumes or high densities to detect. If the scintillator is to separate neutrons from gamma rays, the capture reactions should produce heavy particles and few gamma rays. This would improve the detection of a signal for fast neutron capture.

Actinide Glass↗

Mixed-Material Scintillators (MMSS Quarterly Report FY20Q2)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. This quarter, we delivered one the MMSS Particle-ID Modeling report, a major deliverable of this project. This report describes our results on simulations of the particle-ID (PID) class of detectors. We found that these detectors outperform competing approaches for neutron-gamma discrimination, neutron source pointing, and neutron spectroscopy. Further highlights of the report are described below. During this quarter, We alerted HQ to a change in schedule for the remaining simulations planned for this project: we plan to put off further simulation and reporting of the position-resolving (PR) detector class until July. This change in schedule has allowed us to go into additional detail in the PID work that is both very promising and motivates our upcoming proposal. The other active task in this project is prototyping 3D-printed scintillators with the aim of realizing the designs we’ve simulated. On that front, we had three focuses: measuring the light output, increasing the size of printed parts, and combining blue and green scintillators. We succeeded in measuring the light output, showing an output of 30% of commercial standard. This result leaves room for improvement but is within striking distance of where we need to be. We were on track to demonstrate a key requirement for increasing the size of parts and also to show combined green/blue prints before the laboratory moved to a Minimum Safe (MinSafe) Operations posture as a result of local Shelter In Place orders due to Covid-19.

42 ENGINEERING↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗

Mixed Material Scintillator Systems Quarterly Report FY20Q4

This project aims to invent, model, and prototype architected multimaterial scintillator systems (AMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (AM, i.e. 3D printing) of scintillator, a currently emerging application of additive manufacture technology. AMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising AMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. In past reporting, we have described this detector concept as “mixed material scintillator systems” (MMSS), but as part of preparing papers for publication we have concluded the term “architected multimaterial scintillator systems” (AMSS) better reflects the importance of structure in these detectors. We plan to use the AMSS acronym going forward. This quarter, we participated in an Independent Assessment of the work so far. The panelists on the review concluded that the AMSS concept has great potential and our work so far was effective at bringing that potential to light. They highly encouraged further work on this topic. The panelists also had several useful suggestions, which we took to heart. This review is described in more detail below. This quarter saw a resumption of work on the final task of this project, prototyping. In the first half of the quarter, this work focused on solving specific technical barriers to achieve 1x1x1 cm prints. In the second half, we focused on producing high-quality samples and making characterization measurements of those samples, with an eye on our deliverable report on the prototyping task. This report can be expected along with the end-of-year report on October 30. This project successfully spent the entirety of its remaining funds this quarter, except for $13k refunded to this project in the last days of the fiscal year due to LLNL cost adjustments. This project has captured the interest of many LLNL experts, and so we have been able to effectively use our budget to harness the available effort.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

University Partnership Program for Scintillator Materials Research

The Scintillation Detection Development (SDD) group of the Particle Physics Division (PPD) at Fermi National Accelerator Laboratory (Fermilab) conducts research and development work in the field of materials that exhibit scintillation properties for use in particle detection and identification in nuclear and high energy physics experiments and applications. SDD has established a University Partnership Program for Scintillator Materials Research (Program), to facilitate collaboration with faculty and students from local universities. The collaboration between the SDD group and Dominican University will address the development of new plastic scintillating materials in two ways: 3.1. Synthesis of new organic fluorescent compounds to test with plastics commonly used in scintillation applications 3.2. Preparation and testing of commercially available plastics known for their resilience to radiation and rarely used in scintillation applications

43 PARTICLE ACCELERATORS↗