Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

Koh, Chung-Yan↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

Facile One-Pot Nanoproteomics for Label-Free Proteome Profiling of 50–1000 Mammalian Cells

Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contribution from Ising domains overlapping out-of-plane to perpendicular magnetic anisotropy in Mn 4 N thin films on MgO(001)

Single phase ε-Mn4N thin and ultrathin films are grown on MgO(001) using molecular beam epitaxy. Reflection high-energy electron diffraction and outof-plane x-ray diffraction measurements are taken for each sample in order to determine the in- and out-of-plane strain for each sample. Vibrating sample magnetometry and superconducting quantum interference device measurements, which are performed on the thin and ultrathin films respectively, are used to plot the magnetization of each sample versus both in- and out-of-plane $\vec H$-fields and to determine the magnitude of perpendicular magnetic anisotropy in these films. Three significant components of perpendicular magnetic anisotropy are observed in these films and are attributed to sample strain (1 component) and shape (2 components). Among these components, the most significant component (0.8 to 4.9 $\frac{Merg}{cm^3}$) is identified as a second term of shape anisotropy, which possesses a negative linear relationship with sample thickness over the range from 9 nm to 310 nm. Atomic (magnetic) force microscopy measurements show the presence of a surface localized magnetic polarization (22% to 82%), which increases with decreasing thickness, when the net magnetization of the films is zero. The second term of shape anisotropy as well as the surface localized polarization, which each depend on sample thickness, are each regarded as a consequence of Ising domains overlapping out-of-plane in these films.

Materials Science↗

Freeform thermoelectrics in single-step manufacturing: additive manufacturing of bismuth-telluride thermoelectrics

The project succeeded in producing crack-free Bismuth Telluride thermoelectric parts with density exceeding 98% through laser powder bed fusion (LPBF) additive manufacturing (AM). This greatly exceeded the highest previously reported density of 88% and is the highest among all semiconducting materials processed by LPBF. The additively manufactured material shows comparable Seebeck coefficient as conventional form and can be made into complex geometries with reduced material loss. On the other hand, measured properties are dramatically sensitive to the AM process parameters used, such that with identical composition, the Seebeck coefficient can be controllably tuned from +120 µV/K to -207 µV/K, which means the material switches between an n-type to a p-type semiconductor depending on processing. These changes are accompanied by significant differences in the as-processed microstructure due to rapid solidification. A machine learning protocol was developed and greatly reduced the experimental burden of the project, reducing the typical process optimization period of 2 years to 6 months. The project was fully successful in the objective of producing defect-free, complex geometry of bismuth-telluride parts through LPBF, but only partially successful in achieving performance goals. First, cost reduction of manufacturing, as measured by material waste, was successfully reduced by up to 70% compared to conventional manufacturing methods. This exceeded the proposed 30% reduction in materials waste needed to reach the 20% cost reduction goal of the project. On the other hand, the device performance, as measured by Seebeck coefficient, failed to reach the 40% improvement in efficiency. Rather, we observe comparable Seebeck coefficient between AM samples and conventionally processed counterparts. The device-level efficiency improvement does exceed 40% for complex geometry samples due to shape-induced increase in temperature gradients, but this was not the originally proposed metric. The machine learning approach developed in this project greatly accelerated the process optimization and can be adopted for fast development of AM processing parameters for other brittle and otherwise difficult-to-print materials. For the public, we deliver an efficient and widely adoptable process for incorporating waste-heat harvesting thermoelectric devices in both industrial and commercial heat exchangers. The geometric flexibility allows the capturing device to conform to the shape of the heat source to improve the system-level conversion efficiency. The technique can be deployed on any commercial LBPF systems with zero modifications, thus poses minimal adoption barrier for any manufacturer that already employed AM technology. Beyond bismuth-telluride, the machine-learning guided optimization protocol can be used in the future to reduce both the time and cost of process development for AM of other energy conversion and harvesting materials.

36 MATERIALS SCIENCE↗

A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B, for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.

Wang, Yijia↗

Significant Efficiency Enhancements in Non‐Y Series Acceptors by the Addition of Outer Side Chains

Abstract Most current highly efficient organic solar cells utilize small molecules like Y6 and its derivatives as electron acceptors in the photoactive layer. In this work, a small molecule acceptor, SC8‐IT4F, is developed through outer side chain engineering on the terminal thiophene of a conjugated 6,12‐dihydro‐dithienoindeno[2,3‐d:2′,3′‐d′]‐s‐indaceno[1,2‐b:5,6‐b′]dithiophene (IDTT) central core. Compared to the reference molecule C8‐IT4F, which lacks outer side chains, SC8‐IT4F displays notable differences in molecule geometry (as shown by simulations), thermal behavior, single‐crystal packing, and film morphology. Blend films of SC8‐IT4F and the polymer donor PM6 exhibit larger carrier mobilities, longer carrier lifetimes, and reduced recombination compared to C8‐IT4F, resulting in improved device performance. Binary photovoltaic devices based on the PM6:SC8‐IT4F films reveal an optimal efficiency over 15%, which is one of the best values for non‐Y type small molecule acceptors (SMAs). The resultant devices also show better thermal and operational stability than the control PM6:L8‐BO devices. SC8‐IT4F and its blend exhibit a higher relative degree of crystallinity and π coherence length, compared to C8‐IT4F samples, beneficial for charge transport and device performance. The results indicate that outer side chain engineering on existing small electron acceptors can be a promising molecular design strategy for further pursuing high‐performance organic solar cells.

He, Qiao [Department of Chemistry and Centre for P↗

Visualization of Current and Mapping of Elements in Quantum Dot Solar Cells

The delicate influence of properties such as high surface state density and organic-inorganic boundaries on the individual quantum dot electronic structure complicates pursuits toward forming quantitative models of quantum dot thin films ab initio. Our report describes the application of electron beam-induced current (EBIC) microscopy to depleted-heterojunction colloidal quantum dot photovoltaics (DH-CQD PVs), a technique which affords one a map of current production within the active layer of a PV device. The effects of QD sample size polydispersity as well as layer thickness in CQD active layers as they pertain to current production within these PVs are imaged and explained. The results from these experiments compare well with previous estimations, and confirm the ability of EBIC to function as a valuable empirical tool for the design and betterment of DH-CQD PVs. Lastly, extensive and unexpected PbS QD penetration into the mesoporous TiO 2 layer is observed through imaging of device cross sections by energy-dispersive X-ray spectroscopy combined with scanning transmission electron microscopy. Finally, the effects of this finding are discussed and corroborated with the EBIC studies on similar devices.

14 SOLAR ENERGY↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ferromagnetism Near Room Temperature in the Cleavable van der Waals Crystal Fe 5 GeTe 2

Two-dimensional materials with intrinsic functionality are becoming increasingly important in exploring fundamental condensed matter science and for developing advanced technologies. Bulk crystals that can be exfoliated are particularly relevant to these pursuits as they provide the opportunity to study the role of physical dimensionality and explore device physics in highly crystalline samples and designer heterostructures in a routine manner. Magnetism is a key element in these endeavors; however, relatively few cleavable materials are magnetic and none possess magnetic order at ambient conditions. Here, we introduce Fe 5–x GeTe 2 as a cleavable material with ferromagnetic behavior at room temperature. We established intrinsic magnetic order at room temperature in bulk crystals ( = 310 K) through magnetization measurements and in exfoliated, thin flakes (T C ≈ 280 K) using the anomalous Hall effect. Our work reveals Fe 5 GeTe 2 as a prime candidate for incorporating intrinsic magnetism into functional van der Waals heterostructures and devices near room temperature.

36 MATERIALS SCIENCE↗

Digitization of scalar fields for quantum computing

Qubit, operator, and gate resources required for the digitization of lattice λΦ 4 scalar field theories onto quantum computers are considered, building upon the foundational work by Jordan et al. [Quantum Inf. Comput. 14, 1014 (2014); Science 336, 1130 (2012)], with a focus towards noisy intermediate-scale quantum devices. The Nyquist-Shannon sampling theorem, introduced in this context by Macridin et al. [Phys. Rev. A 98, 042312 (2018)] building on the work of Somma [Quantum Inf. Comput. 16, 1125 (2016)], provides a guide with which to evaluate the efficacy of two field-space bases, the eigenstates of the field operator, as used by Jordan et al., and eigenstates of a harmonic oscillator, to describe ( 0 + 1 )- and ( d + 1 )-dimensional scalar field theory. We show how techniques associated with improved actions, which are heavily utilized in lattice QCD calculations to systematically reduce lattice-spacing artifacts, can be used to reduce the impact of the field digitization in λΦ 4 , but are found to be inferior to a complete digitization improvement of the Hamiltonian using a quantum Fourier transform. When the Nyquist-Shannon sampling theorem is satisfied, digitization errors scale as | log | log | ε dig | | | ~ n Q (number of qubits describing the field at a given spatial site) for the low-lying states, leaving the familiar power-law lattice-spacing and finite-volume effects that scale as | log | ε latt | | ~ N Q (total number of qubits in the simulation). For localized (delocalized) field-space wave functions, it is found that n Q ~ 4 ( 7 ) qubits per spatial lattice site are sufficient to reduce theoretical digitization errors below error contributions associated with approximation of the time-evolution operator and noisy implementation on near-term quantum devices. Only classical computing resources have been used to obtain the results presented in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IR-Live: fabrication of a low-cost plastic microfluidic device for infrared spectromicroscopy of living cells

Water is a strong mid-infrared absorber, which has hindered the full exploitation of label-free and non-invasive infrared (IR) spectromicroscopy techniques for the study of living biological samples. To overcome this barrier, many researchers have built sophisticated fluidic chambers or microfluidic chips wherein the depth of the liquid medium in the sample compartment is limited to 10 μm or less. We report an innovative and simple way to fabricate plastic devices with infrared transparent view-ports enabling infrared spectromicroscopy of living biological samples; therefore the device is named “IR-Live”. Advantages of this approach include lower production costs, a minimal need to access a micro-fabrication facility, and unlimited mass or waste exchange for the living samples surrounding the view-port area. We demonstrate that the low-cost IR-Live in combination with microfluidic perfusion techniques enables long term (>60 h) cell culture, which broadens the capability of IR spectromicroscopy for studying living biological samples. To illustrate this, we first applied the device to study protein and lipid polarity in migrating REF52 fibroblasts by collecting 2-dimensional spectral chemical maps at a micrometer spatial resolution. Then, we demonstrated the suitability of our approach to study dynamic cellular events by collecting a time series of spectral maps of U937 monocytes during the early stage of cell attachment to a bio-compatible surface.

47 OTHER INSTRUMENTATION↗

Resistive switching: An investigation of the bipolar–unipolar transition in Co-doped ZnO thin films

Highlights: • A purely bipolar behavior on a Co-doped ZnO thin film has been demonstrated. • We have shown what can happen if a unipolar test is performed in a purely bipolar device. • An explanation for how a sample can show a purely bipolar switching behavior was suggested. • An important open issue about resistive switching effect was put in debate. - Abstract: In order to investigate the resistive switching effect we built devices in a planar structure in which two Al contacts were deposited on the top of the film and separated by a small gap using a shadow mask. Therefore, two samples of 10% Co-doped ZnO thin films were sputtered on glass substrate. High resolution X-ray diffraction (HRXRD) revealed a highly c-axis oriented crystalline structure, without secondary phase. The high resolution scanning electron microscopy (HRSEM) showed a flat surface with good coverage and thickness about 300 nm. A Keithley 2425 semiconductor characterization system was used to perform the resistive switching tests in the bipolar and unipolar modes. Considering only the effect of compliance current (CC), the devices showed a purely bipolar behavior since an increase in CC did not induce a transition to unipolar behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high bandwidth microelectromechanical system-based nanopositioner for scanning tunneling microscopy

Limited Z-axis bandwidth of piezotube scanners used in conventional Scanning Tunneling Microscopes (STMs) has been a major limiting factor in achieving high scan speeds in STM applications. Slow Z-axis dynamics of typical piezotube scanners combined with the weight of the STM tip/tip holder assembly, that the scanner has to carry, substantially limit the achievable Z-axis bandwidth in both imaging and lithography modes. To tackle this issue, we introduce a high bandwidth microelectromechanical-system-based nanopositioner to be integrated into an existing STM scanner. The device is designed to replace the STM tip and fine Z-positioning mechanisms in the conventional STM setup, while providing an order of magnitude higher bandwidth in Z axis. The device is microfabricated using double silicon-on-isolator technology, and standard cleanroom processes. Experiments show that tunneling current between the device tip and a highly ordered pyrolytic graphite sample can be successfully established and maintained in air using the proposed device in a feedback loop. Results suggest that the proposed device uniquely combines a very high resolution and a large stroke with a substantially larger Z-axis bandwidth compared to that of conventional STM piezotube scanners, enabling higher scanning speeds in STM operations.

42 ENGINEERING↗