Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Off-line-locked laser diode species monitor system

An off-line-locked laser diode species monitor system includes: reference means for including at least one known species having a first absorption wavelength; a laser source for irradiating the reference means and at least one sample species having a second absorption wavelength differing from the first absorption wavelength by a predetermined amount; means for locking the wavelength of the laser source to the first wavelength of the at least one known species in the reference means; a controller for defeating the means for locking and for displacing the laser source wavelength from said first absorption wavelength by said predetermined amount to the second absorption wavelength; and a sample detector device for determining laser radiation absorption at the second wavelength transmitted through the sample to detect the presence of the at least one sample species.

Lee, Jamine↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advantages of a Synchrotron Bending Magnet as the Sample Illuminator for a Wide-field X-ray Microscope

In our paper the choice between bending magnets and insertion devices as sample illuminators for a hard X-ray full-field microscope is investigated. An optimized bending-magnet beamline design is presented. Its imaging speed is very competitive with the performance of similar microscopes installed currently at insertion-device beamlines. The fact that imaging X-ray microscopes can accept a large phase space makes them very well suited to the output characteristics of bending magnets which are often a plentiful and paid-for resource. There exist opportunities at all synchrotron light sources to take advantage of this finding to build bending-magnet beamlines that are dedicated to transmission X-ray microscope facilities. We expect that demand for such facilities will increase as three-dimensional tomography becomes routine and advanced techniques such as mosaic tomography and XANES tomography (taking three-dimensional tomograms at different energies to highlight elemental and chemical differences) become more widespread.

42 ENGINEERING↗

OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

OSIRIS-REX TOUCH-AND-GO (TAG) MISSION DESIGN FOR A↗

High Quantum Efficiency Uni-Traveling-Carrier Photodiode for Optical to Microwave Transduction

Modern Quantum Information Systems (QIS) employ optical photons for long distance communication, operating at ambient temperature, between microwave cavities, which house microwave photons used in quantum computing and microwave detection. These optical photons, carried by fiber-optic or free-space links, offer a low-cost, uncooled alternative to bulky, expensive microwave coaxial cables, which are lossy, susceptible to EMI, and a significant thermal conductor to the outside ambient environment. To convert between these two types of photons and implement these optical interconnects, it is necessary to develop a high-performance photodetector for optical to microwave transduction. Freedom Photonics and the University of Virginia have a well-established partnership in developing high-performance photodiodes. In this Phase I effort, we collaborated in designing, fabricating, and testing an advanced, high-speed, high quantum efficiency prototype photodiode for transduction from optical to microwave frequencies. These devices have applications not only in quantum computing and axion detection, but also in other optical-cryogenic interconnect applications, in fields such as radio astronomy and quantum cryptography, as well as in quantum metrology and plasmonics. During this Phase I DOE program, we designed, fabricated, and tested prototype PIN GaAs photodiodes which targeted the performance parameters defined by the program. This process involved identifying a new target wavelength, different from that proposed initially, based on conversations with the Oak Ridge National Lab customer. We designed an epitaxial stack, optimized in theory for ≥95% quantum efficiency at 795 nm, ≥5 GHz, per the target objectives of the program. Additionally, we designed a fabrication process and associated mask plates for top-illuminated, AR-coated devices with device diameters ranging from 50 µm to 800 µm. Using these, we fabricated two 3” wafer quarters of devices, and characterized the devices’ dark current, quantum efficiency, and bandwidth for various device diameters. The prototype devices achieved a quantum efficiency of 89% at the target 795 nm detection wavelength. The bandwidth of the devices proved tricky to characterize, but a 50 µm diameter device shows a 3-dB bandwidth of at least 1.6 GHz, possibly a full 5 GHz, depending on the measurement setup. In the future, we plan to characterize the bandwidth of these devices using an impulse response measurement. All tasks for the Phase I were successfully completed, and sample prototype devices were provided to Oak Ridge National Lab Quantum Information Science researchers. The work performed in Phase I has established a strong foundation for future design and fabrication cycles in Phase II, if granted. The early tests at Oak Ridge National Labs will provide guidance for the required photodiode performance in devices to be supplied in Phase II.

42 ENGINEERING↗

Small Body GN and C Research Report: G-SAMPLE - An In-Flight Dynamical Method for Identifying Sample Mass [External Release Version]

G-SAMPLE is an in-flight dynamical method for use by sample collection missions to identify the presence and quantity of collected sample material. The G-SAMPLE method implements a maximum-likelihood estimator to identify the collected sample mass, based on onboard force sensor measurements, thruster firings, and a dynamics model of the spacecraft. With G-SAMPLE, sample mass identification becomes a computation rather than an extra hardware requirement; the added cost of cameras or other sensors for sample mass detection is avoided. Realistic simulation examples are provided for a spacecraft configuration with a sample collection device mounted on the end of an extended boom. In one representative example, a 1000 gram sample mass is estimated to within 110 grams (95% confidence) under realistic assumptions of thruster profile error, spacecraft parameter uncertainty, and sensor noise. For convenience to future mission design, an overall sample-mass estimation error budget is developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

in-flight sample-mass identification↗

Experimental Setup to Investigate Hydrogen Isotope Retention on Powder Samples as Slag/Dust Proxies for Advanced Fusion Reactors

Slag/dust formation is one of the critical issues regarding tritium retention in advanced fusion reactors. We upgraded an ultrahigh vacuum device, the sample exposure station (SES), to perform temperature-programmed desorption (TPD), also known as thermal desorption spectroscopy, to investigate deuterium (D) retention in powder samples that are utilized as proxies for slag/dust particles formed in fusion reactors. TPD analysis, calibrated for the desorption rate, was successfully performed on commercially available crystalline/amorphous boron (B) powder after D 2 neutral gas or D + ion exposure. We calibrated the B powder temperature measurement for TPD analysis utilizing a D 2 desorption peak from B-D bonding known for its desorption temperature ~700 K. We introduce a separation procedure of observed D TPD signals, convoluted for corresponding D retention pathways, that was necessary for TPD analysis. This is the first report on the retention of D 2 neutral gas to B, and this observation was enabled by utilizing the B powder sample, which has a larger surface area than films commonly used in laboratory experiments. In conclusion, the upgraded SES system will enable us to investigate hydrogen isotope behaviors for powder/dust samples of various elemental compositions, including metals.

Plasma-facing component debris↗

Fire safety experiments on MIR Orbital Station

The process of heterogeneous combustion of most materials under zero-g without forced motion of air is practically impossible. However, ventilation is required to support astronauts' life and cool equipment. The presence of ventilation flows in station compartments at accidental ignition can cause a fire. An additional, but exceedingly important parameter of the fire risk of solid materials under zero-g is the minimum air gas velocity at which the extinction of materials occurs. Therefore, the conception of fire safety can be based on temporarily lowering the intensity of ventilation and even turning it off. The information on the limiting conditions of combustion under natural conditions is needed from both scientific and practical points of view. It will enable us to judge the reliability of results of ground-based investigations and develop a conception of fire safety of inhabited sealed compartments of space stations to by provided be means of nontraditional and highly-effective methods without both employing large quantities of fire-extinguishing compounds and hard restrictions on use of polymers. In this connection, an experimental installation was created to study the process of heterogeneous combustion of solid non-metals and to determine the conditions of its extinction under microgravity. This installation was delivered to the orbital station 'Mir' and the cosmonauts Viktorenko and Kondakova performed initial experiments on it in late 1994. The experimental installation consists of a combustion chamber with an electrical systems for ignition of samples, a device for cleaning air from combustion products, an air suction unit, air pipes and a control panel. The whole experiment is controlled by telemetry and recorded with two video cameras located at two different places. Besides the picture, parameters are recorded to determine the velocity of the air flow incoming to the samples, the time points of switching on/off the devices, etc. The combustion chamber temperature is also controlled. The main objectives of experiments of this series were as follows: (1) verification of the reliability of the installation in orbital flight; (2) verification of the experimental procedure; and (3) investigation of combustion of two types of materials under microgravity at various velocities of the incoming air flow.

Egorov, S. D.↗

Infrastructure Investments in LAMDA: SEM Mill and Vault (NSUF 2019 Milestone Report)

This document summarizes the procurement, installation, and commissioning of a scanning electron microscope (SEM) mill produced by Fischione Instruments and a lead-shielded vault for specimen storage in support of Nuclear Science User Facility (NSUF) awards for use in Oak Ridge National Laboratory’s (ORNL) Low Activation Materials Development and Analysis (LAMDA) laboratory. The Model 1061 SEM mill is a tabletop ion milling system for advanced sample preparation of high-quality SEM samples. This device was chosen for its broad range of ion energies allowing for both rapid milling and final polishing of the sample surface. The purchase order with Fischione Instruments was released and awarded by ORNL procurement on September 11, 2018. The instrument was shipped in December of 2018 and was installed in the LAMDA laboratory in March of 2019. During the commissioning of this equipment, electron backscatter diffraction (EBSD) was performed on specimens before and after milling to show the enhanced surface quality. With the purchase of a lead vault dedicated to NSUF library materials co-located in the LAMDA laboratory, the NSUF program will be able to maintain a significant sample library in LAMDA. These specimens will be easily accessible for rapid turnaround experiment (RTE) awards and will reduce the overall cost of year-over-year storage and shipments to and from ORNL hot cell facilities. The contract to fabricate a fourth lead vault dedicated to NSUF specimen storage was awarded by ORNL procurement on August 10, 2018. Installation of the new vault was completed in January of 2019.

47 OTHER INSTRUMENTATION↗

Dynamic Method for Identifying Collected Sample Mass

G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

Carson, John↗

Heating system of pellet samples integrated with terahertz spectrometer

This article describes automation of temperature-dependent terahertz spectroscopic experiments. The proposed dual-heater temperature controller based on a cascade proportional-integral-derivative algorithm provides smooth temperature changes in the polyethylene-based pharmaceutical pellet samples. The device has been integrated with a terahertz time-domain spectrometer. Thermodynamic experiments can now be performed without any probe inserted into the measured sample. Selected results of temperature-induced evolution in terahertz spectra are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microgravity Testing of a Surface Sampling System for Sample Return from Small Solar System Bodies

The return of samples from solar system bodies is becoming an essential element of solar system exploration. The recent National Research Council Solar System Exploration Decadal Survey identified six sample return missions as high priority missions: South-Aitken Basin Sample Return, Comet Surface Sample Return, Comet Surface Sample Return-sample from selected surface sites, Asteroid Lander/Rover/Sample Return, Comet Nucleus Sample Return-cold samples from depth, and Mars Sample Return [1] and the NASA Roadmap also includes sample return missions [2] . Sample collection methods that have been flown on robotic spacecraft to date return subgram quantities, but many scientific issues (like bulk composition, particle size distributions, petrology, chronology) require tens to hundreds of grams of sample. Many complex sample collection devices have been proposed, however, small robotic missions require simplicity. We present here the results of experiments done with a simple but innovative collection system for sample return from small solar system bodies.

Franzen, M. A.↗

DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid, Sensitive, Label-Free Electrical Detection of SARS-CoV-2 in Nasal Swab Samples

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcriptionpolymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Finally, taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.

60 APPLIED LIFE SCIENCES↗

Novel Ultrafast Lu2O3:Yb Ceramics for Future HEP Applications

Inorganic scintillators activated by charge transfer luminescence Yb3+ are considered promising ultrafast material to break the ps timing barrier for future high energy physics applications. Inorganic scintillators in ceramic form are potentially more cost-effective than crystals because of their lower fabrication temperature and no need for aftergrowth mechanical processing. This paper reports an investigation on Lu2O3:Yb and Lu2xY2(1−x)O3:Yb scintillating ceramic samples fabricated by Radiation Monitoring Devices Inc. All samples show X-ray excited luminescence peaked at 370 nm. Ultrafast decay time of 1.1 ns was observed by using a microchannel plate-photomultiplier tube-based test bench at Caltech. Considering its intrinsic high density (9.4 g/cm3), Lu2O3:Yb ceramics are promising for future time of fight application for high energy physics experiments.

47 OTHER INSTRUMENTATION↗

Development of an in situ magnetoelastic magneto-optical Kerr effect magnetometer

Reported here is the development and implementation of an integrated in situ magnetoelastic measurement setup with a MOKE magnetometer, repositionable electromagnet, and sample transfer/straining device. The former were used within a molecular beam epitaxial vacuum growth chamber. Consequently the magnetostriction constants for both Cr capped and uncapped Fe/GaAs(100) films were acquired without film oxidization occurring. Samples were bent in a four point bending geometry to produce a quantifiable tensile mechanical strain on the films during magnetoelastic measurements. In addition, a laser measurement system was developed to confirm the induced strain in the samples.

36 MATERIALS SCIENCE↗

Cryogenic specimens for nanoscale characterization of solid–liquid interfaces

We report new cryogenic characterization techniques for exploring the nanoscale structure and chemistry of intact solid–liquid interfaces have recently been developed. These techniques provide high-resolution information about buried interfaces from large samples or devices that cannot be obtained by other means. These advancements were enabled by the development of instrumentation for cryogenic focused ion beam liftout, which allows intact solid–liquid interfaces to be extracted from large samples and thinned to electron-transparent thicknesses for characterization by cryogenic scanning transmission electron microscopy or atom probe tomography. Future implementation of these techniques will complement current strides in imaging of materials in fluid environments by in situ liquid-phase electron microscopy, providing a more complete understanding of the morphology, surface chemistry, and dynamic processes that occur at solid–liquid interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗