Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Pre-Flight Testing of Spaceborne GPS Receivers Using a GPS Constellation Simulator

The NASA Goddard Space Flight Center (GSFC) Global Positioning System (GPS) test facility has been established within the GSFC Guidance Navigation and Control Center. The GPS test facility is currently housing the STR2760 GPS satellite 40-channel attitude simulator and an STR4760 12-channel navigation simulator. The facility also contains a few other Goddard resources such as an atomic time standard test bed, a rooftop antenna platform and a radome. It provides a new capability of high dynamics GPS simulations for space flight that is unique within the aerospace community. The GPS facility gives a significant advantage in the development and support of GPS based technologies for position, attitude and precise time determination on-board a spacecraft, sounding rocket or balloon. The GPS simulator system is configured in a transportable rack and is available for GPS applications' component development as well as for spacecraft subsystem and system level testing at spacecraft integration and test sites. The GPS facility has been operational since early 1996 and has been already utilized by a few successful flight projects carrying GPS experiments, such as USA Seastar satellite and the first Argentine satellite SAC-A. The experience in the SAC-A pre-flight testing using the STR2760 simulator is summarized as well as the comparison with preliminary analysis of the GPS data from SAC-A telemetry.

Kizhner, Semion↗

Stress Dependence of Ultrasonic Velocity in Unidirectional Graphite/Epoxy Composites for Longitudinal Waves Propagating Along the Direction of Stress

The first measurements of the stress induced velocity changes for propagation directions along the direction of applied stress in gr/ep composites have been presented. For propagation and stress direction perpendicular to the fiber direction, the data demonstrated a linear relation between normalized velocity shift and stress. After corrections for the delay line were made, the slope or SAC was determined and compared favorably with the expected value calculated from the previously determined nonlinear coefficients of this material. The ratio of the SAC to the elastic compliance for this direction of loading was evaluated and found to have a value similar to numerous other materials which have very different linear elastic properties. Measurements with stress and propagation along the fibers yielded unusual behavior. The curves were very nonlinear and even shifted direction at higher loads. The large scatter in the data due to bond variations made separation of material effects from bond induced artifacts impossible. Thus the SAC, R, and the remaining two unknown TOEC's could not be determined for this direction of propagation. These measurements further expand the basis of determining nonlinear elastic properties of composite materials. These properties may be useful in developing much needed NDE techniques to determine such important parameters as residual stress after cure and residual strength after impact damage. Additional study is needed to measure the nonlinear behavior in other composite materials including angle ply laminates. Also, other techniques to measure elastic nonlinearity such as harmonic generation should be applied to composites to improve the understanding of these properties and their importance.

Prosser, William H.↗

Human cutaneous vascular responses to whole-body tilting, Gz centrifugation, and LBNP

We hypothesized that gravitational stimuli elicit cardiovascular responses in the following order with gravitational stress equalized at the level of the feet, from lowest to highest response: short-(SAC) and long-arm centrifugation (LAC), tilt, and lower body negative pressure (LBNP). Up to 15 healthy subjects underwent graded application of the four stimuli. Laser-Doppler flowmetry measured regional skin blood flow. At 0.6 G(z) (60 mmHg LBNP), tilt and LBNP similarly reduced leg skin blood flow to approximately 36% of supine baseline levels. Flow increased back toward baseline levels at 80-100 mmHg LBNP yet remained stable during 0.8-1.0 G(z) tilt. Centrifugation usually produced less leg vasoconstriction than tilt or LBNP. Surprisingly, SAC and LAC did not differ significantly. Thigh responses were less definitive than leg responses. No gravitational vasoconstriction occurred in the neck. All conditions except SAC increased heart rate, according to our hypothesized order. LBNP may be a more effective and practical means of simulating cardiovascular effects of gravity than centrifugation.

Motor Activity/physiology↗

Orbiting GPS Receiver Modified to Track New L2C Signal

The L2C signal is a great step forward for civil applications of GPS, enabling high-accuracy dual-frequency measurements. Engineers from the Jet Propulsion Laboratory and ITT teamed to reprogram FPGA firmware and add tracking software on an orbiting receiver to track the new GPS L2C signal from SAC-C. SAC-C is an Argentinean science satellite and was launched in November 2000 with a BlackJack GPS receiver. This is a dual-frequency digital receiver with 48 tracking channels and four antennas. On SAC-C, it provides precise orbits, atmospheric occultation data, tests of GPS surface reflections, and serves as an orbiting test bed for new GPS development such as the L2C tracking reported here.

GPS receiver↗

Targeted Discovery of Glycoside Hydrolases from a Switchgrass-Adapted Compost Community

Development of cellulosic biofuels from non-food crops is currently an area of intense research interest. Tailoring depolymerizing enzymes to particular feedstocks and pretreatment conditions is one promising avenue of research in this area. Here we added a green-waste compost inoculum to switchgrass (Panicum virgatum) and simulated thermophilic composting in a bioreactor to select for a switchgrass-adapted community and to facilitate targeted discovery of glycoside hydrolases. Smallsubunit (SSU) rRNA-based community profiles revealed that the microbial community changed dramatically between the initial and switchgrass-adapted compost (SAC) with some bacterial populations being enriched over 20-fold. We obtained 225 Mbp of 454-titanium pyrosequence data from the SAC community and conservatively identified 800 genes encoding glycoside hydrolase domains that were biased toward depolymerizing grass cell wall components. Of these, ,10percent were putative cellulasesmostly belonging to families GH5 and GH9. We synthesized two SAC GH9 genes with codon optimization for heterologous expression in Escherichia coli and observed activity for one on carboxymethyl cellulose. The active GH9 enzyme has a temperature optimum of 50uC and pH range of 5.5 to 8 consistent with the composting conditions applied. We demonstrate that microbial communities adapt to switchgrass decomposition using simulated composting condition and that full-length genes can be identified from complex metagenomic sequence data, synthesized and expressed resulting in active enzyme.

09 BIOMASS FUELS↗

Aeroelastic Modeling of Offshore Turbines and Support Structures in Hurricane-Prone Regions (Poster)

US offshore wind turbines (OWTs) will likely have to contend with hurricanes and the associated loading conditions. Current industry standards do not account for these design load cases (DLCs), thus a new approach is required to guarantee that the OWTs achieve an appropriate level of reliability. In this study, a sequentially coupled aero-hydro-servo-elastic modeling technique was used to address two design approaches: 1.) The ABS (American Bureau of Shipping) approach; and 2.) The Hazard Curve or API (American Petroleum Institute) approach. The former employs IEC partial load factors (PSFs) and 100-yr return-period (RP) metocean events. The latter allows setting PSFs and RP to a prescribed level of system reliability. The 500-yr RP robustness check (appearing in [2] and [3] upcoming editions) is a good indicator of the target reliability for L2 structures. CAE tools such as NREL's FAST and Bentley's' SACS (offshore analysis and design software) can be efficiently coupled to simulate system loads under hurricane DLCs. For this task, we augmented the latest FAST version (v. 8) to include tower aerodynamic drag that cannot be ignored in hurricane DLCs. In this project, a 6 MW turbine was simulated on a typical 4-legged jacket for a mid-Atlantic site. FAST-calculated tower base loads were fed to SACS at the interface level (transition piece); SACS added hydrodynamic and wind loads on the exposed substructure, and calculated mudline overturning moments, and member and joint utilization. Results show that CAE tools can be effectively used to compare design approaches for the design of OWTs in hurricane regions and to achieve a well-balanced design, where reliability levels and costs are optimized.

17 WIND ENERGY↗

Targeted discovery of glycoside hydrolases from a switchgrass-adapted compost community

Development of cellulosic biofuels from non-food crops is currently an area of intense research interest. Tailoring depolymerizing enzymes to particular feedstocks and pretreatment conditions is one promising avenue of research in this area. Here we added a green-waste compost inoculum to switchgrass (Panicum virgatum) and simulated thermophilic composting in a bioreactor to select for a switchgrass-adapted community and to facilitate targeted discovery of glycoside hydrolases. Small-subunit (SSU) rRNA-based community profiles revealed that the microbial community changed dramatically between the initial and switchgrass-adapted compost (SAC) with some bacterial populations being enriched over 20-fold. We obtained 225 Mbp of 454-titanium pyrosequence data from the SAC community and conservatively identified 800 genes encoding glycoside hydrolase domains that were biased toward depolymerizing grass cell wall components. Of these, {approx}10% were putative cellulases mostly belonging to families GH5 and GH9. We synthesized two SAC GH9 genes with codon optimization for heterologous expression in Escherichia coli and observed activity for one on carboxymethyl cellulose. The active GH9 enzyme has a temperature optimum of 50 C and pH range of 5.5 to 8 consistent with the composting conditions applied. We demonstrate that microbial communities adapt to switchgrass decomposition using simulated composting condition and that full-length genes can be identified from complex metagenomic sequence data, synthesized and expressed resulting in active enzyme.

09 BIOMASS FUELS↗

WHOLESCALE: Seismic Survey Data from San Emidio Nevada 2021

This dataset includes raw and processed seismic data from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 N, 119.409019 W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended at 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The dataset is hosted in an AWS data lake, with an associated GDR data set providing the metadata. Links to both of these resources are included below. Additionally, this collection features data and metadata from a 2016 seismic survey at the same site for comparative analysis.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Seismic Survey Metadata from San Emidio Nevada 2021

This is a collection of metadata from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 deg N, 119.409019 deg W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The raw and processed data are in an associated GDR submission, linked below. The metadata here includes files containing experiment details, station locations, seismic data logger specifications, instrumentation specifications, and descriptions of data. Also included are data and metadata from a 2016 seismic survey at the same site.

15 GEOTHERMAL ENERGY↗

Single‐Atom Electrocatalysts from Multivariate Metal–Organic Frameworks for Highly Selective Reduction of CO 2 at Low Pressures

Abstract Single‐atom catalysts (SACs) are of great interest because of their ultrahigh activity and selectivity. However, it is difficult to construct model SACs according to a general synthetic method, and therefore, discerning differences in activity of diverse single‐atom catalysts is not straightforward. Herein, a general strategy for synthesis of single‐atom metals implanted in N‐doped carbon (M 1 ‐N‐C; M=Fe, Co, Ni and Cu) has been developed starting from multivariate metal–organic frameworks (MOFs). The M 1 ‐N‐C catalysts, featuring identical chemical environments and supports, provided an ideal platform for differentiating the activity of single‐atom metal species. When employed in electrocatalytic CO 2 reduction, Ni 1 ‐N‐C exhibited a very high CO Faradaic efficiency (FE) up to 96.8 % that far surpassed Fe 1 ‐, Co 1 ‐ and Cu 1 ‐N‐C. Remarkably, the best‐performer, Ni 1 ‐N‐C, even demonstrated excellent CO FE at low CO 2 pressures, thereby representing a promising opportunity for the direct use of dilute CO 2 feedstock.

Jiao, Long↗

Boosting the Activity of Pd Single Atoms by Tuning Their Local Environment on Ceria for Methane Combustion

Abstract Supported Pd single atom catalysts (SACs) have triggered great research interest in methane combustion yet with contradicting views on their activity and stability. Here, we show that the Pd SAs can take different electronic structure and atomic geometry on ceria support, resulting in different catalytic properties. By a simple thermal pretreatment to ceria prior to Pd deposition, a unique anchoring site is created. The Pd SA, taking this site, can be activated to Pd δ + (0< δ <2) that has greatly enhanced activity for methane oxidation: T 50 lowered by up to 130 °C and almost 10 times higher turnover frequency compared to the untreated catalyst. The enhanced activity of Pd δ + site is related to its oxygen‐deficient local structure and elongated interacting distance with ceria, leading to enhanced capability in delivering reactive oxygen species and decomposing reaction intermediates. This work provides insights into designing highly efficient Pd SACs for oxidation reactions.

Yang, Weiwei↗

Single-Atom Electrocatalysts from Multivariate MOFs for Highly Selective Reduction of CO 2 at Low Pressures

Single-atom catalysts (SACs) are of great interest because of their ultrahigh activity and selectivity. However, it is difficult to construct model SACs according to a general synthetic method, and therefore, discerning differences in activity of diverse single-atom catalysts is not straightforward. Herein, a general strategy for synthesis of single-atom metals implanted in N-doped carbon (M 1 -N-C; M=Fe, Co, Ni and Cu) has been developed starting from multivariate metal–organic frameworks (MOFs). The M 1 -N-C catalysts, featuring identical chemical environments and supports, provided an ideal platform for differentiating the activity of single-atom metal species. When employed in electrocatalytic CO 2 reduction, Ni 1 -N-C exhibited a very high CO Faradaic efficiency (FE) up to 96.8 % that far surpassed Fe 1 -, Co 1 - and Cu 1 -N-C. Remarkably, the best-performer, Ni1-N-C, even demonstrated excellent CO FE at low CO 2 pressures, thereby representing a promising opportunity for the direct use of dilute CO 2 feedstock.

36 MATERIALS SCIENCE↗

Boosting the Activity of Pd Single Atoms by Tuning Their Local Environment on Ceria for Methane Combustion

Supported Pd single atom catalysts (SACs) have triggered great research interest in methane combustion yet with contradicting views on their activity and stability. Here, in this paper, we show that the Pd SAs can take different electronic structure and atomic geometry on ceria support, resulting in different catalytic properties. By a simple thermal pretreatment to ceria prior to Pd deposition, a unique anchoring site is created. The Pd SA, taking this site, can be activated to Pd δ+ (0<δ<2) that has greatly enhanced activity for methane oxidation: T 50 lowered by up to 130 °C and almost 10 times higher turnover frequency compared to the untreated catalyst. The enhanced activity of Pd δ+ site is related to its oxygen-deficient local structure and elongated interacting distance with ceria, leading to enhanced capability in delivering reactive oxygen species and decomposing reaction intermediates. This work provides insights into designing highly efficient Pd SACs for oxidation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Modified Metallic Coil Embolization Technique for Pulmonary Arteriovenous Malformations Using Coil Anchors and Occlusion Balloon Catheters

Purpose. To evaluate the feasibility and efficacy of a modified metallic coil embolization technique for pulmonary arteriovenous malformations (PAVMs) using coil anchors and occlusion balloon catheters. Methods. Five consecutive female patients with 6 PAVMs were included in the present study. One of the 6 PAVMs was of the complex type with four feeding arteries. An occlusion balloon catheter was inserted into the feeding artery as close to the venous sac as possible. The coil anchor, which was a simple W-shaped bent stainless steel wire with two markers at each end, was deployed prior to embolization to prevent the systemic migration of embolic materials. Then, metallic coils were deployed around the coil anchors under inflow stoppage using the inflated occlusion balloon catheter. In the complex-type PAVM, the main feeder was occluded by this technique and the other three small feeders were embolized with metallic coils only. Results. In all 5 cases, occlusion balloon catheters could be inserted into the feeding arteries just proximal to the venous sacs, coil anchors were easily deployed, and complete occlusion was achieved without any migration of metallic coils or paradoxical embolism during the procedure. Conclusions. The modified metallic coil embolization technique with coil anchors and occlusion balloon catheters was feasible and considered to be useful in preventing procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization Combined with Local Methotrexate and Systemic Methotrexate for Treatment of Cesarean Scar Pregnancy with Different Ultrasonographic Pattern

Purpose: This study was designed to compare the effectiveness of systemic methotrexate (MTX) with uterine artery embolization (UAE) combined with local MTX for the treatment of cesarean scar pregnancy (CSP) with different ultrasonographic pattern, and to indicate the preferable therapy in CSP patients. Methods: The results of 21 CSP cases were reviewed. All subjects were initially administrated with systemic MTX (50 mg/m{sup 2} body surface area). UAE combined with local MTX was added to the patients who had failed systemic MTX. The transvaginal ultrasonography data were retrospectively assessed, and two different ultrasonographic patterns were found: surface implantation and deep implantation of amniotic sac. The management and its effectiveness for patients with the two ultrasonographic patterns were studied retrospectively. Ultrasound scan and serum {beta}-hCG were monitored during follow-up. Data were analyzed with the Student's t test. Results: Nine patients were successfully treated with systemic MTX. The remaining 12 cases were successfully treated with additional UAE combined with local MTX. According to the classification by Vial et al. of CSP on ultrasonography, most surface implanted CSPs (8/11, 72.7%) could be successfully treated with systemic MTX, whereas most deeply implanted CSPs (9/10, 90%) had failed systemic MTX but still could be successfully treated with additional UAE combined with local MTX. All patients recovered without severe side effects. Most patients with a future desire for reproduction achieved subsequent pregnancy. Conclusions: For CSP patients suitable for nonsurgical treatment, UAE combined with local MTX would be the superior option compared with systemic MTX in the cases with deep implantation of amniotic sac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)

Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolisation of Proximal Type 1 Endoleaks Following Endovascular Aneurysm Sealing (EVAS) Using the Nellix Device: Technique and Outcomes

AimTo evaluate the technical success and mid-term outcomes following transcatheter embolisation of type 1a endoleak after Nellix endovascular aneurysm sealing (EVAS).Materials and MethodsSeven patients (5 men; mean age 83; range 79–90) underwent transcatheter embolisation between July 2013 and August 2014. The average time from EVAS to embolisation was 136 days (range 6–301) and from endoleak diagnosis to embolisation was 20 days (range 2–50). Embolisation was performed with coils and Onyx in six cases and Onyx only in one case. Technical success, imaging and clinical outcomes of embolisation were reviewed. Technical success was defined as elimination of the endoleak on completion angiography and first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up (average 8 months; range 103–471 days).ResultsAll cases were technically successful. One patient required a second endovascular procedure following Onyx reflux into the Nellix endograft and another patient required surgical closure of a brachial puncture site. All patients are endoleak free with stable sac size on the latest available follow-up imaging.ConclusionIf a type 1 endoleak occurs after EVAS, embolisation using Onyx with or without coils is feasible and effective with high technical success and freedom from endoleak recurrence at mid-term follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗