Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resilience Framework”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Deciphering supramolecular and polymer-like behavior in metallogels: real-time insights into temperature-modulated gelation and rapid self-assembly dynamics

Bis(pyridyl) urea-based gelators, namely L2 and its isomeric mixture ( L1 + L2 ), are known to self-assemble into 1D architectures capable of inducing supramolecular gelation. Coordination with metal ions such as Ag( I ), Cu( II ), and Fe( III ) introduces structural reinforcement, enabling the formation of distinct 3D networks governed by metal-specific coordination geometries. Here, we present a comprehensive investigation into the temperature-responsive behavior (20–60 °C) of L2 and L1 + L2 , both in the absence and presence of Ag( I ), Dy( III ), Fe( III ), Cu( II ), and Ho( III ), using real-time small-angle neutron scattering (SANS). To probe long-term structural evolution/kinetics of self-assembly, real-time small-angle X-ray scattering (SAXS) was employed on L2 + Ag gels, complemented by differential scanning calorimetry (DSC) to evaluate thermal transitions. Our results reveal strikingly divergent gelation behaviors: L2 forms a highly rigid, covalent polymer-like network, while L1 + L2 exhibits remarkable thermal adaptability. Upon metal coordination, the assemblies exhibit pronounced crystallinity and exceptional thermal stability, as evidenced by persistent Bragg reflections and invariant d-spacings. Intriguingly, L2 : Fe (2 : 1) and L1 : L2 : Fe (0.5 : 0.5 : 1) in acetonitrile-d 3 (ACN-d 3 ) deviate from this trend, forming thermally labile amorphous gels. These systems show a complete loss of crystalline order, reduced Porod exponents—indicative of collapsed or branched fiber morphologies—and prominent melting and glass transition events in DSC. Fitting SANS and SAXS data to the correlation length model unveiled insightful nanostructural features. While most systems displayed minimal temperature-induced variation in mesh size or surface morphology, L2 : Ag in dimethyl sulfoxide-d 6 (DMSO-d 6 )/D 2 O and L2 : Fe (1 : 1) in ACN-d 3 exhibited a rare combination of thermally stable correlation lengths and increasing high- q exponents—strongly suggesting progressive fiber densification or surface smoothing within a robust gel framework. These findings highlight the tunability and structural resilience of supramolecular gels through precise control of ligand architecture, metal coordination, and temperature, offering valuable design principles for functional soft materials.

Pajoubpong, Jinnipha [Univ. of Cincinnati, OH (Uni↗

Understanding Mixed Precision GEMM with MPGemmFI: Insights into Fault Resilience

Emerging deep learning workloads urgently need fast general matrix multiplication (GEMM). Thus, one of the critical features of machine-learning-specific accelerators such as NVIDIA Tensor Cores, AMD Matrix Cores, and Google TPUs is the support of mixed-precision enabled GEMM. For DNN models, lower-precision FP data formats and computation offer acceptable correctness but significant performance, area, and memory footprint improvement. While promising, the mixed-precision computation on error resilience remains unexplored. To this end, we develop a fault injection framework that systematically injects fault into the mixed-precision computation results. We investigate how the faults affect the accuracy of machine learning applications. Based on the characteristics of error resilience, we offer lightweight error detection and correction solutions that significantly improve the overall model accuracy by 75% if the models experience hardware faults. The solutions can be efficiently integrated into the accelerator's pipelines.

Fang, Bo↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Water Network Tool for Resilience (WNTR)

The Water Network Tool for Resilience (WNTR) is an open source Python package designed to simulate and analyze resilience of water distribution networks. The United States Environmental Protection Agency, in partnership with Sandia National Laboratories, developed WNTR to integrate critical aspects of resilience modeling for water distribution networks into a single software framework. The software includes capability to: • Generate water network models • Modify network structure and operations • Assign fragility and survival curves to network components • Model disruptive events such as power outages, earthquakes, fires, pipe breaks, and contamination incidents • Model response and repair strategies • Simulate hydraulics and water quality • Evaluate resilience using a wide range of metrics • Integrate dependency with other critical infrastructure and supply chains • Analyze results and generate graphics SAND2019-450 M

Villa, Daniel↗

BioSecure Digital Twin: Manufacturing Innovation and Cybersecurity Resilience

U.S. national security, prosperity, economy, and well-being require secure, flexible, and resilient Biopharmaceutical Manufacturing. The COVID-19 pandemic reaffirmed that the biomedical production value-chain is vulnerable to disruption and has been under attack from sophisticated nation-state adversaries. Current cyber defenses are inadequate, and the integrity of critical production systems and processes are inherently vulnerable to cyber-attacks, human error, and supply chain disruptions. The following chapter explores how a BioSecure Digital Twin will improve U.S. manufacturing resilience and preparedness to respond to these hazards by significantly improving monitoring, integrity, security, and agility of our manufacturing infrastructure and systems. The BioSecure Digital Twin combines a scalable manufacturing framework with a robust platform for monitoring and control to increase U.S. biopharma manufacturing resilience. Then, the chapter discusses some of the inherent vulnerabilities and challenges at the nexus of health and advanced manufacturing. Next, the chapter highlights that as the Pandemic evolves, we need agility and resilience to overcome significant obstacles. This section highlights an innovative application of Cyber Informed Engineering to developing and deploying a BioSecure Digital Twin to improve the resilience and security of the biopharma industrial supply chain and production processes. Finally, the chapter concludes with a process framework to complement the Digital Twin platform, called the Biopharma (Observe, Orient, Decide, Act) OODA Loop Framework (BOLF), a four-step approach to decision-making outputs from the Digital Twin. The BOLF will help end users leverage twin technology by distilling the available information, focusing the data on context, and rapidly making the best decision while remaining cognizant of changes that can be made as more data becomes available.

99 GENERAL AND MISCELLANEOUS↗

Optimization-Based Resiliency Verification in Microgrids via Maximal Adversarial Set Characterization

Critical energy infrastructures are increasingly relying on advanced sensing and control technologies for efficient and optimal utilization of flexible energy resources. Algorithmic procedures are needed to ensure that such systems are designed to be resilient to a wide range of cyber-physical adversarial events. This paper provides a robust optimization framework to quantify the largest adversarial perturbation that a system can accommodate without violating pre-specified resiliency metrics. We formulate the maximal adversarial set characterization as a bi-level optimization problem which is solved via Lagrangian relaxations.We illustrate the proposed algorithm on an islanded microgrid example: a modified IEEE 123-node feeder with distributed energy resources. Simulations are carried out to characterize the tolerable adversarial perturbations for varying levels of available flexibility (energy reserves).

Nazir, Mohammad Nawaf↗

Blockchain Smart Contract Reference Framework and Program Logic Architecture for Transactive Energy Systems

This paper proposes a reference framework for a transactive energy market based on blockchain. The framework was designed based on the engineering requirements of a distribution-scale market; including participant needs, expected market transactions, and the cybersecurity constructs required to support a fair, secure and efficient market operation. It leverages the existing blockchain primitives to provide clear value propositions to the transactive market, including identity management (access control), data security (integrity), resiliency (decentralization, scalability and performance). The validity of the proposed framework is demonstrated using a real-time 5-min double-auction market. The results highlight its benefits while providing strong validation of applicability to blockchain within transactive energy systems.

Gourisetti, Sri Nikhil Gupta↗

What Is the Best Use of Biomass? A Harmonized LCA-TEA Framework Quantifying Economic and Environmental Metrics for Bioenergy Pathways

Bioresource utilization is expected to play a pivotal role in complementing existing energy pathways and enhancing energy resilience. This study develops a harmonized life cycle assessment (LCA) and techno-economic analysis (TEA) framework to evaluate the greenhouse gas (GHG) reduction potential, minimum fuel selling price (MFSP), and marginal abatement cost (MAC) of bioenergy pathways. We analyze 19 pathways, including liquid biofuels (via catalytic fast pyrolysis, Fischer–Tropsch synthesis, and gasification), bioelectricity, and biomass-to-hydrogen, with and without carbon capture and storage (CCS). The GHG impacts are assessed using the GREET 2022 model, while U.S. Billion-Ton 2016 biomass availability projections are used to estimate scale-up potential. Additionally, we evaluate the influence of a low-carbon electricity grid on pathway performance. Our results show that CCS implementation reduces carbon intensities (CI) to net-negative values for several pathways, with MAC ranging from $\$$32 to $\$$600 per metric ton (MT) CO2e avoided. Bioelectricity pathways with CCS achieve the lowest MAC ($\$$32–$\$$68/tCO2e), while liquid biofuels and hydrogen pathways remain critical for hard-to-abate sectors like aviation and heavy industry. Pathways with net-positive electricity demand benefit from a low-carbon grid, whereas those co-producing electricity experience increased MAC under lower electricity grid CI scenarios. This open-source framework provides a robust tool for harmonized evaluation of bioenergy pathways, enabling policymakers and stakeholders to identify cost-effective strategies for biomass utilization and carbon abatement at scale. The findings underscore the importance of CCS, co-product credits, and feedstock availability in optimizing bioenergy deployment for a low-carbon economy.

09 BIOMASS FUELS↗

Drought adaptation index (DAI) based on BLUP as a selection approach for drought-resilient switchgrass germplasm

This study introduces a Drought Adaptation Index (DAI), derived from Best Linear Unbiased Prediction (BLUP), as a method to assess drought resilience in switchgrass (Panicum virgatum L.). A panel of 404 genotypes was evaluated under drought-stressed (CV) and well-watered (UC) conditions over four consecutive years (2019–2022). BLUP-estimated biomass yields were used to calculate the DAI, which enabled classification of genotypes into four adaptation groups: very well-adapted, well-adapted, adapted, and unadapted. The DAI was compared with conventional drought tolerance indices, including the Stress Susceptibility Index (SSI), Stress Tolerance Index (STI), Geometric Mean Productivity (GMP), and Yield Stability Index (YSI). Correlation analyses demonstrated strong agreement between DAI and these indices, supporting its validity and consistency. Biplot analyses using the Genotype plus Genotype-by-Environment Interaction (GGE) and Additive Main Effects and Multiplicative Interaction (AMMI) models revealed significant genotype-by-environment interactions (GEI) and identified J222.A, J463.A, and J295.A. A as high-performing genotypes, with J222.A exhibiting greater yield stability across treatments and years. Additionally, DAI isoline curves provided a graphical representation of differential genotype performance under drought and control conditions. These visualizations aided in distinguishing genotypes with stable and superior biomass yield across contrasting environments. Overall, the BLUP-based DAI is a robust and practical selection tool that improves the accuracy of identifying drought-resilient, high-yielding switchgrass genotypes. Its integration into breeding programs offers a comprehensive framework for improving biomass productivity and stress adaptation under variable climatic conditions. The application of DAI supports the development of climate-resilient cultivars and contributes to sustainable bioenergy and forage production systems.

BLUP↗

Dysfunctionality Hazard Curve: Risk-Based Tool to Support the Resilient Design of Systems Subjected to Multihazards

While resilience metrics have been proposed and studied given a functionality recovery curve, they have not emphasized enough on accounting for the uncertainties in the multihazard occurrences and intensities. Moreover, these resilience metrics are not risk-based (i.e., they do not express the system's resilience loss as a frequency of exceedance), leading to inconsistencies in system performance description when compared to performance-based engineering frameworks. A risk-based tool termed dysfunctionality hazard curve is proposed to assess the resilience of systems subjected to single hazards or multihazards with inter-event dependencies. Dysfunctionality hazard curve expresses system resilience performance as frequency of exceedance of time to full functionality. In doing so, it characterizes system recovery as a sequence of repair activities and also considers the uncertainties in the multihazard occurrences and intensities. Dysfunctionality hazard curve is demonstrated for a residential building susceptible to earthquake and hurricane hazards. Results indicate that Dysfunctionality hazard curve for earthquakes is greater than that for hurricane winds under single hazards. Under multihazards, considering inter-event dependencies during system recovery leads to larger dysfunctionality hazard curve than ignoring them. Finally, the concept of dysfunctionality hazard curve is also extended to a system-of-systems consisting of residential and commercial buildings.

42 ENGINEERING↗

Viable Economic Frameworks and Regulatory Barriers for Community Microgrids

Community microgrids – microgrids with more than one piece of customer- and utility-owned distribution equipment contained in the isolation boundary – are an option for providing resilience to meet targeted community and utility needs. Because multiple investors, including customers, are involved there is a lack of clarity around viable ownership models, roles and responsibilities, and compensation mechanisms. Together, these aspects describe an economic framework. To be viable, an economic framework not only needs to provide the possibility of all parties agreeing to the microgrid but also needs to meet regulatory guidelines. This report contains learnings from present-day community microgrid tariffs and programs, regulatory filings, and experiences shared within an interest group to highlight regulatory barriers to community microgrids and identify several viable economic frameworks for community microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Sizing of Resilience Solutions for the U.S. Army Reserve

Power or water outages in buildings threaten the ability of the military to support surrounding communities during natural disasters. Outages can last for days, weeks or months. Typical solutions include very expensive batteries and onsite generation that are sized based on historical power needs. The U.S. Army Reserve (USAR) has teamed up with the Pacific Northwest National Laboratory (PNNL) to develop a simulation framework that optimizes future power needs to reduce the cost of resilience solutions. The approach starts with the building. Power needs during an emergency event are simulated at the building end-use level, then loads are reduced through the selection of life cycle cost-effective building-level technology improvements. These new optimized loads are then fed into a microgrid sizing tool that dynamically constructs many different combinations of solar photovoltaic, battery storage, and generator resources to meet the load for hundreds of statistically generated outage scenarios. Six site assessments completed by USAR and PNNL in 2019 have resulted in a 1-14% reduction in overall investment when optimizing the buildings first before determining the generation requirements. This approach helps the Army secure critical missions and provide a 14 day-minimum supply of necessary energy and water in the most efficient manner.

buidlings, efficiency, resilience, FEDS, MCOR↗

Implementation and Demonstration of the Digital Twin Certification System Remote Operations Framework

Microreactors are one promising advanced-reactor concept being pursued by the nuclear industry. They are distinguished by a relatively low power output of 20 MWth or less. These microreactors are intended for deployment in applications where conventional small-capacity power solutions, such as diesel generators, are either economically unfeasible or logistically challenging. Such applications include providing electric power and/or heat for remote communities, mining sites, defense installations, and humanitarian and disaster-relief missions. An important feature for the successful deployment of microreactors is their capability to be operated remotely. This capability can significantly reduce staffing costs by eliminating the need for licensed operators to be physically present at each reactor site. Instead, operators can be centralized in a single remote operations center placed in an economically advantageous location, thereby optimizing resources by consolidating expertise and enhancing operational efficiency. However, the implementation of a remote operation system for nuclear reactors raises new concerns regarding the security, reliability, and resilience of such a system. One way in which remote operations can be supported in a manner that maintains system security, reliability, and resilience is through the use of digital twins in a novel framework designed to verify and validate sensor data and commands communicated between the remote operations center and reactor. This framework, known as the Digital Twin Certification System (DTCS), has previously been proposed as an operations architecture that can bring security and resiliency levels of remote nuclear-reactor operations to a level acceptable for commercial deployment. This paper moves the proposed DTCS architecture from concept to reality by presenting the implementation and testing of the system. The rationale and implementation of the DTCS using tools such as DeepLynx and Apache Airflow, is covered in-depth. This is followed by a demonstration of the DTCS by applying the implemented system architecture to the Single Primary Heat Extraction and Removal Emulator, a small-scale non-nuclear test bed that emulates thermal behavior of a microreactor. The demonstration includes both normal and abnormal operating scenarios to highlight how the DTCS can increase the security, reliability, and resilience of a remote operations system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation and Demonstration of the Digital Twin Certification System Remote Operations Framework

Microreactors are one promising advanced-reactor concept being pursued by the nuclear industry. They are distinguished by a relatively low power output of 20 MWth or less. These microreactors are intended for deployment in applications where conventional small-capacity power solutions, such as diesel generators, are either economically unfeasible or logistically challenging. Such applications include providing electric power and/or heat for remote communities, mining sites, defense installations, and humanitarian and disaster-relief missions. An important feature for the successful deployment of microreactors is their capability to be operated remotely. This capability can significantly reduce staffing costs by eliminating the need for licensed operators to be physically present at each reactor site. Instead, operators can be centralized in a single remote operations center placed in an economically advantageous location, thereby optimizing resources by consolidating expertise and enhancing operational efficiency. However, the implementation of a remote operation system for nuclear reactors raises new concerns regarding the security, reliability, and resilience of such a system. One way in which remote operations can be supported in a manner that maintains system security, reliability, and resilience is through the use of digital twins in a novel framework designed to verify and validate sensor data and commands communicated between the remote operations center and reactor. This framework, known as the Digital Twin Certification System (DTCS), has previously been proposed as an operations architecture that can bring security and resiliency levels of remote nuclear-reactor operations to a level acceptable for commercial deployment. This paper moves the proposed DTCS architecture from concept to reality by presenting the implementation and testing of the system. The rationale and implementation of the DTCS using tools such as DeepLynx and Apache Airflow, is covered in-depth. This is followed by a demonstration of the DTCS by applying the implemented system architecture to the Single Primary Heat Extraction and Removal Emulator, a small-scale non-nuclear test bed that emulates thermal behavior of a microreactor. The demonstration includes both normal and abnormal operating scenarios to highlight how the DTCS can increase the security, reliability, and resilience of a remote operations system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A Secure Learning Control Strategy via Dynamic Camouflaging for Unknown Dynamical Systems under Attacks

This paper presents a secure reinforcement learning (RL) based control method for unknown linear time-invariant cyber-physical systems (CPSs) that are subjected to compositional attacks such as eavesdropping and covert attack. We consider the attack scenario where the attacker learns about the dynamic model during the exploration phase of the learning conducted by the designer to learn a linear quadratic regulator (LQR), and thereafter, use such information to conduct a covert attack on the dynamic system, which we refer to as doubly learning-based control and attack (DLCA) framework. We propose a dynamic camouflaging based attack-resilient reinforcement learning (ARRL) algorithm which can learn the desired optimal controller for the dynamic system, and at the same time, can inject sufficient misinformation in the estimation of system dynamics by the attacker. The algorithm is accompanied by theoretical guarantees and extensive numerical experiments on a consensus multi-agent system and on a benchmark power grid model.

Mukherjee, Sayak↗

A Behavior Tree Approach for Battery-Aware Inspection of Large Structures Using Drones

Electric multi-rotor drones have been used to inspect several structures, including large buildings and dams. In these inspections, energy consumption is a concern. To prevent the drone from running out of battery, commercial drones usually come back to their home position when the battery level reaches a minimum threshold. The pilots then need to replace the battery and use their own experience to restart the inspection mission approximately from where it ended before the drone returned home. Instead of relying on the human operator, in this paper, we automate this process using behavior trees, which is an effective way to perform autonomous mission control and supervision. By integrating battery management strategies into a behavior tree framework, this paper demonstrates the drone’s adaptive and resilient decision-making when confronted with limited power constraints. We implemented our methodology using a commercial drone and tested the proposed ideas in a photogrammetry-based inspection task.

42 ENGINEERING↗

Integrating Cyber-Informed Engineering into Process Automation

As organizations increasingly automate their core missions and essential functions to address business risks and enhance efficiency, process automation becomes pivotal. This shift, involving minimal or no manual intervention, significantly impacts an organization's cyber-risk landscape. While automation drives efficiencies, it also introduces new cyber risks if not properly managed. Cyber-Informed Engineering (CIE) provides a proactive framework for managing these digital risks, enhancing cyber-resilience in process automation. This document supports organizations in applying CIE principles to mitigate the cyber risks associated with automation. The outlined approach can be independently implemented to improve any organization’s cyber-resilience, ensuring that the advantages of automation do not result in unaddressed or unmanaged digital risks. It serves as a starting point, offering considerations for integrating CIE principles and practices into organizational processes. CIE is presented as an iterative process, fostering continuous improvement and reinforcing the engineering and operational cultures to manage digital risks effectively. The document is structured as follows: Section 1 provides background on CIE and process automation, and their integration. Section 2 explores the twelve CIE principles in the context of process automation, highlighting key questions, engineering considerations, and implications for digital risk management. Section 3 synthesizes the findings and offers recommendations to advance resilience by design.

42 - ENGINEERING↗

Assessing Customer Experience and Business Models around Price-to-Device Communication and Smart Control Pathways in CalFlexHub

California is facing three major challenges in electrical grid operation: renewable overgeneration, steep evening ramping, and growing peak demand. The state has identified dynamic retail price response as a key strategy evidenced by CPUC’s Dynamic Rates proceeding and CEC’s Load Management Standards. Furthermore, the CEC launched a $16M “California Load Flexibility Research and Deployment Hub (CalFlexHub)” administered by Berkeley Lab to accelerate price-response flexible load technologies in buildings and EV charging. There are more than 16 laboratory and field demonstration projects in CalFlexHub, each demonstrating innovative automated price-response technologies. CalFlexHub tests various pathways through which hourly price signals and triggered control commands are communicated to load-flexible devices such as smart thermostats, heat pumps, water heaters, and EVs. We identified seven unique communication and control pathways, which involve combinations of third-party cloud, device OEM’s cloud, building central gateway, and local controller in between the price server and the load-flexible devices. It is important for utilities and policy makers to understand the long-term implications of each pathway in designing future programs and creating related policies and mandates for market transformation. We propose an evaluation framework including the following aspects: ● Functionality: connectivity and uptime, resilience, and optimization; ● Customer experience: simplicity in setup, troubleshooting support, continuity, customer choice, first cost, and ongoing cost; ● Business model and scalability: advance interoperability, holistic solution, bridge unique gap, customer base, and value streams and pricing structures. In this paper, we identify emerging business models associated with each communication pathway and discuss their positive features and challenges from the above aspects.

Liu, Jingjing↗