Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Path to Zero Energy Ready Home Construction

This paper will be presented at the 5th Residential Building Design & Construction Conference in State College, Pennsylvania. While the number of zero energy homes constructed in the U.S. has grown dramatically, increasing nearly 400% since 2015, zero energy homes still accounted for less than 1% of all U.S. homes constructed as of December 2018. Concerns about high costs or implementation challenges have kept many builders from attempting zero energy home construction. However, builders participating in the U.S. Department of Energy’s Zero Energy Ready Home Program are showing that zero energy ready home construction can be achieved simply and cost effectively with off-the-shelf equipment and materials and common construction techniques. Construction methods used by builders in the DOE program are compared with those used in just-to-code new homes and existing homes for several key components, including wall assemblies and HVAC systems. Examples of cost-effective assemblies used in the Mid Atlantic states are provided.

U.S. Department of Energy Building Technologies Pr↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

Design and analysis of optimal pre-cooling in residential buildings

Existing pre-cooling strategies provide a means of shifting or reducing the peak demand and/or energy cost in residential buildings. However, majority of them are rule-based and therefore may not be optimal in terms of cost saving, leaving room for improvement. In this paper, an integer linear programming problem that accounts for the thermal properties of a specific home, HVAC system capacity, utility rate structure, and weather conditions and makes use of a home thermal model is formulated. This problem determines the HVAC on/off control signal that minimizes the 24-h energy cost while maintaining thermal comfort and calculates the corresponding optimal indoor air temperature. The model is constructed using home thermal properties identified via data training in real-time. Through simulation, the energy performance of the proposed optimal pre-cooling strategy is investigated and compared with three rule-based operation strategies from the literature. It is found that the optimal strategy requires the least energy consumption without sacrificing thermal comfort. The superb energy performance of the optimal strategy is attributed to a longer runtime of the HVAC system in cool outdoor air conditions and to the elimination of deadband in HVAC operation, which is required by the rule-based strategies, to allow the indoor air temperature to stay near the thermal comfort upper bound as much as possible. In terms of energy cost, the rule-based operation strategies require 3.52, 1.90, and 2.79, respectively, while the optimal strategy only requires 1.52. These figures represent a saving of 56.82%, 20.00%, and 45.52%, respectively. The results suggest that the optimal strategy is indeed significantly more effective than the existing rule-based operation strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

15 GEOTHERMAL ENERGY↗

Strategic Energy Plan: City of Key West, Florida

This Strategic Energy Plan for the city of Key West, Florida—developed through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project (ETIPP)—outlines a comprehensive strategy to advance the city’s energy vision: to improve energy efficiency and independence using local energy resources to foster long-term resilience. To guide this effort, the plan is structured around four focus areas: • Energy efficiency: Reduce overall energy consumption and utility costs across municipal, residential, and commercial buildings. • Local energy generation: Increase the share of energy produced from local sources to enhance energy independence. • Resilience: Strengthen critical infrastructure and community preparedness for flooding, hurricanes, and other natural weather hazards. • Electric transportation: Support the addition of new electric vehicles (EVs) and develop reliable charging infrastructure to reduce reliance on imported fuels. ETIPP provides strategic energy planning, technical assistance, and direct funding to U.S. coastal, remote, and island communities to improve energy resilience. Key West was part of ETIPP’s fourth cohort. As a low-lying island community vulnerable to infrastructure damage due to natural weather hazards, Key West seeks to reduce its dependence on external energy and build long-term sustainability. The Strategic Energy Plan identifies specific challenges, sets clear goals, and proposes actionable opportunities with implementation timelines and key stakeholders. A baseline assessment reveals significant energy consumption in both city-owned and residential/commercial buildings, limited local energy generation, and an early-stage EV market with vulnerable charging infrastructure. The proposed solutions emphasize a multifaceted approach, leveraging both established and innovative technologies, while addressing financial, technical, and community engagement challenges. The baseline assessment provided a snapshot of current energy conditions in Key West, evidencing key challenges and opportunities across the city’s energy priorities. Building on the baseline assessment and extensive input from city staff, local stakeholders, and community partners, a set of targeted opportunities was identified to address Key West’s energy goals. Each was evaluated in terms of its potential benefits, key implementation steps, associated challenges and mitigation strategies, and the city departments and stakeholders best positioned to lead or support progress.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

ComStock™ 2024 Release 1 [SWR-19-33 and SWR-20-32]

ComStock™ is an NREL model of the U.S. commercial building stock. The model takes some building characteristics from the U.S. Department of Energy's (DOE's) Commercial Prototype Building Models and Commercial Reference Building. However, unlike many other building stock models, ComStock also combines these with a variety of additional public- and private-sector data sets. Collectively, this information provides high-fidelity building stock representation with a realistic diversity of building characteristics. This repository contains the source code used to build and execute ComStock models, including upgrade scenarios. In addition, the sampling of buildings characteristics used for the initial ComStock (V1.0) release is provided. The ComStock model is under active calibration and development, which is publicly visible on this repository. Execution of the ComStock workflow is managed through the buildstockbatch repository, a shared asset of ResStock™ and ComStock™ , specifically developed to scale to execution of tens of millions of simulations through multiple infrastructure providers. The dataset output from the initial ComStock (V1.0) release can be found at the accompanying ComStock data viewer website and additional information about ComStock found on the NREL Buildings Website. For more details about ongoing model development please consult the End Use Load Profiles website. ComStock is a direct result of the NREL residential stock modeling tool ResStock™ (recipient of a R&D100 award) and was inspired by the high-fidelity solar & storage adoption model dGen™. Additionally, this tool would not be possible without the decades of work undertaken by the OpenStudio® and EnergyPlus® visionaries and contributors, significant funding, feedback and support from the Los Angeles Department of Water and Power, and the Department of Energy's Building Technology Office ongoing support of and investment in building energy modeling software. is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.

Horsey, Henry↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What to expect when you're expecting engagement: Delivering procedural justice in large-scale solar energy deployment

Community engagement in the planning process to build large-scale solar (LSS) projects can win local support and advance procedural justice. However, an understanding of community engagement in current LSS development is lacking. Using responses from a U.S. nationwide survey (n = 979) of residential neighbors living within 3 miles (4.8 km) of completed LSS projects (i.e. “solar neighbors”) and project details from the U.S. Large-Scale Solar Photovoltaic Database (USPVDB), this study seeks to answer the following questions: How are solar neighbors' perceptions of community engagement associated with their attitudes toward their LSS projects? How do solar neighbors' perceptions of community engagement compare to their expectations? And, how do neighbors explain what they perceived about the planning process? We answer these questions using mixed methods, including regression modeling, a new gap analysis technique, and qualitative coding. We find that higher perceived engagement is associated with more positive attitudes toward the project, even when controlling for respondents who acted in opposition. Supporters and opponents alike expect more engagement than they perceived and information about projects both before construction and after operation is lacking. Awareness and engagement expectations increase at certain project size and proximity thresholds. However, most neighbors expect the public to offer input during engagement, but not make decisions. We contextualize these findings with explanatory comments from respondents.

14 SOLAR ENERGY↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗