At least 217 records · Page 12

Layered topological semimetal GaGeTe: New polytype with non-centrosymmetric structure

GaGeTe is a layered van der Waals material composed of germanene and GaTe sublayers that has been recently predicted to be a basic Z 2 topological semimetal. To date, only one polytype of GaGeTe is known with trigonal centrosymmetric structure (α phase, space group R-3m, No. 166). Here we show that as-grown samples of GaGeTe show traces of at least another polytype with hexagonal non-centrosymmetric structure (β phase, space group P6 3 mc, No. 186). Moreover, we suggest that another bulk hexagonal polytype (γ phase, space group P-3m1, No. 164) could also be found near room conditions. Both α and β polytypes have been identified and characterized by means of X-ray diffraction and Raman scattering measurements with the support of ab initio calculations. We provide the vibrational properties of both polytypes and show that the Raman spectrum reported for GaGeTe almost forty years ago and attributed to the α phase, was, in fact, that of the secondary β phase. Additionally, we show that a Fermi resonance occurs in α-GaGeTe under non-resonant excitation conditions, but not under resonant excitation conditions. Theoretical calculations show that bulk β-GaGeTe is a non-centrosymmetric weak topological semimetal with even smaller lattice thermal conductivity than centrosymmetric bulk α-GaGeTe. In perspective, our work paves the way for the control and engineering of GaGeTe polytypes to design and implement complex van der Waals heterostructures formed by a combination of centrosymmetric and non-centrosymmetric layers of up to three different polytypes in a single material, suitable for a number of fundamental studies and technological applications.

36 MATERIALS SCIENCE↗

Accurate in vivo tumor detection using plasmonic-enhanced shifted-excitation Raman difference spectroscopy (SERDS)

For the majority of cancer patients, surgery is the primary method of treatment. In these cases, accurately removing the entire tumor without harming surrounding tissue is critical; however, due to the lack of intraoperative imaging techniques, surgeons rely on visual and physical inspection to identify tumors. Surface-enhanced Raman scattering (SERS) is emerging as a non-invasive optical alternative for intraoperative tumor identification, with high accuracy and stability. However, Raman detection requires dark rooms to work, which is not consistent with surgical settings. Methods: Herein, we used SERS nanoprobes combined with shifted-excitation Raman difference spectroscopy (SERDS) detection, to accurately detect tumors in xenograft murine model. Results: We demonstrate for the first time the use of SERDS for in vivo tumor detection in a murine model under ambient light conditions. We compare traditional Raman detection with SERDS, showing that our method can improve sensitivity and accuracy for this task. Conclusion: Our results show that this method can be used to improve the accuracy and robustness of in vivo Raman/SERS biomedical application, aiding the process of clinical translation of these technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visible Out-of-plane Polarized Luminescence and Electronic Resonance in Black Phosphorus

Black phosphorus (BP) is unique among layered materials because of its homonuclear lattice and strong structural anisotropy. While recent investigations on few-layer BP have extensively explored the in-plane (a, c) anisotropy, much less attention has been given to the out-of-plane direction (b). Here, the optical response from bulk BP is probed using polarization-resolved photoluminescence (PL), photoluminescence excitation (PLE), and resonant Raman scattering along the zigzag, out-of-plane, and armchair directions. An unexpected b-polarized luminescence emission is detected in the visible, far above the fundamental gap. PLE indicates that this emission is generated through b-polarized excitation at 2.3 eV. The same electronic resonance is observed in resonant Raman with the enhancement of the A g phonon modes scattering efficiency. These experimental results are fully consistent with DFT calculations of the permittivity tensor elements and demonstrate the remarkable extent to which the anisotropy influences the optical properties and carrier dynamics in black phosphorus.

36 MATERIALS SCIENCE↗

Anharmonic Exciton‐Phonon Coupling in Metal‐Organic Chalcogenides Hybrid Quantum Wells

Abstract In contrast to inorganic quantum wells, hybrid quantum wells (HQWs) based on metal‐organic semiconductors are characterized by relatively soft lattices, in which excitonic states can strongly couple to lattice phonons. Therefore, understanding the lattice's impact on exciton dynamics is essential for harnessing the optoelectronic potential of HQWs. Beyond 2D metal halide perovskites, layered metal‐organic chalcogenides (MOCs), which are an air‐stable, underexplored material class hosting room‐temperature excitons, can be exploited as photodetectors, light emitting devices, and ultrafast photoswitches. Here, the role of phonons in the optical transitions of the prototypical MOC [AgSePh] ∞ is elucidated. Impulsive stimulated Raman scattering (ISRS) allows the detection of coherent exciton oscillations driven by Fröhlich interaction with low‐energy optical phonons. Steady state absorption and Raman spectroscopies reveal a strong exciton‐phonon coupling (Huang‐Rhys parameter ≈1.7) and its anharmonicity, manifested as a nontrivial temperature‐dependent Stokes shift. The ab initio calculations support these observations, hinting at an anharmonic behavior of the low‐energy phonons <200 cm −1 . These results untangle complex exciton‐phonon interactions in MOCs, establishing an ideal testbed for room‐temperature many‐body phenomena.

36 MATERIALS SCIENCE↗

BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a powerful label-free biological imaging technique, but the raw signal requires careful processing. The vibrationally resonant (Raman) fingerprint signal is usually small compared with instrumental noise sources and the nonresonant background (NRB) inherent in the BCARS signal. Fortunately, the NRB exhibits a systematic phase relationship with the coherent Raman response, acting as a heterodyne amplifier for the weak fingerprint signal. Due to this heterodyne effect, the Raman response can be recovered quantitatively and invariantly across different instruments, provided the NRB shape is known. Even with heterodyne amplification, the amplitudes of fingerprint signal components are often comparable to system noise. Singular value decomposition (SVD), which utilizes spatial information, is often employed for additional noise filtering. Consequently, finding optimal processing parameters to properly distinguish the NRB and Raman responses and suppress noise in the complex BCARS signal requires a reference system that realistically represents the spectral and spatial properties of BCARS signals obtained from biological samples. We present a digital tissue phantom that meets these criteria as a tool for testing candidate signal processing pipelines. The digital phantom is generated with simulated hyperspectral Raman images having system-specific noise and background characteristics. Here, we analyze phantom datasets with differing background and signal-to-noise conditions to evaluate their impact on the performance of multiple signal processing pipelines. Specifically, we investigate the application of a Butterworth filter-based routine to directly estimate the NRB from the BCARS signal. Additionally, we evaluate a Lorentzian wavelet transform as an alternative to the Hilbert transform for extracting the Raman spectrum from the BCARS signal. While we demonstrate this phantom for BCARS, it can be used for any spectroscopic Raman imaging approach.

Dixon, Jessica Z. [Georgia Institute of Technology↗

A first principles method to determine speciation of carbonates in supercritical water

The determination of the speciation of ions and molecules in supercritical aqueous fluids under pressure is critical to understanding their mass transport in the Earth's interior. Unfortunately, there is no experimental technique yet available to directly characterize species dissolved in water at extreme conditions. Here we present a strategy, based on first-principles simulations, to determine ratios of Raman scattering cross-sections of aqueous species under extreme conditions, thus providing a key quantity that can be used, in conjunction with Raman measurements, to predict chemical speciation in aqueous fluids. Due to the importance of the Earth's carbon cycle, we focus on carbonate and bicarbonate ions. Our calculations up to 11 GPa and 1000 K indicate a higher concentration of bicarbonates in water than previously considered at conditions relevant to the Earth's upper mantle, with important implications for the transport of carbon in aqueous fluids in the Earth's interior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Origin of Large Effective Phonon Magnetic Moments in Monolayer MoS 2

Recent helicity-resolved magneto-Raman spectroscopy measurement demonstrates large effective phonon magnetic moments of ~2.5 μ B in monolayer MoS 2 , highlighting resonant excitation of bright excitons as a feasible route to activate Γ-point circularly polarized phonons in transition metal dichalcogenides. However, a microscopic picture of this intriguing phenomenon remains lacking. In this work, we show that an orbital transition between the split conduction bands (Δ 0 = 4 meV) of MoS 2 couples to the doubly degenerate E" phonon mode (Ω 0 = 33 meV), forming two hybridized states. Our phononic and electronic Raman scattering measurements capture these two states: (i) one with predominantly phonon contribution in the helicity-switched channels and (ii) one with primarily orbital contribution in the helicity-conserved channels. An orbital-phonon coupling model successfully reproduces the large effective magnetic moments of the circularly polarized phonons and explains their thermodynamic properties. Strikingly, the Raman mode from the orbital transition is superimposed on a strong quasi-elastic scattering background, indicating the presence of spin fluctuations. As a result, the electrons excited to the conduction bands through the exciton exhibit paramagnetic behavior although MoS 2 is generally considered as a nonmagnetic material. By depositing nanometer-thickness nickel thin films on monolayer MoS 2 , we tune the electronic structure so that the A exciton perfectly overlaps with the 633 nm laser. The optimization of resonance excitation leads to pronounced tunability of the orbital-phonon hybridized states. Our results generalize the orbital-phonon coupling model of effective phonon magnetic moments to material systems beyond the paramagnets and magnets.

2D transition metal dichalcogenide↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of the mode Grüneisen parameters with anisotropic compression: A pressure and temperature dependent Raman study of β-Sn

The lattice dynamic response of body-centered tetragonal beta-Sn (I4 1 /amd) under high-pressure and temperature conditions is determined using experimental optical vibration modes. Here, Raman scattering is used to map the phase stability region of beta-Sn to perform mode Gruneisen analysis, and we demonstrate the necessity of an optical intensity calibration for Raman thermometry. The Gruneisen tensor is evaluated along a set of isotherms to address shortcomings of single-mode Gruneisen parameters with respect to anisotropic deformations of this tetragonal structured soft metal. The changes observed here in the Gruneisen tensor as a function of temperature are related to anharmonicity and denote potential criteria for the onset of premelting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonant Raman in armchair graphene nanoribbons from first-principles

Resonant Raman spectra of armchair graphene nanoribbons (AGNRs) are computed using Density Functional Theory (DFT) and third-order perturbation theory. Results are benchmarked against available experimental data and compared to previously used theoretical approaches based on the Placzek approximation. Comparable agreement with experiments is found for both previously and presently used methods. In addition, a numerical analysis is carried out to provide a justification for the resonant modeling method based on the use of the frequency-dependent dielectric tensor in the Placzek approximation. Finally, this work also provides additional predictions and references for wide AGNRs that might be investigated with Raman scattering experiments in the future.

42 ENGINEERING↗

Resonant four-photon scattering of collinear laser pulses in plasma

Exact four-photon resonance of collinear planar laser pulses is known to be prohibited by the classical dispersion law of electromagnetic waves in plasma. We show here that the renormalization produced by an arbitrarily small relativistic electron nonlinearity removes this prohibition. The laser frequency shifts in collinear resonant four-photon scattering increase with laser intensities. For laser pulses of frequencies much greater than the electron plasma frequency, the shifts can also be much greater than the plasma frequency and even nearly double the input laser frequency at still small relativistic electron nonlinearities. Furthermore, this may enable broad range tunable lasers of very high frequencies and powers. Since the four-photon scattering does not rely on the Langmuir wave, which is very sensitive to plasma homogeneity, such lasers would also be able to operate at much larger plasma inhomogeneities than lasers based on stimulated Raman scattering in plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microsecond fingerprint stimulated Raman spectroscopic imaging by ultrafast tuning and spatial-spectral learning

Label-free vibrational imaging by stimulated Raman scattering (SRS) provides unprecedented insight into real-time chemical distributions. Specifically, SRS in the fingerprint region (400–1800 cm -1 ) can resolve multiple chemicals in a complex bio-environment. However, due to the intrinsic weak Raman cross-sections and the lack of ultrafast spectral acquisition schemes with high spectral fidelity, SRS in the fingerprint region is not viable for studying living cells or large-scale tissue samples. Here, we report a fingerprint spectroscopic SRS platform that acquires a distortion-free SRS spectrum at 10 cm -1 spectral resolution within 20 µs using a polygon scanner. Meanwhile, we significantly improve the signal-to-noise ratio by employing a spatial-spectral residual learning network, reaching a level comparable to that with 100 times integration. Collectively, our system enables high-speed vibrational spectroscopic imaging of multiple biomolecules in samples ranging from a single live microbe to a tissue slice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Footprints of Kitaev spin liquid in the Fano lineshape of Raman-active optical phonons

We develop a theoretical description of the Raman spectroscopy in the spin-phonon-coupled Kitaev system and show that it can provide observable signatures of fractionalized excitations characteristic of the underlying spin-liquid phase. In particular, we obtain the explicit form of the phonon modes and construct the coupling Hamiltonian based on the D 3d symmetry. We then systematically compute the Raman intensity and show that the spin-phonon coupling renormalizes phonon propagators and generates the salient Fano lineshape. We find that the temperature evolution of the Fano lineshape displays two crossovers, and the low-temperature crossover shows pronounced magnetic-field dependence. We thus identify the observable effect of the Majorana fermions and the Z2 gauge fluxes encoded in the Fano lineshape. Our results are consistent with the phonon Raman scattering experiments in the candidate material α-RuCl 3 .

36 MATERIALS SCIENCE↗

Large Propagation-Direction-Dependent Circularly Polarized Emission and Scattering Anisotropies of a Chiral Organic-Inorganic Semiconductor

Chiral materials are important tools for transducing circularly polarized light within many emerging opto-electronic and spin-based technologies. Here, we demonstrate that thin films of a bismuth iodide-based 0D chiral hybrid organic-inorganic semiconductor (HOIS) exhibit large anisotropy values in circularly polarized light emission (CPLE) that approach 50%, with mirror-image responses from front- and back-side measurements. A comprehensive analysis of light-wave propagation, absorption, emission, and scattering is constructed on the basis of a symmetry-derived exciton fine structure model, which accurately describes the direction and polarization dependence of the observed excitonic circular dichroism and CPLE, including contributions from both photoluminescence and resonant Raman scattering. Our analysis indicates that molecular chirality drives preferential film alignment with respect to the out-of-plane lattice vector direction, producing the observed anisotropies. This first demonstration in an HOIS system provides a unique route for enhancing polarization-dependent emission, and circularly polarized light transduction more broadly, in self-assembled HOIS.

14 SOLAR ENERGY↗

Spin and orbital excitations through the metal-to-insulator transition in Cd 2 Os 2 O 7 probed with high-resolution resonant inelastic x-ray scattering

Here, high-resolution resonant inelastic x-ray scattering measurements (ΔE=46meV) have been performed on Cd 2 Os 2 O 7 through the metal-to-insulator transition (MIT). A magnetic excitation at 125 meV evolves continuously through the MIT, in agreement with recent Raman-scattering results, and provides further confirmation for an all-in all-out magnetic ground state. Asymmetry of this feature is likely a result of coupling between the electronic and the magnetic degrees of freedom. We also observe a broad continuum of interband excitations centered at 0.3 eV energy loss. This is indicative of significant hybridization between Os 5d and O 2p states and the concurrent itinerant nature of the system. In turn, this suggests a possible breakdown of the free-ion model for Cd 2 Os 2 O 7 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vacancies and spin-phonon coupling in CrSi 0.8 Ge 0.1 Te 3

We report temperature-dependent Raman scattering and magnetization studies of van der Waals ferromagnetic compound CrSi 0.8 Ge 0.1 Te 3 . Magnetic susceptibility measurements revealed dominant ferromagnetic interactions below T C which shift to the lower values due to the presence of vacancies. A Raman active mode, additional to the ones predicted by symmetry in the parent compounds, has been observed. This A g symmetry mode most likely emerges as a consequence of the atomic vacancies on Si/Ge site. Presence of the strong spin–phonon coupling at temperature around 210 K is indicated by deviations from conventional phonon self-energy temperature dependence of all analysed modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of picosecond coherent anti-Stokes Raman spectra for gas-phase diagnostics

We present a hybrid frequency- and time-domain solution, applicable to the case of picosecond coherent anti-Stokes Raman scattering (CARS), for gas-phase diagnostics. A solution has been derived based on both physical arguments and four-wave mixing equations for picosecond CARS, with pulse durations that are comparable to the dephasing time scale for gas-phase Raman coherence—a regime where commonly employed solutions for impulsive (femtosecond) or cw (nanosecond) pump/Stokes forcing are not strictly valid. We present the ps-CARS spectrum in the form of incoherent sums of CARS intensity spectra, calculated from the fundamental solution for impulsive pump/Stokes Raman preparation. The solution was examined for temperatures from 1000–3000 K, for four plausible experimental configurations, with laser pulse durations of 50–150 ps, and probe pulse delays from −20 to 240 ps. Approximations based on cw and impulsive pump/Stokes preparation to fit picosecond CARS spectra at atmospheric pressure were examined and the relative thermometric accuracy and computational cost of these approximations were quantified for the case of a zero nonresonant CARS contribution, and a nonresonant susceptibility equal to 10% of the Raman-resonant value at the N 2 bandhead. The nanosecond CARS approximation can result in large fitting errors when the probe pulse time delay is less than the probe pulse duration. Errors as large as 10–20% are observed in the fit temperatures for a zero picosecond probe pulse delay, when the nonresonant background is neglected, largely due to an inability of the time-independent cw model to capture transient frequency spread dephasing effects at the Q -branch bandhead. The inclusion of a nonresonant background results in 40–60% thermometry errors with a nanosecond model at a zero-probe delay. Time-dependent impulsive calculations used for femtosecond CARS better approximate the structure of the N 2 bandhead, reducing temperature fitting errors to 5–10% at a short probe pulse delay. The impulsive approximation results in errors up to 10% at intermediate probe pulse delays, where the coherence of the pump and probe pulses leads to multiple terms in the picosecond CARS solution. Both approximations improve as the probe pulse delay exceeds the probe duration. The nanosecond approximation results in a 2–3% error, while the impulsive model results in differences of less than 1% in some cases. Fits to experimental data obtained using short, ∼60ps pulses at a zero probe time delay and longer 100 ps pulses at a substantial 200 ps delay are presented with accuracies of 1–3% in the fit temperature.

Kearney, Sean P.↗