Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This work seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the biosensors. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as exposure to radiation. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), and reporting agents. The reporting will be accomplished through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation. These nanosensors could facilitate the success and increase the safety of extended space flight. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. This period, synthesis of the test-bed biosensors continued. Studies were performed on the candidate fluorescent dyes to determine which might be suitable for the biosensor under development. Development continued on producing an artificial capillary bed as a tool for the use in the production of the fluorescence signal monitor. Work was also done on the in vitro multispectral analysis system, which uses the robotic microscope.

Baker, James R.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This proposal seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the sensor/actuators. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as the exposure to radiation or infectious agents. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), magnetic particles and metals, and imaging agents. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. These molecules would also be able to administer therapeutics in response to the needs of the astronaut, and act as actuators to remotely manipulate an astronaut as necessary to ensure their safety. The reporting will be accomplished either through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation, or through functional MRI. These nanosensors coupled to NEMS devices could facilitate the success and increase the safety of extended space flight.

Baker, James R., Jr.↗

RadWorks Project. ISS REM - to - BIRD - to - HERA: The Evolution of a Technology

The advancement of particle detectors based on technologies developed for use in high-energy physics applications has enabled the development of a completely new generation of compact low-power active dosimeters and area monitors for use in space radiation environments. One such device, the TimePix, is being developed at CERN, and is providing the technology basis for the most recent line of radiation detection devices being developed by the NASA AES RadWorks project. The most fundamental of these devices, an ISS-Radiation Environment Monitor (REM), is installed as a USB device on ISS where it is monitoring the radiation environment on a perpetual basis. The second generation of this TimePix technology, the BIRD (Battery-operated Independent Radiation Detector), was flown on the NASA EFT-1 flight in December 2014. Data collected by BIRD was the first data made available from the Trapped Belt region of the Earth's atmosphere in over 40 years. The 3rdgeneration of this technology, the HERA (Hybrid Electronic Radiation Assessor), is planned to be integrated into the Orion EM-1, and EM-2 vehicles where it will monitor the radiation environment. For the EM-2 flight, HERA will provide Caution and Warning notification for SPEs as well as real time dose measurements for crew members. The development of this line of radiation detectors provide much greater information and characterization of charged particles in the space radiation environment than has been collected in the past, and in the process provide greater information to inform crew members of radiation related risks, while being very power and mass efficient.

McLeod, Catherine D.↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

X-ray based displacement and strain measurements for hostile environments

A completely new method of non-contacting, hostile environment displacement and strain measurement based on the focus and scanning of x-rays, has been developed and demonstrated. The new technique has the ability to overcome many of the limitations associated with available methods. The system is based on the focus and scanning of low energy, hard x-rays such as those emanating from table top copper or molybdenum sources. The x-rays are focused into a narrow and intense line image which can be swept onto targets that fluoresce secondary x-ray radiation. By monitoring the secondary radiation intensity and comparing it with the focused x-ray image's position as it is swept over the target edge, the position of the target edge relative to the focused image can be determined. The present system has a resolution of 0.5 micron, which has been shown to be limited by bearing backlash (or 'yaw' error) in the linear translation table. Its use has been demonstrated in the presence of an open flame with a resultant target temperature in excess of 2000 degrees Fahrenheit (1000 degrees Celsius). Strain measurements have been conducted in a laboratory environment at both room temperature and at a specimen temperature of 1300 degrees Fahrenheit, with an accuracy of within 20 microstrain (primarily a function of the 0.5 micron resolution limit). The main advantage of the technique lies in the penetrating, non-refractive nature of x-rays, which are virtually immune to the presence of refracting gas layers, smoke, flame or intense thermal radiation.

Canistraro, Howard A.↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Sensors for Monitoring Gamma and Neutron Radiation

For safety and efficiency, nuclear reactors must be carefully monitored to provide feedback that enables the fission rate to be held at a constant target level via adjustments in the position of neutron-absorbing rods and moderating coolant flow rates. For automated reactor control, the monitoring system should provide calibrated analog or digital output. The sensors must survive and produce reliable output with minimal drift for at least one to two years, for replacement only during refueling. Small sensor size is preferred to enable more sensors to be placed in the core for more detailed characterization of the local fission rate and fuel consumption, since local deviations from the norm tend to amplify themselves. Currently, reactors are monitored by local power range meters (LPRMs) based on the neutron flux or gamma thermometers based on the gamma flux. LPRMs tend to be bulky, while gamma thermometers are subject to unwanted drift. Both electronic reactor sensors are plagued by electrical noise induced by ionizing radiation near the reactor core. A fiber optic sensor system was developed that is capable of tracking thermal neutron fluence and gamma flux in order to monitor nuclear reactor fission rates. The system provides near-real-time feedback from small- profile probes that are not sensitive to electromagnetic noise. The key novel feature is the practical design of fiber optic radiation sensors. The use of an actinoid element to monitor neutron flux in fiber optic EFPI (extrinsic Fabry-Perot interferometric) sensors is a new use of material. The materials and structure used in the sensor construction can be adjusted to result in a sensor that is sensitive to just thermal, gamma, or neutron stimulus, or any combination of the three. The tested design showed low sensitivity to thermal and gamma stimuli and high sensitivity to neutrons, with a fast response time.

Boyd, Clark D.↗

Crystal Growth, Optical and Scintillation Properties of Eu 2+ -doped TlSr 2 Br 5

Crystals of undoped and Eu 2+ -doped TlSr 2 Br 5 of up to 16 mm in diameter and 50 mm in length were grown by the Vertical Bridgman technique. TlSr 2 Br 5 has the monoclinic crystal structure with space group P21/c. Its density and Z eff are 5.03 g/cm 3 and 58.6, respectively. Radioluminescence spectra of undoped and Eu 2+ -doped TlSr 2 Br 5 feature a broad emission band peaking at about 440 nm for undoped and 520 nm for Eu 2+ -doped crystals. The light yield of undoped TlSr 2 Br 5 is 42,000 ph/MeV, which increases to 55,000 ph/MeV for Eu 2+ -doped crystals. The energy resolution at 662 keV ( 137 Cs) is about 5 – 6% (FWHM). As a result, the scintillation decay of undoped and Eu 2+ -doped TlSr 2 Br 5 is of the order of 100s of nanoseconds.

Bridgman technique↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

Biodosimetry of ionizing radiation by selective painting of prematurely condensed chromosomes in human lymphocytes

Painting of interphase chromosomes can be useful for biodosimetric purposes in particular cases such as radiation therapy, accidental exposure to very high radiation doses and exposure to densely ionizing radiation, for example during space missions. Biodosimetry of charged-particle radiation is analyzed in the present paper. Target cells were human peripheral blood lymphocytes irradiated in vitro with gamma rays, protons and iron ions. After exposure, lymphocytes were incubated for different times to allow repair of radiation-induced damage and then fused to mitotic hamster cells to promote premature condensation in the interphase chromosomes. Chromosome spreads were then hybridized with whole-chromosome DNA probes labeled with fluorescent stains. Dose-response curves for the induction of chromatin fragments shortly after exposure, as well as the kinetics of rejoining and misrejoining, were not markedly dependent on linear energy transfer. However, after exposure to heavy ions, more aberrations were scored in the interphase cells after incubation for repair than in metaphase samples harvested at the first postirradiation mitosis. On the other hand, no significant differences were observed in the two samples after exposure to sparsely ionizing radiation. These results suggest that interphase chromosome painting can be a useful tool for biodosimetry of particle radiation.

NASA Center JSC↗

Survey of current situation in radiation belt modeling

The study of Earth's radiation belts is one of the oldest subjects in space physics. Despite the tremendous progress made in the last four decades, we still lack a complete understanding of the radiation belts in terms of their configurations, dynamics, and detailed physical accounts of their sources and sinks. The static nature of early empirical trapped radiation models, for examples, the NASA AP-8 and AE-8 models, renders those models inappropriate for predicting short-term radiation belt behaviors associated with geomagnetic storms and substorms. Due to incomplete data coverage, these models are also inaccurate at low altitudes (e.g., <1000 km) where many robotic and human space flights occur. The availability of radiation data from modern space missions and advancement in physical modeling and data management techniques have now allowed the development of new empirical and physical radiation belt models. In this paper, we will review the status of modern radiation belt modeling. Published by Elsevier Ltd on behalf of COSPAR.

Protons↗

Crystal growth, scintillation properties & fast neutron-gamma discrimination of cubic halide perovskite CsCaCl 3 :(Eu 2+ , Tl + )

The vast variety of nuclear security applications require radiation detection materials tailored to their operational needs. A scintillator’s properties are strongly influenced by the choice of luminescent dopant, which facilitates customization to different applications. In this work, transparent Ø12 mm single crystals of undoped CsCaCl 3 , CsCaCl 3 :1% Eu, CsCaCl 3 :1% Tl, and CsCaCl 3 :1% Eu, 1% Tl were grown via the Vertical Bridgman method. Their scintillation properties and fast neutron-gamma discrimination capabilities were investigated. Undoped CsCaCl 3 had a light yield of 2,500 ph/MeV, which is the highest reported to date for this CVL material. The incorporation of Eu 2+ or Tl + into CsCaCl 3 as luminescence centers resulted in significantly higher light yields of ∼16,000 ph/MeV and energy resolutions of ∼8% at 662 keV. Compared to the single dopant counterparts, CsCaCl 3 :Eu, Tl had significantly suppressed afterglow; however, this came at the cost of reduced light yield. Among the materials tested, only CsCaCl 3 :Tl showed effective fast neutron and gamma discrimination capabilities, achieving a Figure of Merit of 3.2 between gamma-rays and fast neutron captures that produce protons and 1.6 between gamma-rays and fast neutron captures that produce alpha particles.

crystal growth↗

Predicting Chandra CCD Degradation with the Chandra Radiation Model

Not long after launch of the Chandra X-Ray Observatory, it was discovered that the Advanced CCD Imaging Spectrometer (ACIS) detector was rapidly degrading due to radiation. Analysis by Chandra personnel showed that this degradation was due to 10w energy protons (100 - 200 keV) that scattered down the optical path onto the focal plane. In response to this unexpected problem, the Chandra Team developed a radiation-protection program that has been used to manage the radiation damage to the CCDs. This program consists of multiple approaches - scheduled sating of the ACIS detector from the radiation environment during passage through radiation belts, real-time monitoring of space weather conditions, on-board monitoring of radiation environment levels, and the creation of a radiation environment model for use in computing proton flux and fluence at energies that damage the ACIS detector. This radiation mitigation program has been very successful. The initial precipitous increase in the CCDs' charge transfer inefficiency (CTI) resulting from proton damage has been slowed dramatically, with the front-illuminated CCDS having an increase in CTI of only 2.3% per year, allowing the ASIS detector's expected lifetime to exceed requirements. This paper concentrates on one aspect of the Chandra radiation mitigation program, the creation of the Chandra Radiation Model (CRM). Because of Chandra's highly elliptical orbit, the spacecraft spends most of its time outside of the trapped radiation belts that present the severest risks to the ACIS detector. However, there is still a proton flux environment that must be accounted for in all parts of Chandra's orbit. At the time of Chandra's launch there was no engineering model of the radiation environment that could be used in the outer regions of the spacecraft's orbit, so the CRM was developed to provide the flux environment of 100 - 200 keV protons in the outer magnetosphere, magnetosheath, and solar wind regions of geospace. This presentation describes CRM, its role in Chandra operations, and its prediction of the ACIS CTI increase.

Minow, Joseph I.↗