At least 217 records · Page 12

Radiation Environment Model of Protons and Heavier Ions at Jupiter

We performed an in depth study of the methods used to review the geometric factors (GF) and sensitivity to charge particles of the Energetic Particle Detector instrument on board the Galileo Spacecraft. Monte Carlo simulations were performed to understand the interactions of electrons and ions (i. e., protons and alphas) with the sensitive regions of the instrument. The DC0 and B0 channels were studied with the intention of using them to update the jovian proton radiation model. The results proved that the B0 is a clean proton chanel without any concerns for contamination by heavier ions and electrons. In contrast, DC0 was found to be contaminated by electrons. Furthermore, we also found out that the B2 channel is a clean alpha particle channel (in other words, no contamination by electrons and/or protons).

Jupiter Radiation Environment↗

Accuracy of Analog Fiber-Optic Links in Pulsed Radiation Environments

Interferometric fiber-optic links used in pulsed-power experiments are evaluated for accuracy in the presence of radiation fields which alter fiber transmission. Amplitude-modulated format (e.g., Mach-Zehnder) and phase-modulated formats are compared. Historically, studies of radiation effects on optical fibers have focused on degradation and recovery of the fibers transmission properties; such work is either in the context of survivability of fibers in catastrophic conditions or suitability of fibers installed for command and control systems within an experimental facility [1], [2]. In this work, we consider links used to transmit realtime diagnostic data, and we analyze the error introduced by radiation effects during the drive pulse. The result is increased uncertainties in key parameters required to unfold the sinusoidal transfer function. Two types of modulation are considered: amplitude modulation typical of a Mach-Zehnder (M-Z) modulator [3], and phase modulation, which offers more flexible demodulation options but relies on the spatiotemporal coherence of the light in the fiber. The M-Z link is shown schematically in Fig. 1, and the phase-modulated link is shown in Fig. 2. We present data from two experimental environments: one with intense, controlled radiation fields to simulate conditions expected at the next generation of pulsed-power facilities, and the second with radiation effects below the noise level of the recording system. In the first case, we intentionally expose three types of single-mode fiber (SMF) to ionizing radiation and study the response by simultaneously monitoring phase and amplitude of the transmitted light. The phase and amplitude effects are evidently dominated by different physical phenomena, as their recovery dynamics are markedly different; both effects, though, show similar short-term behavior during exposure, integrating the dose at the dose levels studied, from 1 to 300 kRad, over the exposure times of 50 ps and 30 ns. In the second case, we present data using a state-of-the-art fiber-optic link for single-shot transmission and recording, fielded at the OMEGA laser facility on high-yield fusion experiments. Gamma reaction history data are measured with a gas Cherenkov detector (GCD) [4], [5] and transmitted by M-Z link to a 12 GHz digitizer. Since radiation effects on the fibers are not above the noise floor, the error analysis for the unfolded data is dominated by the performance of the fast digitizer, the photoreceiver, and the laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Fiber Sensors With High Spatial Resolution in Extreme Radiation Environments in Nuclear Reactor Cores

This paper is a comprehensive experimental report on the neutron radiation effects of distributed optical fiber sensors with enhanced Rayleigh scattering profiles in an in-pile environment. Femtosecond laser direct writing was used to inscribe Type-II modifications in standard telecom fibers and radiation-hardened fibers with fluorine-doped cores. Rayleigh backscattering signals were enhanced for continuous 1.5 m. In-pile lead-out sensors tests were carried out at the MIT Research Reactor for two months, which was operated at a nominal power of 5.7 MW with fast neutron (>0.1 MeV) flux of 1.29 × 1014 n/cm2/s and an in-core temperature of up to 560°C. Using the Optical Frequency Domain Reflectometry technique, the backscattering profiles of fiber sensors were interrogated with a 3-cm spatial resolution to monitor the temperature profile of the reactor. Results show that laser inscribed Type-II modifications in the form of nanogratings are highly stable against extreme temperature and ionizing radiation. Both standard telecom fibers and radiation-hardened fibers with laser-enhanced Rayleigh profiles can continuously perform distributed temperature measurements over the entire duration of the in-pile testing. Temperature coefficients of sensors and spectral shift quality were studied as functions of total radiation fluence. To the best of our knowledge, we present for the first time, the temperature profile of an operating nuclear reactor core with 3-cm spatial resolution, enabled by distributed fiber sensors with laser-enhanced Rayleigh scattering profiles. The high spatial resolution measurements can provide valuable data for the design and validation of digital twin and virtual reality of nuclear energy systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The geomagnetically trapped radiation environment: A radiological point of view

The regions of naturally occurring, geomagnetically trapped radiation are briefly reviewed in terms of physical parameters such as; particle types, fluxes, spectrums, and spatial distributions. The major emphasis is placed upon a description of this environment in terms of the radiobiologically relevant parameters of absorbed dose and dose-rate and a discussion of the radiological implications in terms of the possible impact on space vehicle design and mission planning.

Holly, F. E.↗

The Use of Heavy Ion Radiation as an Analog for Space Radiation Environment and Its Effects on Drug Stability

While it is common knowledge that electromagnetic radiation such as x-rays and gamma rays affect physical-chemical characteristics (PC) of compounds in addition to their toxic and mutagenic effects on biological systems, there are no reports on the effects of cosmic radiation encountered during space missions on stability of pharmaceuticals. Alterations in PC of drug formulations can adversely affect treatment with medications in space. Preliminary evaluation of stability and shelf-life of select pharmaceuticals (12) flown on space missions revealed that 37% and 40% of the formulations failed to meet USP requirements after shuttle and ISS flights, respectively. Based on these results, the current investigation is designed to examine the effect of proton (P) and heavy ion (Fe) radiation on 20 pharmaceutical preparations flown aboard the shuttle and ISS. The objectives of this project are: 1) Examine susceptibility of pharmaceuticals to short acute bouts of high intensity ionizing radiation species encountered during space flights; 2) Estimate extent of degradation of susceptible formulations as a function of intensity of each beam (P & Fe); and 3) compare and contrast the effects of single beam irradiation to that of a combined beam (P + Fe) that simulates space craft environment on drug stability. Irradiations were conducted at the Brookhaven National Laboratories (BNL) with beam strengths of 10 cGy, 10 or 50Gy of P and Fe beams separately. Preliminary evaluation of results revealed a reduction in the chemical content of label claim ranging 12-55 % for Augmentin, 7% for promethzine tablets and 9% for ciprofloxacin ointment. These results are in agreement, although less in magnitude than those observed during space flight and after gamma irradiation.

Vaksman, Z.↗

Radiation environment and hazards for a geosynchronous space station

An evaluation was made of the potential radiation hazards to the crew and equipment of a geosynchronous space station. Tissue dose rates for electron, bremsstrahlung, galactic cosmic rays, and solar proton events are included for parking longitudes of 110 and 290 degrees at orbit inclinations of 0, 30, and 45 degrees.

Wright, J. J.↗

Hardening electronic devices against very high total dose radiation environments

The possibilities and limitations of hardening silicon semiconductor devices to the high neutron and gamma radiation levels and greater than 10 to the eighth power rads required for the NERVA nuclear engine development are discussed. A comparison is made of the high dose neutron and gamma hardening potential of bipolar, metal insulator semiconductors and junction field effect transistors. Experimental data is presented on device degradation for the high neutron and gamma doses. Previous data and comparisons indicate that the JFET is much more immune to the combined neutron displacement and gamma ionizing effects than other transistor types. Experimental evidence is also presented which indicates that p channel MOS devices may be able to meet the requirements.

Buchanan, B.↗

Noise limitations of multiplier phototubes in the radiation environment of space

The contributions of Cerenkov emission, luminescence, secondary electron emission, and bremsstrahlung to radiation-induced data current and noise of multiplier phototubes were analyzed quantitatively. Fluorescence and Cerenkov emission in the tube window are the major contributors and can quantitatively account for dark count levels observed in orbit. Radiation-induced noise can be minimized by shielding, tube selection, and mode of operation. Optical decoupling of windows and cathode (side-window tubes) leads to further reduction of radiation-induced dark counts, as does reducing the window thickness and effective cathode area, and selection of window/cathode combinations of low fluorescence efficiency. In trapped radiation-free regions of near-earth orbits and in free space, Cerenkov emission by relativistic particles contributes predominantly to the photoelectron yield per event. Operating multiplier phototubes in the photon (pulse) counting mode will discriminate against these large pulses and substantially reduce the dark count and noise to levels determined by fluorescence.

Viehmann, W.↗

Diagnostic Components in Harsh Radiation Environments: Possible Overlap in R&D Requirements of IC and MF Systems

The next generation of large scale fusion devices--ITER/LMJ/NIF--will require diagnostic components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiation, and in some cases debris and shrapnel, at levels several orders of magnitude higher than those experienced in today's devices. For several years the question of possible synergy between inertial and the magnetic confinement research has been pursued by members of the respective communities. A first joint workshop specifically devoted to the identification and promotion of these synergies was organized in France, at Aix-en-Provence from June 27th to 29th, 2007. The workshop was attended by about 50 invited specialists. The participants identified a number of subject areas where common overlapping interests could benefit from additional interactions and meetings: windows, optical fibers, mirrors, cables, electronic components and 14 MeV neutron sources. In this paper we summarize the findings of these working groups. We put the discussion into context by including a brief description of the environments and the physical effects that have to be handled.

42 ENGINEERING↗