Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Doppler-shifted reflections of X rays in beamfoil spectroscopy

Carbon foils were positioned at roughly 10 deg to the conventional perpendicular position so that the spectrometer would view the beam on emergence from the foil, with no radiation shielded by a bowed or wrinkled foil or by the foil holder. Extraneous peaks due to reflected radiation were detected in the spectrum obtained with the tilted foil. A large satellite appears longward of the spectral line and is attributed to Doppler-shifted radiation reflected from the foil surface. Special tests arranged to validate the origin of the satellites are described. The relative intensity of the reflected radiation compared with the direct radiation observed is at variance with the relative intensities reported for longer wavelengths. The reasons for this, possible effects of spectrometer geometry, and applications in the investigation or generation of polarization remain to be investigated

Bernstein, E. M.↗

SiC As An Energetic Particle Detector

Several new technologies have been introduced recently in the region of semiconductor material for solid state detectors (SSD). Of particular interest is silicon carbide (SIC) since its band gap is larger than that of pure silicon, reducing its dark current and making SIC capable of operating at high temperatures and more tolerant of radiation damage. But the trade off is that a higher band gap also means fewer electron hole pairs generated, and thus a smaller signal, for detecting incident radiation. To determine what the lower limit of SiC detectors to energetic particles is, we irradiated a SiC diode with particles ranging in energy from 50 keV to 1.6 MeV and masses from 1 to 16 amu. We found that the SiC detectors sensitivity was comparable to that of pure silicon, with the SiC detector being able to measure particles down to 50 keV/amu and possibly lower.

Yan, F.↗

BLACK RADIATION DETECTOR

Efficiency of conical calorimeter for detecting black body radiation, based on spectral emissivity and reflectance measurements

SPECTRAL EMISSION↗

SMM detection of interstellar Al-26 gamma radiation

The gamma ray spectrometer on the Solar Maximum Mission Satellite has detected the interstellar Al-26 line when the Galactic center traversed its aperture. The center of the emission is consistent with the location of the Galactic center, but the spatial distribution is presently not well defined. The total flux in the direction of the Galactic center is 4.3 + or - 0.4) x .0001 gamma/sq cm-s-rad for an assumed population I distribution.

Share, G. H.↗

Development, applications, and future of infrared upconversion

Infrared upconversion is a technique that converts linearly polarized infrared photons to photons of higher frequency. The technique can be applied advantageously to the detection of IR radiation because the upconverted signal can be detected by photon-counting devices available for the visible spectral region. In addition, unlike presently available IR detectors, an upconversion device can provide sensitivity to IR radiation without the need for cryogenic cooling. Infrared upconversion was first demonstrated in 1961. By 1974, approximately 100% quantum conversion efficiency and a bandwidth of 1.81 microns had been attained. Photometric detection of IR radiation from various astronomical objects had also been demonstrated. Research is presently under way on the application of upconversion to astronomical spectroscopy and to imaging. The major drawback to the upconversion technique is the sheer bulk of the apparatus involved. It is anticipated that this problem can be overcome by applying the developing technology of integrated optics.

Gurski, T. R.↗

Astrometry with the ATF

A detailed study of the effects of gravitational radiation on the relative positions of objects was carried out with the hope that astrometric detection of gravitational radiation might be possible. The results are discouraging. It would appear that narrow-field instruments in the Astrometric Telescope Facility (ATF) class are still several orders of magnitude less accurate than would be required for this very delicate kind of measurement. However, the situation changes considerably when wide-field instruments are considered. An instrument such as POINTS ought to be able to detect gravitational radiation at this level with ease. The list of bright quasars has been augmented. Of particular interest is the finding of quasars near two open clusters and one planetary nebula. These would be useful in determining absolute parallaxes of these objects.

Jefferys, William H.↗

Cytogenetic Biodosimetry Using the Blood Lymphocytes of Astronauts

Cytogenetic analysis of blood lymphocytes remains the most sensitive and reliable method available for in vivo assessment of the biological effects of exposure to radiation and provides the most informative measurement of radiation induced health risks. To date chromosome damage has been assessed in lymphocytes from more than 30 astronauts before and after they participated in long-duration space missions of three months or more on board the International Space Station. For all individuals, the frequency of chromosome damage measured within a month of return from space was higher than their prefight yield and biodosimetry estimates lie within the range expected from physical dosimetry. Biodosimetry data provides a direct measurement of space radiation damage, which takes into account individual radiosensitivity in the presence of confounding factors such as microgravity and other stress conditions. In contrast to physical measurements, which are external to body and require multiple devices to detect all radiation types all of which have poor sensitivity to neutrons, biodosimetry is internal and includes the effects of shielding provided by the body itself plus chromosome damage shows excellent sensitivity to protons, heavy ions, and neutrons. In addition, chromosome damage is reflective of cancer risk and biodosimetry values can therefore be used to validate and develop risk assessment models that can be used to characterize excess health risk incurred by crewmembers. A review of astronaut biodosimetry data will be presented along with recent findings on the persistence of space radiation induced chromosome damage and the cytogenetic effects of repeat long duration missions

George, Kerry↗

Biological Dosimetry in Astronauts

Biodosimetry data provides a direct measurement of space radiation damage, which takes into account individual radiosensitivity in the presence of confounding factors such as microgravity and other stress conditions. In contrast to physical measurements, which are external to body and require multiple devices to detect all radiation types all of which have poor sensitivity to neutrons, biodosimetry is internal and includes the effects of shielding provided by the body itself plus chromosome damage shows excellent sensitivity to protons, heavy ions, and neutrons. Moreover, chromosome damage maybe reflective of cancer risk and biodosimetry values can therefore be used to validate and develop risk assessment models that can be used to characterize excess health risk incurred by crewmembers. Cytogenetic biodosimetry methods have been used extensively for assessing terrestrial radiation exposures, and remain the most sensitive in vivo indicator of dose available to date. The main cellular radiation target is the DNA, and radiation-induced damage in the DNA molecule can be visualized as aberrations in the chromosomes (breaks in the chromosomes or exchanges of DNA material between different chromosomes). Normal chromosomes contain a single condensed and constricted area called a centromere that helps the chromosome number to remain stable when a cell divides.

George, Kerry↗

Surface reflections of Pioneer Venus probe signals

As the four Pioneer Venus probes fell within the atmosphere toward the surface of Venus, each of them transmitted a radio signal directly to earth. Because of the relatively broad antenna beamwidth of these small probes, some of the transmitted power went down to the surface of Venus. This paper reports the discovery that the radio signals scattered off the surface are not only detectable but that their characteristics can be determined with a surprising degree of certainty. From these characteristics one can determine parameters of the Venusian atmospheric winds and of the surface that promise to be useful. Most of the scattered energy is that which originally radiated from the probes in a near-horizontal direction; the downward-directed radiation is detectable but much weaker. Refraction in the atmosphere of Venus clearly plays a significant role in establishing both the strength of scatter and its Doppler shift.

Croft, T. A.↗

The enigmatic T Tauri radio source

We have analyzed eight high angular resolution images of the prototype low mass pre-main-sequence star T Tauri obtained with the Very Large Array between 1987 and 1990. Our objectives were to confirm a recent report that the radio emission is both variable and circularly polarized, to determine whether this behavior originates in the optical star or in the infrared source lying 0.6 sec to its south, and to identify possible emission mechanisms. No variability or circular polarization was detected in the weak (approximately equals 1 mJy) radio emission associated with the visible star, down to levels of approximately equals 10%. The observed flux can be accounted for by free-free emission from an ionized wind with a mass-loss rate M = 3.7 x 10(exp -8) solar mass yr(exp -1), but a more accurate determination of the spectral index is needed to test the validity of sperical wind models. In sharp contrast, the 3.6 cm emission of the infrared source is variable (approximately equals 4-7 mJy) on time scales less than or equal to 3 days and circularly polarized at low levels of approximately equals 3% - 5%. The polarization was left circular when detected during periods of low radio activity but changed to right circular during a radio outburst, similar to the reversals that have been seen in some RS CVn binary systems. The spectral index is negative during 'quiescence,'and we argue that the emission is nonthermal gyrosynchrotron radiation. The detection of magnetic radio activity in this optically invisible infrared source sparks new interest in clarifying its evolutionary status. Sensitive 3.6 cm images reveal weak emission extending approximately equals 1 sec west of the T Tau system that is probably associated with high-velocity shock-excited gas flowing toward HH-1555. We find no radio evidence for a putative third component north of the visible star.

Skinner, Stephen L.↗

Detection of galactic Al-26 gamma radiation by the SMM spectrometer

The Solar Maximum Mission satellite's gamma-ray spectrometer has detected a line near 1.81 MeV in each of the three years (1980-1982) over which the Galactic center traversed the broad aperture of that instrument. No significant intensity variation is noted over this period. The Galactic center/anticenter intensity ratio is greater than 2.5, and the center of the emission is noted to be consistent with the location of the Galactic center. For an assumed source distribution which follows the more than 100 MeV Galactic gamma radiation, the total flux in the direction of the Galactic center and the measured energy of the line are consistent with the detection of a narrow gamma-ray line from interstellar Al-26 by HEAO 3 in 1979-1980.

Share, G. H.↗

What Threats to Human Health Does Space Radiation Pose in Orbit

The Space Shuttle program spanned more than the entire length of a solar cycle. Investigations aimed towards understanding the health risks of the astronauts from exposures to space radiation involved mostly physical measurements of the dose and the linear energy transfer (LET) spectrum. Measurement of the dose rate on the Shuttle provided invariable new data for different periods of the solar cycle, whereas measurement of the LET spectrum using the tissue equivalent proportional counter (TEPC) produced the most complete mapping of the radiation environment of the low Earth orbits (LEO). Exposures to the Shuttle astronauts were measured by the personal dosimeter worn by the crewmembers. Analysis of over 300 personal dosimeter readings indicated a dependence on the mission duration, the altitude and inclination of the orbit, and the solar cycle, with the crewmembers on the launch and repair of the Hubble telescope receiving the highest doses due to the altitude of the mission. Secondary neutrons inside the Shuttle were determined by recoil protons or with Bonner spheres, and may contribute significantly to the risks of the crewmembers. In addition, the skin dose and the doses received at different organs were compared using a human phantom onboard a Shuttle mission. A number of radiobiology investigations wer e also performed. The biological doses were determined on six astronauts/cosmonauts on long-duration Shuttle/Mir missions and on two crewmembers on a Hubble repair mission by analyzing the damages in the chromosomes of the crewmembers? white blood cells. Several experiments were also conducted to address the question of possible synergistic effects of spaceflight, microgravity in particular, on the repair of radiation-induced DNA damages. The experimental design included exposure of cells before launch, during flight, or after landing. These physical and biological studies were invaluable in predicting the health risks for astronauts on ISS and future exploration missions. Educational Objectives: A group of high school students flew color negative films on tw o Shuttle missions to detect the radiation environment in orbit. This and other experiments onboard of the Shuttle were aimed at educating the general public of the space program.

Wu, Honglu↗

The implications of precise timekeeping of Doppler gravitational wave observations

Gravitational radiation from galactic and extragalactic astrophysical sources will induce spatial strains in the solar system, strains which can be measured directly by the Doppler radio link to distant spacecraft. Current noise sources in Pioneer and Voyager Doppler data are delineated and a comparison is made with expected signal levels from gravitational wave sources. The main conclusion is that it is possible to detect gravitational radiation with current DSN hydrogen maser systems stable in fractional frequency + or - 2 x 10 to the minus 14th power over 1000 sec. In the future, however, a serious Doppler observational program in gravitational wave astronomy will require frequency systems stable to at least 10 to the minus 16th power, but at the same time the current single frequency S-band uplink transmission will have to be replaced by a dual frequency capability.

Anderson, J. D.↗

Cell killing and chromatid damage in primary human bronchial epithelial cells irradiated with accelerated 56Fe ions

We examined cell killing and chromatid damage in primary human bronchial epithelial cells irradiated with high-energy 56Fe ions. Cells were irradiated with graded doses of 56Fe ions (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The survival curves for cells plated 1 h after irradiation (immediate plating) showed little or no shoulder. However, the survival curves for cells plated 24 h after irradiation (delayed plating) had a small initial shoulder. The RBE for 56Fe ions compared to 137Cs gamma rays was 1.99 for immediate plating and 2.73 for delayed plating at the D10. The repair ratio (delayed plating/immediate plating) was 1.67 for 137Cs gamma rays and 1.22 for 56Fe ions. The dose-response curves for initially measured and residual chromatid fragments detected by the Calyculin A-mediated premature chromosome condensation technique showed a linear response. The results indicated that the induction frequency for initially measured fragments was the same for 137Cs gamma rays and 56Fe ions. On the other hand, approximately 85% of the fragments induced by 137Cs gamma rays had rejoined after 24 h of postirradiation incubation; the corresponding amount for 56Fe ions was 37%. Furthermore, the frequency of chromatid exchanges induced by gamma rays measured 24 h after irradiation was higher than that induced by 56Fe ions. No difference in the amount of chromatid damage induced by the two types of radiations was detected when assayed 1 h after irradiation. The results suggest that high-energy 56Fe ions induce a higher frequency of complex, unrepairable damage at both the cellular and chromosomal levels than 137Cs gamma rays in the target cells for radiation-induced lung cancers.

NASA Discipline Radiation Health↗

Shock Radiation Tests for Saturn and Uranus Entry Probes

This paper describes a test series in the Electric Arc Shock Tube at NASA Ames Research Center with the objective of quantifying shock-layer radiative heating magnitudes for future probe entries into Saturn and Uranus atmospheres. Normal shock waves are measured in Hydrogen/Helium mixtures (89:11 by mole) at freestream pressures between 13-66 Pa (0.1-0.5 Torr) and velocities from 20-30 km/s. No shock layer radiation is detected below 25 km/s, a finding consistent with predictions for Uranus entries. Between 25-30 km/s, radiance is quantified from the Vacuum Ultraviolet through Near Infrared, with focus on the Lyman-alpha and Balmer series lines of Hydrogen. Shock profiles are analyzed for electron number density and electronic state distribution. The shocks do not equilibrate over several cm, and distributions are demonstrated to be non-Boltzmann. Radiation data are compared to simulations of Decadal survey entries for Saturn and shown to be significantly lower than predicted with the Boltzmann radiation model.

Saturn Probe↗