Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Safety and effectiveness of a non-electric infant warmer for hypothermia in Rwanda: A cluster-randomized stepped-wedge trial

Background: Neonatal hypothermia is a common source of morbidity and mortality in low resource settings. We developed the Dream Warmer, a low cost, re-usable non-electric infant warmer to prevent and treat hypothermia. Methods: We conducted a cluster-randomized stepped-wedge trial. The primary aim was to assess the effect on overall euthermia rates of introducing the warmer compared to standard of care in rural Rwandan hospitals. The secondary aims were to assess effects of warmer introduction on mortality, as well as the safety and feasibility of the warmer. Ten district hospitals participated in the study from November 19th 2019 to July 15th 2020. Patients were eligible to use the warmer if they were 1) hypothermic (temp < 36·5 °C) or 2) or at risk of hypothermia (weight < 2·5 kg or estimated post menstrual age < 35 weeks) when Kangaroo Mother Care was not available. An encounter was defined as the data from an individual infant on a single day. Trial of a Non Electric Infant Warmer for Prevention and Treatment of Hypothermia in Rwanda [NCT03890211]. Findings: Over the study period, 3179 patients were enrolled across the ten neonatal wards, yielding 12,748 encounters; 464 unique infants used the warmer 892 times, 79% eligible due to hypothermia. Because of limited study nurse resources, the warmer was used in only 18% of eligible encounters. Despite this low rate of warmer use, the rate of euthermia rose from 51% (95% CI 50–52%) of encounters pre-intervention to 67% (66–68%) post-intervention; p < 0·0001. Among the encounters in which the warmer was used, only 11% (9–13%) remained hypothermic. While mortality rates pre- and post-intervention did not change, mortality rate among those who used the warmer was significantly lower than among those who did not (0·9% vs 2·8%, p = 0·01). Use of the warmer did not affect hyperthermia rates. There were no safety concerns or instances of incorrect warmer use. Interpretation: Introduction of the warmer increased rates of euthermia with no associated safety concerns.

60 APPLIED LIFE SCIENCES↗

Cross-scale modeling of storm surge, tide, and inundation in Mid-Atlantic Bight and New York City during Hurricane Sandy, 2012

Driven by high-resolution NAM (North America Mesoscale) and ECMWF (European Centre for Medium-Range Weather Forecasts) atmospheric fields, a 3-D unstructured grid SCHISM (Semi-implicit Cross-scale Hydroscience Integrated System Model) was applied to simulate total water level in the Mid-Atlantic Bight during Hurricane Sandy in 2012. The simulated storm surge, tide, significant wave height, and wave peak period results compared favorably with NOAA observations along US East Coast, Long Island Sound, and New York Harbor. The maximum total water level at The Battery in the New York Harbor was accurately simulated with an absolute error of less than 0.08 m (out of 2.9 m peak surge) and a timing difference less than 10 min, which includes the effects on the order of 0.1–0.3 m (5–10%) from the coastal setup induced by the surface waves. The scenario comparisons of (1) “NAM” versus “ECMWF”, (2) “2-D” versus “3-D”, and (3) “with” versus “without” wind wave model were examined. The 3-D barotropic model forced by ECMWF including the effects of wind waves performs the best, attributed to wave-induced radiation stress and reduction of bottom stress when the 3-D version is used. Simultaneously, the ELCIRC-Sub model, using a 5-m topography/bathymetry sub-grid and a regular 200-m resolution finite volume computational model grid, was developed to simulate the street-level inundation in New York City. The momentum and mass fluxes calculated by the coarser base grid model were effectively coupled with the sub-grid so that running a full-blown high-resolution base model is not required. The ELCIRC-Sub model uses MPI (Message Passing Interface) parallel computing to enlarge the coverage of the land surface and an efficient non-linear solver to improve the accuracy of the wetting-and-drying processes. The temporal comparisons of modeled water level with NOAA's tidal stations and USGS' rapid-deployed gauges showed overall performance with an average error of 0.1 m. Particularly, ELCIRC-Sub captured the profile of the highest peak surge (3.9 m), which rose 2 m within 3 hour at Kings Point, NY. The spatial comparisons of the modeled peak water level at 80 surveyed locations showed an average error less than 0.13 m. The modeled maximum inundation extent also matched well with an 80% hit rate against FEMA's Hurricane Sandy maximum flooding extent.

54 ENVIRONMENTAL SCIENCES↗

Which Reservoir for Low Cost Capture, Transportation, and Storage?

Quality and location of a carbon dioxide (CO 2 ) storage reservoir are critical for low cost carbon capture and storage (CCS). This analysis models the combination of capture, transportation, and storage costs to estimate a total cost of CCS. Cost of capture at the source is available for annual rates between 4.1 and 0.7 million tonnes of CO 2 . Cost of transportation is modeled for the distance between the source and the storage reservoir. Cost of CO 2 storage is modeled for four representative reservoirs, two Rose Run and two Mt Simon reservoirs, each reservoir in a dome or regional dip structural setting.

03 NATURAL GAS↗

An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy

X-ray diffraction microscopy (XDM) is a new form of x-ray imaging that is being practiced at several third-generation synchrotron-radiation x-ray facilities. Nine years have elapsed since the technique was first introduced and it has made rapid progress in demonstrating high-resolution three-dimensional imaging and promises few-nm resolution with much larger samples than can be imaged in the transmission electron microscope. Both life- and materials-science applications of XDM are intended, and it is expected that the principal limitation to resolution will be radiation damage for life science and the coherent power of available x-ray sources for material science. In this paper we address the question of the role of radiation damage. Here, we use a statistical analysis based on the so-called "dose fractionation theorem" of Hegerl and Hoppe to calculate the dose needed to make an image of a single life-science sample by XDM with a given resolution. We find that for simply-shaped objects the needed dose scales with the inverse fourth power of the resolution and present experimental evidence to support this finding. To determine the maximum tolerable dose we have assembled a number of data taken from the literature plus some measurements of our own which cover ranges of resolution that are not well covered otherwise. The conclusion of this study is that, based on the natural contrast between protein and water and "Rose-criterion" image quality, one should be able to image a frozen-hydrated biological sample using XDM at a resolution of about 10 nm.

36 MATERIALS SCIENCE↗

Industrial pollution and cancer in Spain: An important public health issue

Cancer can be caused by exposure to air pollution released by industrial facilities. The European Pollutant Release and Transfer Register (E-PRTR) has made it possible to study exposure to industrial pollution. This study seeks to describe the industrial emissions in the vicinity of Spanish towns and their temporal changes, and review our experience studying industrial pollution and cancer. Data on industrial pollutant sources (2007–2010) were obtained from the E-PRTR registries. Population exposure was estimated by the distance from towns to industrial facilities. We calculated the amount of carcinogens emitted into the air in the proximity (<5 km) of towns and show them in municipal maps. We summarized the most relevant results and conclusions reported by ecological E-PRTR-based on studies of cancer mortality and industrial pollution in Spain and the limitations and result interpretations of these types of studies. There are high amounts of carcinogen emissions in the proximity of towns in the southwest, east and north of the country and the total amount of emitted carcinogens is considerable (e.g. 20 Mt of arsenic, 63 Mt of chromium and 9 Mt of cadmium). Although the emissions of some carcinogens in the proximity of certain towns were reduced during the study period, emissions of benzene, dioxins+furans and polychlorinated biphenyls rose. Moreover, the average population of towns lying within a 5 km radius from emission sources of carcinogens included in the International Agency for Research on Cancer list of carcinogens was 9 million persons. On the other hand, the results of the reviewed studies suggest that those Spanish regions exposed to the pollution released by certain types of industrial facilities have around 17% cancer excess mortality when compared with those unexposed. Moreover, excess mortality is focused on digestive and respiratory tract cancers, leukemias, prostate, breast and ovarian cancers. Despite their limitations, ecological studies are a useful tool in environmental epidemiology, not only for proposing etiological hypotheses about the risk of living close to industrial pollutant sources, but also for providing data to account for situations of higher mortality in specific areas. Nevertheless, the reduction of emissions should be a goal, with special relevance given to establishing limits for known carcinogens and other toxic substances in the environs of population centers, as well as industry-specific emission limits. - Highlights: • The amount of carcinogens emitted into air in proximity to population is considerable. • Some towns near industrial pollutant sources have a cancer mortality excess. • Cancer problems in exposed people are centered on digestive and respiratory systems. • Reduction of emissions should be a goal, specially with recognized carcinogens.

54 ENVIRONMENTAL SCIENCES↗

The pumice raft-forming 2012 Havre submarine eruption was effusive

A long-standing conceptual model for deep submarine eruptions is that high hydrostatic pressure hinders degassing and acceleration, and suppresses magma fragmentation. The 2012 submarine rhyolite eruption of Havre volcano in the Kermadec arc provided constraints on critical parameters to quantitatively test these concepts. This eruption produced a >1 km 3 raft of floating pumice and a 0.1 km 3 field of giant (>1 m) pumice clasts distributed down-current from the vent. We address the mechanism of creating these clasts using a model for magma ascent in a conduit. We use water ingestion experiments to address why some clasts float and others sink. We show that at the eruption depth of 900 m, the melt retained enough dissolved water, and hence had a low enough viscosity, that strain-rates were too low to cause brittle fragmentation in the conduit, despite mass discharge rates similar to Plinian eruptions on land. There was still, however, enough exsolved vapor at the vent depth to make the magma buoyant relative to seawater. Buoyant magma was thus extruded into the ocean where it rose, quenched, and fragmented to produce clasts up to several meters in diameter. We show that these large clasts would have floated to the sea surface within minutes, where air could enter pore space, and the fate of clasts is then controlled by the ability to trap gas within their pore space. We show that clasts from the raft retain enough gas to remain afloat whereas fragments from giant pumice collected from the seafloor ingest more water and sink. The pumice raft and the giant pumice seafloor deposit were thus produced during a clast-generating effusive submarine eruption, where fragmentation occurred above the vent, and the subsequent fate of clasts was controlled by their ability to ingest water.

58 GEOSCIENCES↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Relative Contributions of Radiation and Cisplatin-Based Chemotherapy to Sensorineural Hearing Loss in Head-and-Neck Cancer Patients

Purpose: To investigate the risk of sensorineural hearing loss (SNHL) in patients with head-and-neck cancer and treated with radiation therapy (RT) or concomitant cisplatin-based chemoradiation, the relationship among SNHL and radiation dose to the cochlea, the use of two common cisplatin dose regimens. Methods and Materials: A total of 62 head-and-neck cancer patients treated with curative intent were included in this prospective study. Of the patients, 21 received RT alone, 27 received 40 mg/m{sup 2} weekly cisplatin, 13 received 100 mg/m{sup 2} every 3 weeks during RT, and 1 received RT with weekly epidermal growth factor receptor inhibitor antibody. The effect of chemotherapy and RT dose on hearing was determined using a model that accounted for the age and variability between each ear for each patient. Results: We constructed a model to predict dose-dependent hearing loss for RT or cisplatin-based chemotherapy either alone or in combination. For patients only receiving RT, no significant hearing loss was found at doses to the cochlea of less than 40 Gy. Patients receiving 100 mg/m{sup 2} or 40 mg/m{sup 2} of cisplatin chemotherapy had an estimated +21.5 dB and +9.5 dB hearing loss at 8,000 Hz with low radiation doses (10 Gy), which rose to +38.4 dB and +18.9 dB for high radiation doses (40 Gy). Conclusions: Use of RT alone with doses of less than 40 Gy did not result in clinically significant hearing loss. High-frequency SNHL was profoundly damaged in patients who received concomitant cisplatin when doses of 100 mg/m{sup 2} were used. The threshold cochlear dose for hearing loss with cisplatin-based chemotherapy and RT was predicted to be 10 Gy. The inner ear radiation dose constraints and cisplatin dose intensity should be considered in the treatment of advanced head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Men With Intermediate-Risk Prostate Cancer: Analysis of Short- and Medium-Term Toxicity and Quality of Life

Purpose: To determine the short- and medium-term effects of a single high-dose-rate brachytherapy fraction of 15Gy and hypofractionated external beam radiation therapy for prostate cancer. Methods and Materials: Eligible patients had localized prostate cancer with a Gleason score of 7 and a prostate-specific antigen (PSA) concentration of <20 ng/ml or a Gleason score of 6 with a PSA concentration of 10 to 20 ng/ml. Patients received high-dose-rate brachytherapy as a single 15-Gy dose, followed by external beam radiation therapy at 37.5Gy in 15 fractions, and were followed prospectively for toxicity (using Common Terminology Criteria for Adverse Events version 3.0), urinary symptoms (using the International Prostate Symptom Score [IPSS]), erectile function (with the International Index of Erectile Function [IIEF]), and health-related quality of life (with the Expanded Prostate Cancer Index Composite [EPIC]). Clinical examinations and PSA measurements were performed at every visit, and prostate biopsies were repeated at 2 years. The trial accrued 125 patients, with a median follow-up of 1.14 years. Results: Acute grade 2 and 3 genitourinary toxicity occurred in 62% and 1.6% of patients, respectively, and acute grade 2 gastrointestinal toxicity occurred in 6.5% of patients. No grade 3 late toxicity has occurred: 47% of patients had grade 2 genitourinary and 10% of patients had grade 2 gastrointestinal toxicity. Median IPSSs rose from 5 at baseline to 12 at 1 month and returned to 7 at 3 months. Of the total number of patients who were initially potent (IIEF, >21), 8% of patients developed mild to moderate dysfunction, and 27% of patients developed severe erectile dysfunction. Baseline EPIC bowel, urinary, and sexual bother scores decreased by 9, 7, and 19 points, respectively, at 1 year. No patient has experienced biochemical failure, and 16 of the first 17 biopsy results showed no malignancy. Conclusions: Treatment is well tolerated in the short and medium term, with low toxicity and encouraging early indicators of disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Positron Emission Tomography-Computed Tomography in the Management of Anal Cancer

Purpose: Pre- and post-treatment staging of anal cancer are often inaccurate. The role of positron emission tomograpy-computed tomography (PET-CT) in anal cancer is yet to be defined. The aim of the study was to compare PET-CT with CT scan, sentinel node biopsy results of inguinal lymph nodes, and anal biopsy results in staging and in follow-up of anal cancer. Methods and Materials: Fifty-three consecutive patients diagnosed with anal cancer underwent PET-CT. Results were compared with computed tomography (CT), performed in 40 patients, and with sentinel node biopsy (SNB) (41 patients) at pretreatment workup. Early follow-up consisted of a digital rectal examination, an anoscopy, a PET-CT scan, and anal biopsies performed at 1 and 3 months after the end of treatment. Data sets were then compared. Results: At pretreatment assessment, anal cancer was identified by PET-CT in 47 patients (88.7%) and by CT in 30 patients (75%). The detection rates rose to 97.9% with PET-CT and to 82.9% with CT (P=.042) when the 5 patients who had undergone surgery prior to this assessment and whose margins were positive at histological examination were censored. Perirectal and/or pelvic nodes were considered metastatic by PET-CT in 14 of 53 patients (26.4%) and by CT in 7 of 40 patients (17.5%). SNB was superior to both PET-CT and CT in detecting inguinal lymph nodes. PET-CT upstaged 37.5% of patients and downstaged 25% of patients. Radiation fields were changed in 12.6% of patients. PET-CT at 3 months was more accurate than PET-CT at 1 month in evaluating outcomes after chemoradiation therapy treatment: sensitivity was 100% vs 66.6%, and specificity was 97.4% vs 92.5%, respectively. Median follow-up was 20.3 months. Conclusions: In this series, PET-CT detected the primary tumor more often than CT. Staging of perirectal/pelvic or inguinal lymph nodes was better with PET-CT. SNB was more accurate in staging inguinal lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regional Normal Lung Tissue Density Changes in Patients Treated With Stereotactic Body Radiation Therapy for Lung Tumors

Purpose: To describe regional lung tissue density changes in normal lung tissue of patients with primary and metastatic lung tumors who received stereotactic body radiation therapy (SBRT). Methods and Materials: A total of 179 post-SBRT follow-up computed tomography (CT) scans of 62 patients who received SBRT between 2003 and 2009 were studied. Median prescription dose was 54 Gy (range, 30-60 Gy) in 3 to 5 fractions. SBRT-induced lung density changes on post-SBRT follow-up CT were evaluated at approximately 3, 6, 12, 18, 24, and 30 months after treatment. Dose-response curves (DRC) were generated for SBRT-induced lung damage by averaging CT number (HU) changes for regions of the lungs receiving the same dose at 5-Gy intervals. Results: For all follow-up interval periods, CT numbers linearly increased with dose until 35 Gy and were constant thereafter. For 3, 18, 24, and 30 months, the rate of relative electron density increase with dose was approximately 0.24% per Gy. At 6 months, the rate was also similar below 20 Gy but then rose to 0.6% per Gy above this threshold. After 6 months, DRCs were mostly time-independent. When split between patients treated with 3 fractions of 12 to 20 Gy (median, 20 Gy; average tumor volume, 12 {+-} 16 cm{sup 3}) and with >3 fractions of 6 to 12.5 Gy (median, 9 Gy; average tumor volume, 30 {+-} 40 cm{sup 3}), DRCs differed significantly. In both cases, CT changes at 3, 18, 24, and 30 months were identical to those of the population DRC; however, patients who received >3 fractions showed 6-month CT changes that were more than twice those for the group that received 3 fractions. Conclusions: This analysis of SBRT-induced normal lung density changes indicates that lung normal tissue has more pronounced self-limited acute effects than late effects. Differences in acute CT changes following treatments in 3 fractions were considerably less than for treatments in >3 fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Pneumonitis Risk: A Dosimetric Alternative to Mean Lung Dose

Purpose: To determine whether the association between mean lung dose (MLD) and risk of severe (grade {>=}3) radiation pneumonitis (RP) depends on the dose distribution pattern to normal lung among patients receiving 3-dimensional conformal radiation therapy for non-small-cell lung cancer. Methods and Materials: Three cohorts treated with different beam arrangements were identified. One cohort (2-field boost [2FB]) received 2 parallel-opposed (anteroposterior-posteroanterior) fields per fraction initially, followed by a sequential boost delivered using 2 oblique beams. The other 2 cohorts received 3 or 4 straight fields (3FS and 4FS, respectively), ie, all fields were irradiated every day. The incidence of severe RP was plotted against MLD in each cohort, and data were analyzed using the Lyman-Kutcher-Burman (LKB) model. Results: The incidence of grade {>=}3 RP rose more steeply as a function of MLD in the 2FB cohort (N=120) than in the 4FS cohort (N=138), with an intermediate slope for the 3FS group (N=99). The estimated volume parameter from the LKB model was n=0.41 (95% confidence interval, 0.15-1.0) and led to a significant improvement in fit (P=.05) compared to a fit with volume parameter fixed at n=1 (the MLD model). Unlike the MLD model, the LKB model with n=0.41 provided a consistent description of the risk of severe RP in all three cohorts (2FB, 3FS, 4FS) simultaneously. Conclusions: When predicting risk of grade {>=}3 RP, the mean lung dose does not adequately take into account the effects of high doses. Instead, the effective dose, computed from the LKB model using volume parameter n=0.41, may provide a better dosimetric parameter for predicting RP risk. If confirmed, these findings support the conclusion that for the same MLD, high doses to small lung volumes ('a lot to a little') are worse than low doses to large volumes ('a little to a lot').

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adoption of Intensity Modulated Radiation Therapy For Early-Stage Breast Cancer From 2004 Through 2011

Purpose: Intensity modulated radiation therapy (IMRT) is a newer method of radiation therapy (RT) that has been increasingly adopted as an adjuvant treatment after breast-conserving surgery (BCS). IMRT may result in improved cosmesis compared to standard RT, although at greater expense. To investigate the adoption of IMRT, we examined trends and factors associated with IMRT in women under the age of 65 with early stage breast cancer. Methods and Materials: We performed a retrospective study of early stage breast cancer patients treated with BCS followed by whole-breast irradiation (WBI) who were ≤65 years old in the National Cancer Data Base from 2004 to 2011. We used logistic regression to identify factors associated with receipt of IMRT (vs standard RT). Results: We identified 11,089 women with early breast cancer (9.6%) who were treated with IMRT and 104,448 (90.4%) who were treated with standard RT, after BCS. The proportion of WBI patients receiving IMRT increased yearly from 2004 to 2009, with 5.3% of WBI patients receiving IMRT in 2004 and 11.6% receiving IMRT in 2009. Further use of IMRT declined afterward, with the proportion remaining steady at 11.0% and 10.7% in 2010 and 2011, respectively. Patients treated in nonacademic community centers were more likely to receive IMRT (odds ratio [OR], 1.36; 95% confidence interval [CI], 1.30-1.43 for nonacademic vs academic center). Compared to privately insured patients, the uninsured patients (OR, 0.81; 95% CI, 0.70-0.95) and those with Medicaid insurance (OR, 0.87; 95% CI, 0.79-0.95) were less likely to receive IMRT. Conclusions: The use of IMRT rose from 2004 to 2009 and then stabilized. Important nonclinical factors associated with IMRT use included facility type and insurance status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Authorship in Radiation Oncology: Proliferation Trends Over 30 Years

Purpose: To investigate authorship trends in the radiation oncology literature. Methods and Materials: We examined the authorship credits of “original research articles” within 2 popular radiation oncology journals–International Journal of Radiation Oncology, Biology, Physics and Radiotherapy and Oncology–in 1984, 1994, 2004, and 2014. We compared the number of authors per publication during these 4 time periods using simple linear regression as a test for trend. We investigated additional author characteristics in a subset of articles. Results: A total of 2005 articles were eligible. The mean number of authors per publication rose from 4.3 in 1984 to 9.1 in 2014 (P<.001). On subset analysis of 400 articles, there was an increase in the percentage of multidisciplinary bylines (from 52% to 72%), multi-institutional bylines (from 20% to 53%), and publications with a trainee first author (from 16% to 56%) during the study period. Conclusions: The mean number of authors per publication has more than doubled over the last 30 years in the radiation oncology literature. Possible explanations include increasingly complex and collaborative research as well as honorary authorship. Explicit documentation of author contributions could help ensure that scientific work is credited according to accepted standards.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Local Therapy Utilization and Cost for Early-Stage Breast Cancer in Older Women: Implications for Payment and Policy Reform

Purpose: Older women with early-stage disease constitute the most rapidly growing breast cancer demographic, yet it is not known which local therapy strategies are most favored by this population in the current era. Understanding utilization trends and cost of local therapy is important for informing the design of bundled payment models as payers migrate away from fee-for-service models. We therefore used the Surveillance, Epidemiology, and End Results Medicare database to determine patterns of care and costs for local therapy among older women with breast cancer. Methods and Materials: Treatment strategy and covariables were determined in 55,327 women age ≥66 with Tis-T2N0-1M0 breast cancer who underwent local therapy between 2000 and 2008. Trends in local therapy were characterized using Joinpoint. Polychotomous logistic regression determined predictors of local therapy. The median aggregate cost over the first 24 months after diagnosis was determined from Medicare claims through 2010 and reported in 2014 dollars. Results: The median age was 75. Local therapy distribution was as follows: 27,896 (50.3%) lumpectomy with external beam radiation, 18,356 (33.1%) mastectomy alone, 6159 (11.1%) lumpectomy alone, 1488 (2.7%) mastectomy with reconstruction, and 1455 (2.6%) lumpectomy with brachytherapy. Mastectomy alone declined from 39.0% in 2000 to 28.2% in 2008, and the use of breast conserving local therapies rose from 58.7% to 68.2%. Mastectomy with reconstruction was more common among the youngest, healthiest patients, whereas mastectomy alone was more common among patients living in rural low-income regions. By 2008, the costs were $36,749 for lumpectomy with brachytherapy, $35,030 for mastectomy with reconstruction, $31,388 for lumpectomy with external beam radiation, $21,993 for mastectomy alone, and $19,287 for lumpectomy alone. Conclusions: The use of mastectomy alone in older women declined in favor of breast conserving strategies between 2000 and 2008. Using these cost estimates, price points for local therapy bundles can be constructed to incentivize the treatment strategies that confer the highest value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EPIsembleVis: A geo-visual analysis and comparison of the prediction ensembles of multiple COVID-19 models

In this work, we present EPIsembleVis, a web-based comparative visual analysis tool for evaluating the consistency of multiple COVID-19 prediction models. Our approach analyzes a collection of COVID-19 predictions from different epidemiological models as an ensemble and utilizes two metrics to quantify model performance. These metrics include (a) prediction uncertainty (represented as the dispersion of predictions in each ensemble) and (b) prediction error (calculated by comparing individual model predictions with the recorded data). Through an interactive visual interface, our approach provides a data-driven workflow for (a) selecting and constructing the COVID-19 model prediction ensemble based on the spatiotemporal overlap of available predictions of multiple epidemiological models, (b) quantifying the model performance using both the uncertainty of each model prediction ensemble, and the error of each ensemble member that represents individual model predictions, and (c) visualizing the spatiotemporal variability in the projection performance of individual models using a suite of novel ensemble visualization techniques, such as the data availability map, a spatiotemporal textured-tile calendar, multivariate rose chart, and time-series leaflet glyph. We demonstrate the capability of our ensemble visual interface through a case study that investigates the performance of weekly COVID-19 predictions, which are provided through the COVID-19 Forecast Hub UMass-Amherst Influenza Forecasting Center of Excellence [47] for the United States and United States Territories. The EPIsembleVis tool is implemented using open-source web technologies and adaptive system design, rendering it interoperable with Elasticsearch and Kibana for automatically ingesting COVID-19 predictions from online repositories, and it is generalizable for analyzing worldwide projections from more epidemiological models.

60 APPLIED LIFE SCIENCES↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗