Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF superconductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

An Engineering Prototype of a Late Stage Ionization Cooling Cell for a Muon Collider

Achieving the low emittances required for a muon collider requires ionization cooling. Much of that cooling occurs in compact cooling cells where superconducting coils and conventional RF cavities are closely interleaved. The real challenges for these cooling cells reside in their engineering challenges: high field solenoids, RF cavities, and absorbers, often designed near technological limits, placed in close proximity to each other. We thus propose to build a prototype ionization cooling cell to demonstrate the capability of constructing an ionization cooling channel reaching the lowest emittances and to provide engineering input for the design of such beamlines.

43 PARTICLE ACCELERATORS↗

Progress towards the completion of the proton power upgrade project

The Proton Power Upgrade project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion in early 2025, 2 MW of beam power will be available for neutron production at the existing first target station (FTS) with the remaining beam power available for the future second target station (STS). The project has installed seven superconducting radio-frequency (RF) cryomodules and supporting RF power systems to increase the beam energy by 30% to 1.3 GeV, and the beam current will be increased by 50%. The injection and extraction region of the accumulator ring are being upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. The first four cryomodules and supporting systems were commissioned in 2022-2023 and supported neutron production at 1.05 GeV, 1.7 MW with high reliability. The first-article 2 MW target was operated successfully for approximately 4400 MW-Hours over two run periods. The long outage began in August 2023 for installation of the remaining technical equipment and construction of the Ring-to-Target Beam Transport tunnel stub that will enable connection to the STS without interrupting operation of the FTS. The upgrade is proceeding on-schedule and on-budget, and resumption of neutron production for the user program is planned for July 2024.

Champion, Mark↗

Final Design and Analysis of the Superconducting Magnets for the Material Plasma Exposure Experiment

The Material Plasma Exposure eXperiment (MPEX), which has completed its final design, is a new linear plasma device to advance the understanding of plasma-material interactions through the generation and delivery of plasmas as they are expected in future fusion reactor divertors. MPEX will be a steady-state device to study high-fluence exposures of plasma-facing materials and components. The requirements for the magnetic field at the heating stages and the target make the application of superconducting coils necessary. The final designs for the superconducting magnets have been developed using three cryostat designs with warm bore diameters of 65 cm and 156 cm. The large bores are required to for other systems such as vacuum, water cooling, and RF power. There are 19 superconducting coils in MPEX that are contained in six cryostats. Although design, fabrication, and testing for the magnets as stand-alone units are straightforward, challenges will arise during the integration of the system. Various field profiles will be used during operation. The magnetic field where the electron cyclotron heating occurs needs to operate at both 1.25 and 2.50 T. Analyses that have been performed on the final design include designing the coils and determining operating currents to meet field requirements, forces between cryostats, the effects of coil and/or cryostat movement, and quench analysis. To ensure that the magnetic field requirements are met, a plan for monitoring the magnetic field at specified locations has been developed which includes the effect of coil and/or cryostat movement.

Burkhardt, Earle↗

Measurements of Magnetic Field Penetration of Materials for Superconducting Radiofrequency Cavities

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently high purity niobium is the material of choice for SRF cavities which have been optimized to operate near their theoretical field limits. This brings about the need for significant R&D efforts to develop next generation superconducting materials which could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate in a supercon- ductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements which are strongly influenced by the film orientation and shape and edge effects. The applied magnetic field is also needed to be parallel to the one side of the superconductor to resemble the magnetic field profile at the surface of the SRF cavities operating at fundamental accelerating mode. In this work we report the development of an experimental setup called Magnetic Field Penetration (MFP) magnetometer to measure the field of full flux penetration through bulk, thin films and multilayered superconductors. Our system combines a small superconducting solenoid which can generate the magnetic field up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the planner superconductor with 2 inch diameter. This setup was used to study alternative materials which could potentially outperform niobium, as well as SIS multilayer coatings on niobium.

Senevirathne, Iresha↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of enhanced superconducting properties in niobium cavities

Superconducting radio-frequency (SRF) niobium cavities are critical for modern particle accelerators, as well as for advancing superconducting quantum systems and enabling ultrasensitive searches for new physics. In this work, we report a systematic observation of an anomalous frequency dip in Nb cavities, which occurs at temperatures just below the critical temperature (𝑇𝑐 ), indicative of enhanced superconducting properties at 𝑇 ≪ 𝑇 𝑐 . The magnitude of this dip is strongly correlated with the rf surface resistance, impurity distribution near the surface, and 𝑇𝑐 . Additionally, we report measurements of the coherence peak in the ac conductivity of two Nb SRF cavities processed using distinct methods. By comparing recent theories developed to model this experimental data, we show that the frequency-dip feature, larger coherence peak height, and reduction in the temperature-dependent surface resistance with rf current occur at minimal but finite levels of disorder.

43 PARTICLE ACCELERATORS↗

Experiments On A Conduction Cooled Superconducting Radio Frequency Cavity With Field Emission Cathode

To achieve Ampere-class electron beam accelerators the pulse delivery rate need to be much higher than the typical photo injector repetition rate of the order of a few kilohertz. We propose here an injector which can, in principle, generate electron bunches at the same rate as the operating RF frequency. A conduction-cooled superconducting radio frequency (SRF) cavity operating in the CW mode and housing a field emission element at its region of high axial electric field can be a viable method of generating high-repetition-rate electron bunches. In this paper, we report the development and experiments on a conduction-cooled Nb3Sn cavity with a niobium rod intended as a field emitter support. The initial experiments demonstrate 0.4 MV/m average accelerating gradient, which is equivalent of peak gradient of 3.2 MV/m. The measured RF cavity quality factor is 1.4 x 10$^8$ slightly above our goal. The achieved field gradient is limited by the relatively low input RF power and by the poor coupling between the external power supply and the RF cavity. With ideal coupling the field gradient can be as high as 0.6 MV/m still below our goal of about 1 MV/m.

43 PARTICLE ACCELERATORS↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

Methods of controllable interstitial oxygen doping in niobium

A method for vacuum heat treating Nb, such as is used in superconducting radio frequency cavities, to engineer the interstitial oxygen profile with depth into the surface to conveniently optimize the low-temperature rf surface resistance of the material. An example application is heating of 1.3 GHz accelerating structures between 250-400° C. to achieve a very high quality factor of 5×1010 at 2.0 K. With data supplied by secondary ion mass spectrometry measurements, application of oxide decomposition and oxygen diffusion theory was applied to quantify previously unknown parameters crucial in achieving the oxygen alloy concentration profiles required to optimize the rf surface resistance. RF measurements of vacuum heat treated Nb superconducting radio frequency cavities confirmed the minimized surface resistance (higher Q0) previously expected only from 800° C. diffusive alloying with nitrogen.

Palczewski, Ari D.↗

Optimization of a traveling wave superconducting radiofrequency cavity for upgrading the International Linear Collider

The standing wave TESLA niobium-based superconducting radio frequency structure is limited to an accelerating gradient of about 50 MV/m by the critical rf magnetic field. To break through this barrier, we explore the option of niobium-based traveling wave (TW) structures. Optimization of TW structures was done considering experimentally known limiting electric and magnetic fields. It is shown that a TW structure can have an accelerating gradient above 70 MeV/m that is about 1.5 times higher than contemporary standing wave structures with the same critical magnetic field. The other benefit of TW structures shown is R/Q about 2 times higher than the TESLA structure that reduces the dynamic heat load by a factor of 2. A method is proposed how to make TW structures multipactor-free. Some design proposals are offered to facilitate fabrication. Further increase of the real-estate gradient (equivalent to 80 MV/m active gradient) is also possible by increasing the length of the accelerating structure because of higher group velocity and cell-to-cell coupling. Realization of this work opens paths to International Linear Collider energy upgrades beyond 1 to 3 TeV in competition with CLIC. The paper will discuss corresponding opportunities and challenges.

43 PARTICLE ACCELERATORS↗

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

Instabilities driven by the fundamental crabbing mode

The Electron Ion Collider (EIC) requires crab cavities to correct for crossing angle effects. These cavities produce a time varying horizontal kick that makes the collision head on in the center of mass frame of the bunches. This results in a luminosity that is very close to the the luminosity obtained without a crossing angle. Producing the kick requires a transverse RF field. This field requires a superconducting resonator and reasonable power levels require loaded quality factors of order a million. This results is a very large transverse impedance for the crabbing mode. The horizontal beta function is large and this, coupled with the large transverse impedance of the resonator can lead to strong instabilities. In the first section of the paper a simple model is used to describe the situation without feedback. There are large ranges of tune leading to strong instabilities in both the electron and hadron storage rings of the EIC. These estimates are confirmed with simulations. In the second section, RF feedback is used to reduce the apparent impedance of the crabbing mode. Simulating the actual feedback would require both a significant rewrite of the tracking code and a significant reduction in computational speed. Instead, the apparent impedance is fitted using one pole filters, which allows use of the existing simulation code. In the third section a transverse damping system is outlined.

43 PARTICLE ACCELERATORS↗

Microscopic examination of rf-cavity-quality niobium films through local nonlinear microwave response

The performance of superconducting radio-frequency (SRF) cavities is sometimes limited by local defects. To investigate the rf properties of these local defects, especially those that nucleate rf magnetic vortices, a near-field magnetic microwave microscope is employed. Local third-harmonic response ( P 3 f ) and its temperature dependence and rf power dependence are measured for one Nb / Cu film grown by direct current magnetron sputtering (DCMS) and six Nb / Cu films grown by high-power impulse magnetron sputtering (HiPIMS) with systematic variation of deposition conditions. Five out of the six HiPIMS Nb / Cu films show a strong third-harmonic response that is likely coming from rf vortex nucleation due to a low- T c surface defect with a transition temperature between 6.3 and 6.8 K, suggesting that this defect is a generic feature of air-exposed HiPIMS Nb / Cu films. A phenomenological model of surface-defect grain boundaries hosting a low- T c impurity phase is introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe-sample interaction to better understand the measured third-harmonic response. The simulation results show that the third-harmonic response of rf vortex nucleation caused by surface defects exhibits the same general features as the data, including peaks in third-harmonic response with temperature, and their shift and broadening with higher microwave amplitude. We find that the parameters of the phenomenological model (the density of surface defects that nucleate rf vortices and the depth an rf vortex travels through these surface defects) vary systematically with film deposition conditions. From the point of view of these two properties, the Nb / Cu film that is most effective at reducing the nucleation of rf vortices associated with surface defects can be identified. Published by the American Physical Society 2024

Wang, Chung-Yang (ORCID:0000000184299633)↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK

At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer which maintains sensitivity to 5 mK. A key component of this thermometer is an in situ radio frequency filter which is based on a modern rf absorption material. Here, we show that the use of such a filter is only effective when it is encased in the same rf-tight enclosure as the ruthenium oxide sensor. Our design delivers an attenuation level that is necessary to mitigate the effects of parasitic heating of a fraction of pW present in our circuit. Furthermore, we show that the likely origin of this parasitic heating is the black body radiation present within the experimental space of the refrigerator. We found that the equilibration time of the thermometer increases rapidly as the temperature is lowered; below 5 mK this thermometer becomes impractical because of the prohibitively long equilibration times.

47 OTHER INSTRUMENTATION↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

Machine protection system for coherent electron cooling experiment

The coherent electron cooling (CeC) experiment employs a 15 MeV electron beam with up to a few milliamperes current which is capable of destroying the vacuum equipment or intercepting beam diagnostics. The high-current beam can be delivered to two different dumps. RF systems include normal conducting and superconducting cavities which also require protection from abnormal conditions. In this paper, we describe in detail the design and operation of the machine protection system for the CeC accelerator.

43 PARTICLE ACCELERATORS↗