Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REMOVAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Assessing whole-sounder removal versus traditional control for reducing invasive wild pig ( Sus scrofa ) populations

Trapping is commonly used as the primary management tool in attempts to reduce invasive wild pigs (Sus scrofa), but traditional trapping techniques are often ineffective. However, recently developed traps permit the capture of entire social groups (sounders) of wild pigs, and the strategy of whole-sounder removal may achieve more effective control. Our objective was to experimentally compare traditional control (TC; primarily traditional trapping, but including hunting with dogs, and opportunistic shooting) and whole-sounder removal (WSR) strategies by assessing density reduction and removal rate after 1 and 2 years of treatment. After 1 year of trapping, average wild pig density on WSR units declined 53% and remained stable after the second year, whereas on TC units, pig density did not differ after trapping, although it declined 33% and remained stable after the second year of trapping. The median removal rate (percentage of uniquely marked pigs present at the beginning of each year that were removed) was 42.5% for WSR units and 0.0% for TC units during 2018 and were 29.6% from WSR units and 5.3% from TC units during 2019. WSR removal was more effective at reducing wild pig density than TC, but factors such as previous exposure of this population to traditional traps and the lack of barriers to recolonization from surrounding areas may have reduced WSR efficacy. WSR can effectively reduce wild pig density to a greater extent than TC, but managers should recognize the additional time and expense necessary for implementation.

Sus scrofa↗

Biomass Carbon Removal and Storage (BiCRS)

To achieve the ambitious net-zero emission goal by 2050, it is vital to explore practical approaches for removing carbon dioxide from the air. One promising method is Biomass Carbon Removal and Storage (BiCRS). BiCRS combines the natural ability of plants to convert carbon dioxide into biomass with human engineering to store the biomass, or derived products (char), belowground where it won't decompose. By securely storing these materials underground, we can trap the carbon dioxide absorbed by the plants during their growth, thus aiding in carbon removal from the atmosphere. BiCRS not only addresses carbon emissions but also has co-benefits such as wildfire risk reduction by utilizing forest residues. It is essential to establish best practices to ensure accurate measurements of net carbon dioxide removed by BiCRS for policymakers, businesses and communities. Presently, there is a lack of consistent methods for calculating these removals, considering variables like plant type, storage conditions, and conditions for converting the biomass to other products for storage like char. This project develops guidelines for monitoring and reporting BiCRS activities, offering a dependable framework for measuring carbon dioxide removal, enabling adoption of transparent BiCRS approaches for making significant contributions to reducing carbon dioxide levels in the atmosphere.

biomass carbon removal and storage↗

Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days) through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Importance of Slag Structure to Boron Removal from Silicon during the Refining Process: Insights from Raman and Nuclear Magnetic Resonance Spectroscopy Study

Slag structure plays an important role in determining the relative ease of boron removal from silicon. Correlation between slag structure and boron removal thermodynamics was experimentally studied by Raman and nuclear magnetic resonance (NMR) spectroscopy using CaO-SiO{sub 2}-Na{sub 2}O slags with different optical basicities (0.6 to 0.71). Optimization of slag depolymerization leads to efficient removal of boron. The extent of nonbridged oxygen content (NBO/T) and boron removal gradually increased with an increase in optical basicity from 0.6 to 0.66: B{sub 2}O{sub 3} derived from boron oxidation captured nonbridging oxygens of Q{sup 0}(Si), Q{sup 1}(Si), and Q{sup 2}(Si), and was incorporated into the silicate network in the form of Q{sup 3}(Si and B). When optical basicity increased to 0.71, NBO/T rapidly increased and boron removal decreased considerably. Quick depolymerization of Q{sup 3}(Si and B) deteriorated the stability of boron. Various structural forms of boron in the silicate network were successfully detected: the BO{sub 3} trihedrons {sup [3]}B-3Si, {sup [3]}B-2Si-1NBO, and BO{sub 3} (nonring), and the BO{sub 4} tetrahedrons BO{sub 4} (1B, 3Si) and BO{sub 4} (0B, 4Si). BO{sub 4} (1B, 3Si) was the main structure contributing to the increase of boron capacity; BO{sub 3} (nonring), detected under higher optical basicity conditions, may cause deterioration of boron removal by suppressing its oxidation.

36 MATERIALS SCIENCE↗

Passive decay heat removal system design for the integral inherent safety light water reactor (I 2 S-LWR)

The Integral, Inherently Safe Light Water Reactor (I 2 S-LWR) is an innovative Pressurized Water Reactor (PWR) concept being developed by a multi-institutional team led by Georgia Tech and in collaboration with Westinghouse, under the Department of Energy’s Nuclear Energy University Programs Integrated Research Projects (DOE NEUP IRP). The University of Michigan leads the design of the thermalhydraulic and passive safety systems, in collaboration with Westinghouse and Bringham Young University. The I 2 S-LWR features an integral primary system configuration and is more conducive to the implementation of inherent safety features by eliminating potential accidents. In this paper, a novel passive Decay Heat Removal System (DHRS), is presented, consisting of a primary loop, an intermediate loop and a cooling tower loop. This passive system is designed to remove the I 2 S-LWR decay heat in the case of emergency heat removal transients, without the need for external power or operator action. The proposed DHR uses atmosphere as ultimate heat sink, to achieve indefinite decay heat removal. In this paper, firstly, the design of primary and secondary DHRS heat exchangers is optimized. Then the DHR heat removal characteristics are studied using the best-estimate thermal hydraulic code RELAP5. In addition, CFD simulations have been performed in order to investigate the DRHS helical coil primary heat exchanger performance with different coil pipe arrangements, and optimize its design. The performance of the proposed DHRS concept is investigated in case of a Station Black-Out (SBO) scenario. Operation of two, three and four DHRS trains is studied respectively. The findings show that three out of four DHRS trains are sufficient to indefinitely remove the core decay heat successfully during a SBO, and keep the reactor in a safe state without the need of any other auxiliary active system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Selective phosphate removal with manganese oxide composite anion exchange membranes in membrane capacitive deionization

The discharge of excessive phosphorous into water bodies can lead to serious eutrophication threatening aquatic ecosystem. Membrane capacitive deionization (MCDI) is an effective platform for deionizing aqueous streams; however, conventional MCDI is unable to selectively remove targeted ions from a liquid mixture. Here, in this work, we fabricated manganese oxide composite anion exchange membranes (AEMs) for MCDI to enhance phosphate removal selectivity from sodium chloride-sodium dihydrogen phosphate (10:1 M ratio) aqueous mixtures. We systematically investigated several critical factors, such as constant current or voltage operation, applied voltage amount, process stream pH, and manganese oxide (Mn 2 O 3 ) content in the AEM, on phosphate removal efficiency and phosphate selectivity. A trade-off was observed between phosphate removal and selectivity when increasing the cell voltage. Under the best conditions, a MCDI unit with a 20 wt% Mn 2 O 3 composite AEM and a bipolar membrane facilitated high phosphate removal efficiency of ≥ 31.8 % and a phosphate over chloride selectivity of 1.1 while showing stability for at least 30 cycles. To help understand how Mn 2 O 3 composite AEM boosts phosphate selectivity, static electronic structure calculations were performed, and they revelated that hydrogen phosphate absorption on Mn 2 O 3 composite AEM was 314 kcal/mol more exothermic than that on pristine AEM while chloride adsorption on Mn 2 O 3 composite AEM was 2.2 kcal/mol less exothermic than that on a pristine AEM. Overall, this work presents an effective strategy for selectively removing phosphate from model wastewater solutions and the mechanistic understanding that governs ion selectivity in composite ion-exchange membranes used in MCDI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of nonaqueous phase liquid (NAPL) source zone architecture on mass removal mechanisms in strongly layered heterogeneous porous media during soil vapor extraction

An existing multiphase flow simulator was modified in order to determine the effects of four mechanisms on NAPL mass removal in a strongly layered heterogeneous vadose zone during soil vapor extraction (SVE): a) NAPL flow, b) diffusion and dispersion from low permeability zones, c) slow desorption from sediment grains, and d) rate-limited dissolution of trapped NAPL. The impact of water and NAPL saturation distribution, NAPL type (i.e., free, residual, or trapped) distribution, and spatial heterogeneity of the permeability field on these mechanisms were evaluated. Two different initial source zone architectures (one with and one without trapped NAPL) were considered and these architectures were used to evaluate seven different SVE scenarios. For all runs, slow diffusion from low permeability zones that gas flow bypassed was a dominant factor for diminished SVE effectiveness at later times. This effect was more significant at high water saturation due to the decrease of gas-phase relative permeability. Transverse dispersion contributed to fast NAPL mass removal from the low permeability layer in both source zone architectures, but longitudinal dispersion did not affect overall mass removal time. Both slow desorption from sediment grains and rate-limited mass transfer from trapped NAPL only marginally affected removal times. However, mass transfer from trapped NAPL did affect mass removal at late time, as well as the NAPL distribution. NAPL flow from low to high permeability zones contributed to faster mass removal from the low permeability layer, and this effect increased when water infiltration was eliminated. These simulations indicate that if trapped NAPL exists in heterogeneous porous media, mass transfer can be improved by delivering gas directly to zones with trapped NAPL and by lowering the water content, which increases the gas relative permeability and changes trapped NAPL to free NAPL.

54 ENVIRONMENTAL SCIENCES↗

Numerical and experimental investigation of DNAPL removal mechanisms in a layered porous medium by means of soil vapor extraction

The purpose of this work is to identify the mechanisms that govern the removal of carbon tetrachloride (CT) during soil vapor extraction (SVE) by comparing multiphase flow simulations with a detailed data set from a well-defined two-dimensional flow cell experiment. The flow cell was packed with two sandy soils including an embedded fine-grained sand layer. Gas concentrations at the outlet of the flow cell and 15 sampling ports inside the flow cell were measured during SVE. A dual-energy gamma radiation system was used to measure an initial NAPL saturation profile in a fine-grained sand layer. Imaging result from a dual-energy gamma radiation system with dyed CT mark along CT migration was used to construct the distribution of initial NAPL saturation in the flow cell for input to numerical simulations. Gas concentration results and photographs during SVE were compared to simulation results using a continuum-based multiphase flow simulator, STOMP (Subsurface Transport Over Multiple Phases). The measured effluent gas concentration decreased quickly at first, and then started to decrease gradually, resulting in long-term tailing. CT mass was removed quickly in coarse sand, followed by a slow removal from the fine-grained sand layer. An analytical solution for a one-dimensional advection and first-order volatilization model matched the tailing well with two fitting parameters. However, given detailed knowledge of the permeability field and initial NAPL distribution, we can predict the tailing and gas concentration profiles at sampling ports using equilibrium NAPL volatilization. NAPL flow occurs in the presence of free NAPL, and must be accounted for to accurately predict NAPL removal during the SVE experiment. The model prediction was accurate within the uncertainty of the measured or literature derived parameters (i.e., dispersivity and soil parameters). This study provides insights into the physical mechanisms of NAPL removal from a low permeability zone, and use of the local equilibrium assumption for NAPL volatilization during SVE. In addition, this study demonstrates that lack of detailed information regarding NAPL distribution and heterogeneity pattern lead overall NAPL removal to a kinetically controlled system at a 2-D flow cell scale.

54 ENVIRONMENTAL SCIENCES↗

Using MOF-74 for Hg{sup 2+} removal from ultra-low concentration aqueous solution

Mercury (Hg{sup 2+}) ions have very high toxicity and widely spread as environmental pollutants. At present, many efforts have been taken to remove the hazardous materials of mercury(II) by adsorption, and it is highly desirable to develop a novel adsorbent with high adsorptive capacities. However it is still a big challenge to remove the ultra-low-concentration mercury ions from water. In this paper, MOF-74-Zn is explored for such function, showing high removal rate of Hg(II) from water without any pretreatment, especially for the ultra-trace Hg(II) ions in the ppb magnitude with the removal rate reaching to 54.48%, 69.71%, 72.26% when the initial concentration of Hg(II) is 20ppb, 40ppb, 50ppb, respectively. - Graphical abstract: The absorption of mercury ions on MOF-74-Zn is due to somewhat weak interactions between MOF skeleton that is composed of carboxylate and hydroxy group and Hg2+ ions. - Highlights: • MOF-74-Zn shows high removal rate of Hg(II) from water without any pretreatment. • The MOF-74-Zn has a notable performance at ultra-low concentration of Hg(II). • MOF-74-Zn shows the potential for Hg(II) removal from industrial waste water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and performance study of MgFe{sub 2}O{sub 4}/metal–organic framework composite for rapid removal of organic dyes from water

In present study, a stable and magnetic metal-organic framework (MOF) material was synthesized by simple solvothermal method as adsorbent to rapid removal of two organic dyes, the Rhodamine B (RB) and Rhodamine 6G (Rh6G), in water samples. The prepared material showed great characteristics of large surface area (519.86 m{sup 2} g{sup −1}), excellent magnetic responsivity (35.00 emu g{sup −1}) and rapid removal (within 5 min). Maximum adsorption capacities of the magnetic material toward RB and Rh6G were up to 219.78 and 306.75 mg g{sup −1}, respectively. Adsorption kinetics suggested the adsorption process met the pseudo-second-order kinetic model. The prepared material could be reused at least 10 times by washing with acetonitrile solution, the relative standard deviation (RSD) of these ten cycles removal efficiency was 4.8%. In conclusion, good chemical inertness, a mechanical/water stability and super-hydrophilicity feature made this MOF a promising adsorbent for targets removal from environmental water sample. - Graphical abstract: The magnetic MgFe{sub 2}O{sub 4}/metal–organic framework with ultra-high adsorption capacity towards rhodamine dyes showed rapid removal efficiency (within 5 min) and good reusability (at least 10 times). Display Omitted - Highlights: • A stable and magnetic MgFe{sub 2}O{sub 4}@MOF material was synthesized as adsorbent to rapid removal of organic dyes. • The material in this article could rapidly sequestered rhodamine dyes within 5 min. • The maximum adsorption capacities of the magnetic material were high.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of hydroxyl groups from Er{sup 3+}/Yb{sup 3+} codoped flurotellurite glasses

Highlights: • We propose a simple and safe method for an efficient removal of hydroxyl groups from Er{sup 3+}/Yb{sup 3+} doped fluorotellurite glasses. • We have shown that using a convenient amount of BaF{sub 2} as drying agent helped to remove partially hydroxyl groups. • For an efficient removal of hydroxyl groups, we have subjected the glasses to an additional heat-treatment in two steps. • The obtained results revealed an efficient removal of water from the glasses which manifested itself in a drastic reduction of the concentration of hydroxyl groups and a significant increase of Er{sup 3+} emission. • This study showed that the addition BaF{sub 2} and the heat treatment process might be a veritable alternative for drying tellurite glasses. - Abstract: In this work, we present a safe and relatively simple procedure to eliminate hydroxyl groups from Er{sup 3+} and Yb{sup 3+} codoped new flurotellurite glasses. It was shown that adding a convenient amount of BaF{sub 2} as drying agent reduced the absorption coefficient and the concentration of hydroxyl groups inside the glass samples. However, to remove efficiently water from the glasses, it was necessary to subject the samples to supplementary heat treatment in two steps. A drastic decrease of the density of hydroxyl groups accompanied with a significant enhancement of the erbium emission was observed after the heat-treatment procedure. The obtained results showed that this method might be a veritable alternative to obtain nearly water free tellurite glasses suitable for many optical devices with small sizes or thickness. However, for a good use of this procedure, we tried to elucidate what has happened at the microscopic scale for the glass taking as a guide the available explanations dealing with the removal of water from silica-based glasses.

36 MATERIALS SCIENCE↗

Mainstream nitrogen removal from low temperature and low ammonium strength municipal wastewater using hydrogel-encapsulated comammox and anammox

Application of partial nitritation (PN)-anammox to mainstream wastewater treatment faces challenges in low water temperature and low ammonium strength. In this study, a continuous flow PN-anammox reactor with hydrogel-encapsulated comammox and anammox was designed and operated for nitrogen removal from mainstream wastewater with low temperature. Long-term operation with synthetic and real wastewater as the feed demonstrated nearly complete ammonium and total inorganic nitrogen (TIN) removal by the reactor at temperatures as low as 10 °C. A significantly decreased nitrogen removal performance and biomass activity was observed in the reactor at 4 °C before a selective heating strategy was employed. A novel heating technology using radiation to heat carbon black co-encapsulated in the hydrogel matrix with biomass was used to selectively heat biomass but not water in the treatment system. This selective heating technology enabled nearly complete ammonium removal and 89.4 ± 4.3 % TIN removal at influent temperature of 4 °C and reactor temperature 5 °C. Activity tests suggested selective heating brought the biomass activity at influent temperatures of 4 °C and reactor temperature 5 °C to a level comparable to that at 10 °C. Comammox and anammox were consistently present in the system and spatially organized in the hydrogel beads as revealed by qPCR and fluorescence in-situ hybridization (FISH). The abundance of comammox largely decreased by 3 orders of magnitude during the operation at 4 °C, and rapidly recovered after the application of selective heating. The anammox-comammox technology tested in this study essentially enabled mainstream shortcut nitrogen removal, and the selective heating ensured good performance of the technology at temperature as low as 5 °C.

54 ENVIRONMENTAL SCIENCES↗

Removal of long-lived {sup 222}Rn daughters by electropolishing thin layers of stainless steel

Long-lived alpha and beta emitters in the {sup 222}Rn decay chain on detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay. Removal of tens of microns of material via electropolishing has been shown to be effective at removing radon daughters implanted into material surfaces. Some applications, however, require the removal of uniform and significantly smaller thicknesses. Here, we demonstrate that electropolishing < 1 μm from stainless-steel plates reduces the contamination efficiently, by a factor > 100. Examination of electropolished wires with a scanning electron microscope confirms that the thickness removed is reproducible and reasonably uniform. Together, these tests demonstrate the effectiveness of removal of radon daughters for a proposed low-radiation, multi-wire proportional chamber (the BetaCage), without compromising the screener’s energy resolution. More generally, electropolishing thin layers of stainless steel may effectively remove radon daughters without compromising precision-machined parts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric methane removal: a research agenda

Atmospheric methane removal (e.g. in situ methane oxidation to carbon dioxide) may be needed to offset continued methane release and limit the global warming contribution of this potent greenhouse gas. Because mitigating most anthropogenic emissions of methane is uncertain this century, and sudden methane releases from the Arctic or elsewhere cannot be excluded, technologies for methane removal or oxidation may be required. Carbon dioxide removal has an increasingly well-established research agenda and technological foundation. No similar framework exists for methane removal. We believe that a research agenda for negative methane emissions—‘removal' or atmospheric methane oxidation—is needed. We outline some considerations for such an agenda here, including a proposed Methane Removal Model Intercomparison Project (MR-MIP). This article is part of a discussion meeting issue 'Rising methane: is warming feeding warming? (part 1)'.

54 ENVIRONMENTAL SCIENCES↗

A novel multifunctional energy system (MES) for CO{sub 2} removal with zero energy penalty - article no. 021401

This paper proposes a novel, multifunctional energy system (MES), in which hydrogen and electricity are cogenerated and about 90% of CO{sub 2} is removed. By integrating the methane steam reforming reaction and combustion of coal, the natural gas and coal are utilized synthetically, and coal is burned to provide high-temperature thermal energy to the methane steam reforming reaction. Afterwards, the resulting syngas enters a pressure swing adsorption (PSA) unit to separate about 70% of hydrogen, thereby significantly increasing the concentration of carbon dioxide from nearly 20% to 43% in the PSA tail gas. As a result, the overall efficiency of the new system becomes 63.2%. Compared to a conventional natural gas-based hydrogen plant and a coal-firing steam power plant without CO{sub 2} removal (the overall efficiency of the two systems is 63.0%), the energy penalty for CO{sub 2} removal in the new system is almost totally avoided. Based on the graphical exergy analysis, we propose that the integration of synthetic utilization of fossil fuel (natural gas and coal) and the CO{sub 2} removal process plays a significant role in zero energy penalty for CO{sub 2} removal and its liquefaction in the MES. The result obtained here provides a new approach for CO{sub 2} removal with zero or low thermal efficiency reduction (energy penalty) within an energy system.

20 FOSSIL-FUELED POWER PLANTS↗

Atomic layer etching removal of damaged layers in a contact hole for low sheet resistance

A damaged layer remains on silicon substrates after high-aspect-ratio contact (HARC) etching when using a fluorocarbon gas. Atomic layer etching (ALET) is a technique that can be applied to remove the damaged layer of silicon, removing about 1.36 Å per etch cycle. The characteristics of contact damage removal by ALET are investigated and compared with the conventional damage removal technique of low-power CF{sub 4} plasma etching. The low-power CF{sub 4} plasma etching technique not only has inadequate etch depth control, but also introduces secondary damage by implanting impurities about 25 Å into the contact bottom of the silicon surface. However, ALET allows contact damage to be removed effectively without introducing secondary damage to the substrate, and with precision etch depth control at the angstrom scale. When ALET is applied subsequent to low-power CF{sub 4} plasma etching, the fluorine- and carbon-damaged silicon is effectively removed in about 10 cycles. The sheet resistance of HARC etched silicon decreases from 142 to 137 Ω/□ after using low-power CF{sub 4} plasma etching, and subsequent ALET treatment further decreases the sheet resistance to 129 Ω/□, which is close to the reference value of 124 Ω/□.

36 MATERIALS SCIENCE↗

APPLICATION OF VACUUM SALT DISTILLATION TECHNOLOGY FOR THE REMOVAL OF FLUORIDE

Vacuum distillation of chloride salts from plutonium oxide (PuO{sub 2}) and simulant PuO{sub 2} has been previously demonstrated at Department of Energy (DOE) sites using kilogram quantities of chloride salt. The apparatus for vacuum distillation contains a zone heated using a furnace and a zone actively cooled using either recirculated water or compressed air. During a vacuum distillation operation, a sample boat containing the feed material is placed into the apparatus while it is cool, and the system is sealed. The system is evacuated using a vacuum pump. Once a sufficient vacuum is attained, heating begins. Volatile salts distill from the heated zone to the cooled zone where they condense, leaving behind the non-volatile materials in the feed boat. The application of vacuum salt distillation (VSD) is of interest to the HB-Line Facility and the MOX Fuel Fabrication Facility (MFFF) at the Savannah River Site (SRS). Both facilities are involved in efforts to disposition excess fissile materials. Many of these materials contain chloride and fluoride salt concentrations which make them unsuitable for dissolution without prior removal of the chloride and fluoride salts. Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and HB-Line designed, developed, tested, and successfully deployed a system for the distillation of chloride salts. Subsequent efforts are attempting to adapt the technology for the removal of fluoride. Fluoride salts of interest are less-volatile than the corresponding chloride salts. Consequently, an alternate approach is required for the removal of fluoride without significantly increasing the operating temperature. HB-Line Engineering requested SRNL to evaluate and demonstrate the feasibility of an alternate approach using both non-radioactive simulants and plutonium-bearing materials. Whereas the earlier developments targeted the removal of sodium chloride (NaCl) and potassium chloride (KCl), the current activities are concerned with the removal of the halide ions associated with plutonium trifluoride (PuF{sub 3}), plutonium tetrafluoride (PuF{sub 4}), calcium fluoride (CaF{sub 2}), and calcium chloride (CaCl{sub 2}). This report discusses non-radioactive testing of small-scale and pilot-scale systems and radioactive testing of a small-scale system. Experiments focused on demonstrating the chemistry for halide removal and addressing the primary engineering questions associated with a change in the process chemistry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life of 99 Tc, effective management of 99 Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99 Tc during the vitrification process. Removal of 99 Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99 Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99 Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 - ). Perrhenate (ReO 4 - ) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of 291 mL/g at a 100:1 phase ratio. This slightly exceeds the computer-modeled equilibrium distribution. The modeling agreed well with the experimental data for perrhenate removal with minor adjustments. Predicted breakthrough performance was on average within about 20% of measured values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗