Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A large area detector for neutrons between 2 and 100 MeV

A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg.

Grannan, R. T.↗

A numerical hydrodynamic study of coalescence in head-on collisions of identical stars.

The specific results reported refer to head-on collisions between identical polytropes of index 3 having solar mass and radius. If the polytropes were initially at rest at infinity, then about 5% of the combined mass is lost by ejection following collision. The volatilized mass fraction rises to about 18% for an initial relative collision velocity of 1000 km/sec at infinite separation, and to about 60% for the 2000 km/sec case. Since the initial kinetic and gravitational energies balance for a relative velocity of 1512 km/sec at infinity, it may be seen that net coalescence persists to velocities somewhat in excess of this figure. Mass ejection takes place in two ways simultaneously: (1) by a rapid sideward expulsion of fluid in a massive lateral sheet normal to the collision axis, and (2) as a result of two recoil shocks which lead momentum flows backward along this axis. The lateral effect has similarities to the expansion of gas into a vacuum i.e., shocks are not involved. However, the ejection of material from the rear colliding hemisphere due to the recoil shocks predominates at low collision velocities. As the velocity increases, both effects strengthen, but the lateral expulsion intensifies more rapidly than the recoil shocks.

Seidl, F. G. P.↗

Proton-deuteron double scattering

A simple but accurate form for the proton-deuteron elastic double scattering amplitude, which includes both projectile and target recoil motion and is applicable at all momentum transfer, is derived by taking advantage of the restricted range of Fermi momentum allowed by the deuteron wave function. This amplitude can be directly compared to approximations which have neglected target recoil or are limited to small momentum transfer; the target recoil and large momentum transfer effects are evaluated explicitly within the context of a Gaussian model.

Wilson, J. W.↗

Stoichiometric disturbances in compound semiconductors due to ion implantation

A method is developed to calculate the depth distribution of the local stoichiometric disturbance (SD) resulting from ion implantation in binary-compound substrates. The calculation includes first-order recoils considering projected range straggle of projectiles and recoils and lateral straggle of recoils. The method uses tabulated final-range statistics to infer the projectile range distributions at intermediate energies. This approach greatly simplifies the calculation with little compromise on accuracy as compared to existing procedures. As an illustration, the SD profile is calculated for implantation of boron, silicon, and aluminum in silicon carbide. The results for the latter case suggest that the SD may be responsible for otherwise unexplained distortions in the annealed aluminum profile. A comparison with calculations by other investigators using the Boltzmann transport equation shows good agreement.

Avila, R. E.↗

Energy deposition at the bone-tissue interface from nuclear fragments produced by high-energy nucleons

The transport of nuclear fragmentation recoils produced by high-energy nucleons in the region of the bone-tissue interface is considered. Results for the different flux and absorbed dose for recoils produced by 1 GeV protons are presented in a bidirectional transport model. The energy deposition in marrow cavities is seen to be enhanced by recoils produced in bone. Approximate analytic formulae for absorbed dose near the interface region are also presented for a simplified range-energy model.

Cucinotta, Francis A.↗

The Ptolemaic gamma-ray burst universe

The BATSE experiment on GRO has demonstrated the isotropic arrival directions and flat log N vs log S of cosmic gamma-ray bursts. These data are best explained if the burst sources are distributed throughout an extended spherical galactic halo, as previously suggested by Jennings. The halo's radius is at least 40 kpc, and probably is more than 100 kpc. I consider possible origins of this halo, including primordial formation and neutron stars recoiling from their birthplaces in the galactic disk. A simple geometrical model leads to a predicted relation between the dipole and quadrupole anisotropy. I suggest that neutron stars born with low recoil become millisecond pulsars, while those born with high recoil become the sources of gamma-ray bursts; these populations are nearly disjoint. Quiescent counterparts of gamma-ray bursts are predicted to be undetectably faint.

Katz, J. I.↗

Distribution of energy in polymers due to incident electrons and protons

The recoil spectrum of nuclei in polymers for incident protons below 10 MeV in energy is calculated by using the Rutherford cross-section with screening corrections. Employing the work of McKinley and Feshbach on the Coulomb scattering of relativistic electrons by nuclei, the recoil spectrum of the nuclei is also calculated for electron energies varying from threshold to 10 MeV. The partitioning of energy between electronic excitation and ionization and nuclear recoil is then studied to search for possible difference in polymer radiation response as a function of radiation energy and type.

NASA Discipline Number 22-70↗

Computational Transport Modeling of High-Energy Neutrons Found in the Space Environment

The high charge and high energy (HZE) particle radiation environment in space interacts with spacecraft materials and the human body to create a population of neutrons encompassing a broad kinetic energy spectrum. As an HZE ion penetrates matter, there is an increasing chance of fragmentation as penetration depth increases. When an ion fragments, secondary neutrons are released with velocities up to that of the primary ion, giving some neutrons very long penetration ranges. These secondary neutrons have a high relative biological effectiveness, are difficult to effectively shield, and can cause more biological damage than the primary ions in some scenarios. Ground-based irradiation experiments that simulate the space radiation environment must account for this spectrum of neutrons. Using the Particle and Heavy Ion Transport Code System (PHITS), it is possible to simulate a neutron environment that is characteristic of that found in spaceflight. Considering neutron dosimetry, the focus lies on the broad spectrum of recoil protons that are produced in biological targets. In a biological target, dose at a certain penetration depth is primarily dependent upon recoil proton tracks. The PHITS code can be used to simulate a broad-energy neutron spectrum traversing biological targets, and it account for the recoil particle population. This project focuses on modeling a neutron beamline irradiation scenario for determining dose at increasing depth in water targets. Energy-deposition events and particle fluence can be simulated by establishing cross-sectional scoring routines at different depths in a target. This type of model is useful for correlating theoretical data with actual beamline radiobiology experiments. Other work exposed human fibroblast cells to a high-energy neutron source to study micronuclei induction in cells at increasing depth behind water shielding. Those findings provide supporting data describing dose vs. depth across a water-equivalent medium. This poster presents PHITS data suggesting an increase in dose, up to roughly 10 cm depth, followed by a continual decrease as neutrons come to a stop in the target.

Cox, Brad↗

Elucidating the effect of preheating temperature on melt pool morphology variation in Inconel 718 laser powder bed fusion via simulation and experiment

In laser powder bed fusion (L-PBF) additive manufacturing, the mechanical performance, microstructure and defects of fabricated parts are closely associated with the melt pool morphology, e.g., its dimension and shape through the building process. Past studies have largely focused on how the process parameters such as laser power and scan speed affect melt pool characteristics. In this study, the melt pool morphology variation as a function of preheating temperature in the conduction, transition, and keyhole regimes and the underlying mechanisms in each regime are investigated through ex-situ sample characterization and computation thermal fluid dynamics (CtFD) simulation. Single tracks with different combinations of laser power and scan speed are deposited on an Inconel 718 bare plate preheated to a temperature range of 100–500 °C in the experiment. Significant changes are observed in melt pool morphology as a function of preheating temperature from optical measurements of melt track cross sections. The depth of melt pool in the three regimes increases monotonically with preheating temperature, e.g., at 500 °C, the experimental melt pool depth is increased by 49% in conduction regime, 34% in transition regime and 33% in keyhole regime, respectively, while the variation of melt pool width in each regime does not all follow an increasing trend but depends on the melt pool regimes. Melt pool width variation in the conduction and transition regimes is found to depend on the enhanced heat conduction directly related to temperature dependent thermal properties. Through validated CtFD simulations, it is found that in the keyhole regime the evaporation mass, recoil pressure, and laser drilling effect is enhanced with higher preheating temperature, which gives rise to a deeper melt pool. The simulations also reveal that preheating temperature significantly elongates the melt track length due to the increased flow rate and strong recoil pressure that accelerates the backward flow.

36 MATERIALS SCIENCE↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-standard neutrino interactions in light mediator models at reactor experiments

Compared to other neutrino sources, the huge anti-neutrino fluxes at nuclear reactor based experiments empower us to derive stronger bounds on non-standard interactions of neutrinos with electrons mediated by light scalar/vector mediators. At neutrino energy around 200 keV reactor anti-neutrino flux is at least an order of magnitude larger compared to the solar flux. The atomic and crystal form factors of the detector materials related to the details of the atomic structure becomes relevant at this energy scale as the momentum transfers would be small. Non-standard neutrino-electron interaction mediated by light scalar/vector mediator arises naturally in many low-scale models. We also propose one such new model with a light scalar mediator. Here, we investigate the parameter space of such low-scale models in reactor based neutrino experiments with low threshold Ge and Si detectors, and find the prospect of probing/ruling out the relevant parameter space by finding the projected sensitivity at 90% confidence level by performing a $χ$ 2 -analysis. We find that a detector capable of discriminating between electron recoil and nuclear recoil signal down to a very low threshold such as 5 eV placed in reactor based experiment would be able to probe a larger region in parameter space compared to the previously explored region. A Ge (Si) detector with 10 kg-yr exposure and 1 MW reactor anti-neutrino flux would be able to probe the scalar and vector mediators with masses below 1 keV for coupling products $\sqrt{g_vg_e}$ ~ 1 × 10 -6 (9.5 × 10 -7 ) and 1 × 10 -7 (8 × 10 -8 ), respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the top-quark mass using decays with a J/ψ meson at s=13 TeV with the ATLAS detector

The top-quark mass is measured using top-quark decays producing an isolated lepton and J/ψ meson reconstructed in its μ+μ− decay mode. The data sample was recorded with the ATLAS detector in proton-proton collisions at a centre-of-mass energy of s=13$$ \sqrt{s}=13 $$ TeV during Run 2 of the Large Hadron Collider, corresponding to an integrated luminosity of 140 fb−1. The measurement is based on the invariant mass m(ℓμ+μ−) of the system made of the isolated lepton ℓ from the W boson decay and the non-isolated μ+μ− pair from a J/ψ decay of a b-hadron, exploiting its sensitivity to the top-quark mass. An unbinned maximum-likelihood fit to the m(ℓμ+μ−) distribution is performed to extract the top-quark mass. The top-quark mass is measured to be mtop = 172.17 ± 0.80 (stat) ± 0.81 (syst) ± 1.07 (recoil) GeV, with a total uncertainty of 1.56 GeV. The third uncertainty arises from changing the dipole parton shower gluon-recoil scheme used in top-quark decays.

Aad, G↗

Implications of the XENON1T excess on the dark matter interpretation

The dark matter interpretation for a recent observation of excessive electron recoil events at the XENON1T detector seems challenging because its velocity is not large enough to give rise to recoiling electrons of O(keV). Fast-moving or boosted dark matter scenarios are receiving attention as a remedy for this issue, rendering the dark matter interpretation a possibility to explain the anomaly. We investigate various scenarios where such dark matter of spin 0 and 1/2 interacts with electrons via an exchange of vector, axial-vector, pseudo-scalar, or scalar mediators. We find parameter values not only to reproduce the excess but to be consistent with existing bounds. Our study suggests that the scales of mass and coupling parameters preferred by the excess can be mostly affected by the type of mediator, and that significantly boosted dark matter can explain the excess depending on the mediator type and its mass choice. The method proposed in this work is general, and hence readily applicable to the interpretation of observed data in the dark matter direct detection experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the top-quark mass using a leptonic invariant mass in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A measurement of the top-quark mass ($m_t$) in the $t\overline{t}$ → lepton+jets channel is presented, with an experimental technique which exploits semileptonic decays of $b$-hadrons produced in the top-quark decay chain. The distribution of the invariant mass $m_{{\ell}µ}$ of the lepton, $\ell$ (with $\ell$ = $e, µ$), from the $W$-boson decay and the muon, $µ$, originating from the b-hadron decay is reconstructed, and a binned-template profile likelihood fit is performed to extract $m_t$. The measurement is based on data corresponding to an integrated luminosity of 36.1 fb –1 of $\sqrt{s}$ = 13 TeV $pp$ collisions provided by the Large Hadron Collider and recorded by the ATLAS detector. The measured value of the top-quark mass is $m_t$ = 174.41 ± 0.39 (stat.) ± 0.66 (syst.) ± 0.25 (recoil) GeV, where the third uncertainty arises from changing the Pythia8 parton shower gluon-recoil scheme, used in top-quark decays, to a recently developed setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadronic mono- W ' probes of dark matter at colliders

Particle collisions at the energy frontier can probe the nature of invisible dark matter via production in association with recoiling visible objects. We propose a new potential production mode, in which dark matter is produced by the decay of a heavy dark Higgs boson radiated from a heavy W' boson. In such a model, motivated by left-right symmetric theories, dark matter would not be pair produced in association with other recoiling objects due to its lack of direct coupling to quarks or gluons. We study the hadronic decay mode via W' → tb and estimate the LHC exclusion sensitivity at 95% confidence level to be 10 2 - 10 5 fb for W' boson masses between 250 and 1750 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision inclusive Higgs physics at e+e- colliders with tracking detectors and without calorimetry

A primary goal of a future e + e - collider program will be the precision measurement of Higgs boson properties. For practical reasons it is of interest to determine the minimal set of detector specifications required to reach this and other scientific goals. Here we investigate the precision obtainable for the e + e - Zh μ + μ - X inclusive cross section and the Higgs boson mass using the di-muon recoil method, considering a detector that has only an inner tracking system within a solenoidal magnetic field, surrounded by many nuclear interaction lengths of absorbing material, and an outer muon identification system. We find that the sensitivity achievable in these measurements with such a tracking detector is only marginally reduced compared to that expected for a general purpose detector with additional electromagnetic and hadronic calorimeter systems. The difference results mainly from multi-photon backgrounds that are not as easily rejected with tracking detectors. We also comment on the prospects for an analogous measurement of the e + e - → Zh → e + e - X inclusive cross section. Finally, we study searches for light scalars utilizing the di-muon recoil method, estimating the projected reach with a tracking or general purpose detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systematics in the XENON1T data: The 15-keV anti-axion

The XENON1T collaboration Aprile et al. [2020] has found an excess of electron recoil events in their Science Run 1 data below ~7 keV with a spectral shape consistent with that expected from a solar-axion-induced signal. The claimed statistical significance of the solar-axion model over the null hypothesis is 3.5σ. In this work we provide suggestive evidence for mismodeling in the electron recoil data that may decrease the local significance of the axion model. To reach this conclusion, we search for a signal with the spectral template of the solar axion model, but shifted to higher (unphysical) energies above ~7 keV. We find that the distribution of significances found from this side-band analysis does not follow the expected chi-square distribution. For example, we find a high-significance feature in the data, with a global $p$-value $p≈0.026$, when the solar axion model is shifted upwards in energy by ~15 keV and allowed to have a negative normalization. We argue that such statistical tests, if performed a priori, provide a data-driven way to test and potentially account for systematic uncertainties on the background model in low-threshold dark matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗