Neural network assisted analysis of bimetallic nanocatalysts using X-ray absorption near edge structure spectroscopy
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In situ x-ray absorption spectroscopy (XAS) provides element specific characterization of both crystalline and amorphous phases and enables direct correlations between electrochemical performance and structural characteristics of cathode and anode materials. In situ XAS measurements are very demanding to the design of the experimental setup. We have developed the sample chamber that provides electrical connectivity and inert atmosphere for the operating electrochemical cells and also accounts for x-ray interactions with chamber and the cell materials. The design of the sample chamber for in situ measurements is presented along with the example XAS spectra from the anode materials in operating pouch cells at Zn and Sn K-edges measured.in fluorescence and transmission modes respectively.
We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.
Abstract not provided
After the successful operation of the Free Electron Laser in Hamburg (FLASH) and the Linac Coherent Light Source (LCLS), soft and hard x-ray free electron lasers (FELs) are being built, designed, or proposed at many accelerator laboratories. Acceleration employing lower frequency rf cavities, ranging from L-band to C-band, is usually adopted in these designs. In the first stage bunch compression, higher-frequency harmonic rf system is employed to linearize the beam's longitudinal phase space, which is nonlinearly chirped during the lower frequency rf acceleration process. In this paper, a hard x-ray FEL design using an all X-band accelerator at 11.424 GHz (from photocathode rf gun to linac end) is presented, without the assistance of any harmonic rf linearization. It achieves LCLS-like performance at low charge using X-band linac drivers, which is more versatile, efficient, and compact than ones using S-band or C-band rf technology. It employs initially 42 microns long (rms), low-charge (10 pC) electron bunches from an X-band photoinjector. An overall bunch compression ratio of roughly 100 times is proposed in a two stage bunch compressor system. The start-to-end macroparticle 3D simulation employing several computer codes is presented in this paper, where space charge, wakefields, and incoherent and coherent synchrotron radiation effects are included. Employing an undulator with a short period of 1.5 cm, a Genesis FEL simulation shows successful lasing at a wavelength of 0.15 nm with a pulse length of 2 fs and a power saturation length as short as 20 meters, which is equivalent to LCLS low-charge mode. Its overall length of both accelerators and undulators is 180 meters (much shorter than the effective LCLS overall length of 1230 meters, including an accelerator length of 1100 meters and an undulator length of 130 meters), which makes it possible to be built in places where only limited space is available.
The detection sensitivity of synchrotron-based X-ray techniques has been largely improved due to the ever-increasing source brightness, which has significantly advanced ex situ and in situ research for energy materials such as lithium-ion batteries. However, the strong beam–material interaction arising from the high beam flux can substantially modify the material structure. The beam-induced parasitic effect inevitably interferes with the intrinsic material property, making the interpretation of the experimental results difficult and requiring comprehensive assessments. Here, we present a quantitative study of the beam effect on an electrode material Ag 2 VO 2 PO 4 using four different X-ray characterization methods with different radiation dose rates. The material system exhibits interesting and reversible radiation-induced thermal and chemical reactions, further evaluated under electron microscopy to illustrate the underlying mechanism. Further, the work will provide a guideline for using synchrotron X-rays to distinguish the intrinsic behavior from extrinsic structure change of materials induced by X-rays.
Abstract Over the past decades, zinc oxide semiconductor and its derivatives have been extensively developed because of its optoelectronic properties. Since ZnO is an intrinsic n-type semiconductor, how to synthesize high-quality p-type ZnO semiconductors and investigate their optoelectronic properties and local chemical structures are important and necessary. In this article, two studies of synthesizing both undoped and phosphorus-doped ZnO nanostructures by hydrothermal method and chemical vapor deposition (CVD) technique are presented. Scanning electron microscopy (SEM) and laboratory X-ray diffraction (XRD) are used to track the surface morphology and the crystalline structure of both undoped and phosphorus doped ZnO nanostructures, respectively. X-ray absorption near edge structures (XANES), X-ray emission spectroscopy (XES) and X-ray excited optical luminescence (XEOL) are also used to determine the local chemical information of both undoped and phosphorus-doped ZnO nano/microstructures such as local symmetry and optical properties. It is found that the phosphorus is successfully doped into the surface of ZnO and substituted the Zn. The phosphorus-doped ZnO products have better crystallinity and less oxygen vacancies on the surface. These two are correlated as one leads to the other. The XEOL results suggest that the average bandgap for undoped and phosphorus doped ZnO is the same, 3.24 eV. The second derivative of the absorption-emission spectra yields the fundamental bandgap for undoped ZnO and phosphorus-doped ZnO is 3.25 eV. The implication of this observation is discussed.
Observations and theoretical models of X-ray/gamma ray spectra of radio quiet Seyfert galaxies and Galactic black hole candidates are reviewed. The spectra from these objects share the following characteristics: an underlying power law with a high energy cutoff above 200 keV; a Compton reflection component with a Fe K alpha line, and a low energy absorption by intervening cold matter. The X-ray energy spectral index, alpha, is typically in the range between 0.8 and 1 in Seyfert spectra, and that of the hard state spectra of the black hole candidates Cygnus X-1 and GX 339-4 is typically between 0.6 and 0.8. The Compton reflection component corresponds with cold matter covering a solid angle of between 0.8pi and 2pi as seen from the X-ray source. The broadband spectra of both classes of sources are well fitted by Compton upscattering of soft photons in thermal plasma. The fits yield a thermal plasma temperature of 100 keV and the Thomson optical depth of 1. All the spectra presented are cut off before the electron rest energy 511 keV, indicating that electron/positron pair production is an important process.
A furnace with a water-cooled outside shell has been assembled to do in situ x-ray diffraction (XRD), small angle x-ray scattering (SAXS), and x-ray absorption fine structure (XAFS) experiments. The details of the furnace are described in this paper. The in situ XRD, SAXS, and XAFS experiments during the heating process demonstrate that the available temperature range of this furnace is from room temperature to 1200 K with a temperature accuracy of {+-}0.1 K. By using this furnace, in situ XRD, SAXS, and XAFS experimental techniques with temperature change can be easily combined together.
X-ray diffraction measurements of liquid water are reported at pressures up to 360 MPa corresponding to a density of 0.0373 molecules per Å{sup 3}. The measurements were conducted at a spatial resolution corresponding to Q{sub max} = 16 Å{sup −1}. The method of data analysis and measurement in this study follows the earlier benchmark results reported for water under ambient conditions having a density of 0.0333 molecules per Å{sup 3} and Q{sub max} = 20 Å{sup −1} [J. Chem. Phys. 138, 074506 (2013)] and at 70 °C having a density of 0.0327 molecules per Å{sup 3} and Q{sub max} = 20 Å{sup −1} [J. Chem. Phys. 141, 214507 (2014)]. The structure of water is very different at these three different T and P state points and thus they provide the basis for evaluating the fidelity of molecular simulation. Measurements show that at 360 MPa, the 4 waters residing in the region between 2.3 and 3 Å are nearly unchanged: the peak position, shape, and coordination number are nearly identical to their values under ambient conditions. However, in the region above 3 Å, large structural changes occur with the collapse of the well-defined 2nd shell and shifting of higher shells to shorter distances. The measured structure is compared to simulated structure using intermolecular potentials described by both first-principles methods (revPBE-D3) and classical potentials (TIP4P/2005, MB-pol, and mW). The DFT-based, revPBE-D3, method and the many-body empirical potential model, MB-pol, provide the best overall representation of the ambient, high-temperature, and high-pressure data. The revPBE-D3, MB-pol, and the TIP4P/2005 models capture the densification mechanism, whereby the non-bonded 5th nearest neighbor molecule, which partially encroaches the 1st shell at ambient pressure, is pushed further into the local tetrahedral arrangement at higher pressures by the more distant molecules filling the void space in the network between the 1st and 2nd shells.
High-irradiance short-pulse lasers incident on solid density thin foils provide high-energy, picosecond-duration, and monochromatic K{sub {alpha}} x-ray sources, but with limited conversion efficiency {epsilon} of laser energy into K{sub {alpha}} x-ray energy. A novel two-stage target concept is proposed that utilizes ultrahigh-contrast laser interactions with primary ultrathin foils in order to efficiently generate and transport in large quantities only the most effective K{sub {alpha}-}producing high-energy electrons into secondary x-ray converter foils. Benchmarked simulations with no free numerical parameters indicate an {epsilon} enhancement greater than tenfold over conventional single targets may be possible.
Here, new evidence is provided to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry averaging. Overwhelming evidence exists to show that the inclusion of weak-intensity, high-resolution X-ray diffraction data helps improve the refinement of atomic models by imposing strong constraints on individual and overall temperature B factors and thus the quality of crystal structures. Some researchers consider these data to be of little value and opt to discard them during data processing, particularly at medium and low resolution, at which individual B factors of atomic models cannot be refined. Here, new evidence is provided to show that the inclusion of these data helps to improve the quality of experimental phases by imposing proper constraints on electron-density models during noncrystallographic symmetry (NCS) averaging. Using electron-density correlation coefficients as criteria, the resolution of data has successfully been extended from 3.1 to 2.5 Å resolution with redundancy-independent merging R factors from below 100% to about 310%. It is further demonstrated that phase information can be fully extracted from observed amplitudes through de novo NCS averaging. Averaging starts with uniform density inside double-shelled spherical masks and NCS matrices that are derived from bound heavy-atom clusters at the vertices of cuboctahedrally symmetric protein particles.
X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time-gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter-scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time- and location-tagged events at rates greater than 10(7) events per cm(2). Time-gating can be used for improved dynamic range.
We have compared the combined X-ray luminosity function (XLF) of low-mass X-ray binaries (LMXBs) detected in Chandra observations of young, post-merger elliptical galaxies with that of typical old elliptical galaxies. We find that the XLF of the 'young' sample does not present the prominent high-luminosity break at L{sub X} > 5 x 10{sup 38} erg s{sup -1} found in the old elliptical galaxy XLF. The 'young' and 'old' XLFs differ with a 3{sigma} statistical significance (with a probability less than 0.2% that they derive from the same underlying parent distribution). Young elliptical galaxies host a larger fraction of luminous LMXBs (L{sub X} > 5 x 10{sup 38} erg s{sup -1}) than old elliptical galaxies and the XLF of the young galaxy sample is intermediate between that of typical old elliptical galaxies and that of star-forming galaxies. This observational evidence may be related to the last major/minor mergers and the associated star formation.