Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Quality and Safety in Emergency Radiology

Purpose of Review: To review and outline problems and challenges in regard to patient safety along with solutions to overcome them. Recent Findings: Errors and discrepancies in radiology practice are disappointingly common. The estimated rate of errors is more than 5% in many targeted studies. This requires a detailed review of different types of errors in radiology and potential strategies to prevent them. Summary: An effective health care delivery system relies heavily on high degrees of skill in professionalism and communication. Strategies to prevent errors and improve communication with physicians in the Emergency Department are helpful in providing quality patient care, thus also decreasing the chances of conflicts and litigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

American College of Radiology In-Training Examination for Residents in Radiation Oncology (2004-2007)

Purpose: To review the results of the recent American College of Radiology (ACR) in-training examinations in radiation oncology and to provide information regarding the examination changes in recent years. Methods and Materials: A retrospective review of the 2004 to 2007 ACR in-training examination was undertaken. Results: The number of residents taking the in-training examination increased from 2004 to 2007, compatible with the increase in the number of radiation oncology residents in the United States and Canada. The number of questions decreased from approximately 510 in 2004 and 2005, to 405 in 2006 and 360 in 2007, most of these changes were in the clinical oncology section. Although the in-training examination showed construct validity with resident performance improving with each year of additional clinical oncology training, it did so only until Level 3 for biology and physics. Several changes have been made to the examination process, including allowing residents to keep the examination booklet for self-study, posting of the answer key and rationales to questions on the ACR Website, and providing hard copies to residency training directors. In addition, all questions are now A type or multiple choice questions with one best answer, similar to the American Board of Radiology written examination for radiation oncology. Conclusion: Several efforts by the ACR have been made in recent years to make the examination an educational tool for radiation oncology residents and residency directors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee Report on Electronic Brachytherapy

The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The American Board of Radiology Holman Research Pathway: 10-Year Retrospective Review of the Program and Participant Performance

Introduction: In 1999, the American Board of Radiology (ABR) implemented an innovative training program track in diagnostic radiology (DR) and radiation oncology (RO) designed to stimulate development of a cadre of future academic researchers and educators in the 2 disciplines. The program was designated the Holman Research Pathway (HRP). An in-depth retrospective review of initial certification examination performance, post-training career choices, and academic productivity has not been written. This report represents a 10-year retrospective review of post-training performance of a cohort of trainees who have had sufficient time to complete their training and initial certification process and to enter practice. Methods and Materials: All pertinent proceedings of the ABR and Accreditation Council for Graduate Medical Education (ACGME) Residency Review Committees for DR and RO between 1997 and May 2011 were reviewed. Thirty-four HRP candidates who fulfilled the established evaluation criteria were identified, and their ABR data files were analyzed regarding performance on the qualifying and certifying examinations. All candidates were contacted directly to obtain a current curriculum vitae. Results: Twenty candidates in RO and 14 candidates in DR were identifiable for review. All candidates attained initial certification. At the time of analysis, 23 of 33 (66.6%) candidates were employed in full-time academic practice (1 DR candidate remained in a fellowship and was not evaluated regarding employment status). Fifteen of 20 (75%) RO candidates were in faculty positions compared with 7 of 13 (53.8%) DR trainees. Additional academic productivity metrics are reported. Conclusions: A high percentage of HRP trainees remained in academic practice and demonstrated significant academic productivity as measured by manuscript authorship and research support. Additional time and observation will be needed to determine whether these findings will be sustained by past, current, and future HRP trainees.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron and photon spread contributions to the radiological penumbra for small monoenergetic x-ray beam (<=2 MeV)

Our team has previously published that submegavoltage photons could significantly improve the radiological penumbra for small size radiation fields. The present work uses Monte Carlo simulation to evaluate the contributions of secondary electrons and photon scatter to the penumbra region for various field sizes (5, 10, 20, and 40 mm in diameters) and for various monoenergetic photon beams (200, 400, 600, 800, 1000, and 2000 keV, and a standard 6 MV beam), minimizing geometrical and transmission penumbra. For field sizes less than 2 cm in diameter, photon scatter is negligible such that the secondary electrons are the main contributor to the radiological penumbra. Reducing the photon beam energy to the submegavoltage range reduces the range of secondary electrons and eventually improves the beam boundary sharpness. Provided that the geometrical penumbra and patient immobilization system are optimized, submegavoltage photon beams with effective photon energies in the 300 to 600 keV range, present significant advantages for multiple beam stereotactic irradiations of tumors less than 2 cm in diameter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Monitoring Results for Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2012-October 31, 2013

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond WRU-I-0160-01, Modification 1 (formerly LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2014 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types

Purpose: Multiple approaches to radiologically inserted gastrostomy (RIG) exist. The goal of this study was to compare 30-day outcomes and associated complications between large bore balloon-retained (BR), loop-retained (LR), and pull-type (PT) RIG devices. Methods: Data on 1477 patients who underwent RIG between January 1, 2005 and December 31, 2016 were collected retrospectively using a dedicated interventional radiology database and electronic medical record. Statistical analysis was performed to compare complication rates between BR, LR, and PT devices. Results: Ninety-eight percent (1477/1507) of the procedures were successfully performed. A total of 752 BR, 323 LR, and 402 PT gastrostomy tubes were placed. The overall complication rate for BR catheters was 5.7% (25 major [3.3%] and 18 minor [2.4%]). The overall complication rate for PT catheters was 3.7% (8 major [2.0%] and 7 minor [1.7%]). The overall complication rate for LR catheters was 1.6% (4 major [1.4%] and 1 minor [0.8%]). Compared to BR catheters, LR catheters had significantly fewer total complications (P = 0.01) but not minor complications (P = 0.052). There were no significant differences in the number of complications between LR and PT catheters or between BR and PT catheters. Conclusions: Use of BR, LR, and PT devices for RIG is safe with a low incidence of complications. Compared to BR catheters, primary insertion of a LR gastrostomy was associated with significantly fewer overall complications within the first 30 days. Therefore, for initial tube placement, large bore LR catheters may be preferred over BR devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological patterns of secondary sclerosing cholangitis in patients after lung transplantation

Purpose: The purpose of this study was to investigate the radiological patterns of secondary sclerosing cholangitis (SSC) following lung transplantation. Methods: Fifty-five patients underwent abdominopelvic CT before and after lung transplantation for end stage pulmonary disease. Nine patients underwent MR cholangiopancreatography (MRCP). The radiological patterns of biliary abnormalities (location, bile duct dilatation with stricture, beaded appearance, and biliary casts/sludge), laboratory data (serum total bilirubin and alkaline phosphatase), and patient survival rates were evaluated. SSC was diagnosed when there were newly developed biliary abnormalities with cholestasis after lung transplantation. Potential perioperative risk factors pertaining to SSC were analyzed. Patient survival rates with or without SSC were compared. Results: Six of the 55 patients showed imaging and laboratory findings of SSC after lung transplantation. Multifocal dilatation and stricture involved the intrahepatic (6 of 6, 100%), hilar (4 of 6, 66.7%), and extrahepatic bile duct (1 of 6, 16.7%). On CT, the lesions presented as multifocal small cyst-like lesions along the bile duct course. On MRCP, the lesions showed beaded appearance with mild duct dilatation. Preoperative mechanical ventilation and bilateral lung transplantation were associated with SSC (p < 0.05). The median survival of patients with SSC was 4.6 months. Conclusion: Lung transplantation can induce SSC similar to SSC in critically ill patients, and result in worse clinical outcomes than in patients without SSC. Multifocal small cyst-like lesions along the intrahepatic bile duct on CT and beaded appearance on MRCP are suggestive findings of SSC in patients with cholestasis after lung transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended abdominopelvic MRI versus CT at the time of adnexal mass characterization for assessing radiologic peritoneal cancer index (PCI) prior to cytoreductive surgery

Purpose: To evaluate whether extending the MRI scan to include the abdomen at the time of adnexal mass characterization could replace additional CT for peritoneal cancer index (PCI) assessment. Methods: After institutional review board approval for this prospective study, 36 consecutive females with ovarian and FT malignancies were included. All patients signed an informed consent. Patients underwent preoperative CT (32 patients) and MRI (36 patients). Images were interpreted by 2 independent observers. Surgical data were available in 27 patients. Region-by-region analysis was performed for detection rates of peritoneal carcinomatosis (PC). Inter-observer agreement for each region was evaluated by kappa statistics. Radiologic PCI was calculated by CT and MRI independently and inter-observer agreement for CT and MRI as well as agreement between radiologic and surgical PCI were evaluated by weighted-kappa statistics. Results: On region-by-region analysis, the highest detection rates of PC were noted at the central abdomen and pelvis. Detection rates were higher by MRI than CT, mainly in bowel serosal surface, pelvis, and right upper abdomen regions. Inter-observer agreement of MRI was higher than CT in most regions. The median PCI by CT was 5 and 4 for the first and second observers (range 0–21 for both observers), respectively. The median PCI by MRI was 6 (range 0–23 for both observers). The inter-observer agreement of PCI was excellent by both CT and MRI (k = 0.876 and k = 0.912, respectively). The agreement between CT and surgical PCI was 0.660 and 0.590 for the first and second observers, respectively. The agreement between MRI and surgical PCI was 0.797 and 0.798 for the first and second observers, respectively. Conclusions: Extending MRI scan to include the abdomen at the time of adnexal mass characterization allows accurate estimation of PC, with better results than CT, obviating the need for dedicated CT scan of abdomen and pelvis for imaging of PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Society of abdominal radiology gastrointestinal bleeding disease-focused panel consensus recommendations for CTA technical parameters in the evaluation of acute overt gastrointestinal bleeding

Purpose: To formulate consensus recommendations for CT angiography technical parameters used to evaluate overt gastrointestinal (GI) bleeding. Methods: An electronic questionnaire consisting of 17 questions was sent to a panel of 16 radiologists with expertise on the imaging of GI bleeding from the Society of Abdominal Radiology GI Bleeding disease-focused panel to obtain consensus agreement on issues related to CTA technical parameters for imaging overt GI bleeding. A multi-round Delphi method of voting was performed to obtain consensus which was defined as ≥ 80% agreement. Results: Consensus agreement was reached in 15/17 (89%) of the questions including the technique for the administration of IV contrast, the number of phases, scan timing, and image reconstruction. Conclusions: A panel of experts on the imaging of GI bleeding from the Society of Abdominal Radiology was able to reach consensus on the majority of technical parameters used for CTA of overt GI bleeding. These recommendations should improve the quality of patient care by adopting these minimal technical requirements for optimal exam performance and lead to less variation in the performance of these exams which will facilitate collecting and comparing published data from different centers. These recommendations will need revisions as additional scientific data become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Multislice CT Angiography on Planning of Radiological Catheter Placement for Hepatic Arterial Infusion Chemotherapy

The objective of this study was to assess prospectively the role of multislice CT angiography (MSCTA) on planning of radiological catheter placement for hepatic arterial infusion chemotherapy (HAIC). Forty-six patients with malignant liver tumors planned for HAIC were included. In each patient, both MSCTA and intra-arterial digital subtraction angiography (DSA) were performed, except one patient who did not undergo DSA. Comparison of MSCTA and DSA images was performed for the remaining 45 patients. Detectability of anatomical variants of the hepatic artery, course of the celiac trunk, visualization scores of arterial branches and interobserver agreement, presence of arterial stenosis, and technical outcome were evaluated. Anatomical variations of the hepatic artery were detected in 19 of 45 patients (42%) on both modalities. The course of the celiac trunk was different in 12 patients. The visualization scores of celiac arterial branches on MSCTA/DSA were 3.0 {+-} 0/2.9 {+-} 0.2 in the celiac trunk, 3.0 {+-} 0/2.9 {+-} 0.3 in the common hepatic artery, 2.9 {+-} 0.2/2.9 {+-} 0.3 in the proper hepatic artery, 2.9 {+-} 0.3/2.9 {+-} 0.4 in the right hepatic artery, 2.8 {+-} 0.4/2.9 {+-} 0.4 in the left hepatic artery, 2.9 {+-} 0.2/2.9 {+-} 0.3 in the gastroduodenal artery, 2.1 {+-} 0.8/2.2 {+-} 0.9 in the right gastric artery, and 2.7 {+-} 0.8/2.6 {+-} 0.8 in the left gastric artery. No statistically significant differences exist between the two modalities. Interobserver agreement for MSCTA was equivalent to that for DSA. Two patients showed stenosis of the celiac trunk on both modalities. Based on these imaging findings, technical success was accomplished in all patients. In conclusion, MSCTA is accurate in assessing arterial anatomy and abnormalities. MSCTA can provide adequate information for planning of radiological catheter placement for HAIC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Radiology in China

With more than 3000 members, the Chinese Society of Interventional Radiology (CSIR) is one of the world's largest societies for interventional radiology (IR). Nevertheless, compared to other societies such as CIRSE and SIR, the CSIR is a relatively young society. In this article, the status of IR in China is described, which includes IR history, structure and patient management, personnel, fellowship, training, modalities, procedures, research, turf battle, and insightful visions for IR from Chinese interventional radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Insertion of Denver Peritoneovenous Shunts for Malignant Refractory Ascites: A Retrospective Multicenter Study (JIVROSG-0809)

Purpose: Peritoneal venous shunts (PVSs) are widely used for palliating symptoms of refractory malignant ascites and are recognized as one of the practical methods. However, reliable clinical data are insufficient because most previous reports have been small studies from single centers. We conducted a retrospective, multicenter study to evaluate the safety and efficacy of radiologically placed PVSs in patients with malignant refractory ascites. Methods: A total of 133 patients with malignant ascites refractory to medical therapies were evaluated for patient characteristics, technical success, efficacy, survival times, adverse events, and changes in laboratory data. Results: PVSs were successfully placed in all patients and were effective (i.e., improvement of ascites symptoms lasting 7 days or more) in 110 (82.7%). The median duration of symptom palliation was 26 days and median survival time was 41 days. The most frequent adverse event was PVS dysfunction, which occurred in 60 (45.1%) patients, among whom function was recovered with an additional minimally invasive procedure in 9. Abnormalities in coagulation (subclinical disseminated intravascular coagulation) occurred in 37 (27.8%) patients, although only 7 (5.3%) developed clinical disseminated intravascular coagulation. Other major adverse events were gastrointestinal bleeding (9.8%), sepsis (3.8%), and acute heart failure (3.0%). PVS was least effective in patients with elevated serum creatinine, bloody ascites, or gynecologic tumor. Conclusions: Radiological PVS is a technically feasible and effective method for palliating the symptoms from refractory malignant ascites, but preoperative evaluation and monitoring the postprocedural complications are mandatory to preclude severe adverse events after PVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurred in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

Introduction: Self-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients’ case notes. Univariate survival analysis was performed. Results: Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39–89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1–624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current Status of Interventional Radiology in the Management of Gastro-Entero-Pancreatic Neuroendocrine Tumours (GEP-NETs)

Within the group of Gastro-Entero-Pancreatic Neuroendocrine tumours (GEP-NETs), several heterogeneous malignancies are included with a variety of clinical manifestations and imaging characteristics. Often these cases are inoperable and minimal invasive treatment offered by image-guided procedures appears to be the only option. Interventional radiology offers a valid solution in the management of primary and metastatic GEP-NETs. The purpose of this review article is to describe the current status of the role of Interventional Radiology in the management of GEP-NETs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Provision of Interventional Radiology Services in Europe: CIRSE Recommendations

Interventional Radiology (IR) is an essential part of modern medicine, delivering minimally invasive patient-focused care, which has been proven to be safe and effective in both elective and emergency settings. The aim of this document is to outline the core requirements and standards for the provision of Interventional Radiological services, including training, certification, manpower, and accreditation. The ultimate challenge will be the adoption of these recommendations by different countries and health economies around the world, in turn ensuring equal access to IR treatments for all patients, the appropriate distribution of resources for IR service provision as well as the continued development of safe and high-quality IR services in Europe and beyond.

62 RADIOLOGY AND NUCLEAR MEDICINE↗