Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOBIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Low doses and non-targeted effects in environmental radiation protection; where are we now and where should we go?

The field of low dose radiobiology has advanced considerably in the last 30 years from small indications in the 1980's that all was not simple, to a paradigm shift which occurred during the 1990's, which severely dented the dose-driven models and DNA centric theories which had dominated until then. However while the science has evolved, the application of that science in environmental health protection has not. A reason for this appears to be the uncertainties regarding the shape of the low dose response curve, which lead regulators to adopt a precautionary approach to radiation protection. Radiation protection models assume a linear relationship between dose (i.e. energy deposition) and effect (in this case probability of an adverse DNA interaction leading to a mutation). This model does not consider non-targeted effects (NTE) such as bystander effects or delayed effects, which occur in progeny cells or offspring not directly receiving energy deposition from the dose. There is huge controversy concerning the role of NTE with some saying they reflect “biology” and that repair and homeostatic mechanisms sort out the apparent damage while others consider them to be a class of damage which increases the size of the target. One thing which has recently become apparent is that NTE may be very critical for modelling long-term effects at the level of the population rather than the individual. The issue is that NTE resulting from an acute high dose such as occurred after the A-bomb or Chernobyl occur in parallel with chronic effects induced by the continuing residual effects due to radiation dose decay. This means that if ambient radiation doses are measured for example 25 years after the Chernobyl accident, they only represent a portion of the dose effect because the contribution of NTE is not included. - Highlights: • This paper presents a new concept in Environmental Radiobiology, which could explain why effects are detected in Chernobyl and Fukushima wildlife at ambient doses which are very low. • We suggest that non-targeted effects such as genomic instability, lethal mutations and bystander signalling, contribute a persistent legacy dimension to the total measured effect. • This “historic dose” component needs to be incorporated into dose effect models in order to predict true levels of risk.

54 ENVIRONMENTAL SCIENCES↗

Hypofractionation: What Does It Mean for Prostate Cancer Treatment?

Purpose: Using current radiobiologic models and biologic parameters, we performed an exploratory study of the clinical consequences of hypofractionation in prostate cancer radiotherapy. Methods and Materials: Four hypofractionated treatment regimens were compared with standard fractionation of 2 Gy x 39 for prostate carcinoma using a representative set of anatomical structures. The linear-quadratic model and generalized equivalent uniform dose formalism were used to calculate normalized equivalent uniform dose (gEUD{sub 2}), from which tumor control probability and normal tissue complication probability were calculated, as well as 'complication-free tumor control probability' (P+). The robustness of the results was tested for various tumor alpha/beta values and broad interval of biologic parameters such as surviving fraction after a dose of 2 Gy (SF2). Results: A 2.5% and 5.8% decrease in NTCP for rectum and bladder, respectively, was predicted for the 6.5 Gy/fraction regimen compared with the 2 Gy/fraction. Conversely, TCP for hypofractionated regimens decreased significantly with increasing SF2 and alpha/beta. For tumor cells with SF2 = 0.4-0.5, P+ was superior for nearly all hypofractionated regimens even for alpha/beta values up to 6.5 Gy. For less responsive tumor cells (SF2 = 0.6), hypofractionation regimens were inferior to standard fractionation at much lower alpha/beta. Conclusion: For a sample set of anatomical structures, existing radiobiologic data and models predict improved clinical results from hypofractionation over standard fractionation not only for prostate carcinoma with low alpha/beta but also for high alpha/beta (up to 6.5 Gy) when SF2 < 0.5. Predicted results for specific patients may vary with individual anatomy, and large-scale clinical conclusions can be drawn only after performing similar analysis on an appropriate population of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deriving Prostate Alpha-Beta Ratio Using Carefully Matched Groups, Long Follow-Up and the Phoenix Definition of Biochemical Failure

Purpose: Prior studies have derived low values of alpha-beta ratio (a/ss) for prostate cancer of approximately 1-2 Gy. These studies used poorly matched groups, differing definitions of biochemical failure, and insufficient follow-up. Methods and Materials: National Comprehensive Cancer Network low- or low-intermediate risk prostate cancer patients, treated with external beam radiotherapy or permanent prostate brachytherapy, were matched for prostate-specific antigen, Gleason score, T-stage, percentage of positive cores, androgen deprivation therapy, and era, yielding 118 patient pairs. The Phoenix definition of biochemical failure was used. The best-fitting value for a/ss was found for up to 90-month follow-up using maximum likelihood analysis, and the 95% confidence interval using the profile likelihood method. Linear quadratic formalism was applied with the radiobiological parameters of relative biological effectiveness = 1.0, potential doubling time = 45 days, and repair half-time = 1 hour. Bootstrap analysis was performed to estimate uncertainties in outcomes, and hence in a/ss. Sensitivity analysis was performed by varying the values of the radiobiological parameters to extreme values. Results: The value of a/ss best fitting the outcomes data was >30 Gy, with lower 95% confidence limit of 5.2 Gy. This was confirmed on bootstrap analysis. Varying parameters to extreme values still yielded best-fit a/ss of >30 Gy, although the lower 95% confidence interval limit was reduced to 0.6 Gy. Conclusions: Using carefully matched groups, long follow-up, the Phoenix definition of biochemical failure, and well-established statistical methods, the best estimate of a/ss for low and low-tier intermediate-risk prostate cancer is likely to be higher than that of normal tissues, although a low value cannot be excluded.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Complication Probability Estimation by the Lyman-Kutcher-Burman Method Does Not Accurately Predict Spinal Cord Tolerance to Stereotactic Radiosurgery

Purpose: To determine whether normal tissue complication probability (NTCP) analyses of the human spinal cord by use of the Lyman-Kutcher-Burman (LKB) model, supplemented by linear-quadratic modeling to account for the effect of fractionation, predict the risk of myelopathy from stereotactic radiosurgery (SRS). Methods and Materials: From November 2001 to July 2008, 24 spinal hemangioblastomas in 17 patients were treated with SRS. Of the tumors, 17 received 1 fraction with a median dose of 20 Gy (range, 18-30 Gy) and 7 received 20 to 25 Gy in 2 or 3 sessions, with cord maximum doses of 22.7 Gy (range, 17.8-30.9 Gy) and 22.0 Gy (range, 20.2-26.6 Gy), respectively. By use of conventional values for {alpha}/{beta}, volume parameter n, 50% complication probability dose TD{sub 50}, and inverse slope parameter m, a computationally simplified implementation of the LKB model was used to calculate the biologically equivalent uniform dose and NTCP for each treatment. Exploratory calculations were performed with alternate values of {alpha}/{beta} and n. Results: In this study 1 case (4%) of myelopathy occurred. The LKB model using radiobiological parameters from Emami and the logistic model with parameters from Schultheiss overestimated complication rates, predicting 13 complications (54%) and 18 complications (75%), respectively. An increase in the volume parameter (n), to assume greater parallel organization, improved the predictive value of the models. Maximum-likelihood LKB fitting of {alpha}/{beta} and n yielded better predictions (0.7 complications), with n = 0.023 and {alpha}/{beta} = 17.8 Gy. Conclusions: The spinal cord tolerance to the dosimetry of SRS is higher than predicted by the LKB model using any set of accepted parameters. Only a high {alpha}/{beta} value in the LKB model and only a large volume effect in the logistic model with Schultheiss data could explain the low number of complications observed. This finding emphasizes that radiobiological models traditionally used to estimate spinal cord NTCP may not apply to the dosimetry of SRS. Further research with additional NTCP models is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Chest Wall Pain From Lung Stereotactic Body Radiotherapy for Different Fractionation Schemes

Purpose: Recent studies with two fractionation schemes predicted that the volume of chest wall receiving >30 Gy (V30) correlated with chest wall pain after stereotactic body radiation therapy (SBRT) to the lung. This study developed a predictive model of chest wall pain incorporating radiobiologic effects, using clinical data from four distinct SBRT fractionation schemes. Methods and Materials: 102 SBRT patients were treated with four different fractionations: 60 Gy in three fractions, 50 Gy in five fractions, 48 Gy in four fractions, and 50 Gy in 10 fractions. To account for radiobiologic effects, a modified equivalent uniform dose (mEUD) model calculated the dose to the chest wall with volume weighting. For comparison, V30 and maximum point dose were also reported. Using univariable logistic regression, the association of radiation dose and clinical variables with chest wall pain was assessed by uncertainty coefficient (U) and C statistic (C) of receiver operator curve. The significant associations from the univariable model were verified with a multivariable model. Results: 106 lesions in 102 patients with a mean age of 72 were included, with a mean of 25.5 (range, 12-55) months of follow-up. Twenty patients reported chest wall pain at a mean time of 8.1 (95% confidence interval, 6.3-9.8) months after treatment. The mEUD models, V30, and maximum point dose were significant predictors of chest wall pain (p < 0.0005). mEUD improved prediction of chest wall pain compared with V30 (C = 0.79 vs. 0.77 and U = 0.16 vs. 0.11). The mEUD with moderate weighting (a = 5) better predicted chest wall pain than did mEUD without weighting (a = 1) (C = 0.79 vs. 0.77 and U = 0.16 vs. 0.14). Body mass index (BMI) was significantly associated with chest wall pain (p = 0.008). On multivariable analysis, mEUD and BMI remained significant predictors of chest wall pain (p = 0.0003 and 0.03, respectively). Conclusion: mEUD with moderate weighting better predicted chest wall pain than did V30, indicating that a small chest wall volume receiving a high radiation dose is responsible for chest wall pain. Independently of dose to the chest wall, BMI also correlated with chest wall pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deciphering Time-Dependent DNA Damage Complexity, Repair, and Oxygen Tension: A Mechanistic Model for FLASH-Dose-Rate Radiation Therapy

Irradiation with ultrahigh dose rates (FLASH) has reemerged as a promising radiation therapy approach to effectively lower potential damage burden on normal tissue without sacrificing tumor control. However, the large number of recent FLASH studies have been conducted under vastly different experimental conditions and circumstances (ie, investigated biological endpoint, radiation quality, and environmental oxygen level), with unverified biological mechanisms of action and unexplored interplay effect of the main dependencies. To facilitate radiobiological investigation of FLASH phenomena and assessment of clinical applicability, we present an extension of the mechanistic radiobiological model “UNified and VERSatile bio response Engine” (UNIVERSE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison Between 3DCRT and IMRT Using Different Multileaf Collimators in the Treatment of Brain Tumors

We investigated the differences between 3-dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT), and the impact of collimator leaf-width on IMRT plans for the treatment of nonspherical brain tumors. Eight patients treated by 3DCRT with Novalis were selected. We developed 3 IMRT plans with different multileaf collimators (Novalis m3, Varian MLC-120, and Varian MLC-80) with the same treatment margins, number of beams, and gantry positions as in the 3DCRT treatment plans. Treatment planning utilized the BrainLAB treatment planning system. For each patient, the dose constraints and optimization parameters remained identical for all plans. The heterogeneity index, the percentage target coverage, critical structures, and normal tissue volumes receiving 50% of the prescription dose were calculated to compare the dosimetric difference. Equivalent uniform dose (EUD) and tumor control probability (TCP) were also introduced to evaluate the radiobiological effect for different plans. We found that IMRT significantly improved the target dose homogeneity compared to the 3DCRT. However, IMRT showed the same radiobiological effect as 3DCRT. For the brain tumors adjacent to (or partially overlapping with) critical structures, IMRT dramatically spared the volume of the critical structures to be irradiated. In IMRT plans, the smaller collimator leaf width could reduce the volume of critical structures irradiated to the 50% level for those partially overlapping with the brain tumors. For relatively large and spherical brain tumors, the smaller collimator leaf widths give no significant benefit.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Pitch and Jaw Width to Decrease Delivery Time of Helical Tomotherapy Treatments for Head and Neck Cancer

Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.86, 0.43, 0.287, and 0.215) were used with a (maximum) modulation factor setting of 4. Twelve plans were generated for each patient using an identical optimization procedure (e.g., number of iterations, objective weights, and penalties, etc.), based on recommendations from TomoTherapy (Madison, WI). The plans were compared using isodose plots, dose volume histograms, dose homogeneity indexes, conformity indexes, radiobiological models, and treatment times. Smaller pitches and jaw widths showed better target dose homogeneity and sparing of normal tissue, as expected. However, the treatment time increased inversely proportional to the jaw width, resulting in delivery times of 24 {+-} 1.9 min for the 1-cm jaw width. Although treatment plans produced with the 2.5-cm jaw were dosimetrically superior to plans produced with the 5-cm jaw, subsequent calculations of tumor control probabilities and normal tissue complication probabilities suggest that these differences may not be radiobiologically meaningful. Because treatment plans produced with the 5-cm jaw can be delivered in approximately half the time of plans produced with the 2.5-cm jaw (5.1 {+-} 0.6 min vs. 9.5 {+-} 1.1 min), use of the 5-cm jaw in routine treatment planning may be a viable approach to decreasing treatment delivery times from helical tomotherapy units.

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical dose and toxicity index of organs at risk in radiotherapy: Analyzing the calculated effects of modified dose fractionation in non–small cell lung cancer

To increase the efficacy of radiotherapy for non–small cell lung cancer (NSCLC), many schemes of dose fractionation were assessed by a new “toxicity index” (I), which allows one to choose the fractionation schedules that produce less toxic treatments. Thirty-two patients affected by non resectable NSCLC were treated by standard 3-dimensional conformal radiotherapy (3DCRT) with a strategy of limited treated volume. Computed tomography datasets were employed to re plan by simultaneous integrated boost intensity-modulated radiotherapy (IMRT). The dose distributions from plans were used to test various schemes of dose fractionation, in 3DCRT as well as in IMRT, by transforming the dose-volume histogram (DVH) into a biological equivalent DVH (BDVH) and by varying the overall treatment time. The BDVHs were obtained through the toxicity index, which was defined for each of the organs at risk (OAR) by a linear quadratic model keeping an equivalent radiobiological effect on the target volume. The less toxic fractionation consisted in a severe/moderate hyper fractionation for the volume including the primary tumor and lymph nodes, followed by a hypofractionation for the reduced volume of the primary tumor. The 3DCRT and IMRT resulted, respectively, in 4.7% and 4.3% of dose sparing for the spinal cord, without significant changes for the combined-lungs toxicity (p < 0.001). Schedules with reduced overall treatment time (accelerated fractionations) led to a 12.5% dose sparing for the spinal cord (7.5% in IMRT), 8.3% dose sparing for V{sub 20} in the combined lungs (5.5% in IMRT), and also significant dose sparing for all the other OARs (p < 0.001). The toxicity index allows to choose fractionation schedules with reduced toxicity for all the OARs and equivalent radiobiological effect for the tumor in 3DCRT, as well as in IMRT, treatments of NSCLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

A treatment planning approach to spatially fractionated megavoltage grid therapy for bulky lung cancer

The purpose of this study was to explore the treatment planning methods of spatially fractionated megavoltage grid therapy for treating bulky lung tumors using multileaf collimator (MLC). A total of 5 patients with lung cancer who had gross tumor volumes ranging from 277 to 635 cm{sup 3} were retrospectively chosen for this study. The tumors were from 6.5 to 9.6 cm at shortest dimension. Several techniques using either electronic compensation or intensity-modulated radiation therapy (IMRT) were used to create a variety of grid therapy plans on the Eclipse treatment planning system. The dose prescription point was calculated to the volume, and a dose of 20 Gy with 6-MV/15-MV beams was used in each plan. The dose-volume histogram (DVH) curves were obtained to evaluate dosimetric characteristics. In addition, DVH curves from a commercially available cerrobend grid collimator were also used for comparison. The linear-quadratic radiobiological response model was used to assess therapeutic ratios (TRs) and equivalent uniform doses (EUD) for all generated plans. A total of 6 different grid therapy plans were created for each patient. Overall, 4 plans had different electronic compensation techniques: Ecomps-Tubes, Ecomps-Circles, Ecomps-Squares, and Ecomps-Weave; the other 2 plans used IMRT and IMRT-Weave techniques. The DVH curves and TRs demonstrated that these MLC-based grid therapy plans can achieve dosimetric properties very similar to those of the cerrobend grid collimator. However, the MLC-based plans have larger EUDs than those with the cerrobend grid collimator. In addition, the field shaping can be performed for targets of any shape in MLC-based plans. Thus, they can deliver a more conformal dose to the targets and spare normal structures better than the cerrobend grid collimator can. The plans generated by the MLC technique demonstrated the advantage over the standard cerrobend grid collimator on accommodating targets and sparing normal structures. Overall, 6 different plans showed 6 different dosimetric parameters. However, an optimal grid therapy plan selection from among these 6 types requires more information from clinical trials and radiobiological studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

The physics of irradiation of biological matter by ion beams

In radiobiology, predicting the evolution of irradiated biological matter is nowadays an active field of research to identify DNA lesions or to adapt the radiotherapeutic protocols in radiation oncology. In this context, the numerical methods, based on Monte Carlo track-structure simulations, represent the most suitable and powerful tools for understanding the radiobiological damages induced by ionizing particles. Here, we report the theoretical differential and total cross sections, computed within the quantum mechanical continuum distorted wave-eikonal initial state (CDW-EIS) method, for ion impact on water vapor and DNA nucleobases. These cross sections have been used to build up the input database for the homemade Monte Carlo track-structure TILDA-V. A comparison between the theoretical predictions and the available experimental data is presented. Micro-dosimetry results obtained with TILDA-V are also reported.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Effect of Rosiglitazone on Radiation Damage in Bone Marrow Hemopoiesis

To study radiobiological effects and drugs, which can modify radiation injury, has an importance if we would like to avoid harmful effects of radiation due to emergency situations or treat patients with malignant diseases by radiotherapy. During the long treatment schedules patients may be treated by not only anticancer but many other drugs because of accompanying diseases. These drugs may also modify radiobiological effects. Rosiglitazone pre-treatment proved to be myeloprotective and accelerated recovery of 5-fluorouracil-damaged bone marrow in our previous experiments. Our new studies are designed to evaluate whether rosiglitazone has similar beneficial effects in radiation-damaged hemopoiesis. Bone marrow damage was precipitated by total body irradiation (TBI) using single increasing doses (2-10 Gy) of {gamma}--irradiation in groups of mice. Lethality was well correlated with damage in hemopoiesis measured by cellularity of bone marrow (LD{sub 50} values were 4.8 and 5.3 gray respectively). Rosiglitazone, an insulin-sensitizing drug, had no significant effect on bone marrow cellularity. Insulin resistance associated with obesity or diabetes mellitus type 2 is intensively growing among cancer patients requiring some kind of radiotherapy. Therefore it is important to know whether drugs used for their therapy can modify radiation effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single shot cell irradiations with laser-driven protons

Ion beams are relevant for radiobiological studies in basic research and for application in tumor therapy. Here we present a method to generate nanosecond proton bunches with single shot doses of up to 7 Gray by a tabletop high-power laser. Although in their infancy, laser-ion accelerators allow studying fast radiobiological processes at small-scale laboratories as exemplarily demonstrated by measurements of the relative biological effectiveness of protons in human tumor cells.

43 PARTICLE ACCELERATORS↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Effects of ionising radiation exposure in offspring and next generations: dosimetric aspects and uncertainties

The impact of the exposure to ionizing radiation in the offspring and next generation has been investigated in the last decades and currently is the subject of study of the ICRP Task Group 121. Studying the effects of radiation exposure in pre-conceptional and post-conceptional phases can be a challenge since potential effects to the fetus vary depending on the stage of fetal development. Epidemiology and radiobiology studies are the two sources of information one can use to correlate the radiation dose to the human body and tissues and the resulting effects. For a proper evaluation of the outcomes of such studies, and a correct appraisal of the exposure/dose-effect relationship, (i) reliable dosimetry, (ii) accurate reporting, and (iii) reproducibility of results are required. Although variables related to dose, including for instance source of radiation, geometry of irradiation, dose rate etc., are usually known, especially in radiobiology studies, often important details of the irradiation are not reported. In conclusion, based on standards developed by the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Disease (NIAID) and the National Institute of Standards and Technology (NIST), a review of the scientific studies used by the UNSCEAR to estimate the risk of hereditary effects, and by the ICRP in its current recommendations, was conducted to evaluate the way dosimetry was reported. Dosimetry and the related uncertainties were not adequately described in the vast majority of those studies. This does not necessarily mean that they do not provide relevant information, however it prevents from a thorough verification and reproduction of their findings. In order to guarantee the reliability and robustness of the process of revision of the estimates of risk and detriment it is therefore considered mandatory to include a careful check of the new relevant literature with regard to the criteria on the completeness and reproducibility of the dosimetric information.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Interpretation of the dosimetric results of three uniformity regularization methods in terms of expected treatment outcome

In IMRT treatment plan optimization there are various methods that try to regularize the variation of dose nonuniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution, they do not provide any information regarding the expected treatment outcome. When a treatment plan optimization is performed using biological measures, the final goal should be some indication about the expected tumor control or normal tissue complications, which is the primary goal of treatment planning (the association of treatment configurations and dose prescription with the treatment outcome). In this study, this issue is analyzed distinguishing the dose-oriented treatment plan optimization from the response-oriented optimization. Three different dose distributions were obtained by using a dose-based optimization technique, an EUD-based optimization without applying any technique for regularizing the nonuniformity of the dose distribution, and an EUD-based optimization using a variational regularization technique, which controls dose nonuniformity. The clinical effectiveness of the three dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in two head and neck and prostate cancer cases. The radiobiological models used are the linear-quadratic-Poisson and the Relative Seriality models. Furthermore, the complication-free tumor control probability and the biologically effective uniform dose (D-bar) were used for treatment plan evaluation and comparison. The radiobiological comparison shows that the EUD-based optimization using L-curve regularization gives better results than the EUD-based optimization without regularization and dose-based optimization in both clinical cases. Concluding, it appears that the applied dose nonuniformity regularization technique is expected to improve the effectiveness of the optimized IMRT dose distributions. However, more patient cases are needed to validate the statistical significance of the results and conclusions presented in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlation of a hypoxia based tumor control model with observed local control rates in nasopharyngeal carcinoma treated with chemoradiotherapy

Purpose: To extend the application of current radiation therapy (RT) based tumor control probability (TCP) models of nasopharyngeal carcinoma (NPC) to include the effects of hypoxia and chemoradiotherapy (CRT). Methods: A TCP model is described based on the linear-quadratic model modified to account for repopulation, chemotherapy, heterogeneity of dose to the tumor, and hypoxia. Sensitivity analysis was performed to determine which parameters exert the greatest influence on the uncertainty of modeled TCP. On the basis of the sensitivity analysis, the values of specific radiobiological parameters were set to nominal values reported in the literature for NPC or head and neck tumors. The remaining radiobiological parameters were determined by fitting TCP to clinical local control data from published randomized studies using both RT and CRT. Validation of the model was performed by comparison of estimated TCP and average overall local control rate (LCR) for 45 patients treated at the institution with conventional linear-accelerator-based or helical tomotherapy based intensity-modulated RT and neoadjuvant chemotherapy. Results: Sensitivity analysis demonstrates that the model is most sensitive to the radiosensitivity term {alpha} and the dose per fraction. The estimated values of {alpha} and OER from data fitting were 0.396 Gy{sup -1} and 1.417. The model estimate of TCP (average 90.9%, range 26.9%-99.2%) showed good correlation with the LCR (86.7%). Conclusions: The model implemented in this work provides clinicians with a useful tool to predict the success rate of treatment, optimize treatment plans, and compare the effects of multimodality therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct intratumoral infusion of liposome encapsulated rhenium radionuclides for cancer therapy: Effects of nonuniform intratumoral dose distribution

Purpose: Focused radiation therapy by direct intratumoral infusion of lipid nanoparticle (liposome)-carried beta-emitting radionuclides has shown promising results in animal model studies; however, little is known about the impact the intratumoral liposomal radionuclide distribution may have on tumor control. The primary objective of this work was to investigate the effects the intratumoral absorbed dose distributions from this cancer therapy modality have on tumor control and treatment planning by combining dosimetric and radiobiological modeling with in vivo imaging data. Methods: {sup 99m}Tc-encapsulated liposomes were intratumorally infused with a single injection location to human head and neck squamous cell carcinoma xenografts in nude rats. High resolution in vivo planar imaging was performed at various time points for quantifying intratumoral retention following infusion. The intratumoral liposomal radioactivity distribution was obtained from 1 mm resolution pinhole collimator SPECT imaging coregistered with CT imaging of excised tumors at 20 h postinfusion. Coregistered images were used for intratumoral dosimetric and radiobiological modeling at a voxel level following extrapolation to the therapeutic analogs, {sup 186}Re/{sup 188}Re liposomes. Effective uniform dose (EUD) and tumor control probability (TCP) were used to assess therapy effectiveness and possible methods of improving upon tumor control with this radiation therapy modality. Results: Dosimetric analysis showed that average tumor absorbed doses of 8.6 Gy/MBq (318.2 Gy/mCi) and 5.7 Gy/MBq (209.1 Gy/mCi) could be delivered with this protocol of radiation delivery for {sup 186}Re/{sup 188}Re liposomes, respectively, and 37-92 MBq (1-2.5 mCi)/g tumor administered activity; however, large intratumoral absorbed dose heterogeneity, as seen in dose-volume histograms, resulted in insignificant values of EUD and TCP for achieving tumor control. It is indicated that the use of liposomes encapsulating radionuclides with higher energy beta emissions, dose escalation through increased specific activity, and increasing the number of direct tumor infusion sites improve tumor control. For larger tumors, the use of multiple infusion locations was modeled to be much more efficient, in terms of activity usage, at improving EUD and TCP to achieve a tumoricidal effect. Conclusions: Direct intratumoral infusion of beta-emitting radionuclide encapsulated liposomes shows promise for cancer therapy by achieving large focally delivered tumor doses. However, the results of this work also indicate that average tumor dose may underestimate tumoricidal effect due to substantial heterogeneity in intratumoral liposomal radionuclide distributions. The resulting intratumoral distribution of liposomes following infusion should be taken into account in treatment planning and evaluation in a clinical setting for an optimal cancer therapy.

60 APPLIED LIFE SCIENCES↗