Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Minority-carrier diffusion length, minority-carrier lifetime, and photoresponsivity of {beta}-FeSi{sub 2} layers grown by molecular-beam epitaxy

We have epitaxially grown undoped {beta}-FeSi{sub 2} films on Si(111) substrates via atomic-hydrogen-assisted molecular-beam epitaxy. {beta}-FeSi{sub 2} films grown without atomic hydrogen exhibited p-type conduction with a hole density of over 10{sup 19} cm{sup -3} at room temperature (RT). In contrast, those prepared with atomic hydrogen showed n-type conduction and had a residual electron density that was more than two orders of magnitude lower than the hole density of films grown without atomic hydrogen (of the order of 10{sup 16} cm{sup -3} at RT). The minority-carrier diffusion length was estimated to be approximately 16 {mu}m using an electron-beam-induced current technique; this value is twice as large as that for {beta}-FeSi{sub 2} prepared without atomic hydrogen. This result could be well explained in terms of the minority-carrier lifetimes measured by a microwave photoconductance decay technique. The 1/e decay time using a 904 nm laser pulse was approximately 17 {mu}s, which is much longer than that for {beta}-FeSi{sub 2} prepared without atomic hydrogen (3 {mu}s). The photoresponsivity reached 13 mA/W at 1.31 {mu}m, which is the highest value ever reported for {beta}-FeSi{sub 2} films.

36 MATERIALS SCIENCE↗

Optimizing a Linear Array of Radiating Elements

EOPS empirically optimizes linear array of radiating elements. Program directly addresses problem of minimizing maximum side-lobe level of fixed length, linear arrays of radiating elements under realistic "on-the-vehicle" conditions. Used for both electromagnetic and acoustic arrays.

Blank, S. J.↗

Method of controlling coherent synchroton radiation-driven degradation of beam quality during bunch length compression

A method of avoiding CSR induced beam quality defects in free electron laser operation by a) controlling the rate of compression and b) using a novel means of integrating the compression with the remainder of the transport system: both are accomplished by means of dispersion modulation. A large dispersion is created in the penultimate dipole magnet of the compression region leading to rapid compression; this large dispersion is demagnified and dispersion suppression performed in a final small dipole. As a result, the bunch is short for only a small angular extent of the transport, and the resulting CSR excitation is small.

47 OTHER INSTRUMENTATION↗

Vibration Studies for the CLARA Interferometer

The purpose of the CLARA experiment is to study the nature of undulator radiation emitted by single electrons circulating in the IOTA storage ring. The classical and quantum properties of the radiation are investigated by measuring its coherence length, intensity fluctuations and time correlations. The experiment took data in IOTA Run 4 (2022-2023). The key component of the apparatus is a Mach-Zehnder interferometer (MZI), in which the optical length of one of the arms can be precisely controlled. For some measurements, the fine regulation of the arm length must be smaller than the radiation wavelength. For this reason, the apparatus is particularly sensitive to mechanical vibrations. In this note, we model and measure the effect of vibrations on the performance of the MZI under various conditions. Several improvements of the setup were implemented to minimize systematic distortions of the observed interference patterns. In this report, we present a mathematical model of the effect of mechanical vibrations on observed detector and coincidence rates. We also describe the measurements that were made to estimate the magnitude and spectra of rate fluctuations and their sources in the CLARA MZI under various conditions. Finally, we estimate the magnitude of arm length fluctuations and we deduce the sensitivity to coincidence-rate variations in our apparatus.

43 PARTICLE ACCELERATORS↗

Spatial coherence of the Stokes component of stimulated Raman scattering excited in a long multimode fibre

The mode structure of the Stokes component of stimulated Raman scattering (SRS) in a multimode fibre excited by a pump field with statistics corresponding to a narrowband Gaussian noise model is theoretically analysed. The relation is obtained between the number of spatially coherent radiation modes of the Stokes wave and fibre parameters and SRS excitation conditions. It follows from this relation that the degree of spatial coherence of the Stokes radiation at the fibre output is determined by the number of spatial modes of pump radiation and the averaged gain of the Stokes radiation over the interaction length. It is established that there exists the threshold gain at which the number of spatially coherent radiation modes of the Stokes component increases infinitely and, therefore, its spatial coherence tends to zero. The estimates of the number of spatially coherent radiation modes of the Stokes component showed that already at the Raman scattering excitation threshold their number is so great that the degree of spatial coherence of the Stokes component radiation corresponds to the degree of coherence of a thermal source radiation. The measured dispersion of spatial intensity fluctuations of the Stokes component sepa-rated by using an interference filter (with the transmission bandwidth {approx}1 nm at 620 nm) proved to be approximately three times higher than the dispersion of radiation intensity fluctuations of a luminescent lamp. The large dispersion of spatial intensity fluctuations of the Stokes component is caused most likely by individual intensity spikes in a small-scale (unresolved by a detector with a spatial resolution of {approx}14 {mu}m) speckle pattern produced in the detection plane by monochromatic Stokes radiation. (coherence)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-coherence terahertz tomography based on spatially separated counterpropagating beams with allowance for probe radiation absorption in the medium

This paper analyses low-coherence tomography of absorbing media with the use of spatially separated counterpropagating object and reference beams. A probe radiation source based on a broadband terahertz (THz) generator that emits sufficiently intense THz waves in the spectral range 90 – 350 μm and a prism spectroscope that separates out eight narrow intervals from this range are proposed for implementing this method. This allows media of interest to be examined by low-coherence tomography with counterpropagating beams in each interval. It is shown that, according to the Rayleigh criterion, the method is capable of resolving inhomogeneities with a size near one quarter of the coherence length of the probe radiation. In addition, the proposed tomograph configuration allows one to determine the average surface asperity slope and the refractive index and absorption coefficient of inhomogeneities 180 to 700 mm in size, and obtain spectra of such inhomogeneities in order to determine their chemical composition. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emulation of radiation transport in 3D stochastic media using 1D planar Monte Carlo stochastic media radiation transport algorithms

A subset of stochastic media radiation transport problems involves those in which radiation is incident on a thin slab of stochastic material. Particle tracking in 3D for such problems is expensive, and 1D planar models lack accuracy because they only allow the material to change in one dimension. Therefore, we propose dimensional emulation, which through a slight modification allows existing 1D planar geometry stochastic media radiation transport models to reproduce results from the equivalent 3D models by allowing the material to change in all three dimensions, reproducing the fidelity of the 3D model for the low computational cost of the 1D planar model. In this work, we apply dimensional emulation to three Monte Carlo stochastic media radiation transport models: Chord Length Sampling (CLS), the Local Realization Preserving method (LRP), and a variant of Conditional Point Sampling (CoPS). For a common Markovian benchmark set, the 3D emulation variants of these algorithms are numerically verified to reproduce the results of the 3D variants within statistics while running 1.3 to 2 times faster in the implementation within Sandia National Laboratories open-source research code PlaybookMC. The 3D emulation variants are also shown to yield a 72%–92% reduction in error for the thin slab problems in comparison to the 1D benchmark. As a result, the 3D emulation variant of CLS and CoPS-1 are shown to reproduce 3D CLS results that were used to approximate results for a 3D spherical inclusion geometry benchmark set.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SELF-ORGANIZED BRAIDING AND THE STRUCTURE OF CORONAL LOOPS

The Parker model for heating of the solar corona involves reconnection of braided magnetic flux elements. Much of this braiding is thought to occur at as yet unresolved scales, for example, braiding of threads within an extreme-ultraviolet or X-ray loop. However, some braiding may be still visible at scales accessible to TRACE or Hinode. We suggest that attempts to estimate the amount of braiding at these scales must take into account the degree of coherence of the braid structure. In this paper, we examine the effect of reconnection on the structure of a braided magnetic field. We demonstrate that simple models of braided magnetic fields which balance the input of topological structure with reconnection evolve to a self-organized critical state. An initially random braid can become highly ordered, with coherence lengths obeying power-law distributions. The energy released during reconnection also obeys a power law. Our model gives more frequent (but smaller) energy releases nearer to the ends of a coronal loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Creating versatile atom traps by applying near-resonant laser light in magnetic traps

We utilize the combination of two standard trapping techniques, a magnetic trap and an optical trap in a Raman setup, to propose a versatile and tunable trap for cold atoms. The created potential provides several advantages over conventional trapping potentials. One can easily convert the type of the trap, for example, from a single-well to a double-well trap. Atoms in different internal states can be trapped in different trap types, thereby enabling the realization of experiments with multicomponent Bose-Einstein condensates. Moreover, one can achieve variations of the trapping potential on small length scales without the need of microstructures. We present the potential surfaces for different setups, demonstrate their tunability, give a semianalytical expression for the potential, and propose experiments which can be realized within such a trap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-206-06: Analytic Dose Function for CT Scans in Infinite Cylinders as a Function of Scan Length and Cylinder Radius

Purpose: The radiation dose absorbed at a particular radius ρ within the central plane of a long cylinder following a CT scan is a function of the length of the scan L and the cylinder radius R along with kVp and cylinder composition. An analytic function was created that that not only expresses these dependencies but is integrable in closed form over the area of the central plane. This feature facilitates explicit calculation of the planar average dose. The “approach to equilibrium” h(L) discussed in the TG111 report is seamlessly included in this function. Methods: For a cylindrically symmetric radiation field, Monte Carlo calculations were performed to compute the dose distribution to long polyethylene cylinders for scans of varying L for cylinders ranging in radius from 5 to 20 cm. The function was developed from the resultant Monte Carlo data. In addition, the function was successfully fit to data taken from measurements on the 30 cm diameter ICRU/TG200 phantom using a real-time dosimeter. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. There are competing effects as the beam penetrates the cylinder from the outside: attenuation, resulting in a decrease; scatter, abruptly increasing at the circumference. This competition may result in an absolute maximum between the center and outer edge leading to a “gull wing” shape for the radial dependence. For the smallest cylinders, scatter may dominate to the extent that there is an absolute maximum at the center. Conclusion: An integrable, analytic function has been developed that provides the radial dependency of dose for the central plane of a scan of length L for cylinders of varying diameter. Equivalently, we have developed h(L,R,ρ).

60 APPLIED LIFE SCIENCES↗

Device for controlling additive manufacturing machinery

A computing device for controlling the operation of an additive manufacturing machine comprises a memory element and a processing element. The memory element is configured to store a three-dimensional model of a part to be manufactured, wherein the three-dimensional model defines a plurality of cross sections of the part. The processing element is in communication with the memory element. The processing element is configured to receive the three-dimensional model, determine a plurality of paths, each path including a plurality of parallel lines, determine a radiation beam power for each line, such that the radiation beam power varies non-linearly according to a length of the line, and determine a radiation beam scan speed for each line, such that the radiation beam scan speed is a function of a temperature of a material used to manufacture the part, the length of the line, and the radiation beam power for the line.

97 MATHEMATICS AND COMPUTING↗

Device for controlling additive manufacturing machinery

A computing device for controlling the operation of an additive manufacturing machine comprises a memory element and a processing element. The memory element is configured to store a three-dimensional model of a part to be manufactured, wherein the three-dimensional model defines a plurality of cross sections of the part. The processing element is in communication with the memory element. The processing element is configured to receive the three-dimensional model, determine a plurality of paths, each path including a plurality of parallel lines, determine a radiation beam power for each line, such that the radiation beam power varies non-linearly according to a length of the line, and determine a radiation beam scan speed for each line, such that the radiation beam scan speed is a function of a temperature of a material used to manufacture the part, the length of the line, and the radiation beam power for the line.

Barr, Christian↗

Device for controlling additive manufacturing machinery

A computing device for controlling the operation of an additive manufacturing machine comprises a memory element and a processing element. The memory element is configured to store a three-dimensional model of a part to be manufactured, wherein the three-dimensional model defines a plurality of cross sections of the part. The processing element is in communication with the memory element. The processing element is configured to receive the three-dimensional model, determine a plurality of paths, each path including a plurality of parallel lines, determine a radiation beam power for each line, such that the radiation beam power varies non-linearly according to a length of the line, and determine a radiation beam scan speed for each line, such that the radiation beam scan speed is a function of a temperature of a material used to manufacture the part, the length of the line, and the radiation beam power for the line.

Barr, Christian↗

Phenomenology of elastic energy loss

The unexpectedly strong suppression of high p{sub T} heavy quarks in heavy-ion collisions has given rise to the idea that partons propagating through a medium in addition to energy loss by induced radiation also undergo substantial energy loss due to elastic collisions. However, the precise magnitude of this elastic energy-loss component is highly controversial. Although for a parton inside a medium it is surprisingly difficult to define the difference between elastic and radiative processes rigorously, the main phenomenological difference is in the dependence of energy loss on in-medium path length: in a constant medium radiative energy loss is expected to grow quadratically with path length, elastic energy loss linearly. In this article, we investigate a class of energy-loss models with such a linear path-length dependence and demonstrate that they are incompatible with measured data on hard hadronic back-to-back correlations where a substantial variation of path length is probed. This indicates that any elastic energy-loss component has to be small.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SURFACE BRIGHTNESS PROFILES OF DWARF GALAXIES. II. COLOR TRENDS AND MASS PROFILES

In this second paper of a series, we explore the B − V , U − B , and FUV−NUV radial color trends from a multi-wavelength sample of 141 dwarf disk galaxies. Like spirals, dwarf galaxies have three types of radial surface brightness profiles: (I) single exponential throughout the observed extent (the minority), (II) down-bending (the majority), and (III) up-bending. We find that the colors of (1) Type I dwarfs generally become redder with increasing radius, unlike spirals which have a blueing trend that flattens beyond ∼1.5 disk scale lengths, (2) Type II dwarfs come in six different “flavors,” one of which mimics the “U” shape of spirals, and (3) Type III dwarfs have a stretched “S” shape where the central colors are flattish, become steeply redder toward the surface brightness break, then remain roughly constant beyond, which is similar to spiral Type III color profiles, but without the central outward bluing. Faint (−9 > M{sub B} > −14) Type II dwarfs tend to have continuously red or “U” shaped colors and steeper color slopes than bright (−14 > M{sub B} > −19) Type II dwarfs, which additionally have colors that become bluer or remain constant with increasing radius. Sm dwarfs and BCDs tend to have at least some blue and red radial color trend, respectively. Additionally, we determine stellar surface mass density (Σ) profiles and use them to show that the break in Σ generally remains in Type II dwarfs (unlike Type II spirals) but generally disappears in Type III dwarfs (unlike Type III spirals). Moreover, the break in Σ is strong, intermediate, and weak in faint dwarfs, bright dwarfs, and spirals, respectively, indicating that Σ may straighten with increasing galaxy mass. Finally, the average stellar surface mass density at the surface brightness break is roughly 1−2 M {sub ⊙} pc{sup −2} for Type II dwarfs but higher at 5.9 M {sub ⊙} pc{sup −2} or 27 M {sub ⊙} pc{sup −2} for Type III BCDs and dIms, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Space Life Sciences at NASA: Spaceflight Health Policy and Standards

In January 2005, the President proposed a new initiative, the Vision for Space Exploration. To accomplish the goals within the vision for space exploration, physicians and researchers at Johnson Space Center are establishing spaceflight health standards. These standards include fitness for duty criteria (FFD), permissible exposure limits (PELs), and permissible outcome limits (POLs). POLs delineate an acceptable maximum decrement or change in a physiological or behavioral parameter, as the result of exposure to the space environment. For example cardiovascular fitness for duty standards might be a measurable clinical parameter minimum that allows successful performance of all required duties. An example of a permissible exposure limit for radiation might be the quantifiable limit of exposure over a given length of time (e.g. life time radiation exposure). An example of a permissible outcome limit might be the length of microgravity exposure that would minimize bone loss. The purpose of spaceflight health standards is to promote operational and vehicle design requirements, aid in medical decision making during space missions, and guide the development of countermeasures. Standards will be based on scientific and clinical evidence including research findings, lessons learned from previous space missions, studies conducted in space analog environments, current standards of medical practices, risk management data, and expert recommendations. To focus the research community on the needs for exploration missions, NASA has developed the Bioastronautics Roadmap. The Bioastronautics Roadmap, NASA's approach to identification of risks to human space flight, revised baseline was released in February 2005. This document was reviewed by the Institute of Medicine in November 2004 and the final report was received in October 2005. The roadmap defines the most important research and operational needs that will be used to set policy, standards (define acceptable risk), and implement an overall Risk Management and Analysis process. Currently NASA is drafting spaceflight health standards for neurosensory alterations, space radiation exposure, behavioral health, muscle atrophy, cardiovascular fitness, immunological compromise, bone demineralization, and nutrition.

Davis, Jeffrey R.↗