Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Monte Carlo prediction of radiative heat transfer in inhomogeneous, anisotropic, nongray media

A Monte Carlo solution technique has been formulated to predict the radiative heat transfer in three-dimensional, inhomogeneous participating media which exhibit spectrally dependent emission and absorption and anisotropic scattering. Details of the technique and selected numerical sensitivities are discussed. The technique was applied to a problem involving a medium composed of a gas mixture of carbon dioxide and nitrogen and suspended carbon particles. A homogeneous medium was modeled to examine the effect of total pressure and carbon-particle concentration on radiative heat transfer. Variation in total pressure, over the range studied, had minimal effect on the amount of heat radiated to the enclosure walls and on the radiative-flux distribution within the medium. Increases in the carbon particle concentration produced significantly higher heat fluxes at the boundaries and altered the radiative flux distribution. The technique was then applied to an inhomogeneous medium to examine effects of specific temperature and carbon particle concentration distributions on radiative heat transfer. For the inhomogeneous conditions examined, the largest radiative flux divergence occurs near the center of the medium and the regions near some enclosure walls act as energy sinks.

HEAT FLUXES↗

Accurate Accumulation of Dose for Improved Understanding of Radiation Effects in Normal Tissue

The actual distribution of radiation dose accumulated in normal tissues over the complete course of radiation therapy is, in general, poorly quantified. Differences in the patient anatomy between planning and treatment can occur gradually (e.g., tumor regression, resolution of edema) or relatively rapidly (e.g., bladder filling, breathing motion) and these undermine the accuracy of the planned dose distribution. Current efforts to maximize the therapeutic ratio require models that relate the true accumulated dose to clinical outcome. The needed accuracy can only be achieved through the development of robust methods that track the accumulation of dose within the various tissues in the body. Specific needs include the development of segmentation methods, tissue-mapping algorithms, uncertainty estimation, optimal schedules for image-based monitoring, and the development of informatics tools to support subsequent analysis. These developments will not only improve radiation outcomes modeling but will address the technical demands of the adaptive radiotherapy paradigm. The next 5 years need to see academia and industry bring these tools into the hands of the clinician and the clinical scientist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angular distribution of photoelectrons at 584 A using polarized radiation

Photoelectron angular distributions for Ar, Xe, N2, O2, CO, CO2, and NH3 have been obtained at 584 A by observing the photoelectrons at a fixed angle and simply rotating the plane of polarization of a highly polarized photon source. The radiation from a helium dc glow discharge source was polarized (84%) using a reflection type polarizer

Hancock, W. H.↗

Longitudinal changes in red blood cell distribution width decades after radiation exposure in atomic–bomb survivors

Red blood cell distribution width (RDW), which generally increases with age, is a risk marker for morbidity and mortality in various diseases. We investigated the association between elevated RDW and prior radiation exposure by examining longitudinal RDW changes in 4204 atomic-bomb survivors over 15 years. A positive association was found between RDW and radiation dose, wherein RDW increased by 0·18%/Gy. This radiation-associated effect increased as the participants aged. Elevated RDW was also associated with higher all-cause mortality. The biological mechanisms underlying these observed associations merit further investigation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Understanding how minority relativistic electron populations may dominate charge state balance and radiative cooling of a post-thermal quench tokamak plasma

Minority relativistic electron populations can occur in a range of complex plasmas. Of specific interest is when runaway electrons form among the presence of high-atomic-number ion species in a tokamak plasma discharge. It has been recently demonstrated that ion charge state distributions and radiation losses at low bulk electron temperatures can be dominated by relativistic electrons, even though their density is orders of magnitude lower. Furthermore, this was attributed to the relativistic enhancement of electron impact inelastic cross sections. In this work, we provide a closer inspection of the atomic physics underpinning this effect. We also demonstrate the consequences of runaway enhanced scattering on post-disruption tokamak fusion discharges with neon and argon impurities present. Effects on charge state distributions, radiation and spectral characteristics, and reduced-order modeling considerations are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Undulator radiation in a periodic magnetic field with a constant component

We present an analytical investigation of radiation emitted by an electron moving in a planar undulator with a constant magnetic field component added to the periodic one. In order to calculate the spectrum and angular distribution of radiation, we use the technique of generalized Bessel functions. In particular, this method is effectively applied for the study of the influence of the constant magnetic field on the undulator radiation emitted both along and off its axis. The analytical formulation of the effect of the weak constant field enables us to estimate its critical magnitude that may produce a significant distortion in the undulator radiation distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of radiative properties and temperature distributions in coal-fired boiler furnaces by a portable image processing system

This paper presented an experimental investigation on the estimation of radiative properties and temperature distributions in a 670 t/h coal-fired boiler furnace by a portable imaging processing system. The portable system has been calibrated by a blackbody furnace. Flame temperatures and emissivities were measured by the portable system and equivalent blackbody temperatures were deduced. Comparing the equivalent blackbody temperatures measured by the portable system and the infrared pyrometer, the relative difference is less than 4%. The reconstructed pseudo-instantaneous 2-D temperature distributions in two cross-sections can disclose the combustion status inside the furnace. The measured radiative properties of particles in the furnace proved there is significant scattering in coal-fired boiler furnaces and it can provide useful information for the calculation of radiative heat transfer and numerical simulation of combustion in coal-fired boiler furnaces. The preliminary experimental results show this technology will be helpful for the combustion diagnosis in coal-fired boiler furnaces. (author)

01 COAL, LIGNITE, AND PEAT↗

TU-F-BRF-08: Intensity Modulation Expanded to Spatio-Temporal Space; IMRT Combined with Optimal Fractionation Schedule

Purpose: Past efforts to improve the therapeutic ratio have focused on a spatial approach where highly conformal radiation dose is given to tumors while minimizing dose to normal tissues, e.g., IMRT, VMAT, and IGRT. However, the fractionation schedule, i.e., a temporal approach to radiotherapy, has been largely overlooked so far in maximizing the therapeutic ratio. We establish a rigorous mathematical spatio-temporal approach to systematically investigate the feasibility and potential benefits of simultaneously optimizing radiation dose distribution in space and time. Methods: Stochastic control formalism is constructed to maximize the average tumor BED by choosing an optimal radiation dose distribution for an optimal number of fractions subject to normal tissue BED constraints. Three separate simulations are run on two groups of phantom cases; 5 cases with prostate cancer and 5 cases with head-and-neck cancer. (1) Conventional IMRT with 70Gy/35fx for head-and-neck, and 81Gy/45fx for prostate, (2) IMRT is done independently from the fractionation schedule optimization (S-model), (3) integrated spatio-temporal approach (I-model) where radiation intensities are simultaneously optimized for the first time ever in space and time. Final tumor BEDs from the three trials are compared in prostate and head-and-neck cases. Results: Numerical simulations show that final tumor BED from I-model is 20–90% larger than conventional IMRT, and 20-50% larger than S-model for head-and-neck cancer with α/β=10 and Tdouble=2–50 days. Final tumor BED from I-model is also 90–140% larger than conventional IMRT, and 20–30% larger than S-model for prostate cancer with α/β=2 and Tdouble=5–80 days. Conclusion: Our spatio-temporal optimization of radiotherapy allows an expansion of search space for the optimal treatment plans to include the temporal distribution of radiation dose in addition to the spatial distribution. Such spatio-temporal approach shows great potential to improve the therapeutic ratio, particularly with fast growing, aggressive tumors with short doubling time and/or low α/β.

60 APPLIED LIFE SCIENCES↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-AB-201-05: Determining the Direction Distribution of the Primary Radiation for a Cyberknife-M6

Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distribution was then projected to a 9.5 × 5.9 × 3.9 m{sup 3} vault, generating an “intensity map” using a binning of 50 × 50 cm{sup 2}. The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.

60 APPLIED LIFE SCIENCES↗

A Review of Experimental Animal Radon Health Effects [Book Chapter]

Abundant epidemiological data from underground miners confirm that radon decay products (progeny) are carcinogenic, although the evidence is less conclusive on the quantitative risks of these exposures, especially for indoor air. The imprecision results principally from differences between exposures in mining and domestic environments and from uncertainties about the interaction between smoking and exposure to radon progeny. Experimental animal studies of radon-induced lung cancer are particularly valuable for understanding the carcinogenicity of human radon exposures in the home and in the workplace. Animals can be exposed to a variety of agents under carefully controlled conditions and then sacrificed for the study of developing lesions or held for their life span for tumor development. The doses to critical cells in the respiratory tract can be determined, and these in turn can be related to doses to critical cells in the respiratory tract of humans exposed to similar aerosols. The study of radon-induced mutations and changes in expression of oncogenes and tumor-suppressor genes as well as growth factors and growth factor receptors during tumor progression in animals also provides valuable evidence on the underlying mechanisms of radon carcinogenesis. This evidence, particularly that of the efficiency for oncogenic transformation at low dose rates, is crucial to the determination of the risk of lung cancer from exposure to indoor levels of radon. This review of animal health effects data emphasizes the carcinogenicity of radon exposures in rats; mechanistic data on radon-induced lung tumors in rats are currently sparse and are not reviewed here.

560162* -- Radionuclide Effects, Kinetics, & Toxic↗

Bath and Shower Effect in Spinal Cord: The Effect of Time Interval

Purpose: To evaluate the time dependency of the sensitizing effect of a large low-dose field on a small high-dose field in the rat cervical spinal cord. Methods and materials: Irradiation experiments with a relatively low dose to a large volume (bath, 2 cm, 4 Gy) were combined with high doses to a small volume (shower, 4.7 mm, 26-43 Gy) at intervals of 8 minutes and 3, 12, and 24 hours. Both a functional score defined as motor impairment and a histologic score characterized as white matter necrosis were used as end points. Results: Application of the 4-Gy bath dose resulted in a significant decrease in 50% isoeffective dose (ED{sub 50}) from 48.7 Gy (small field) to 40.8 Gy. If the interval was extended, the ED{sub 50} increased to 44.4 (3 hours) and 44.8 Gy (12 hours), whereas a 24-hour interval resulted in a significant increase to 51.9 Gy. If the histologic end point was considered, the ED{sub 50} for all dose-response curves decreased slightly with 0.2 to 2.6 Gy without significantly changing the kinetics. Conclusions: The bath effect as applied in the bath-and-shower experiment lasted for at least 12 hours and disappeared in the 24-hour interval. This time scale clearly deviates from the repair kinetics in spinal cord derived from low-dose-rate and fractionated irradiations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time- and Dose-Dependency of Radiographic Normal Tissue Changes of the Lung After Stereotactic Radiotherapy

Purpose: Normal tissue changes (NTC) of the normal lung parenchyma are commonly seen after stereotactic single-dose radiotherapy (radiosurgery) of lung tumors. The aim of this study was to investigate the extent and dynamics of NTCs after radiosurgery. Methods and Materials: Fifty lung tumors in 49 patients were treated with radiosurgery. Follow-up CTs were anatomically matched to the treatment planning CTs, incorporating the treatment plan and enabling spatial correlation of initial radiation dose distribution and subsequent NTCs of the lung. Lung parenchyma was divided into nine areas of different radiation dose exposures (range, 6-35 Gy). Areas were investigated and compared at different time points according to the development of NTCs. Results: Twenty-six patients developed NTCs during follow-up. The evaluation of the dependency of the extent of NTCs on the amount of radiation dose lead to a linear model for the fixed effects: Fraction of reacting volume =Intercept{sub T} +0.0208 * Dose ('Dose' should be given in Gy). Dose had a slope of 0.0208 (fraction of normal tissue reaction/Gy) (SE 0.000804, p < 0.0001), implying a significant correlation between dose level and the extent of NTC. Conclusion: For radiosurgery of lung tumors, a significant correlation of radiation dose and the extent of NTCs could be demonstrated. Using the introduced formula, a preview on the extent of NTCs to develop in normal lung parenchyma according to the dose level can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗