Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pupil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Laboratory demonstration of the prediction of wind-blown turbulence by adaptive optics at 8 kHz with use of LQG control

The low-latency adaptive optical mirror system (LLAMAS) is designed to push the limits on achievable latencies and frame rates. It has 21 subapertures across its pupil. Here, a reformulated version of the linear quadratic Gaussian (LQG) method predictive Fourier control is implemented in LLAMAS; for all modes, it takes just 30 µs to compute. In the testbed, a turbulator mixes hot and ambient air to produce wind-blown turbulence. Wind prediction clearly improves correction when compared to an integral controller. Closed-loop telemetry shows that wind-predictive LQG removes the characteristic “butterfly” and reduces temporal error power by up to a factor of three for mid-spatial frequency modes. Strehl changes seen in focal plane images are consistent with telemetry and the system error budget.

47 OTHER INSTRUMENTATION↗

Fabrication of wedged multilayer Laue lenses

We present a new method to fabricate wedged multilayer Laue lenses, in which the angle of diffracting layers smoothly varies in the lens to achieve optimum diffracting efficiency across the entire pupil of the lens. This was achieved by depositing a multilayer onto a flat substrate placed in the penumbra of a straight-edge mask. The distance between the mask and the substrate was calibrated and the multilayer Laue lens was cut in a position where the varying layer thickness and the varying layer tilt simultaneously satisfy the Fresnel zone plate condition and Bragg’s law for all layers in the stack. This method can be used to extend the achievable numerical aperture of multilayer Laue lenses to reach considerably smaller focal spot sizes than achievable with lenses composed of parallel layers.

42 ENGINEERING↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme ultraviolet lithography: A few more pieces of the puzzle

The work described in this dissertation has improved three essential components of extreme ultraviolet (EUV) lithography: exposure tools, photoresist, and metrology. Exposure tools. A field-averaging illumination stage is presented that enables nonuniform, high-coherence sources to be used in applications where highly uniform illumination is required. In an EUV implementation, it is shown that the illuminator achieves a 6.5% peak-to-valley intensity variation across the entire design field of view. In addition, a design for a stand-alone EUV printing tool capable of delivering 15 nm half-pitch sinusoidal fringes with available sources, gratings and nano-positioning stages is presented. It is shown that the proposed design delivers a near zero line-edge-rougness (LER) aerial image, something extremely attractive for the application of resist testing. Photoresist. Two new methods of quantifying the deprotection blur of EUV photoresists are described and experimentally demonstrated. The deprotection blur, LER, and sensitivity parameters of several EUV photoresists are quantified simultaneously as base weight percent, photoacid generator (PAG) weight percent, and post-exposure bake (PEB) temperature are varied. Two surprising results are found: (1) changing base weight percent does not significantly affect the deprotection blur of EUV photoresist, and (2) increasing PAG weight percent can simultaneously reduce LER and E-size in EUV photoresist. The latter result motivates the development of an EUV exposure statistics model that includes the effects of photon shot noise, the PAG spatial distribution, and the changing of the PAG distribution during the exposure. In addition, a shot noise + deprotection blur model is used to show that as deprotection blur becomes large relative to the size of the printed feature, LER reduction from improved counting statistics becomes dominated by an increase in LER due to reduced deprotection contrast. Metrology. Finally, this dissertation describes MOSAIC, a new wavefront metrology that enables complete wavefront recovery from print or aerial image based measurements. This new technique, based on measuring the local focal length of the optic at sampled positions in the pupil, recovers the curvature of the aberration and uses the curvature to recover the aberration itself. In a modeled EUV implementation, MOSAIC is shown to recover the SEMATECH Berkeley MET wavefront with a 4.2% RMS error: a 4% improvement over the reported errors of the original lateral shearing interferometry wavefront measurement.

36 MATERIALS SCIENCE↗

A METHOD TO CALIBRATE THE HIGH-RESOLUTION CATANIA ASTROPHYSICAL OBSERVATORY SPECTROPOLARIMETER

The Catania Astrophysical Observatory Spectropolarimeter (CAOS) is a white-pupil cross-dispersed échelle spectrograph with a spectral resolution of up to R = 55,000 in the 375–1100 nm range in a single exposure, with complete coverage up to 856 nm. CAOS is linked to the 36-inch telescope, at Mount Etna Observatory, with a couple of 100 μ m optical fibers and it achieves a signal-to-noise ratio better than 60 for a V = 10 mag star in one hour. CAOS is thermally stabilized in temperature within a 0.01 K rms, so that radial velocities are measured with a precision better than 100 m s{sup −1} from a single spectral line. Linear and circular spectropolarimetric observations are possible by means of a Savart plate working in series with a half-wave and a quarter-wave retarder plate in the 376–850 nm range. As is usual for high-resolution spectropolarimeters, CAOS is suitable to measure all Stokes parameters across spectral lines and it cannot measure the absolute degree of polarization. Observations of unpolarized standard stars show that instrumental polarization is generally zero at 550 nm and can increase up to 3% at the other wavelengths. Since polarized and unpolarized standard stars are useless, we suggest a method to calibrate a high-resolution spectropolarimeter on the basis of the polarimetric properties of spectral lines formed in the presence of a magnetic field. As applied to CAOS, observations of magnetic chemically peculiar stars of the main sequence show that the cross-talk from linear to circular polarization is smaller than 0.4% and that conversion from circular to linear is less than 2.7%. Strength and wavelength dependences of cross-talk can be entirely ascribed, via numerical simulations, to the incorrect retardance of achromatic wave plates.

79 ASTRONOMY AND ASTROPHYSICS↗

The HETDEX Instrumentation: Hobby–Eberly Telescope Wide-field Upgrade and VIRUS

The Hobby–Eberly Telescope (HET) Dark Energy Experiment (HETDEX) is undertaking a blind wide-field low-resolution spectroscopic survey of 540 deg 2 of sky to identify and derive redshifts for a million Ly α -emitting galaxies in the redshift range 1.9 < z < 3.5. The ultimate goal is to measure the expansion rate of the universe at this epoch, to sharply constrain cosmological parameters and thus the nature of dark energy. A major multiyear Wide-Field Upgrade (WFU) of the HET was completed in 2016 that substantially increased the field of view to 22' diameter and the pupil to 10 m, by replacing the optical corrector, tracker, and Prime Focus Instrument Package and by developing a new telescope control system. The new, wide-field HET now feeds the Visible Integral-field Replicable Unit Spectrograph (VIRUS), a new low-resolution integral-field spectrograph (LRS2), and the Habitable Zone Planet Finder, a precision near-infrared radial velocity spectrograph. VIRUS consists of 156 identical spectrographs fed by almost 35,000 fibers in 78 integral-field units arrayed at the focus of the upgraded HET. VIRUS operates in a bandpass of 3500–5500 Å with resolving power R ≃ 800. VIRUS is the first example of large-scale replication applied to instrumentation in optical astronomy to achieve spectroscopic surveys of very large areas of sky. This paper presents technical details of the HET WFU and VIRUS, as flowed down from the HETDEX science requirements, along with experience from commissioning this major telescope upgrade and the innovative instrumentation suite for HETDEX.

79 ASTRONOMY AND ASTROPHYSICS↗

The oculometer

Automatic acquisition and tracking of pupil-iris boundary and of corneal reflection of light source in oculometer using electro-optic method for eye direction measurement

DATA ACQUISITION↗

Oculometer for remote tracking of eye movement

Prototype oculometer which tracks lateral eye position and measures the direction of the eyes optical axis, pupil size, and blink occurrence performs measurements on the subject on a real-time basis from a remote location.

Mason, K. A.↗

Helium window for shock-tube monochromators

Technique for coupling vacuum ultraviolet monochromator to shock tube to avoid loss of high energy ultraviolet light during quantitative measurements is described. System consists of helium gas window pumping through small aperture in entrance pupil of monochromator. Diagram of equipment and principles of operation are presented.

Thomas, G. M.↗

Effect of set size, age, and mode of stimulus presentation on information-processing speed.

First, second, and third grade pupils served as subjects in an experiment designed to show the effect of age, mode of stimulus presentation, and information value on recognition time. Stimuli were presented in picture and printed word form and in groups of 2, 4, and 8. The results of the study indicate that first graders are slower than second and third graders who are nearly equal. There is a gross shift in reaction time as a function of mode of stimulus presentation with increase in age. The first graders take much longer to identify words than pictures, while the reverse is true of the older groups. With regard to set size, a slope appears in the pictures condition in the older groups, while for first graders, a large slope occurs in the words condition and only a much smaller one for pictures.

Norton, J. C.↗

Analysis of laser heterodyne communications

Computer program, which predicts effects of optical aberrations on transmitters and receivers, includes effects of Gaussian pupil functions and utilizes algorithm that permits specification of number and location of output points for computed spread function results.

Cohen, S.↗

Exploration of an oculometer-based model of pilot workload

Potential relationships between eye behavior and pilot workload are discussed. A Honeywell Mark IIA oculometer was used to obtain the eye data in a fixed base transport aircraft simulation facility. The data were analyzed to determine those parameters of eye behavior which were related to changes in level of task difficulty of the simulated manual approach and landing on instruments. A number of trends and relationships between eye variables and pilot ratings were found. A preliminary equation was written based on the results of a stepwise linear regression. High variability in time spent on various instruments was related to differences in scanning strategy among pilots. A more detailed analysis of individual runs by individual pilots was performed to investigate the source of this variability more closely. Results indicated a high degree of intra-pilot variability in instrument scanning. No consistent workload related trends were found. Pupil diameter which had demonstrated a strong relationship to task difficulty was extensively re-exmained.

Krebs, M. J.↗

Zernike test. I - Analytical aspects. II - Experimental aspects

The Zernike phenomenon is interpreted in general interferometric terms to gain insight into the optimum design of disks suitable for a particular experimental situation. The design of Zernike disks for measuring small low-order aberrations is considered and evaluated; optimum parameters for disks 2, 3, 4, and 5 microns in radius are determined for an f/12 large-space-telescope system with an obscuration ratio of 0.4 at 0.6 micron. It is shown that optimization in this case provides sensitivities of better than one hundredth of a wavelength for the measurement of low-order aberrations. The procedure for manufacturing a Zernike disk is then described in detail, and results are reported for tests of a laboratory Zernike figure sensor containing a disk manufactured according to this procedure. In the tests, a laboratory wavefront-error simulator was used to introduce small aberration ranges, measurements of the changes in reimaged pupil intensity introduced by the disk were made for several aberration settings, and the measured changes were compared with the values predicted by the interferometric theory of Zernike tests. The results are found to agree within an error of one two-hundredth of a wavelength.

Golden, L. J.↗

Determination of ocean wave heights from synthetic aperture radar imagery

A calculation is presented for the cross-correlation of the radar images obtained by processing the same signal data over different portions of the chirp spectrum bandwidth as a function of the center frequency spacings for these portions. This is shown to be proportional to the square of the product of the characteristic function for ocean wave heights and the pupil function describing the chirp spectrum bandwidth used in the processing. Measurements of this function for ocean wave imagery over the coast of Alaska, the North Atlantic, and Monterey Bay, California, and correlation with the significant wave heights reported from ground truth data indicate that the synthetic aperture radar instrument can be used for providing wave height information in addition to the ocean wave imagery.

Jain, A.↗

Anastigmatic three-mirror telescope

A three-mirror telescope arrangement that can be corrected for four aberrations (coma, spherical aberration, field curvature, and astigmatism) is described. Geometric spot size is less than 0.1 sec of arc, in an easily accessible flat field of 1.5 deg. The primary-secondary configuration is Cassegrain-like, with the real image formed closely behind the primary. This secondary image is re-imaged by a tertiary mirror at roughly unit magnification. A small, flat mirror at the exit pupil, located between primary and tertiary, folds the light rectangularly away from the telescope axis. The shape of the large image area is helpful in space applications where several instruments may share the focal plane.

Korsch, D.↗

NTS-2 retroreflector array

The NTS-II Laser Retroreflector consists of a honeycomb tray onto which are mounted 44 fused silica cube corners with a 50-millimeter hexagonal entrance pupil and single infrared cube. A thermal shield with a highly reflective outer surface and a black inner surface was incorporated to shroud the assembly protecting it from extreme high temperature exposure thus reducing cube corner thermal distortions to a minimum. A dummy retroreflector, utilizing simulated aluminum cube corners was fabricated and vibration tested to qualification levels to substantiate the integrity of the tray and cube mounting clips. This dummy was further used in the spacecraft spin balance test. The flight Laser Retroreflector was tested to the flight level vibration spectrum to verify that the unit will survive its expected vibration environment. During this test several GFE cube corners exhibited slight crazing at the clip support mounting holes. These cubes were reworked and retested and proved to be satisfactory.

Source record↗

Passive imaging through the turbulent atmosphere - Fundamental limits on the spatial frequency resolution of a rotational shearing interferometer

The signal-to-noise (S/N) ratio to be expected when a 180 deg rotationally shearing interferometer is used for image recovery at the diffraction limit of a large telescope is computed. The variance and covariance of the irradiance fluctuations at the detector array are shown to yield measures of the high-frequency spatial spectrum of the source. Four fundamental sources of noise are considered: temporal fluctuations of the source, space-time fluctuations of the atmosphere, shot noise in the detected photocurrents, and the effects of finite sampling. S/N is found to be directly proportional to the angular resolution of the telescope, the single-frame integration time, the square root of the number of frames, the cube of the operating wavelength, the quantum efficiency of the detector, and the average spectral irradiance from the source on the pupil. It is inversely proportional to the cube of the field angle subtended by the source (or part thereof) under study.

Burke, J. J.↗