Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pumped Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Pumped Thermal Electricity Storage with Supercritical CO2 Cycles and Solar Heat Input

Pumped Thermal Electricity Storage (PTES) is an energy storage device that uses grid electricity to drive a heat pump that generates hot and cold storage reservoirs. This thermal potential is later used to power a heat engine and return electricity to the grid. In this article, a PTES variant that uses supercritical carbon dioxide (sCO2) as the working fluid is introduced. sCO2-PTES cycles have higher work ratios and power densities than the systems based on ideal gases that have been investigated to date. Furthermore, sCO2- PTES cycles may achieve higher round-trip efficiencies for a given hot storage temperature (up to 78% at 560°C). The sensitivity of PTES cycles to loss factors such as isentropic efficiencies and temperature differences between the power cycle and storage fluid is investigated. A second concept whereby an sCO2- PTES cycle is integrated with concentrating solar power (CSP) is introduced. This concept ‘time-shifts’ the recompression of an sCO2 recompression cycle to a period of lower electricity prices and stores the heat. When solar heat is dispatched, the recompressor may be avoided as the required heat is obtained from storage, thereby leading to increased heat engine efficiencies. The net work output of this integrated system is 10-18% greater than the conventional recompression cycle. Combining PTES with a CSP power cycle is therefore shown to improve the dispatch of solar heat as well as providing electricity storage services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Hydropower Baseline Cost Modeling, Version 2

Recent resource assessments conducted by the United States Department of Energy have identified significant opportunities for expanding hydropower generation through the addition of power to non-powered dams and on undeveloped stream-reaches. Additional interest exists in the powering of existing water resource infrastructure such as conduits and canals, upgrading and expanding existing hydropower facilities, and the construction new pumped storage hydropower. Understanding the potential future role of these hydropower resources in the nation’s energy system requires an assessment of the environmental and techno-economic issues associated with expanding hydropower generation. To facilitate these assessments, this report seeks to fill the current gaps in publically available hydropower cost estimating tools that can support the national-scale evaluation of hydropower resources.

13 HYDRO ENERGY↗

Experimental and analytical evaluation of a hydro-pneumatic compressed-air Ground-Level Integrated Diverse Energy Storage (GLIDES) system

In recent times, there has been a significant increase in intermittent renewable electricity capacity additions to the generation mix. This, coupled with an aging electrical grid that is poorly equipped to handle the ensuing mismatch between generation and use, has created a strong need for flexible, advanced bulk energy storage technologies. In this paper, one such technology recently invented and demonstrated at Oak Ridge National Laboratory is introduced and characterized. Similar to compressed-air energy storage, the Ground-Level Integrated Diverse Energy Storage (GLIDES) technology is based on gas compression/expansion, however, liquid-piston compression and expansion are utilized. In common with pumped-storage hydroelectricity, hydraulic turbomachines (pump/turbine) are utilized for energy storage and recovery, however, pressure vessels are utilized to create artificial elevation (head) difference, allowing pressure head of several thousands of feet to be reached. Furthermore, this paper reports on the experimental performance of the first GLIDES proof-of-concept prototype, and presents formulation and results from a validated physics-based simulation model.

25 ENERGY STORAGE↗

Costs of mitigating the environmental impacts of hydropower projects in the United States

Developers are required to mitigate the environmental impacts of hydropower projects in the United States (U.S.) but there is very little accessible information on the associated costs. This work compiles and analyses a dataset of environmental impacts mitigation costs for 182 hydropower projects based on documents obtained from the U.S. Federal Energy Regulatory Commission (FERC). The analysis shows that environmental costs vary wildly across hydropower project classes and mitigation measures, even when normalized by plant capacity. Capital costs per kilowatt are generally higher for relicensed conventional hydropower plants, and lower for new and relicensed pumped storage hydropower plants, relative to other project classes. Smaller plants tend to spend a higher share of total project costs on mitigating environmental impacts than larger plants, and measures related to Aquatic Species, Project Operations, and Recreation have the highest capital cost per kilowatt. These findings mean that environmental costs could become a key decision variable for new hydropower developments in the U.S. due to the small scale of most of the remaining potential and the increasing stringency of environmental requirements. Therefore, technologies to reduce the environmental impacts and costs of hydropower would be important for future project developments.

54 ENVIRONMENTAL SCIENCES↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future

This report is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The main insights from this study can also help inform policy development and investment decisions.

08 HYDROGEN↗

Hydro-mechanically coupled finite-element analysis of the stability of a fractured-rock slope using the equivalent continuum approach: a case study of planned reservoir banks in Blaubeuren, Germany

Construction works associated with the building of reservoirs in mountain areas can damage the stability of adjacent valley slopes. Seepage processes caused by the filling and drawdown operations of reservoirs also affect the stability of the reservoir banks over time. The presented study investigates the stability of a fractured-rock slope subjected to seepage forces in the lower basin of a planned pumped-storage hydropower (PSH) plant in Blaubeuren, Germany. The investigation uses a hydro-mechanically coupled finite-element analyses. For this purpose, an equivalent continuum model is developed by using a representative elementary volume (REV) approach. To determine the minimum required REV size, a large number of discrete fracture networks are generated using Monte Carlo simulations. These analyses give a REV size of 28 × 28 m, which is sufficient to represent the equivalent hydraulic and mechanical properties of the investigated fractured-rock mass. The hydro-mechanically coupled analyses performed using this REV size show that the reservoir operations in the examined PSH plant have negligible effect on the adjacent valley slope.

58 GEOSCIENCES↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future: Additional Modeling Scenarios to Explore Hydrogen Flexibility [Slides]

This slide deck is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The purpose of this slide deck is to supplement the main study (published in May 2024) with additional modeling scenarios to explore hydrogen flexibility.

08 HYDROGEN↗

How Today's Hydropower Impacts Tomorrow's Grid: Counterfactual Scenarios Showing Grid Impacts if Hydropower Goes Away

Amidst ongoing discussions about hydropower removals, retirements, and reduced availability due to drought and other environmental considerations, it is important to understand the long-term effects of reduced hydropower resources on the U.S. electric grid. This analysis uses the Regional Energy Deployment System (ReEDS™) grid planning model to compare several representative scenarios of retiring hydropower and pumped storage hydropower (PSH) capacity over time and explore the overall implications on the U.S. grid from present day through 2050. Reduced hydropower capacity and generation is replaced by a mix of both fossil and non-fossil resources, including natural gas, wind, solar, and battery technologies. Additional natural gas usage leads to an increase in cumulative national electric sector carbon dioxide and criteria pollutant operating emissions of less than 1% in many scenarios but up to 4-5.3% in some cases. Total electric sector costs also increase by <1% in many scenarios but up to 3.6% in the most extreme scenarios where nearly all the hydropower and PSH fleet retires, equating to $\$$340 billion in undiscounted costs. National results indicate that absent additional interventions, retiring hydropower and PSH capacity could increase electric sector emissions and direct capital and operating costs. However, more focused analysis is required to evaluate specific asset-level, local, and regional implications, and a broader scope is necessary to weigh these electric sector impacts alongside economic, ecological, water management, and other cross-sectoral effects that could be either negative or positive.

14 SOLAR ENERGY↗

Frequency Support Enhancement of a Permanent Magnet-Based Adjustable-Speed Pumped Hydropower Plant

When a permanent magnet (PM) -based adjustable-speed pumped storage hydropower (AS-PSH) plant delivers frequency response via the full-scaled power converter, there is power imbalance at the PM generator during the initial stage of the frequency response. This is because the AS-PSH has the different time constants between the power converter and wicket gate in the governor valve. Thus, this imbalance causes a sudden reduction of the rotational speed of the machine during the frequency response. As a result, a voltage deficit arises at the generator terminal in proportion to the decrement in the rotational speed, and thereby it is promising that the current flow at the converter will reach its limit when attempting to inject the commanded active power at a reduced voltage level. Thus, this causes the degradation of the frequency response of the AS-PSH due to the self-demagnetization at a reduced rotational speed. This paper proposes a frequency support scheme of a PM-based AS-PSH to enhance the frequency response by bridging the gap between the different time constants. To achieve this, the frequency support scheme includes a gate opening adjustment in the governor and a dynamic ramp-down in converter controller of the AS-PSH.

13 HYDRO ENERGY↗

Grid Planning Impacts of Hydropower Growth and Decline

Hydropower and pumped storage hydropower (PSH) have a complex and uncertain future in the U.S. electricity system. On one hand, existing assets have the potential for an expanded role in integrating variable renewable energy while new deployment, particularly of PSH, can help meet growing needs for grid flexibility and improved reliability. On the other hand, challenging environmental and cost considerations could limit the extent of new investments in hydropower and PSH capacity and flexibility. This technical presentation demonstrates the use of a high-fidelity capacity expansion model of the U.S. electric grid (the National Renewable Energy Laboratory's Regional Energy Deployment System) to understand the impacts of alternative futures for the hydropower and PSH fleet, including scenarios of both growth and decline. Growth scenarios include new PSH deployment or improved hydropower flexibility, while scenarios of decline reduce the capacity or energy production potential of hydropower and PSH. Economic, environmental, and performance outcomes of the grid are compared across these scenarios to reveal the potential contributions of hydropower and PSH in the U.S. electric sector over the next several decades, focusing on changes to the grid technology mix, electric sector costs, electricity prices, and air emissions. This broad scenario approach demonstrates how flexible hydropower and PSH can help reduce air emissions and cost by complementing variable renewables, but the opposite can occur with reduced hydropower availability, particularly in the next decade. It is important to consider a wide range of scenarios and metrics to gain a national and regional understanding of hydropower's future in the United States.

capacity expansion↗

An Assessment of Energy Potential at Non-Powered Dams in the United States

The United States has produced clean, renewable electricity from hydropower for more than 100 years, but hydropower-producing facilities represent only a fraction of the infrastructure development that has taken place on the nation’s waterways. In contrast to the roughly 2,500 dams that provide 78 gigawatts (GW) 1 of conventional and 22 GW of pumped-storage hydropower, the United States has more than 80,000 non-powered dams (NPDs)—dams that do not produce electricity—providing a variety of services ranging from water supply to inland navigation. Importantly, many of the monetary costs and environmental impacts of dam construction have already been incurred at NPDs, so adding power to the existing dam structure can often be achieved at lower cost, with less risk, and in a shorter timeframe than development requiring new dam construction. The abundance, cost, and environmental favorability of NPDs, combined with the reliability and predictability of hydropower, make these dams a highly attractive source for expanding the nation’s renewable energy supply. To better characterize this unique national resource, the U.S. Department of Energy (DOE) Wind and Water Power Program has undertaken a national-scale analysis of U.S. dams to determine the ability of NPDs to provide hydroelectric power. DOE’s Oak Ridge National Laboratory (ORNL), with input from DOE’s Idaho National Laboratory, quantified the potential capacity and generation available from adding power production capability to U.S. NPDs. Of the more than 80,000 NPDs throughout the U.S., 54,391 dams were analyzed, with remaining dams eliminated from consideration due to erroneous geographic information, or erroneous flow or drainage area attributes that could not be resolved and corrected through independent investigation of maps and records. Anecdotal information suggests that these dams with missing or erroneous information are likely to be relatively small or have low potential to produce hydroelectric energy. Dams with a reported height of less than five feet were also excluded from analysis. A thorough quality control and review process ensured that the 54,391 remaining NPDs were analyzed and characterized as accurately as possible. Figure ES-1 demonstrates the spatial and capacity potential distribution of the nation’s NPDs. Electric generating capacities included in the report were calculated using the assumption that all water passing a facility would be available for conversion into electrical energy and that hydraulic head at the facility would remain constant. The analysis did not consider the economic feasibility of developing each unpowered facility. The assessment provides preliminary information for stakeholders (such as developers, municipal planners, and policymakers), who can further evaluate the potential to increase hydropower production at NPD sites. Developers could use the information provided in this assessment to focus on more detailed analysis of sites that demonstrate a reasonable potential for being developed. Adding power to U.S. NPDs has the potential to add up to 12 GW (12,000 megawatts or MW) of new renewable capacity—a potential equivalent to increasing the size of the existing conventional hydropower fleet by 15%. A majority of this potential is concentrated in just 100 NPDs, which could contribute approximately 8 GW of clean, reliable hydropower; the top 10 facilities alone could add up to 3 GW of new hydropower. Eighty-one of the 100 top NPDs are U.S. Army Corps of Engineers (USACE) facilities, many of which, including all of the top 10, are navigation locks on the Ohio River, Mississippi River, Alabama River, and Arkansas River, as well as their major tributaries. This study also shows that dams owned by the U.S. Bureau of Reclamation hold the potential to add approximately 260 MW of capacity; the Bureau has also engaged in an effort to conduct a more detailed evaluation of its own facilities.

13 HYDRO ENERGY↗

Quantifying the Value of Hydropower in the Electric Grid: Final Report

The report summarizes a 3-year DOE study focused on defining value of hydropower assets in a changing electric grid. The study looked at existing large hydropower operations in the U.S., models for different electricity futures, markets, costs of existing and new technologies as well as trends related to hydropower investments in other parts of the world.

13 HYDRO ENERGY↗

Compensation for Long-Duration Energy Storage

Rapidly changing power system conditions, driven by decarbonization goals, are leading to significant growth in renewable energy sources, which can be both variable and uncertain. This has been accompanied with increased reliance on and rapid growth in deployment of energy storage technologies. Currently, approximately 90% of installed, utility-scale energy storage capacity in the United States comes from pumped storage hydropower (PSH). However, development of new PSH has been limited and all recent growth in energy storage has come from batteries, , especially as technology costs have decreased over the years. Most of the current deployment still remains in the form of short-duration (<6 hours) energy storage technologies; the average duration of new storage was 3.7 hours for projects deployed in the first half of 2021 (Wood Mackenzie and Energy Storage Association 2021).

25 ENERGY STORAGE↗

Life Cycle Emissions Factors for Electricity Generation Technologies

This dataset consists of a table containing the distribution of literature estimates of greenhouse gas emissions for the following electricity generation and storage technologies: biopower, coal, concentrating solar power, geothermal, hydrogen storage, hydropower, lithium-ion battery storage, natural gas, nuclear, ocean, oil, photovoltaic, pumped-storage hydropower, and wind. Quartile estimates of life cycle emissions factors in units of grams of carbon dioxide equivalent per kilowatt hour of generation (g CO2e/kWh) are provided for the following life cycle stages: one-time upstream, ongoing combustion, ongoing non-combustion, one-time downstream, and total. Literature estimates were compiled by the LCA Harmonization study and subsequent updates, as detailed in the factsheet which accompanies this dataset, https://www.nlr.gov/docs/fy21osti/80580.pdf .

01 COAL, LIGNITE, AND PEAT↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Pumped Thermal Electricity Storage with Supercritical CO2 Cycles and Solar Heat Input: Preprint

Pumped Thermal Electricity Storage (PTES) is an energy storage device that uses grid electricity to drive a heat pump to generate hot and cold storage reservoirs. This thermal potential is later used to power a heat engine and return electricity to the grid. In this article, a PTES variant that uses supercritical carbon dioxide (sCO2) as the working fluid is introduced. sCO2-PTES cycles have higher work ratios and power densities than the systems based on ideal gases that have been investigated to date. Furthermore, sCO2-PTES cycles may achieve higher round-trip efficiencies for a given hot storage temperature (up to 78% at 560 degrees C). The sensitivity of PTES cycles to loss factors such as isentropic efficiencies and temperature differences between the power cycle and storage fluid is investigated. A second concept whereby an sCO2-PTES cycle is integrated with concentrating solar power (CSP) is introduced. This concept 'time-shifts' the recompression of an sCO2 recompression cycle to a period of lower electricity prices and stores the heat. When solar heat is dispatched, the recompressor may be avoided as the required heat is obtained from storage, thereby leading to increased heat engine efficiencies. The net work output of this integrated system is 10-18% greater than the conventional recompression cycle. Combining PTES with a CSP power cycle is therefore shown to improve the dispatch of solar heat as well as providing electricity storage services.

14 SOLAR ENERGY↗

Repowering Coal Plants as Pumped Thermal Energy Storage

This conference presentation presents the results from a DOE FE funded study on the integration of a Malta Pumped Heat Energy Storage system with a retiring coal-fired power plant, and the economic benefits to the asset owner and the local community.

20 FOSSIL-FUELED POWER PLANTS↗