AI-Based Protective Relays for Electric Grid Resiliency

The protection systems (circuit breakers, relays, reclosers, and fuses) of the electric grid are the primary component responding to resilience events, ranging from common storms to extreme events. The protective equipment must detect and operate very quickly, generally <0.25 seconds, to remove faults in the system before the system goes unstable or additional equipment is damaged. The burden on protection systems is increasing as the complexity of the grid increases; renewable energy resources, particularly inverter-based resources (IBR) and increasing electrification all contribute to a more complex grid landscape for protection devices. In addition, there are increasing threats from natural disasters, aging infrastructure, and manmade attacks that can cause faults and disturbances in the electric grid. The challenge for the application of AI into power system protection is that events are rare and unpredictable. In order to improve the resiliency of the electric grid, AI has to be able to learn from very little data. During an extreme disaster, it may not be important that the perfect, most optimal action is taken, but AI must be guaranteed to always respond by moving the grid toward a more stable state during unseen events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GIF Supercritical Water Cooled Reactor: Proliferation Resistance and Physical Protection White Paper

This report is part of a series of six white papers, prepared jointly by the Proliferation Resistance and Physical Protection Working Group (PRPPWG) and the six System Steering Committees (SSCs) and provisional System Steering Committees (pSSCs). This publication is an update to a similar series published in 2011 presenting the status of Proliferation Resistance & Physical Protection (PR&PP) characteristics for each of the six systems selected by the Generation IV International Forum (GIF) for further research and development, namely: the Sodium-cooled fast Reactor (SFR), the Very high temperature reactor (VHTR), the gas-cooled fast reactor (GFR), the Molten salt reactor (MSR) and the Supercritical water–cooled reactor (SCWR). This white paper represents the status of Proliferation Resistance and Physical Protection (PR&PP) characteristics for the Supercritical Water-cooled Fast reactor (SCFR) reference designs selected by the Generation IV International Forum (GIF) SCWR System Steering Committee (SSC). The intent is to generate preliminary information about the PR&PP features of the SCWR reactor technology and to provide insights for optimizing their PR&PP performance for the benefit of SCWR system designers. It updates the SCWR analysis published in the 2011 report “Proliferation Resistance and Physical Protection of the Six Generation IV Nuclear Energy Systems”, prepared Jointly by the Proliferation Resistance and Physical Protection Working Group (PRPPWG) and the System Steering Committees and provisional System Steering Committees of the Generation IV International Forum, taking into account the evolution of both the systems, the GIF R&D activities, and an increased understanding of the PR&PP features. The white paper, prepared jointly by the GIF PRPPWG and the GIF SCWR SSC, follows the highlevel paradigm of the GIF PR&PP Evaluation Methodology to investigate the PR&PP features of the eight proposed GIF SCWR designs. Two small modular reactors, the Canadian SSR and the Canada/China/Europe ECC-SMART are also mentioned. An overview of the fuel cycles for the GIF designs are provided. For PR, the document analyses and discusses the proliferation resistance aspects in terms of robustness against State-based threats associated with diversion of materials, misuse of facilities, breakout scenarios, and production in clandestine facilities. Similarly, for PP, the document discusses the robustness against theft of material and sabotage by non-State actors. The document follows a common template adopted by all the white papers in the updated series.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scoping Analysis of MACCS Modeling Improvements for the Study of Protective Action Recommendations

In late 2004, the U.S. Nuclear Regulatory Commission (NRC) initiated a project to analyze the relative efficacy of alternative protective action strategies in reducing consequences to the public from a spectrum of nuclear power plant core melt accidents. The study is documented in NUREG/CR-6953, “Review of NUREG-0654, Supplement 3, ‘Criteria for Protective Action Recommendations for Severe Accidents,’” Volumes 1, 2, and 3. The Protective Action Recommendations (PAR) study provided a technical basis for enhancing the protective action guidance contained in Supplement 3, “Guidance for Protective Action Strategies,” to NUREG-0654/FEMA-REP-1, Rev. 1, “Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, ” dated November 2011. In the time since, a number of important changes and additions have been made to the MACCS code suite, the nuclear accident consequence analysis code used to perform the study. The purpose of this analysis is to determine whether the MACCS results used in the PAR study would be different given recent changes to the MACCS code suite and input parameter guidance. Updated parameters that were analyzed include cohorts, keyhole evacuation, shielding and exposure parameters, compass sector resolution, and a range of source terms from rapidly progressing accidents. Results indicate that using updated modeling assumptions and capabilities may lead to a decrease in predicted health consequences for those within the emergency planning zone compared to the original PAR study.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fall Protection Introduction: Participant Guide

Worker safety is paramount at Los Alamos National Laboratory (LANL). According to the U.S. Bureau of Labor and Statistics, an estimated 671 workers are killed and approximately 58,000 injured on the job each year due to fall-related events. Therefore, ensuring that workers are provided with proper training and protection is critical. This module presents examples of activities that require fall protection, fall protection regulations and requirements, key definitions associated with fall protection, and training requirements for employees engaged in activities that require fall protection.

99 GENERAL AND MISCELLANEOUS↗

Instability of steady-state mixed-state symmetry-protected topological order to strong-to-weak spontaneous symmetry breaking

Recent experimental progress in controlling open quantum systems enables the pursuit of mixed-state nonequilibrium quantum phases. We investigate whether open quantum systems hosting mixed-state symmetry-protected topological states as steady states retain this property under symmetric perturbations. Focusing on the decohered cluster state – a mixed-state symmetry-protected topological state protected by a combined strong and weak symmetry – we construct a parent Lindbladian that hosts it as a steady state. This Lindbladian can be mapped onto exactly solvable reaction-diffusion dynamics, even in the presence of certain perturbations, allowing us to solve the parent Lindbladian in detail and reveal previously-unknown steady states. Using both analytical and numerical methods, we find that typical symmetric perturbations cause strong-to-weak spontaneous symmetry breaking at arbitrarily small perturbations, destabilize the steady-state mixed-state symmetry-protected topological order. However, when perturbations introduce only weak symmetry defects, the steady-state mixed-state symmetry-protected topological order remains stable. Additionally, we construct a quantum channel which replicates the essential physics of the Lindbladian and can be efficiently simulated using only Clifford gates, Pauli measurements, and feedback.

Shah, Jeet [University of Maryland, College Park, ↗

Comprehensive Evaluation for Protective Coatings: Optical, Electrical, Photoelectrochemical, and Spectroscopic Characterizations

Numerous efficient semiconductors suffer from instability in aqueous electrolytes. Strategies utilizing protective coatings have thus been developed to protect these photoabsorbers against corrosion while synergistically improving charge separation and reaction kinetics. Recently, various photoelectrochemical (PEC) protective coatings have been reported with suitable electronic properties to ensure low charge transport loss and reveal the fundamental photoabsorber efficiency. However, protocols for studying the critical figures of merit for protective coatings have yet to be established. For this reason, we propose four criteria for evaluating the performance of a protective coating for PEC water-splitting: stability, conductivity, optical transparency, and energetic matching. We then propose a flow chart that summarizes the recommended testing protocols for quantifying these four performance metrics. In particular, we lay out the stepwise testing protocols to evaluate the energetics matching at a semiconductor/coating/(catalyst)/liquid interface. Finally, we provide an outlook for the future benchmarking needs for coatings.

36 MATERIALS SCIENCE↗

Recombinant Vaccine Strain ASFV-G-Δ9GL/ΔUK Produced in the IPKM Cell Line Is Genetically Stable and Efficacious in Inducing Protection in Pigs Challenged with the Virulent African Swine Fever Virus Field Isolate Georgia 2010

We have previously reported that the recombinant African Swine Fever (ASF) vaccine candidate ASFV-G-Δ9GL/ΔUK efficiently induces protection in domestic pigs challenged with the virulent strain Georgia 2010 (ASFV-G). As reported, ASFV-G-Δ9GL/ΔUK induces protection, while intramuscularly (IM), administered at doses of 10 4 HAD 50 or higher, prevents ASF clinical disease in animals infected with the homologous ASFV g strain. Like other recombinant vaccine candidates obtained from ASFV field isolates, ASFV-G-Δ9GL/ΔUK stocks need to be produced in primary cultures of swine macrophages, which constitutes an important limitation in the production of large virus stocks at the industrial level. Here, we describe the development of ASFV-G-Δ9GL/ΔUK stocks using IPKM (Immortalized Porcine Kidney Macrophage) cells, which are derived from swine macrophages. We show that ten successive passages of ASFV-G-Δ9GL/ΔUK in IPKM cells induced small changes in the virus genome. The produced virus, ASFV-G-Δ9GL/ΔUKp10, presented a similar level of replication in swine macrophages cultures to that of the original ASFV-G-Δ9GL/ΔUK (ASFV-G-Δ9GL/ΔUKp0). The protective efficacy of ASFV-G-Δ9GL/ΔUKp10 was evaluated in pigs that were IM-inoculated with either 10 4 or 10 6 HAD 50 of ASFV-G-Δ9GL/ΔUKp10. While animals inoculated with 10 4 HAD 50 present a partial protection against the experimental infection with the virulent parental virus ASFV-G, those inoculated with 10 6 HAD 50 were completely protected. Therefore, as was just recently reported for another ASF vaccine candidate, ASFV-G-ΔI177L, IPKM cells are an effective alternative to produce stocks for vaccine strains which only grow in swine macrophages.

60 APPLIED LIFE SCIENCES↗

Computationally Selected Multivalent HIV-1 Subtype C Vaccine Protects Against Heterologous SHIV Challenge

Background: The RV144 trial in Thailand is the only HIV-1 vaccine efficacy trial to date to demonstrate any efficacy. Genetic signatures suggested that antibodies targeting the variable loop 2 (V2) of the HIV-1 envelope played an important protective role. The ALVAC prime and protein boost follow-up trial in southern Africa (HVTN702) failed to show any efficacy. One hypothesis for this is the greater diversity of subtype C viruses in southern Africa relative to CRF01_AE in Thailand. Methods: Here, we determined whether an ALVAC prime with computationally selected gp120 boost immunogens maximizing coverage of diversity of subtype C viruses in the variable V1 and V2 regions (V1V2) improved the protection of non-human primates (NHPs) from a heterologous subtype C SHIV challenge compared to more traditional regimens. Results: An ALVAC prime with Trivalent subtype C gp120 boosts resulted in statistically significant protection from repeated intrarectal SHIV challenges compared to the control. Evaluation of the immunogenicity of each vaccine regimen at the time of challenge demonstrated that different gp120 combination boosts elicited similar high magnitudes of gp120 and breadth of V1V2-binding antibodies, as well as strong Fc-mediated immune responses. Low-to-no neutralization of the challenge virus was detected. A Cox proportional hazard analysis of five pre-selected immune parameters at the time of challenge identified ADCC against the challenge envelope as a correlate of protection. Systems serology analysis revealed that immune responses elicited by the different vaccine regimens were distinct and identified further correlates of resistance to infection. Conclusions: Computationally designed vaccines with maximized subtype C V1V2 coverage mediated protection of NHPs from a heterologous Tier-2 subtype C SHIV challenge.

Immunology↗

Space vehicle integrated thermal protection/structural/meteoroid protection system, volume 1

A program was conducted to determine the merit of a combined structure/thermal meteoroid protection system for a cryogenic vehicle propulsion module. Structural concepts were evaluated to identify least weight designs. Thermal analyses determined optimum tank arrangements and insulation materials. Meteoroid penetration experiments provided data for design of protection systems. Preliminary designs were made and compared on the basis of payload capability. Thermal performance tests demonstrated heat transfer rates typical for the selected design. Meteoroid impact tests verified the protection characteristics. A mockup was made to demonstrate protection system installation. The best design found combined multilayer insulation with a truss structure vehicle body. The multilayer served as the thermal/meteoroid protection system.

Bartlett, D. H.↗

Approaches to rotor fragment protection

Key airworthiness design criteria considerations for fragment protection as found in various FAA requirements in FAR Parts 25 and 33, and in interpretive 8110 orders are reviewed. The impact of providing aircraft armor in lieu of engine armor for typical three- and four-engine wide bodied transports for protection within the length of the engine case as well as from fragments exiting ahead of the enlet engine inlet flange is assessed. For protection within the length of the engine case, armor weight penalties, plus fuel burned and dollar cost of carrying the armor protection are defined. Immediately ahead of the inlet flange, direct tangential impacts are predominant, but further forward, rebound impacts predominate. Armor thickness requirements and fuel cost impact of protection are given.

Oconnor, M. A., Jr.↗

Select state inland wetland protection laws. A review of the state laws and their natural resource data requirements

Although many states afford some measure of protection for wetland areas through flood-plain regulations or through programs for coastal areas, shorelands, scenic and wild rivers or pollution control, few states have programs that adequately deal with conservation of wetlands. Only 16 states have legislation specifically regulating development or use of wetlands. Most of the wetland acts apply only to coastal wetlands, several to inland wetlands and three acts apply to both. Many other states are still regulating wetland use through the dredge and fill and/or critical area program. Several offer tax incentives to property owners to encourage protection of wetlands or broader open spaces. Many states have acquired wetlands for park and wildlife purposes and a large measure of wetland protection is achieved by the very restrictive controls applied to floodways areas. Direct floodplain or floodway regulations or state standards for local regulations were adopted in 24 states but protection of ecological values of wetlands is rarely an explicit objective of these programs. Scenic and wild river programs adopted in one half of the states provide some protection for wetland areas.

Klein, S. B.↗

Performance criteria guideline for three explosion protection methods of electrical equipment rated up to 15,000 volts AC

The Bureau of Mines, U.S. Department of the Interior, is reviewing explosion protection methods for use in gassy coal mines. This performance criteria guideline is an evaluation of three explosion protection methods of machines electrically powered with voltages up to 15,000 volts ac. A sufficient amount of basic research has been accomplished to verify that the explosion proof and pressurized enclosure methods can provide adequate explosion protection with the present state of the art up to 15,000 volts ac. This routine application of the potted enclosure as a stand alone protection method requires further investigation or development in order to clarify performance criteria and verification certification requirements. An extensive literature search, a series of high voltage tests, and a design evaluation of the three explosion protection methods indicate that the explosion proof, pressurized, and potted enclosures can all be used to enclose up to 15,000 volts ac.

Linley, L. J.↗

Diamondlike carbon protective coatings for IR materials

Diamondlike carbon (DLC) films have the potential to protect optical windows in applications where it is important to maintain the integrity of the specular transmittance of these films on ZnS and ZnSe infrared transmitting windows. The films must be adherent and durable such that they protect the windows from rain and particle erosion as well as chemical attack. In order to optimize the performance of these films, 0.1 micro m thick diamondlike carbon films were deposited on fused silica and silicon wafers, using three different methods of ion beam deposition. One method was sputter deposition from a carbon target using an 8 cm ion source. The merits of hydrogen addition were experimentally evaluated in conjunction with this method. The second method used a 30 cm hollow cathode ion source with hydrocarbon/Argon gases to deposit diamondlike carbon films from the primary beam at 90 to 250 eV. The third method used a dual beam system employing a hydrocarbon/Argon 30 cm ion source and an 8 cm ion source. Films were evaluated for adherence, intrinsic stress, infrared transmittance between 2.5 and 50 micro m, and protection from particle erosion. An erosion test using a sandblaster was used to give quantitative values of the protection afforded to the fused silica by the diamondlike carbon films. The fused silica surfaces protected by diamondlike carbon films were exposed to 100 micro m diameter SiO particles at 60 mi/hr (26.8/sec) in the sandblaster.

Mirtich, M. J.↗

Oxidation and protection of fiberglass-epoxy composite masts for photovoltaic arrays in the low Earth orbital environment

Fiberglass-epoxy composites are considered for use as structural members for the mast of the space station solar array panel. The low Earth orbital environment in which space station is to operate is composed mainly of atomic oxygen, which has been shown to cause erosion of many organic materials and some metals. Ground based testing in a plasma asher was performed to determine the extent of degradation of fiberglass-epoxy composites when exposed to a simulated atomic oxygen environment. During exposure, the epoxy at the surface of the composite was oxidized, exposing individual glass fibers which could easily be removed. Several methods of protecting the composite were evaluated in an atomic oxygen environment and with thermal cycling and flexing. The protection techniques evaluated to date include an aluminum braid covering, an indium-tin eutectic and a silicone based paint. The open aluminum braid offered little protection while the CV-1144 coating offered some initial protection against atomic oxygen, but appears to develop cracks which accelerate degradation when flexed. Coatings such as the In-Sn eutectic may provide adequate protection by containing the glass fibers even though mass loss still occurs.

Rutledge, Sharon K.↗

Undercutting of defects in thin film protective coatings on polymer surfaces exposed to atomic oxygen

Protection for polymeric surfaces is needed to make them durable in the low Earth orbital environment, where oxidation by atomic oxygen is the predominant failure mechanism. Thin film coatings of oxides such as silicon dioxide are viable candidates to provide this protection, but concern has been voiced over the ability of these coatings to protect when defects are present in the coating due to surface anomalies occurring during the deposition process, handling, or micrometeoroid and debris bombardment in low Earth orbit. When a defected coating protecting a polymer substrate is exposed to atomic oxygen, the defect provides a pathway to the underlying polymer allowing oxidation and subsequent undercutting to occur. Defect undercutting was studied for sputter deposited coatings of silicon dioxide on polyimide Kapton. Preliminary results indicate that undercutting may be limited as long as the coating remains intact with the substrate. Therefore, coatings may not need to be defect free to give protection to the underlying surface.

Rutledge, Sharon K.↗

Photovoltaic array environmental protection program

During the photovoltaic array environmental protection program, a coating material, application technique, and design approach intended to protect flexible solar array blankets during a nominal fifteen-year operating lifetime were developed. Numerous thin-film coatings for protecting the Kapton polyimide material used in the construction of the Space Station Freedom flexible solar array blanket were evaluated. The critical solar array design features and protection measures are discussed with special emphasis on the effects of solar array fabrication and flexible printed circuit manufacturing processes on coating durability. The results of the mechanical and environmental test evaluation, including oxygen plasma, neutral oxygen beam, and UV/charged-particle combined exposure, are discussed. These results led to the selection of a silicon dioxide thin-film coating to protect the solar array blanket from the low-earth-orbit atomic oxygen environment.

Bilger, Kevin M.↗

Atomic oxygen interaction with solar array blankets at protective coating defect sites

Atomic oxygen in the low-Earth-orbital environment oxidizes SiOx protected polyimide Kapton solar array blankets at sites which are not protected such as pin windows or scratches in the protective coatings. The magnitude and shape of the atomic oxygen undercutting which occurs at these sites is dependent upon the exposure environment details such as arrival direction and reaction probability. The geometry of atomic oxygen undercutting at defect sites exposed to atomic oxygen in plasma asher was used to develop a Monte Carlo model to simulate atomic oxygen erosion processes at defect sites in protected Kapton. Comparisons of Monte Carlo predictions and experimental results are presented for plasma asher atomic oxygen exposures for large and small defects as well as for protective coatings on one or both sides of Kapton. The model is used to predict in-space exposure results at defect sites for both directed and sweeping atomic oxygen exposure. A comparison of surface textures predicted by the Monte Carlo model and those experimentally observed from both directed space ram and laboratory plasma asher atomic oxygen exposure indicate substantial agreement.

Banks, Bruce A.↗

Certification of lightning protection for a full-authority digital engine control

FADEC systems present many challenges to the lightning protection engineer. Verification of the protection-design adequacy for certification purposes presents additional challenges. The basic requirements of the certification plan of a FADEC is to demonstrate compliance with Federal Airworthiness Regulations (FAR) 25.1309 and 25.581. These FARs are intended for transport aircraft, but there are equivalent sections for general aviation aircraft, normal and transport rotorcraft. Military aircraft may have additional requirements. The criteria for demonstration of adequate lightning protection for a FADEC systems include the procedures outlined in FAA Advisory Circular (AC) 20-136, Protection of aircraft electrical/electronic systems against the indirect effects of lightning. As FADEC systems, including the interconnecting wiring, are generally not susceptible to direct attachment of lightning currents, the verification of protection against indirect effects is primarily described.