Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

Properties of Cosmic Deuterons Measured by the Alpha Magnetic Spectrometer

Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of the deuteron (𝐷) flux are presented. The measurements are based on 21 × 10 6 𝐷 nuclei in the rigidity range from 1.9 to 21 GV collected from May 2011 to April 2021. We observe that over the entire rigidity range the 𝐷 flux exhibits nearly identical time variations with the 𝑝, 3 He, and 4 He fluxes. Above 4.5 GV, the 𝐷/ 4 He flux ratio is time independent and its rigidity dependence is well described by a single power law ∝𝑅 Δ with Δ 𝐷/ 4 He = −0.108 ± 0.005. This is in contrast with the 3 He/ 4 He flux ratio for which we find Δ 3 He/ 4 He = −0.289 ± 0.003. Above ∼13 GV we find a nearly identical rigidity dependence of the 𝐷 and 𝑝 fluxes with a 𝐷/𝑝 flux ratio of 0.027 ± 0.001. These unexpected observations indicate that cosmic deuterons have a sizable primarylike component. With a method independent of cosmic ray propagation, we obtain the primary component of the 𝐷 flux equal to 9.4 ± 0.5% of the 4 He flux and the secondary component of the 𝐷 flux equal to 58 ± 5% of the 3 He flux.

cosmic ray acceleration↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A measurement of proton-carbon forward scattering in a proof-of-principle test of the EMPHATIC spectrometer

The next generation of long-baseline neutrino experiments will be capable of precision measurements of neutrino oscillation parameters, precision neutrino-nucleus scattering, and unprecedented sensitivity to physics beyond the Standard Model. Reduced uncertainties in neutrino fluxes are necessary to achieve high precision and sensitivity in these future precise neutrino measurements. New measurements of hadron-nucleus interaction cross sections are needed to reduce uncertainties of neutrino fluxes. We report measurements of the differential cross-section as a function of scattering angle for proton-carbon interactions with a single charged particle in the final state at beam momenta of 20, 30, and 120 GeV/c. These measurements are the result of a beam test for EMPHATIC, a hadron-scattering and hadron-production experiment. The total, elastic and inelastic cross-sections are also extracted from the data and compared to previous measurements. These results can be used in current and future long-baseline neutrino experiments, and demonstrate the feasibility of future measurements by an upgraded EMPHATIC spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antenna arrays for neutrino mass measurements with cyclotron radiation emission spectroscopy

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurements of kinetic energies of charged particles, pioneered by the Project 8 experiment to measure the neutrino mass using the tritium end-point method. It was recently employed for the first time to measure the molecular tritium spectrum and place a limit on the neutrino mass using a cubic-centimeter-scale detector. Future direct neutrino mass experiments are developing the technique to overcome the systematic and statistical limitations of current detectors. Here, this paper describes one such approach, namely the use of antenna arrays for CRES in free space. Phenomenology, detector design, simulation, and performance estimates are discussed, culminating with an example design with a projected sensitivity of 𝑚 𝛽 < ⁢0.04 eV/𝑐 2 . Prototype antenna array measurements are also shown for a demonstrator-scale setup as a benchmark for the simulation. By consolidating these results, this paper serves as a comprehensive reference for the development and performance of antenna arrays for CRES.

Physics - Nuclear physics and radiation physics↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

TDCOSMO XXIII. Measurement of the Hubble constant from the doubly lensed quasar HE 1104−1805

Time-delay cosmography leverages strongly lensed quasars to measure the Universe’s current expansion rate, H 0 , independently from other methods. The latest TDCOSMO milestone measurement primarily used quadruply lensed quasars for their mass profile constraints. However, doubly lensed quasars, being more abundant and offering precise time delays, could expand the sample by a factor of 5, significantly advancing towards a 1% precision measurement of H 0 . We present the first TDCOSMO analysis of a doubly imaged source, HE 1104−1805, including the measurement of the four necessary ingredients. First, by combining 17 years of data from the SMARTS, Euler, and WFI telescopes, we measured a time delay of 176.3 +11.4 −10.3 days. Second, using MUSE data, we extracted stellar velocity dispersion measurements in three radial bins with 5% to 13% precision. Third, employing F160W HST imaging for lens modelling and marginalising over various modelling choices, we measured the Fermat potential difference between the images. Fourth, using wide-field imaging, we measured the convergence added by objects not included in the lens modelling. By combining these four ingredients, we measured the time delay distance and the angular diameter distance to the deflector, favouring a power-law mass model over a baryonic and dark matter composite model. The measurement was performed blindly to prevent experimenter bias and resulted in a Hubble constant of H 0 = +5.8 −5.0 × λ int km s −1 Mpc −1 , where λ int is the internal mass sheet degeneracy parameter. This is in agreement with the TDCOSMO-2025 milestone and its precision for λ int = 1 is comparable to that obtained with the best-observed quadruply lensed quasars (4–6%). This work is a stepping stone towards a precise measurement of H 0 using a large sample of doubly lensed quasars, supplementing the current sample. The next TDCOSMO milestone paper will include this system in its hierarchical analysis, constraining λ int and H 0 jointly with multiple lenses.

cosmological parameters↗

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PickerXL, A Large Deep Learning Model to Measure Arrival Times from Noisy Seismic Signals

Precisely measuring seismic arrival times is a labor-intensive task but is critical for both earthquake monitoring and subsurface imaging. Recently published deep learning models have demonstrated superior performance compared to traditional automatic approaches for picking arrival times. Although existing deep learning models have shown promising results, further advancements are necessary as their performance is not yet satisfactory especially when applied to new regions and station networks. Increasing model size has led to improved performance in other machine learning applications. Here, we aimed to investigate whether enlarging deep learning models can increase performance on accepted benchmarks. We trained three models of varying sizes, small (1X), medium (4X), and large (16X), using globally distributed local and regional earthquake signals and background noise waveforms from a benchmark dataset, Stanford Earthquake Dataset. Our results indicate that the largest model (PickerXL) outperforms both the smaller models and Seisbench implementation of the PhaseNet model, which has the same number of parameters as our small model. The PickerXL model’s enhanced capacity to extract complex patterns from seismograms contributes to its superior arrival picking abilities compared to the smaller model.

Chai, Chengping [Oak Ridge National Laboratory (OR↗

Current and future neutrino oscillation constraints on leptonic unitarity

The unitarity of the lepton mixing matrix is a critical assumption underlying the standard neutrino-mixing paradigm. However, many models seeking to explain the as-yet-unknown origin of neutrino masses predict deviations from unitarity in the mixing of the active neutrino states. Motivated by the prospect that future experiments may provide a precise measurement of the lepton mixing matrix, we revisit current constraints on unitarity violation from oscillation measurements and project how next-generation experiments will improve our current knowledge. With the next-generation data, the normalizations of all rows and columns of the lepton mixing matrix will be constrained to ≲10% precision, with the e-row best measured at ≲1% and the τ-row worst measured at ~10% precision. The measurements of the mixing matrix elements themselves will be improved on average by a factor of 3. We highlight the complementarity of DUNE, T2HK, JUNO, and IceCube Upgrade for these improvements, as well as the importance of ντ appearance measurements and sterile neutrino searches for tests of leptonic unitarity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

The TAMUTRAP facility: A Penning trap facility at Texas A&M University for weak interaction studies

The Texas A&M University Penning Trap (TAMUTRAP) facility aims to test the standard model of the electroweak interaction by measuring the β-ν correlation parameter, a βν , for β-delayed proton emitters in the atomic mass range 20 < A < 40. Precision measurements of this correlation parameter and, inextricably, the Fierz interference parameter, are a sensitive probe of physics beyond the standard model. Here, using off-line ion sources, the TAMUTRAP facility has been commissioned by demonstrating the ability to manipulate the trapped-ion motions as well as to perform precision mass measurements. Our novel cylindrical Penning trap – the world's largest – differs from typical designs in two key aspects: the electrode structure has an 180-mm inner diameter and an overall length of 334.89 mm leading to a uniquely small length/radius ratio l/r = 3.72; and we do not use the long end cap approximation, instead our short endcap electrodes are closed and capable of being placed at an arbitrary potential. This geometry is optimized for observing β-delayed proton decays, but is also well suited for other in-trap and post-trap precision decay experiments. In addition to presenting an overview of the TAMUTRAP facility, we demonstrate that our unique Penning trap is able to measure masses with a precision similar to typical trap designs.

47 OTHER INSTRUMENTATION↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Ultrahigh-precision Compton polarimetry at 2 GeV

Here we report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A precision of dP/P = 0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest precision in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLD Compton polarimeter. Such precision reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID Experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Facile Approach to High Precision Detection of Cell-to-Cell Variation for Li-ion Batteries

Abstract Over the past decade, it has been repeatedly demonstrated that homogeneity in electrochemical performance of lithium-ion cells plays a major role in determining the life and safety of lithium-ion battery modules or packs. Generally, the homogeneity of a battery pack is evaluated by characterizing the cells individually in terms of capacity, mass, impedance. Particularly, high quality electrochemical data heavily relies on the availability of high precision current source to minimize the discrepancy induced by the channel-to-channel variation. Here, a facile and precise measurement method is reported for screening cell-to-cell variations, in which voltage is the only indicator parameter independent of high precision current source. In detail, by connecting the cells in series (CiS), the measurement error of electrochemical data caused by stability and discrepancy of current sources among different charge/discharge equipment can be effectively avoided. The findings of this work showed that the cell-to-cell variations can be simply and sensitively detected with CiS configuration. For example, the relative standard deviation, which is the evaluation criterion of battery homogeneity, was 2.14% based on CiS while it was 0.43% based on individual measurements. The simple and precise CiS measurement is promising for evaluation of cell quality or module integration quality. In addition, this work can also provide a solid foundation for the development of detection algorithms for battery management systems to rapidly monitor battery homogeneity.

25 ENERGY STORAGE↗