Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Exploring isospin symmetry breaking in exotic nuclei: High-precision mass measurement of 23 Si and shell-model calculations of 𝑇 = 5/2 nuclei

Here, we present a high-precision mass measurement of the proton-rich nucleus 23 Si, performed with the LEBIT Penning trap at the Facility for Rare Isotope Beams (FRIB) utilizing the time-of-flight ion cyclotron resonance (TOF-ICR) technique. We determined a mass excess of 23362.9(5.8) keV, which agrees with a recent storage-ring measurement from the experimental Cooler-Storage Ring (CSRe) in Lanzhou but has a factor of 20 improved precision 23 Si is hence the nucleus with the most precisely known mass among all nuclei with an isospin projection of 𝑇 𝑧 = −5/2. We performed shell-model calculations with the USDC and USDCm Hamiltonians to study binding energy differences and Thomas-Ehrmann shifts in mirror systems with an isospin up to 𝑇 = 5/2. Our experimental result and other recently reported masses of neutron-deficient sd-shell nuclei agree well with the theoretical predictions, demonstrating that isospin symmetry breaking in sd-shell nuclei—even at high isospin values—is well described by modern shell-model calculations.

20 ≤ A ≤ 38↗

A Measurement of the Eta Meson Radiative Decay Width via the Primakoff Effect

The ? meson is an interesting tool to study fundamental symmetries in Quantum Chromodynamics (QCD). In particular, its radiative decay width, ? p? Ñ ??q, is an important quantity that can be predicted in the framework of Chiral Perturbation Theory. A precision measurement of this quantity would provide critical inputs to understanding the mixing of the ? and ?1 mesons and extracting constants with wide-ranging applications in low-energy QCD. This decay width has been measured in the past using two different experimental techniques. The more popular technique utilized e`e´ collisions to produce ? mesons through electromagnetic interactions. Today, the Particle Data Group (PDG) averages the results of five such experiments to obtain their currently-accepted value of the decay width as: 0.515?0.018 keV. However the first measurement of this quantity was obtained from a fixed-target experiment that measured the cross section for photoproduction of ? mesons on a nuclear target via the Primakoff effect. Their result of 0.324?0.046 keV shows strong tension with the average of the collider measurements, motivating a new, high precision measurement using the Primakoff method. For this purpose, the PrimEx-eta experiment was conducted in Hall D of the Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab). The data is currently being analyzed to measure the differential cross section for the photoproduction of ? mesons on a liquid, 4He target. Preliminary results obtained from the analysis of the first phase of the PrimEx-eta experiment show reasonable agreement with the currently-accepted PDG value of the radiative decay width. However, as will be discussed, there are many challenges to this precision measurement which must be studied before any results can be finalized and compared with previous measurements. In parallel to the ? decay width measurement, the PrimEx-eta experiment measured the total cross section for the fundamental, Quantum Electrodynamics (QED) process of Compton scattering from the atomic electrons inside the target. The results obtained from this measurement are in strong agreement with the next-to-leading order QED calculations, and the total combined uncertainties are below 3% for incident photon energies between 7-10 GeV. In addition to providing the first precision measurement of the total Compton scattering cross section within this beam energy range, this measurement verifies the capability of the PrimEx-eta experimental setup to perform absolute cross section measurements at forward angles, and serves as a reference process for the calibration of systematic uncertainties.

Smith, Andrew↗

Double Chooz {theta}13 measurement via total neutron capture detection

Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.

Djurcic, Z.↗

Higgs boson width and couplings at high energy muon colliders with forward muon detection

We propose a novel method using the ZZ-fusion channel and forward muon detection at high energy muon colliders to address the challenge of the Higgs coupling-width degeneracy. Our approach enables inclusive Higgs rate measurement to 0.75% at 10 TeV muon collider, breaking the coupling-width degeneracy. Results indicate the potential to refine Higgs coupling to subpercent levels and estimate its total width within (–0.41%, +2.1%). Key insights include the effectiveness of forward muon tagging in signal-background separation despite broad recoil mass distribution due to muon energy reconstruction and beam energy spread. The study emphasizes the significance of muon rapidity coverage up to |η⁡(μ)| < 6, enhancing measurement precision. Our findings highlight the unique capabilities of high energy lepton colliders for model-independent Higgs coupling determination and lay the groundwork for future advancements in muon collider technology and Higgs physics research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Portable aerosol-particle counter

Device makes real-time, precise measurements of aerosols of small particle size. Measurement combines laser velocimetry and light scattering. Technique offers advantages over currently practiced techniques: by measuring aerosol size in real-time, measuring size precisely, and having high sensitivity in size range of greatest biological concern.

Weber, F. N., Jr.↗

Introduction to Radiation Issues for International Space Station Extravehicular Activities

The International Space Station (ISS) provides significant challenges for radiation protection of the crew due to a combination of circumstances including: the extended duration of missions for many crewmembers, the exceptionally dynamic nature of the radiation environment in ISS orbit, and the necessity for numerous planned extravehicular activities (EVA) for station construction and maintenance. Radiation protection requires accurate radiation dose measurements and precise risk modeling of the transmission of high fluxes of energetic electrons and protons through the relatively thin shielding provided by the space suits worn during EVA. Experiments and analyses have been performed due to the necessity to assure complete radiation safety for the EVA crew and thereby ensure mission success. The detailed characterization described of the material and topological properties of the ISS space suits can be used as a basis for design of space suits used in future exploration missions. In radiation protection practices, risk from exposure to ionizing radiation is determined analytically by the level of exposure, the detrimental quality of the radiation field, the inherent radiosensitivity of the tissues or organs irradiated, and the age and gender of the person at the time of exposure. During low Earth orbit (LEO) EVA, the relatively high fluxes of low-energy electrons and protons lead to large variations in exposure of the skin, lens of the eye, and tissues in other shallow anatomical locations. The technical papers in this publication describe a number of ground-based experiments that precisely measure the thickness of the NASA extravehicular mobility unit (EMU) and Russian Zvezda Orlan-M suits using medical computerized tomography (CT) X-ray analysis, and particle accelerator experiments that measure the minimum kinetic energy required by electrons and photons to penetrate major components of the suits. These studies provide information necessary for improving the understanding of the current ISS space suits and provide insights into improved approaches for the design of future suits. This chapter begins with a summary of the dynamic ionizing radiation environment in LEO space and introduces the concepts and quantities used to quantify exposure to space radiation in LEO. The space suits used for EVA and the experimental partial human phantom are described. Subsequent chapters report results from measured charged particle fields before and after incident protons and secondary particles are transported through the space suits and into organs and tissues.

Shavers, M. R.↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mapping the N = 40 island of inversion: Precision mass measurements of neutron-rich Fe isotopes

Nuclear properties across the chart of nuclides are key to improving and validating our understanding of the strong interaction in nuclear physics. Here we present high-precision mass measurements of neutron-rich Fe isotopes performed at the TITAN facility. The multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS), achieving a resolving power greater than 600000 for the first time, enabled the measurement of 63–70 Fe, including first-time high-precision direct measurements (δm/m ≈ 10 -7 ) of 68–70 Fe, as well as the discovery of a long-lived isomeric state in 69 Fe. These measurements are accompanied by both mean-field and ab initio calculations using the most recent realizations which enable theoretical assignment of the spin-parities of the 69 Fe ground and isomeric states. Together with mean-field calculations of quadrupole deformation parameters for the Fe isotope chain, these results benchmark a maximum of deformation in the N = 40 island of inversion in Fe and shed light on trends in level densities indicated in the newly refined mass surface.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermophysical property measurements in electromagnetic levitators

Proper measurements of thermophysical properties of hot levitated liquid drops require the following: accurate temperature measurement (brightness measurement, emissivity measurement); precise drop shape measurements with submillisecond time resolution (density determination, rotational and vibrational shape information); precise control of drop shape (high symmetry variable gap levitators); accurate energy transfer measurements (direct measurements of energy transfer rates for defined gas flows over samples with quantitative measurements of energy transfer rates for defined flows over samples with known shapes); and precise measurements of repetitive sample motions (rapid repetitive shape measurements, frequency measurements with reflected laser light, measurements in the levitator and as a freely falling drop). Recent advances in coil design and control of sample rotation in an electromagnetic levitator are discussed with respect to the above requirements.

Hauge, Robert H.↗

Precise mass measurement of the longest odd-odd chain of nuclei with 1+ ground states

Precise mass measurements of the ground and isomeric states of the odd-odd Rh108,110,112,114,116 were performed using the Canadian Penning Trap at Argonne National Laboratory, showing good agreement with recent JYFLTRAP measurements. A new possible isomeric state of Rh114 was also observed. These isotopes are part of the longest odd-odd chain of identical ground-state spin-parity assignment of 1+, spanning Rh104–118, despite being in a region of deformation. Realistic phenomenological mean-field calculations using the “universal” Wood-Saxon Hamiltonian were performed, which explained this phenomenon for the first time. In addition, multiquasiparticle blocking calculations were performed to study the configuration of low-lying states in the odd-odd Rh nuclei, elucidating anomalous isomeric yield ratio observed for Rh114.

Liu, B↗

Investigating nuclear structure near N=32 and N=34: Precision mass measurements of neutron-rich Ca, Ti, and V isotopes

Nuclear mass measurements of isotopes are key to improving our understanding of nuclear structure across the chart of nuclides, in particular, for the determination of the appearance or disappearance of nuclear shell closures. Here, we present high-precision mass measurements of neutron-rich Ca, Ti, and V isotopes performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) and the Low Energy Beam and Ion Trap (LEBIT) facilities. These measurements were made using the TITAN multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS) and the LEBIT 9.4T Penning trap mass spectrometer. In total, 13 masses were measured, 8 of which represent increases in precision over previous measurements. These measurements refine trends in the mass surface around N=32 and N=34, and support the disappearance of the N=32 shell closure with increasing proton number. Additionally, our data do not support the presence of a shell closure at N=34.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Vision for High Precision Volume Measurement Applied to Levitated Containerless Materials Processing

By combining the best practices in optical dilatometry with new numerical methods, a high-speed and high precision technique has been developed to measure volume of levitated, containerlessly processed samples with sub- pixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermo-physical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermo-ophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the sub-pixel locations of sample edges and, in turn produce high precision measurements.

Bradshaw, R. C.↗

Precise mass measurements of A = 133 isobars with the Canadian Penning Trap: Resolving the Q β − anomaly at 133Te

We report precision mass measurements of 133 Sb 133g,m Te, and 133g,m I, produced at CARIBU at Argonne National Laboratory's ATLAS facility and measured using the Canadian Penning Trap mass spectrometer. These masses clarify an anomaly in the 133 Te β-decay. The masses reported in the 2020 Atomic Mass Evaluation (M. Wang et al., 2021) produce Q B - ( 133 Te)=2920(6) keV; however, the highest-lying 133 I level populated in this decay is observed at E i = 2935.83(15) keV, resulting in an anomalous Q$^i_B-$ = -16(6)keV. Our new measurements give Q B - ( 133 Te)=2934.8(11) keV, a factor of five more precise, yielding Q$^i_B$ = -1.0(12) keV, a 3σ shift from the previous results. This resolves this anomaly, but indicates further anomalies in our understanding of the structure of this isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of Active Lava Flows on Kilauea Volcano, Hawaii, Using SIR-C Radar Correlation Measurements

Precise eruption rates of active pahoehoe lava flows on Kilauea volcano, Hawaii, have been determined using spaceborne radar data acquired by the Space Shuttle Imaging Radar-C (SIR-C). Measurement of the rate of lava flow advance, and the determination of the volume of new material erupted in a given period of time, are among the most important observations that can be made when studying a volcano.

volcano lava flow Kilauea spaceborne radar SIR-C↗

Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement

Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.

Chern, E. James↗