Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Powered By”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Simulating self-powered neutron detector responses to infer burnup-induced power distribution perturbations in next-generation light water reactors

Understanding how 3D power distribution will be monitored throughout reactor core volumetric space in next-generation nuclear power reactors is crucial to the design, deployment, and licensing of these reactors. Although numerous techniques exist for 3D power distribution monitoring based on the response of both in situ and ex situ sensors currently implemented or proposed for use in the US reactor fleet, crucial details about these techniques are often unclear. The publicly available documentation does not include information such as how well these techniques are characterized and optimized in their implementations and the levels of uncertainty in the inferred 3D power distribution. The work described herein investigated a recently developed 3D power distribution inferencing method as applied to two next-generation reactor simulations: (1) the NuScale small modular reactor design and (2) the Westinghouse AP1000 design, both of which contain in-core strings of vanadium self-powered neutron detectors (SPNDs). This investigation considered a range of SPND string sensor densities, as well as a range of 3D power distribution axial segment sizes. In this work, SPND response simulation is informed by neutron flux calculations in representative homogenized cores. For the different sensor densities and power distribution axial segment sizes in these simulations, the average solution error, solver iterations, and run time were tracked to parameterize the sensor-core configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The 2-loop matter power spectrum and the IR-safe integrand

Large scale structure surveys are likely the next leading probe of cosmological information. It is therefore crucial to reliably predict their observables. The Effective Field Theory of Large Scale Structures (EFTofLSS) provides a manifestly convergent perturbation theory for the weakly non-linear regime, where dark matter correlation functions are computed in an expansion of the wavenumber k over the wavenumber associated to the non-linear scale kNL. To push the predictions to higher wavenumbers, it is necessary to compute the 2-loop matter power spectrum. For equal-time correlators, exactly as with standard perturturbation theory, there are IR divergences present in each diagram that cancel completely in the final result. We develop a method by which all 2-loop diagrams are computed as one integral, with an integrand that is manifestly free of any IR divergences. This allows us to compute the 2-loop power spectra in a reliable way that is much less numerically challenging than standard techniques. We apply our method to scaling universes where the linear power spectrum is a single power law of k, and where IR divergences can particularly easily interfere with accurate evaluation of loop corrections if not handled carefully. In conclusion, we show that our results are independent of IR cutoff and, after renormalization, of the UV cutoff, and comment how the method presented here naturally generalizes to higher loops.

79 ASTRONOMY AND ASTROPHYSICS↗

Decentralized Voltage and Power Control of Multi-Machine Power Systems With Global Asymptotic Stability

Maintaining power system stability is becoming urgent due to the large-scale interconnection of power grids and the high penetration of uncertain renewable energy sources. The excitation control and governor control of synchronous generators have been considered as two crucial measures for enhancing the power system stability. However, a major challenge is to simultaneously achieve global asymptotic stability (GAS), voltage regulation (VR), and power regulation (PR) in the excitation and governor control. In this paper, a Lyapunov-based decentralized control (LBC) is proposed to address this challenge. The time-derivative of the Lyapunov function is designed by the feedback control of synchronous generators in order to guarantee GAS. VR and PR are ensured by considering voltage and power deviations as the feedback variables. The simulation results on the New-England ten-machine power system validate the effectiveness of the proposed LBC in improving power system transient stability and simultaneously achieving VR and PR. Although the proportional-integral- and power system stabilizer-based control can also perform VR and PR, the proposed control has much better dynamic performance and can more significantly improve the system transient stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exact Optimal Power Dispatch in Unbalanced Distribution Systems With High PV Penetration

Smart inverters provide additional control capability to help optimize the operation of distribution systems. This paper proposes a framework for exact optimal active and reactive power dispatch of distributed photovoltaic (PV) generation, switched capacitors, and tap changers in large multi-phase unbalanced distribution systems. The objectives of the optimal dispatch are minimization of the energy loss, PV active power curtailment, and capacitor and tap changer switching operations, in addition to elimination of voltage violations and reverse power flow. The optimization problem is formulated in rectangular coordinates as a nonlinear, nonconvex problem. Effective computational strategies are proposed to allow the application of predictorcorrector primal-dual interior point method to solve optimization problems in real-time with a large number of constraints and variables, including discrete variables corresponding to switched capacitors and tap changers. The accuracy of the numerical solution and the ability to implement the proposed framework are validated using the unbalanced multi-phase IEEE 34-bus and EPRI 2,998-bus distribution systems with 15-minute load and PV data. The results show a significant loss reduction and complete removal of both voltage violations and reverse power flow.

Nguyen, Quan (ORCID:0000000347769557)↗

The Power Reclamation of Utilizing Micro-Hydro Turbines in the Aeration Basins of Wastewater Treatment Plants

Upgrading the aeration basin technology can improve the oxygen transfer efficiency (OTE), while keeping the energy consumption at its minimum level. Therefore, this paper introduces a new idea of installing micro-propeller turbines in the aeration basin of a wastewater treatment plant (WWTP) to extract power from the high-velocity location in the water column. This extracted power can be used to operate a mixer at the top of the membrane to induce the mixing in that region, which will drive the less oxygenated wastewater into the water column. The rest of the extracted power will rotate microturbine rotors for electric power generation. By applying the proposed microturbines to the 13 audited facilities, it was demonstrated to achieve a gross annual energy-savings of 3,836.9 MWh, a gross annual cost-saving of $260,497, and total CO 2 emissions that would be reduced by 2,714 metric tons/year. Generally, the addition of the proposed microturbines can save up to 15.7% of the annual plant electricity consumption (1.3–12.8% of the plant annual electricity bills).

13 HYDRO ENERGY↗

Investigations into Balancing Peak-to-Average Power Ratio and Mean Power Extraction for a Two-Body Point-Absorber Wave Energy Converter

The power harnessed by wave energy converters (WECs) in oceans is highly variable and, therefore, has a high peak-to-average power (PTAP) ratio. To minimize the cost of a WEC power take off (PTO) system, it is desirable to reduce the PTAP ratio while maximizing the mean power extracted by WECs. The important issue of how PTAP ratio reduction measures (such as adding an inertia element) can affect the mean power extracted in a reference model has not been thoroughly addressed in the literature. To investigate this correlation, this study focuses on the integration of the U.S. Department of Energy’s Reference Model 3, a two-body point absorber, with a slider-crank WEC for linear-to-rotational conversion. In the first phase of this study, a full-scale numerical model was developed that predicts how PTO system parameters, along with an advanced control algorithm, can potentially affect the proposed WEC’s PTAP ratio as well as the mean power extracted. In the second phase, an appropriate scaled-down model was developed, and extracted power results were successfully validated against the full-scale model. Finally, numerical and hardware-in-the-loop (HIL) simulations based on the scaled-down model were designed and conducted to optimize or make trade-offs between the operational performance and PTAP ratio. The initial results with numerical and HIL simulations reveal that gear ratio, crank radius, and generator parameters substantially impact the PTAP ratio and mean power extracted.

16 TIDAL AND WAVE POWER↗

Compact, Low-Profile Power Converters: Highly-Laminated, High-Saturation-Flux-Density, Magnetic Cores for On-Chip Inductors in Power Converter Applications

ADEPT Project: Georgia Tech is creating compact, low-profile power adapters and power bricks using materials and tools adapted from other industries and from grid-scale power applications. Adapters and bricks convert electrical energy into useable power for many types of electronic devices, including laptop computers and mobile phones. These converters are often called wall warts because they are big, bulky, and sometimes cover up an adjacent wall socket that could be used to power another electronic device. The magnetic components traditionally used to make adapters and bricks have reached their limits; they can't be made any smaller without sacrificing performance. Georgia Tech is taking a cue from grid-scale power converters that use iron alloys as magnetic cores. These low-cost alloys can handle more power than other materials, but the iron must be stacked in insulated plates to maximize energy efficiency. In order to create compact, low-profile power adapters and bricks, these stacked iron plates must be extremely thin-only hundreds of nanometers in thickness, in fact. To make plates this thin, Georgia Tech is using manufacturing tools used in microelectromechanics and other small-scale industries.

ADEPT↗

Wind Power Forecasting Error Frequency Analyses for Operational Power System Studies: Preprint

The examination of wind power forecasting errors is crucial for optimal unit commitment and economic dispatch of power systems with significant wind power penetrations. This scheduling process includes both renewable and nonrenewable generators, and the incorporation of wind power forecasts will become increasingly important as wind fleets constitute a larger portion of generation portfolios. This research considers the Western Wind and Solar Integration Study database of wind power forecasts and numerical actualizations. This database comprises more than 30,000 locations spread over the western United States, with a total wind power capacity of 960 GW. Error analyses for individual sites and for specific balancing areas are performed using the database, quantifying the fit to theoretical distributions through goodness-of-fit metrics. Insights into wind-power forecasting error distributions are established for various levels of temporal and spatial resolution, contrasts made among the frequency distribution alternatives, and recommendations put forth for harnessing the results. Empirical data are used to produce more realistic site-level forecasts than previously employed, such that higher resolution operational studies are possible. This research feeds into a larger work of renewable integration through the links wind power forecasting has with various operational issues, such as stochastic unit commitment and flexible reserve level determination.

17 WIND ENERGY↗

Balancing computation and communication power in power constrained clusters

Systems, apparatuses, and methods for balancing computation and communication power in power constrained environments. A data processing cluster with a plurality of compute nodes may perform parallel processing of a workload in a power constrained environment. Nodes that finish tasks early may be power-gated based on one or more conditions. In some scenarios, a node may predict a wait duration and go into a reduced power consumption state if the wait duration is predicted to be greater than a threshold. The power saved by power-gating one or more nodes may be reassigned for use by other nodes. A cluster agent may be configured to reassign the unused power to the active nodes to expedite workload processing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method and system for providing flexible reserve power for power grid

An optimization-based method and system is disclosed to enable heterogeneous loads and distributed energy resources (DERs) to participate in grid ancillary services, such as spinning and non-spinning reserves, and ramping reserves. The method includes receiving inputs for decision parameters for optimizing an objective for obtaining flexible reserve power, solving the objective for obtaining flexible reserve power, determining a reserve power schedule for a prediction horizon for providing flexible reserve power based on the objective, generating a service bid based on the reserve power schedule for the power grid; and when the service bid is accepted, providing flexible reserve power to the power grid based on the service bid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nighttime chemical evolution of aerosol and trace gases in a power plant plume: Implications for secondary organic nitrate and organosulfate aerosol formation, NO₃ radical chemistry, and N₂O₅ heterogeneous hydrolysis

Chemical evolution of aerosols and trace gases in the Salem Harbor power plant plume was monitored with the DOE G-1 aircraft on the night of July 30-31, 2002. Quasi-Lagrangian sampling in the plume at increasing downwind distances/processing times was guided by a constant-volume tetroon that was released near the power plant at sunset. While no evidence of fly ash particles was found, concentrations of particulate organics, sulfate, and nitrate were higher in the plume than in the nearby background air. These species were internally mixed and the particles were acidic, suggesting that particulate nitrate was in the form of organic nitrate. The enhanced particulate organic and nitrate masses in the plume were inferred to be as secondary organic aerosol, possibly formed from the NO3 radical-initiated oxidation of isoprene and other trace organic gases in the presence of acidic sulfate particles. The enhanced particulate sulfate concentrations observed in the plume were attributed to direct emissions of gaseous SO3/H2SO4 from the power plant. Furthermore, concentration of nucleation mode particles was significantly higher in the plume than in background air, suggesting that some of the emitted H2SO4 had nucleated to form new particles. Spectromicroscopic analyses of particle samples suggested that some sulfate was likely in the form of organosulfates. Constrained Lagrangian model analysis of the aircraft and tetroon observations showed that heterogeneous hydrolysis of N2O5 was negligibly slow. These results have significant implications for several scientific and regulatory issues related to the impacts of power plant emissions on atmospheric chemistry, air quality, visibility, and climate.

54 ENVIRONMENTAL SCIENCES↗

Projecting Power Converter Specific Power Through 2050 for Aerospace Applications

In order to analyze the potential fuel burn benefit from the electrification of aircraft powertrains, it is important to quantify the amount of weight that will be added to the aircraft for each additional component of the electric powertrain. This paper provides a projection of the specific power and efficiency of power converters, (AC-DC, DC-AC, or DC-DC), through the year 2050. Data was first collected on state of the art power converters in multiple application areas, creating a power converter database. Relevant specific powers were added to a set of historical data from 1976-2020, and then three different logistic curves were fit through the historical data to represent S-curve shaped growth through the year 2050. The three curves were differentiated by conservative, nominal, and aggressive assumptions for the year in which the logistic curve begins to bend down towards slower growth. With a 30% knockdown factor accounting for the additional weight required for a high altitude converter, projections range from the aggressive specific power projection of 52.9 kW/kg in 2050 to a much more conservative specific power of 12 kW/kg in which growth is limited due to certifiability concerns. Little historical data was found on converter efficiencies to project efficiency based on historical trends. Projections are based on expert opinion on yearly decreases in converter losses. 2050 projections range from 0.987 to 0.997.

fuel burn↗

Highly Accurate Method for Real-Time Active Power Reserve Estimation for Utility-Scale PV Power Plants: Preprint

This paper applies a robust technique for determining the available power reserve from a curtailed utility-scale photovoltaic (PV) power plant. The proposed technique does not require deploying any additional equipment or sensors and is based only on the addition of new control logic to the existing power plant controller. Also, the proposed method is universally applicable to PV plants with any type of smart inverters and PV modules. Accurate determination of available power is important for using curtailed PV generation as a resource for various types of active power controls, such as spinning reserves and primary and secondary frequency control. For PV plants to be able to maintain the desired regulation range, the plant controller must be able to estimate the available aggregate peak power that all the plant's inverters can produce at any point in time and ensure that the control error stays within the tolerance band at all times. In this paper, we explore a highly accurate control method that uses dedicated inverters within the plant as reference units and evaluates the available aggregate peak power for the whole plant under different cloud variability conditions.

14 SOLAR ENERGY↗

Ion Distribution And Electronic Stopping Power For Au ions In Silicon Carbide

Accurate knowledge of ion distribution and electronic stopping power for heavy ions in light targets is highly desired due to the large errors in prediction by the widely used Stopping and Range of Ions in Matter (SRIM) code. In this study, Rutherford backscattering spectrometry (RBS)and secondary ion mass spectrometry (SIMS) are used as complementary techniques to determine the distribution of Au ions in SiC with energie sfrom 700 keV to 15 MeV. In addition, asingle ion technique with an improved data analysis procedure is applied to measure the electronic stopping power for Au ions in SiC with energies up to ~70 keV/nucleon. Large overestimation of the electronic stopping power is found by SRIM prediction in the low energy regime up to ~50 keV/nucleon. The stopping power data and the ion ranges are crosschecked with each other and a good agreement is achieved.

Environmental Molecular Sciences Laboratory↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗