Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PowerPoint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron Imaging Developments at LANSCE [PowerPoint]

Thermal, epithermal, and high-energy neutrons are available from two spallation sources at the 800-MeV proton accelerator. Improvements in detectors and computing have enabled new capabilities that use the pulsed beam properties at LANSCE; these include amorphous Si (aSi) detectors, intensified charge-coupled device cameras, and micro-channel plates. Applications include water flow in living specimens, inclusions and fission products in uranium oxide, and high-energy neutron imaging using an aSi flat panel with ZnS(Ag) scintillator screen. images of a metal/plastic cylinder from photons, low-energy and high-energy neutrons are compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Actinide Solubility and Speciation in the WIPP [PowerPoint]

The presentation begins with the role and need for nuclear repositories (overall concept, international updates (Sweden, Finland, France, China), US approach and current status), then moves on to the WIPP TRU repository concept (design, current status--safety incidents of February 5 and 14, 2014, path forward), and finally considers the WIPP safety case: dissolved actinide concentrations (overall approach, oxidation state distribution and redox control, solubility of actinides, colloidal contribution and microbial effects). The following conclusions are set forth: (1) International programs are moving forward, but at a very slow and somewhat sporadic pace. (2) In the United States, the Salt repository concept, from the perspective of the long-term safety case, remains a viable option for nuclear waste management despite the current operational issues/concerns. (3) Current model/PA prediction (WIPP example) are built on redundant conservatisms. These conservatisms are being addressed in the ongoing and future research to fill existing data gaps--redox control of plutonium by Fe(0, II), thorium (analog) solubility studies in simulated brine, contribution of intrinsic and biocolloids to the mobile concentration, and clarification of microbial ecology and effects.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status of the Ultracold neutron source upgrade at LANSCE [PowerPoint]

Several slides show the source and flux of ultracold neutrons produced. In summary, an upgraded UCN source has been designed, and parts are currently being fabricated. Nickel phosphorus-coated guides will improve transport to the experiment hall. The source will be installed in the spring of 2016 and commissioned in the fall of 2016.

43 PARTICLE ACCELERATORS↗

Timing Tricks For Complicated Accelerators [PowerPoint]

A brief description of the Los Alamos Neutron Science Center is given first, including static and dynamic scheduling. The principal tricks presented are prescient feed forward and pulser replication. Tricks with flip/flop pulsers are also included.

43 PARTICLE ACCELERATORS↗

Measuring x-ray spectra of flash radiographic sources [PowerPoint]

The x-ray spectra of flash radiographic sources are difficult to measure. The sources measured were Radiographic Integrated Test Stand-6 (370 rad at 1 m; 50 ns pulse) and Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) (550 rad at 1 m; 50 ns pulse). Features of the Compton spectrometer are described, and spectra are shown. Additional slides present data on instrumental calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replacing The Engine In Your Car While You Are Still Driving It [PowerPoint]

The scope of the project included the following: install new network backbone, replace 201 MHz rf tubes, replace low-level rf system, replace timing system, replace industrial I/O system, replace beam synchronous data acquisition system, replace fast protect reporting system, new wire scanner hardware, and new beam position/phase monitor hardware--all of this to be done while continuing to deliver beam to users. Lessons learned, for anyone contemplating a similarly ambitious upgrade: You can’t replace the whole system at once. Some compatibility must be maintained between the old and new systems. Always have a way to fall back. Have sympathy for the operations staff. You will be surprised.

43 PARTICLE ACCELERATORS↗

Random-matrix approach to the statistical compound nuclear reaction at low energies using the Monte-Carlo technique [PowerPoint]

This theoretical treatment of low-energy compound nucleus reactions begins with the Bohr hypothesis, with corrections, and various statistical theories. The author investigates the statistical properties of the scattering matrix containing a Gaussian Orthogonal Ensemble (GOE) Hamiltonian in the propagator. The following conclusions are reached: For all parameter values studied, the numerical average of MC-generated cross sections coincides with the result of the Verbaarschot, Weidenmueller, Zirnbauer triple-integral formula. Energy average and ensemble average agree reasonably well when the width I is one or two orders of magnitude larger than the average resonance spacing d. In the strong-absorption limit, the channel degree-of-freedom ν a is 2. The direct reaction increases the inelastic cross sections while the elastic cross section is reduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗