Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Accelerating Quantum Materials Development with Advances in Transmission Electron Microscopy

Quantum materials are driving a technology revolution in sensing, communication, and computing, while simultaneously testing many core theories of the past century. Materials such as topological insulators, complex oxides, superconductors, quantum dots, color center-hosting semiconductors, and other types of strongly correlated materials can exhibit exotic properties such as edge conductivity, multiferroicity, magnetoresistance, superconductivity, single photon emission, and optical-spin locking. These emergent properties arise and depend strongly on the material’s detailed atomic-scale structure, including atomic defects, dopants, and lattice stacking. In this review, we describe how progress in the field of electron microscopy (EM), including in situ and in operando EM, can accelerate advances in quantum materials and quantum excitations. We begin by describing fundamental EM principles and operation modes. We then discuss various EM methods such as (i) EM spectroscopies, including electron energy loss spectroscopy (EELS), cathodoluminescence (CL), and electron energy gain spectroscopy (EEGS); (ii) four-dimensional scanning transmission electron microscopy (4D-STEM); (iii) dynamic and ultrafast EM (UEM); (iv) complementary ultrafast spectroscopies (UED, XFEL); and (v) atomic electron tomography (AET). We describe how these methods could inform structure–function relations in quantum materials down to the picometer scale and femtosecond time resolution, and how they enable precision positioning of atomic defects and high-resolution manipulation of quantum materials. For each method, we also describe existing limitations to solve open quantum mechanical questions, and how they might be addressed to accelerate progress. Among numerous notable results, our review highlights how EM is enabling identification of the 3D structure of quantum defects; measuring reversible and metastable dynamics of quantum excitations; mapping exciton states and single photon emission; measuring nanoscale thermal transport and coupled excitation dynamics; and measuring the internal electric field and charge density distribution of quantum heterointerfaces- all at the quantum materials’ intrinsic atomic and near atomic-length scale. Finally, we conclude by describing open challenges for the future, including achieving stable sample holders for ultralow temperature (below 10K) atomic-scale spatial resolution, stable spectrometers that enable meV energy resolution, and high-resolution, dynamic mapping of magnetic and spin fields. With atomic manipulation and ultrafast characterization enabled by EM, quantum materials will be poised to integrate into many of the sustainable and energy-efficient technologies needed for the 21st century.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The v 1 -v 2 , v 3 -v 2 , v 1 , and v 3 bands of H 2 16 O: line positions and strengths

High-resolution spectra of H 2 16 O were recorded with a Fourier-transform spectrometer covering transitions in the (100)-(010), (001)-(010), (100)-(000), and (001)-(000) bands. The measured line frequencies were used to determine high accuracy values of rotational energy levels in the (100) and (001) vibrational states. The experimental results provide a more accurate representation of the line positions and strengths than those presently available for these bands.

Fourier-transform↗

Study of alloy disorder in quantum dots through multi-million atom simulations

A tight binding model which includes s, p, d, s orbitals is used to examine the electronic structures of an ensemble of dome-shaped In0.6 Ga0.4 As quantum dots. Given ensembles of identically sized quantum dots, variations in composition and configuration yield a linewidth broadening of less than 0.35 meV, much smaller than the total broadening determined from photoluminescence experiments. It is also found that the computed disorder-induced broadening is very sensitive to the applied boundary conditions, so that care must be taken to ensure proper convergence of the numerical results. Examination of local eigenenergies as functions of position shows similar convergence problems and indicates that an inaccurate resolution of the equilibrium atomic positions due to truncation of the simulation domain may be the source of the slow ground state convergence.

disorder↗

Rapidly-Indexing Incremental-Angle Encoder

Optoelectronic system measures relative angular position of shaft or other device to be turned, also measures absolute angular position after device turned through small angle. Relative angular position measured with fine resolution by optoelectronically counting finely- and uniformly-spaced light and dark areas on encoder disk as disk turns past position-sensing device. Also includes track containing coarsely- and nonuniformly-spaced light and dark areas, angular widths varying in proportion to absolute angular position. This second track provides gating and indexing signal.

Christon, Philip R.↗

AstroPix: ATLAS-Inspired Silicon Pixels for Future Space-Based Gamma-ray Telescopes

Space-based gamma-ray telescopes such as the Fermi Large Area Telescope have used single sided silicon strip detectors to measure the position of incident gamma-rays with high resolution. At lower energies, two dimensional position information within a single detector is required. This talk investigates the use of monolithic CMOS active pixel silicon sensors –AstroPix – as a novel technology for use in future gamma-ray telescopes. Based upon detectors designed for use in the ATLAS detector at the LHC, AstroPix has the potential to maintain the high energy and angular resolution required of a medium-energy gamma-ray telescope while reducing noise with the dual detection and readout capabilities of a CMOS chip. The status of AstroPix development and testing, as well as outlook for application in future telescopes such as the proposed medium-energy gamma-ray telescope AMEGO-X, will be presented.

Amanda L. Steinhebel↗

Evaluation of E3SM Simulated Aerosols and Aerosol‐Cloud Interactions Across GCM and Convection‐Permitting Scales

This paper introduces an Earth system modeling testbed for predicting aerosols and aerosol‐cloud interactions (ACIs) at convection‐permitting scales. Using the Energy Exascale Earth System Model (E3SM) version 2 with a four‐mode Modal Aerosol Module, we conduct simulations at 3.25 km resolution on a regionally refined mesh (RRM) across four regions with distinct aerosol and cloud regimes. Results are compared with the standard 100 km E3SM configuration and evaluated against satellite, aircraft, and ground‐based observations. We find that increasing model resolution improves heavy precipitation simulation but amplifies positive bias in light drizzle at coarse resolution. These resolution‐induced changes affect cloud and aerosol properties to varying degrees across regions. Generally, cloud cover and liquid water path (LWP) show better agreement with satellite retrievals at 3.25 km, though surface‐based comparisons suggest otherwise. Aerosol composition remains poorly represented at both resolutions. The RRM increases Aitken mode aerosol number concentrations via enhanced new particle formation. However, accumulation mode aerosols are decreased at higher resolution as aerosol removals become more efficient. This partially contributes to fewer cloud condensation nuclei (CCN) and lower cloud droplet number concentrations (N d ), which produces larger model biases in some scenarios. These findings suggest that solely increasing horizontal resolution to kilometer scales is insufficient to broadly improve aerosol and cloud predictions without concurrent advancements in physical and chemical process representations. Nonetheless, the RRM moderately improves key ACI relationships such as CCN‐N d correlation, reflecting enhanced aerosol activation representation. The LWP‐N d relationship is also better captured by RRM, suggesting a better characterization of LWP adjustment.

Huang, Meng [Pacific Northwest National Laboratory↗

Measurement resolution of noise directivity patterns from acoustic flight tests

The measurement resolution of noise directivity patterns from acoustic flight tests was investigated. Directivity angle resolution is affected by the data reduction parameters, the aircraft velocity and flyover altitude, and by deviations of the aircraft from the desired flight path. Equations are developed which determine bounds for the lateral and longitudinal directivity angle resolution as a function of the nominal directivity angle. The equations are applied to a flight test data base and the effects of several flight conditions and data reduction parameters on the directivity angle resolution are presented. The maximum directivity angle resolution typically occurs when the aircraft is at or near the overhead position. In general, directivity angle resolution improves with decreasing velocity, increasing altitude, increasing sampling rate, decreasing block size, and decreasing block averages. Deviations from the desired ideal flight path will increase the resolution. For the flight experiment considered in this study, an average of two flyovers were required at each test condition to obtain an acceptable flight path. The ability of the pilot to maintain the flight track improved with decreasing altitude, decreasing velocity, and practice. Due to the prevailing wind conditions, yaw angles of as much as 20 deg were required to maintain the desired flight path.

Conner, David A.↗

Validation of the AMSU-B Bias Corrections Based on Satellite Measurements from SSM/T-2

The NOAA-15 Advanced Microwave Sounding Unit-B (AMSU-B) was designed in the same spirit as the Special Sensor Microwave Water Vapor Profiler (SSM/T-2) on board the DMSP F11-14 satellites, to perform remote sensing of spatial and temporal variations in mid and upper troposphere humidity. While the SSM/T-2 instruments have a 48 km spatial resolution at nadir and 28 beam positions per scan, AMSU-B provides an improvement with a 16 km spatial resolution at nadir and 90 beam positions per scan. The AMSU-B instrument, though, has been experiencing radio frequency interference (RFI) contamination from the NOAA-15 transmitters whose effect is dependent upon channel, geographic location, and current spacecraft antenna configuration. This has lead to large cross-track biases reaching as high as 100 Kelvin for channel 17 (150 GHz) and 50 Kelvin for channel 19 (183 +/-3 GHz). NOAA-NESDIS has recently provided a series of bias corrections for AMSU-B data starting from March, 1999. These corrections are available for each of the five channels, for every third field of view, and for three cycles within an eight second period. There is also a quality indicator in each data record to indicate whether or not the bias corrections should be applied. As a precursor to performing retrievals of mid and upper troposphere humidity, a validation study is performed by statistically analyzing the differences between the F14 SSM/T-2 and the bias corrected AMSU-B brightness temperatures for three months in the spring of 1999.

Kolodner, Marc A.↗

Radio properties of extragalactic IRAS sources

The present study identifies extragalactic sources from the IRAS Faint Source Catalog by position coincidence with radio sources stronger than 25 mJy and lying north of +5 deg on the Green Bank 4.85 GHz sky maps. Published VLA maps, new 4.86 GHz VLA maps made with 15-arcsec resolution, and accurate optical positions are used to confirm 122 of these candidate identifications. Normal and starburst spiral galaxies were found to comprise about 97 percent of the FIR flux-limited sample. Radio-loud 'monsters' with q less than 2.25 dominate the radio emission from about 2 percent of the FIR source sample, and radio-quiet monsters are responsible for the FIR emission from less than about 1 percent of the FIR sample. All of the radio-identified sources are optically identified, mostly with relatively bright nearby galaxies. No evidence was found for any new populations of high-redshift FIR sources, nonthermal sources with steep FIR/optical spectra, or dust-shrouded sources visible only at FIR and radio wavelengths.

Condon, J. J.↗

Building Atomic and Plasmonic Devices via Electron Beams: from Desired Structures to Desired Properties

The evolution of the aberration correction in Scanning Transmission Electron Microscopy (STEM) has enabled multiple advances including high-resolution structural imaging, pm-level position detection of atomic columns, and ~3-5 mV resolution electron energy loss spectroscopy of the chemical and physical functionalities. These developments have further enabled the precise manipulation of the atomic structure of materials, including removal and formation of atomic planes in 3D materials, controlled atomic motion, and even direct atomic assembly of homo- and heteroatomic artificial molecules. Here, we will discuss several recent advances in STEM-EELS automated experiments as applied to quantum and nanoplasmonic systems.

42 ENGINEERING↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

BATSE software for the analysis of the gamma ray burst spatial distribution

The Burst and Transient Source Experiment (BATSE) on the Gamma Ray Observatory (GRO) is designed to study astronomical gamma ray sources and to provide better positional, spectral, and time resolution about these objects than has previously been possible from one experiment. The procedure to be used in the analysis of the gamma ray burst spatial distribution is presented. Data is input from BATSE via the Gamma Ray Burst Catalog (listing individual burst positions, flux values, and associated errors) and the Sky Sensitivity Map (which summarizes observational selection effects in table format). A FORTRAN program generates Monte Carlo burst catalogs, which are models to be compared to the actual distribution. The Monte Carlo models are then filtered through the Sky Sensitivity Map so that they suffer from the same selection effects as the actual catalog data. Additionally, each burst position is converted into a probability distribution to mimic BATSE positional sensitivity. The Burst Catalog, Monte Carlo burst catalog, and Sky Sensitivity Map are then passed onto an IDL program that compares the catalogs for statistical significance. The Sky Sensitivity Map is used to estimate how often each sky area is observed above the minimum flux level in question. Each burst found in this sky area is then weighted according to the frequency with which this sky area is observed. The catalogs are then compared via tests of homogeneity (based on their radial distributions) and isotropy (based upon their angular distributions). The results of the statistical comparisons along with graphs and charts of the summaries, are output from the IDL program for study.

Hakkila, Jon↗

X-ray beam monitoring and wavelength calibration using four-beam diffraction

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BUILD: A community development simulation game, appendix A

The computer based urban decision-making game BUILD is described. BUILD is aimed at: (1) allowing maximum expression of value positions by participants through resolution of intense, task-oriented conflicts: (2) heuristically gathering information on both the technical and social functioning of the city through feedback from participants: (3) providing community participants with access to technical expertise in urban decision making, and to expose professionals to the value positions of the community: and (4) laying the groundwork for eventual development of an actual policy making tool. A brief description of the roles, sample input/output formats, an initial scenario, and information on accessing the game through a time-sharing system are included.

Orlando, J. A.↗

Sub-milliarcsecond determination of pole position using Global Positioning System data

The determination of pole-position variations from the analysis of 23 days of Global Positioning System (GPS) data continuously collected with a globally distributed, 21-station network is discussed. The comparison of the estimated pole positions from these data with results from 11 very long baseline interferometry (VLBI) experiments conducted during this same interval yields weighted root-mean-square differences about the mean differences of 0.5 mas for both X- and Y-pole position estimates from an analysis using single-day arcs, and 1.0 and 0.8 mas from an analysis using three weekly multiday arcs. These results are of sufficient quality that GPS could provide an alternative technique to VLBI and satellite laser ranging for regular monitoring of high-time-resolution variations in the position of the earth's rotation axis.

Herring, Thomas A.↗

Formal Verification of Safety Buffers for Sate-Based Conflict Detection and Resolution

The information provided by global positioning systems is never totally exact, and there are always errors when measuring position and velocity of moving objects such as aircraft. This paper studies the effects of these errors in the actual separation of aircraft in the context of state-based conflict detection and resolution. Assuming that the state information is uncertain but that bounds on the errors are known, this paper provides an analytical definition of a safety buffer and sufficient conditions under which this buffer guarantees that actual conflicts are detected and solved. The results are presented as theorems, which were formally proven using a mechanical theorem prover.

Herencia-Zapana, Heber↗

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.↗