Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Physical Security Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗

Inferring adversarial behaviour in cyber‐physical power systems using a Bayesian attack graph approach

Abstract Highly connected smart power systems are subject to increasing vulnerabilities and adversarial threats. Defenders need to proactively identify and defend new high‐risk access paths of cyber intruders that target grid resilience. However, cyber‐physical risk analysis and defense in power systems often requires making assumptions on adversary behaviour, and these assumptions can be wrong. Thus, this work examines the problem of inferring adversary behaviour in power systems to improve risk‐based defense and detection. To achieve this, a Bayesian approach for inference of the Cyber‐Adversarial Power System (Bayes‐CAPS) is proposed that uses Bayesian networks (BNs) to define and solve the inference problem of adversarial movement in the grid infrastructure towards targets of physical impact. Specifically, BNs are used to compute conditional probabilities to queries, such as the probability of observing an event given a set of alerts. Bayes‐CAPS builds initial Bayesian attack graphs for realistic power system cyber‐physical models. These models are adaptable using collected data from the system under study. Then, Bayes‐CAPS computes the posterior probabilities of the occurrence of a security breach event in power systems. Experiments are conducted that evaluate algorithms based on time complexity, accuracy and impact of evidence for different scales and densities of network. The performance is evaluated and compared for five realistic cyber‐physical power system models of increasing size and complexities ranging from 8 to 300 substations based on computation and accuracy impacts.

Sahu, Abhijeet↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Innovation in Radiological Security, Part 1 of 2 – Using a Cloud Solution to Compress the Timely Detection Model

The design and implementation of new security technologies must account for numerous and complex operational challenges. For example, traditionally isolated systems must now survive amid the proliferation of network connectivity and endure the dynamic environments created by organizations tolerating bring-your-own-device policies. When evaluating the cyber, physical, or cyber-physical security of an asset, a common practice in the security industry is to apply the Timely Detection Model (TDM)—a versatile concept that relates the security functions of detection, delay, and response to the progression of an oppositional force’s attack timeline. If implemented correctly, security enhancements can compress the TDM to offer efficiencies to the stakeholders responsible for adjudicating threat scenarios. The efficiencies gained by the response force allow for more effective protection strategies to be realized. One such enhancement, deployed within the radiological security domain—the Sentry-Remote Monitoring System (Sentry-RMS)—is a stand-alone security system that detects, assesses, and communicates priority alarms as a means of thwarting internal and external threats. The SEntry-RMS CommUnications and REsponse (Sentry-SECURE) platform—an optional feature of the Sentry-RMS—is being developed to facilitate more efficient alarm adjudication by site stakeholders and, if necessary, a faster response by law enforcement. This Cloud-hosted platform receives protected information from deployed Sentry-RMS units and relays it to stakeholders that have vested interests in maintaining an elevated level of situational awareness. Operationally, this enables real-time delivery of high-priority alarm and video imagery directly to an identified response stakeholder, such as local law enforcement or site management, via natively developed mobile applications or full platform integration. The Sentry-SECURE platform, as implemented by the U.S. Department of Energy’s Office of Radiological Security, is an example of an innovative security technology that compresses the TDM by (1) enabling a more efficient time to target and (2) better informing a response force’s predetermined tactics, techniques, and procedures. This paper explores the platform’s operational roles, highlights its principal functions, and presents a use case that demonstrates how the platform provides enhanced situational awareness when adjudicating priority alarms.

Sentry-RMS, Timely Detection Model, Sentry-SECURE↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Testing and Evaluation of Security Response at High-Consequence Nuclear Facilities

High-consequence nuclear facilities are required to implement a physical protection system (PPS) capable of preventing a design basis threat (DBT) adversary from completing radiological sabotage or theft of nuclear material. Response forces are a core component of the PPS. A rigorous testing and evaluation program is required to ensure that the response forces are appropriately trained and equipped and are capable of meeting the regulatory and mission requirements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Interactive Unmanned Aircraft System (UAS) Security Workshop

The goal of this workshop is to role play and walk through various UAS incursion scenarios to: 1. Recognize the complex interactions between physical protection, response, and UAS technologies in a nuclear security event; 2. Identify potential regulatory and legal complications dealing with UAS as aircraft; 3. Identify communication/coordination touch points with facility security and law enforcement; 4. Identify possible physical security and response strategies to help mitigate UAS impact.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Grid Architecture Mapping to Understand Transformation (GAMUT): Concept Definition

The electric power system is undergoing significant transformation driven by changes in the generation mix, increasing reliance on information and communication technologies, evolving customer expectations, and a dynamic cyber-physical environment. To address these challenges, substantial investments will be made over the next decade to create a flexible, affordable, secure, reliable, and resilient electric system. In response, the U.S. Department of Energy's Office of Electricity is developing knowledge management tools aimed at systematically documenting technology pilots and demonstration projects. This initiative seeks to improve understanding of operating contexts, planning steps, and integration requirements for innovative grid technologies. The Department of Energy project leverages Grid Architecture principles to collect and organize insights into the interdependencies, requirements, and capabilities of various grid solutions. By employing a systematic approach, the project aims to perform a feasibility study for the development of a software tool that will support stakeholders, including regulators, transmission and distribution system operators, distributed energy resources aggregators, and technology providers. By offering a systematic, software-based framework to document technologies, understand their benefits and impacts, and inform deployment strategies, the proposed Grid Architecture Mapping to Understand Transformation (GAMUT) Tool is intended to reduce costs, enhance decision-making, and facilitate scaling and effective deployment of new technologies. The feasibility study will evaluate the technical and financial viability of the GAMUT Tool, identifying stakeholder needs and assessing risks and mitigation strategies. Ultimately, the GAMUT team aims to develop an initial minimal viable product, followed by staged improvements, to aid in the modernization of the electric grid, contributing to a more sustainable and resilient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Radiofrequency Tamper Indicating Devices (RFTID) to Enhance Remotely Monitoring the Security of Advanced and Small Modular Reactors (A/SMRs)

A/SMRs will likely be deployed in remote locations that are difficult to access, thereby requiring limited on-site staff. • Vendors are considering remote monitoring as a solution to enhance nuclear security. RFTIDs are a candidate technology for maintaining nuclear security of A/SMRs but need to be evaluated for feasibility and implementation into the wider physical protection system.

O'Dowd, Kevin [Savannah River National Laboratory ↗

Test and Evaluation of Radiofrequency Tamper Indicating Devices for Remote Monitoring of Advanced/Small Modular Reactors

Advanced and small modular reactors (A/SMRs), due to their versatile nature, are likely to be used in remote locations to provide electrical power or other services in regions that are difficult to access or have limited transportation infrastructure. This will result in limited on-site staff, therefore driving A/SMR vendors to consider remote monitoring as a solution to support nuclear security. Maintaining Continuity of Knowledge (CoK) of nuclear material quantities and locations is vital to nuclear security, and remote monitoring of active tamper indicating devices (TIDs) has been well established as a component of International Atomic Energy Agency (IAEA) Safeguards since the early 2000s. Active TIDs, such as radiofrequency TIDs (RFTIDs), immediately alarm upon unauthorized access attempts, promoting timely detection. In contrast, passive TIDs require a surveillance regime and offer delayed detection. Active TIDs deter insiders and enable prompt detection of malicious acts. They can be used on nuclear material containers and controlled entry points like vaults and toolboxes. Therefore, the implementation of RFTIDs into security programs bolsters overall nuclear material control, and provides a visible deterrent, with primary efficacy in mitigating the insider threat and potentially allowing for Security by Design considerations. They are a strong candidate technology for maintaining nuclear security of A/SMRs but need to be evaluated for feasibility and implementation into the wider physical protection system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards intelligent emergency control for large-scale power systems: Convergence of learning, physics, computing and control

Here, this paper has delved into the pressing need for intelligent emergency control in large-scale power systems, which are experiencing significant transformations and are operating closer to their limits with more uncertainties. Learning-based control methods are promising and have shown effectiveness for intelligent power system control. However, when they are applied to large-scale power systems, there are multifaceted challenges such as scalability, adaptiveness, and security posed by the complex power system landscape, which demand comprehensive solutions. The paper first proposes and instantiates a convergence framework for integrating power systems physics, machine learning, advanced computing, and grid control to realize intelligent grid control at a large scale. Our developed methods and platform based on the convergence framework have been applied to a large (more than 3000 buses) Texas power system, and tested with 56 000 scenarios. Our work achieved a 26% reduction in load shedding on average and outperformed existing rule-based control in 99.7% of the test scenarios. The results demonstrated the potential of the proposed convergence framework and DRL-based intelligent control for the future grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Description of the Gas Sampling and Circulation System for the LYNM PE1-A Experiment

A series of multiphysics experiments, referred to as Physics Experiment 1 (PE1) is underway at the U.S. Nevada National Security Site. The PE1 series includes detonations of three underground chemical explosions. As the name implies, there are a number of experiments investigating the signals generated by the explosion. The experiment series objectives are outlined in a report from Lawrence Livermore National Laboratory.1 One of the experiments is a gas migration experiment. Gas tracers were imbedded in the explosives and gas sampling boreholes were installed in the formation in the test bed. Connected to the monitoring points is a circulation system that moves gas to a central measurement location. This report does not describe the gas analysis or collection systems, but rather the circulation system that provides the gas for measurement. Here, we have combined four project documents into a single report that describes the design, build, installation, testing, and operation of the gas sampling network.

42 ENGINEERING↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗

Energy Resilience for Mission Assurance: Agile Co-simulation for Cyber Energy System Security (ACCESS), Model Advancements for Resilience Analysis

Agile Co-simulation for Cyber Energy System Security (ACCESS) is a co-simulation platform developed by Lawrence Livermore National Laboratory (LLNL). The primary high-level use-case for ACCESS is to study existing or new cyber-physical critical infrastructure systems, with a heavy emphasis on 1) systems that utilize communication networks, and 2) studies that seek to understand cyber-related system impacts. ACCESS is currently used for several energy system resilience projects at LLNL. In the Energy Resilience for Mission Assurance (ERMA) project, ACCESS is used in the Modeling for Metric Calculation task (specifically, subtask 4.3, Communications and Cyber Modeling) to model and simulate the cyber and communication system aspects of Defense Critical Electric Infrastructure (DCEI) systems, with a focus on computing specific communication system metrics that can impact system resilience and mission performance. Simulated communication system performance will be fed back to other ERMA system components so that mission performance can be evaluated holistically. This report describes several enhancements to the ACCESS platform that were implemented during the execution of the ERMA project in support of reslience analysis. This includes the addition of new models and subsystems, enhancements to existing models, and integration with external systems. The remainder of this report is structured as follows. In Section 2, a brief background description of the ACCESS platform is provided, including an outline of ACCESS components, example usecases, and a set of communication network resilience metrics that can be computed with ACCESS. Section 3 describes the ACCESS model enhancements for ERMA in detail. Finally, Section 4 briefly outlines future integration opportunities between ACCESS and project participant capabilities identified during the progression of the project.

97 MATHEMATICS AND COMPUTING↗

Energy Resilience for Mission Assurance, Agile Co-simulation for Cyber Energy System Security (ACCESS) Model Advancements for Resilience Analysis (Version 3, July 2023)

Agile Co-simulation for Cyber Energy System Security (ACCESS) is a co-simulation platform developed by Lawrence Livermore National Laboratory (LLNL). The primary high-level use-case for ACCESS is to study existing or new cyber-physical critical infrastructure systems, with a heavy emphasis on 1) systems that utilize communication networks, and 2) studies that seek to understand cyber-related system impacts. ACCESS is currently used for several energy system resilience projects at LLNL. In the Energy Resilience for Mission Assurance (ERMA) project, ACCESS is used in the Mod eling for Metric Calculation task (specifically, subtask 4.3, Communications and Cyber Modeling) to model and simulate the cyber and communication system aspects of Defense Critical Electric Infrastructure (DCEI) systems, with a focus on computing specific communication system metrics that can impact system resilience and mission performance. Simulated communication system per formance will be fed back to other ERMA system components so that mission performance can be evaluated holistically. This report describes several enhancements to the ACCESS platform that were implemented during the execution of the ERMA project in support of reslience analysis. This includes the addition of new models and subsystems, enhancements to existing models, and integration with external systems. The remainder of this report is structured as follows. In Section 2, a brief background description of the ACCESS platform is provided, including an outline of ACCESS components, example use cases, and a set of communication network resilience metrics that can be computed with ACCESS. Section 3 describes the ACCESS model enhancements for ERMA in detail. Finally, Section 4 briefly outlines future integration opportunities between ACCESS and project participant capabilities identified during the progression of the project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LLNL FY2022 Aging and Lifetimes Exit Criteria: Milestone 8118, GC#3

Adhesives and adhesive-bond joints play a critical role in many applications across the national security enterprise. They are ubiquitous and their aging performance can impact the physical and chemical behavior of complex systems. Previously, we have explored the chemical aging behavior of polyurethane adhesives (Halthane 73-18, Halthane 88-3, and Wilethane 44) exposed to varying levels of radiation and identified the primary chemical degradation products. In this work, we expand upon our analysis to understand how the mechanical properties of adhesives-bonded joints behave after radiation exposure.

36 MATERIALS SCIENCE↗