Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

BANYAN. II. Very low mass and substellar candidate members to nearby, young kinematic groups with previously known signs of youth

We present Bayesian Analysis for Nearby Young AssociatioNs II (BANYAN II), a modified Bayesian analysis for assessing the membership of later-than-M5 objects to any of several Nearby Young Associations (NYAs). In addition to using kinematic information (from sky position and proper motion), this analysis exploits 2MASS-WISE color-magnitude diagrams in which old and young objects follow distinct sequences. As an improvement over our earlier work, the spatial and kinematic distributions for each association are now modeled as ellipsoids whose axes need not be aligned with the Galactic coordinate axes, and we use prior probabilities matching the expected populations of the NYAs considered versus field stars. We present an extensive contamination analysis to characterize the performance of our new method. We find that Bayesian probabilities are generally representative of contamination rates, except when a parallax measurement is considered. In this case contamination rates become significantly smaller and hence Bayesian probabilities for NYA memberships are pessimistic. We apply this new algorithm to a sample of 158 objects from the literature that are either known to display spectroscopic signs of youth or have unusually red near-infrared colors for their spectral type. Based on our analysis, we identify 25 objects as new highly probable candidates to NYAs, including a new M7.5 bona fide member to Tucana-Horologium, making it the latest-type member. In addition, we reveal that a known L2γ dwarf is co-moving with a bright M5 dwarf, and we show for the first time that two of the currently known ultra red L dwarfs are strong candidates to the AB Doradus moving group. Several objects identified here as highly probable members to NYAs could be free-floating planetary-mass objects if their membership is confirmed.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-fast non-equilibrium synthesis of cathode materials for Li-ion batteries

Synthesis of cathode materials plays an important role in determining the production efficiency, cost and performance of lithium-ion batteries. However, the conventional synthesis methods always experience a slow heating rate and involve a complicated multi-step reaction process and sluggish reaction dynamics, leading to high energy and long time consuming. Herein, we report a high-temperature shock (HTS) strategy for the ultra-fast synthesis of cathode materials in seconds. The HTS process experiences an ultra-high heating rate, leading to a non-equilibrium reaction and fast reaction kinetics and avoiding high energy and long time consuming. Mainstream cathode materials (such as LiMn 2 O 4 , LiCoO 2 , LiFePO 4 , and Li-rich layered oxide/NiO heterostructured material) are successfully synthesized with pure phases, oxygen vacancies, ultra-small particle sizes and good electrochemical performance. In conclusion, the HTS process not only provides an efficient synthesis approach for cathode materials but also can be extended beyond lithium-ion batteries.

25 ENERGY STORAGE↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2020

This report presents an enhanced performance evaluation of emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2020 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2020. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • HPCS EDG FTS failure probability • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTS failure probability • EPS EDG FTLR failure probability • EPS EDG unavailability • EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Acceleration and sensitivity analysis of lattice kinetic Monte Carlo simulations using parallel processing and rate constant rescaling

Kinetic Monte Carlo (KMC) simulation provides insights into catalytic reactions unobtainable with either experiments or mean-field microkinetic models. Sensitivity analysis of KMC models assesses the robustness of the predictions to parametric perturbations and identifies rate determining steps in a chemical reaction network. Stiffness in the chemical reaction network, a ubiquitous feature, demands lengthy run times for KMC models and renders efficient sensitivity analysis based on the likelihood ratio method unusable. We address the challenge of efficiently conducting KMC simulations and performing accurate sensitivity analysis in systems with unknown time scales by employing two acceleration techniques: rate constant rescaling and parallel processing. We develop statistical criteria that ensure sufficient sampling of non-equilibrium steady state conditions. Our approach provides the twofold benefit of accelerating the simulation itself and enabling likelihood ratio sensitivity analysis, which provides further speedup relative to finite difference sensitivity analysis. As a result, the likelihood ratio method can be applied to real chemistry. We apply our methodology to the water-gas shift reaction on Pt(111).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-D-BRE-05: Prediction of Late Radiation-Induced Proctitis in Prostate Cancer Patients Using Chromosome Aberration and Cell Proliferation Rate

Purpose: Chromosome damage and cell proliferation rate have been investigated as potential biomarkers for the early prediction of late radiationinduced toxicity. Incorporating these endpoints, we explored the predictive power for late radiation proctitis using a machine learning method. Methods: Recently, Beaton et al. showed that chromosome aberration and cell proliferation rate could be used as biomarkers to predict late radiation proctitis (Beaton et al. (2013) Int J Rad Onc Biol Phys, 85:1346–1352). For the identification of radiosensitive biomarkers, blood samples were collected from 10 patients with grade 3 late proctitis along with 20 control patients with grade 0 proctitis. After irradiation at 6 Gy, statistically significant difference was observed between the two groups, using the number of dicentrics and excess fragments, and the number of cells in metaphase 2 (M2). However, Beaton et al. did not show the usefulness of combining these endpoints. We reanalyzed the dataset to investigate whether incorporating these endpoints can increase the predictive power of radiation proctitis, using a support vector machine (SVM). Results: Using the SVM method with the number of fragments and M2 endpoints, perfect classification was achieved. In addition, to avoid biased estimate of the classification method, leave-one-out cross-validation (LOO-CV) was performed. The best performance was achieved when all three endpoints were used with 87% accuracy, 90% sensitivity, 85% specificity, and 0.85 AUC (the area under the receiver operating characteristic (ROC) curve). The most significant endpoint was the number of fragments that obtained 83% accuracy, 70% sensitivity, 90% specificity, and 0.82 AUC. Conclusion: We demonstrated that chromosome damage and cell proliferation rate could be significant biomarkers to predict late radiation proctitis. When these endpoints were used together in conjunction with a machine learning method, the better performance was obtained. However, evaluation for other late radiation toxicities is necessary to elucidate these observations.

60 APPLIED LIFE SCIENCES↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nonlinear Photovoltaic Degradation Rates: Modeling and Comparison Against Conventional Methods

Although common practice for estimating photovoltaic (PV) degradation rate (RD) assumes a linear behavior, field data have shown that degradation rates are frequently nonlinear. This article presents a new methodology to detect and calculate nonlinear RD based on PV performance time-series from nine different systems over an eight-year period. Prior to performing the analysis and in order to adjust model parameters to reflect actual PV operation, synthetic datasets were utilized for calibration purposes. A change-point analysis is then applied to detect changes in the slopes of PV trends, which are extracted from constructed performance ratio (PR) time-series. Once the number and location of change points is found, the ordinary least squares method is applied to the different segments to compute the corresponding rates. The obtained results verified that the extracted trends from the PR time-series may not always be linear and therefore, “nonconventional” models need to be applied. All thin-film technologies demonstrated nonlinear behavior whereas nonlinearity detected in the crystalline silicon systems is thought to be due to a maintenance event. A comparative analysis between the new methodology and other conventional methods demonstrated levelized cost of energy differences of up to 6.14%, highlighting the importance of considering nonlinear degradation behavior

14 SOLAR ENERGY↗

Selecting Appropriate Model Complexity: An Example of Tracer Inversion for Thermal Prediction in Enhanced Geothermal Systems

Abstract A major challenge in the inversion of subsurface parameters is the ill‐posedness issue caused by the inherent subsurface complexities and the generally spatially sparse data. Appropriate simplifications of inversion models are thus necessary to make the inversion process tractable and meanwhile preserve the predictive ability of the inversion results. In this study, we investigate the effect of model complexity on fracture aperture inversion and thermal performance prediction in a field‐scale EGS model. Principal component analysis was used to map the aperture field to a low‐dimensional latent space. The complexity of the inversion model was quantitatively represented by the percentage of total variance in the original aperture fields preserved by the latent space. Tracer, pressure and flow rate data were used to invert for fracture aperture through an ensemble‐based inversion method, and the inferred aperture field was used to predict thermal performance. With an over‐simplified aperture model, ensemble collapse occurred. The inverted aperture models failed to resolve necessary flow and transport features, leading to a biased thermal performance prediction. A complex aperture model involved excessive features and was prone to overinterpreting the inversion data. Both the tracer/pressure/flow rate data reproduction and thermal prediction showed significant uncertainties, making it difficult to properly estimate long‐term thermal performance. Fortunately, our results indicate that there exists an appropriate model complexity which can simultaneously match inversion data and predict thermal performance with an acceptable uncertainty. The quality of the fit of tracer data appears to be a useful indicator of such an appropriate model complexity.

15 GEOTHERMAL ENERGY↗

Design, Development, and Operation of an Integrated Fluidized Carbon Capture Unit Using Polyethylenimine Sorbents

In this paper, we present the design, development, and operation of a reactor system for CO 2 capture. Modifications were implemented to address differences in sorbent from 180 μm Geldart group B to 115 μm Geldart group A material; operational issues were discovered during experimental trials. The major obstacle in system operation was the ability to maintain a constant circulation of a solid sorbent stemming from this change in sorbent material. The system consisted of four fluid beds, through which a polyamine impregnated sorbent was circulated and adsorption, preheat, regeneration, and cooling processes occurred. Pressure transducers, thermocouples, gas flow meters, and gas composition instrumentation were used to characterize thermal, hydrodynamic, and gas adsorption performance in this integrated unit. A series of shakedown tests were performed and the configuration altered to meet the needs of the sorbent performance and achieve desired target capture efficiencies. Methods were identified, tested, and applied to continuously monitor critical operating parameters including solids circulation rate, adsorbed and desorbed CO 2 , solids inventories, and pressures. The working capacity and CO 2 capture efficiency were used to assess sorbent performance while CO 2 closure was used to define data quality and approach to steady-state. Testing demonstrated >90% capture efficiencies and identified the regenerator to be the process step limiting throughput. Sorbent performance was found to be related to the reactant stoichiometry. Finally, a stochastic model with an exponential dependence on the relative CO 2 /amine concentration was used to describe 90% of the variance in the data.

01 COAL, LIGNITE, AND PEAT↗

Flash Recycling of Graphite Anodes

The ever-increasing production of commercial lithium-ion batteries (LIBs) will result in a staggering accumulation of waste when they reach their end of life. A closed-loop solution, with effective recycling of spent LIBs, will lessen both the environmental impacts and economic cost of their use. Presently, <5% of spent LIBs are recycled and the regeneration of graphite anodes has, unfortunately, been mostly overlooked despite the considerable cost of battery-grade graphite. Here, in this work, an ultrafast flash recycling method to regenerate the graphite anode is developed and valuable battery metal resources are recovered. Selective Joule heating is applied for only seconds to efficiently decompose the resistive impurities. The generated inorganic salts, including lithium, cobalt, nickel, and manganese, can be easily recollected from the flashed anode waste using diluted acid, specifically 0.1 M HCl. The flash-recycled anode preserves the graphite structure and is coated with a solid-electrolyte-interphase-derived carbon shell, contributing to high initial specific capacity, superior rate performance, and cycling stability, when compared to anode materials recycled using a high-temperature-calcination method. Life-cycle-analysis relative to current graphite production and recycling methods indicate that flash recycling can significantly reduce the total energy consumption and greenhouse gas emission while turning anode recycling into an economically advantageous process.

36 MATERIALS SCIENCE↗

Transperineal Prostate Core Needle Biopsy: A Comparison of Coaxial Versus Noncoaxial Method in a Randomised Trial

PurposeTo compare the procedural time and complication rate of coaxial technique with those of noncoaxial technique in transperineal prostate biopsy.Materials and MethodsTransperineal prostate biopsy with coaxial (first group, n = 120) and noncoaxial (second group, n = 120) methods was performed randomly in 240 patients. The procedural time was recorded. The level of pain experienced during the procedure was assessed on a visual analogue scale (VAS), and the rate of complications was evaluated in comparison of the two methods.ResultsThe procedural time was significantly shorter in the first group (p < 0.001). In the first group, pain occurred less frequently (p = 0.002), with a significantly lower VAS score being experienced (p < 0.002). No patient had post procedural fever. Haematuria (p = 0.029) and haemorrhage from the site of biopsy (p < 0.001) were seen less frequently in the first group. There was no significant difference in the rate of urethral haemorrhage between the two groups (p = 0.059). Urinary retention occurred less commonly in the first group (p = 0.029). No significant difference was seen in the rate of dysuria between the two groups (p = 0.078).ConclusionsTransperineal prostate biopsy using a coaxial needle is a faster and less painful method with a lower rate of complications compared with conventional noncoaxial technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PV Fleet Performance Data Initiative 2026 Update

We provide an update on the PV Fleet Performance Data Initiative at the 2026 PV Reliability Workshop. Our latest runs incorporate additional data sources and an integrated analysis pipeline run on our Kestrel HPC cluster. Initial degradation findings suggest that single-axis tracked PV systems exhibit higher performance loss rates than fixed-tilt systems, an increase of 0.5 %/yr, almost double. We discuss multiple methods for identifying stuck tracker rows, which are suspected to be a contributor to the enhanced degradation. Through satellite image detection and data-driven approaches we address the topic of identifying when stuck trackers are occuring and to what extent the problem exists. Preliminary results suggest that the increased performance loss detected for the tracked systems would be consistent with stuck tracker rows affecting on the order of 5% - 10% of the system.

14 SOLAR ENERGY↗

Photovoltaic Cleaning Frequency Optimization Under Different Degradation Rate Patterns

Dust accumulation significantly affects the performance of photovoltaic modules and its impact can be mitigated by various cleaning methods. Optimizing the cleaning frequency is essential to minimize the soiling losses and, at the same time, the costs. However, the effectiveness of cleaning lowers with time because of the reduced energy yield due to degradation. Additionally, economic factors such as the escalation in electricity price and inflation can compound or counterbalance the effect of degradation on the soiling mitigation profits. The present study analyzes the impact of degradation, escalation in electricity price and inflation on the revenues and costs of cleanings and proposes a methodology to maximize the profits of soiling mitigation of any system. Here, the energy performance and soiling losses of a 1 MW system installed in southern Spain were analyzed and integrated with theoretical linear and nonlinear degradation rate patterns. The Levelized Cost of Energy and Net Present Value were used as criteria to identify the optimum cleaning strategies. The results showed that the two metrics convey distinct cleaning recommendations, as they are influenced by different factors. For the given site, despite the degradation effects, the optimum cleaning frequency is found to increase with time of operation.

14 SOLAR ENERGY↗

Fourier Analysis of the Multilevel QD Method with {alpha}-Approximation For Time-Dependent Radiative Transfer Problems

Thermal radiation transfer (TRT) problems describe interaction of photon radiation with matter. They are defined by the time-dependent radiative transfer (RT) equation for the specific intensity I coupled with the energy balance (EB) equation. This class of problems is characterised by high dimensionality, multiple scales and strong nonlinearity. In this paper we analyze the multilevel quasi-diffusion (QD) method for solving TRT problems. This is a nonlinear method of moments with exact closures. The QD method enables one to reduce dimensionality of the original radiative transfer problem. It is formulated by a nonlinear system of equations consisting of (i) the high-order RT (HORT) equation for the intensity of photon radiation and (ii) low-order equations for the angular and energy moments of the intensity. The nonlinear closures are formulated by means of stable factors. The low-order problem brings the radiative transfer model to the level of multi-physics equations. The multilevel QD (MLQD) method possesses attractive features for efficient multi-physics coupling. To calculate the high-order RT solution we apply the {alpha}-approximation which assumes that the intensity changes exponentially in time over a time step. The {alpha}-approximation leads to the steady-state RT equation with a modified opacity and enables one to avoid storing the high-dimensional solution from the previous time step. The rate of change is evaluated by the solution of the time-dependent low-order QD (LOQD) equations for moments. We note that the HORT equation in the {alpha}-approximation contains an extra nonlinear term. It affects the iterative behaviour of the MLQD method. The obtained computational results indicated that the rate of convergence is slower compared to the rate when the time-dependent HORT is used to calculate the intensity. In this paper we perform an iterative stability analysis of the MLQD method in a discretized form and analyze convergence of outer (transport) iterations on a time step. We consider multigroup TRT problems in 1D slab geometry. The fully implicit scheme is used to discretize equations in time. The HORT equation is approximated with the method of step characteristics. A finite volume method is applied for spatial discretization of multigroup LOQD equations. The grey (one-group) LOQD equations are algebraically consistent with the multigroup LOQD equations. To perform Fourier analysis a model TRT problem in an infinite homogeneous medium is considered. The system of nonlinear equations of the MLQD method is linearized near an equilibrium solution at some given temperature. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculations vs. measurements of remnant dose rates for SNS spent structures

Residual dose rate measurements were conducted on target vessel #13 and proton beam window #5 after extraction from their service locations. These measurements were used to verify calculation methods of radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation of these structures. Neutronics analyses for predicting residual dose rates were carried out using the transport code MCNPX and the transmutation code CINDER90. For transport analyses complex and rigorous geometry model of the structures and their surrounding are applied. The neutronics analyses were carried out using Bertini and CEM high energy physics models for simulating particles interaction. Obtained preliminary calculational results were analysed and compared to the measured dose rates and overall are showing good agreement with in 40% in average.

Popova, Irina I.↗

Carbon Life Cycle Analysis of CO 2 -EOR for Net Carbon Negative Oil (NCNO) Classification (Final Report)

This final report summarizes the work that was conducted to achieve the project’s general objective of developing a clear and repeatable methodology to determine whether the oil produced in a conventional CO 2 enhanced oil recovery (CO 2 -EOR) operation can be classified as Net Carbon Negative Oil (NCNO). The report also summarizes the reservoir mass accounting methodology and the monitoring, verification, and accounting (MVA) methodology, which are critical elements that support the general objective and were conceived as project goals. Because the purpose is to classify the EOR product (crude oil) and not the EOR project itself, and as the rate of crude oil production varies significantly with time, the methodology uses a novel dynamic carbon lifecycle analysis (d-LCA) that links instant energy demand and associated greenhouse gas (GHG) emissions to instant operational performance. The EOR operational performance is assessed through CO 2 utilization rates, which relate usage of CO 2 to oil production This dynamic method provides a better understanding of the evolution of the environmental impact (CO 2 emissions) and mitigation (geologic CO 2 storage) associated with an expanded carbon capture, utilization and storage (CCUS) system, from start to closure of operations. The dynamic interplay between operational and environmental performance forms the basis of our CCUS technology analysis. The LCA part of the work is meant to complement previous NETL LCA work, and so it focused on EOR/storage efficiency, its variability through time, and the impact of this variability on LCA results. The environmental impact of the CCUS system was assessed for 3 system boundaries: (1) gate-to-gate, (2) gate-to-grave, and (3) cradle-to-grave. The environmental impact was also assessed considering the electricity displacement from other generation facilities. Another goal of our study was to use results to make recommendations on EOR field development strategies that are conducive to producing NCNO. Because field operational strategies have a significant impact on reservoir engineering parameters that affect both CO 2 storage and oil production (e.g., sweep efficiency, flood conformance, fluid saturation distribution), we conducted a scenario analysis that assesses the operational and environmental performance of four common and novel CO 2 -EOR field development strategies. Results show that all CO 2 -EOR evaluated scenarios start operating with a negative carbon footprint and, years into the project, transition into operating with a positive carbon footprint. Having achieved a result that proves that all CO 2 -EOR operations produce NCNO during the first years of production is critical in the context of the urgency of climate change mitigation. Transition points are significantly different in each scenario. ii In a cradle-to-grave CCUS system, if the capture facility displaces a conventional power source and credits are added for displacement, the adverse impact caused by the system expansion not only is reversed but transformed into a significant environmental benefit. The effect of the displacement more than compensates the emissions associated with the electricity generation requirements for the production of CO 2 , as much more electricity will be displaced. Results provide an understanding of the evolution of the system’s net carbon balance of all four field development strategies studied. This information can be useful to CO 2 -EOR operators seeking value in storing more CO 2 through a carbon credit program (e.g., the 45Q federal carbon credit program). Most importantly, this study serves as confirmation that CO 2 -EOR can be operationally designed to both enhance oil production and reduce greenhouse gas emissions to the atmosphere.

02 PETROLEUM↗

Non-Contact Eddy Current Method for Assessing Proton Conductivity in Nafion Membranes

Accurate measurement of proton conductivity in Proton Exchange Membranes (PEMs) is vital for fuel cell performance and durability. This study explores eddy current testing as a non-destructive, non-contact and high-rate quality control (QC) method for measuring Nafion membrane proton conductivity, with potential for high-volume manufacturing applications.

33 ADVANCED PROPULSION SYSTEMS↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗