Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Advanced Signal Decomposition Analysis and Anomaly Detection in Photovoltaic Systems

With the rapid expansion of large-scale photovoltaic (PV) plants, it is paramount for solar stakeholders to understand the reliability and efficiency of their plants to inform maintenance decisions, increase production, and understand the design factors that impact performance. Diagnosing underperformance in PV plants is challenging due to the relatively few monitoring points with respect to the large geographic footprint of the plant. This work introduces a cutting-edge method that transforms the analysis and management of key factors influencing PV plant performance, including performance loss rate (PLR), recoverable soiling, and major system changes. Identifying these factors is critical for deriving actionable insights. Leveraging advanced analytical techniques such as wavelet transformation, robust regression, and extreme point analysis, this approach provides a nuanced understanding of these factors. This method has been tested across two synthetic datasets and one real dataset, consistently surpassing existing benchmarks by achieving a lower median mean absolute error and reduced error variability across all comparable components.

14 SOLAR ENERGY↗

Practical aspects of photovoltaic technology, applications and cost (revised)

The purpose of this text is to provide the reader with the background, understanding, and computational tools needed to master the practical aspects of photovoltaic (PV) technology, application, and cost. The focus is on stand-alone, silicon solar cell, flat-plate systems in the range of 1 to 25 kWh/day output. Technology topics covered include operation and performance of each of the major system components (e.g., modules, array, battery, regulators, controls, and instrumentation), safety, installation, operation and maintenance, and electrical loads. Application experience and trends are presented. Indices of electrical service performance - reliability, availability, and voltage control - are discussed, and the known service performance of central station electric grid, diesel-generator, and PV stand-alone systems are compared. PV system sizing methods are reviewed and compared, and a procedure for rapid sizing is described and illustrated by the use of several sample cases. The rapid sizing procedure yields an array and battery size that corresponds to a minimum cost system for a given load requirement, insulation condition, and desired level of service performance. PV system capital cost and levelized energy cost are derived as functions of service performance and insulation. Estimates of future trends in PV system costs are made.

Rosenblum, L.↗

Design and optimization of a self-deploying PV tent array

A study was performed to design a self-deploying tent shaped PV (photovoltaic) array and optimize the design for maximum specific power. Each structural component of the design was analyzed to determine the size necessary to withstand the various forces it would be subjected to. Through this analysis the component weights were determined. An optimization was performed to determine the array dimensions and blanket geometry which produce the maximum specific power for a given PV blanket. This optimization was performed for both Lunar and Martian environmental conditions. The performance specifications for the array at both locations and with various PV blankets were determined.

Colozza, Anthony J.↗

Houston, We Have a Problem-and a Solution: Solar Performance Initiative Helps Federal Building Boost Rooftop Production

In 2014, the Mickey Leland Federal Building in Houston, Texas installed a 192 kW PV system on top of its parking structure. To monitor and optimize its performance, the General Services Administration, which manages the site, responded to the Federal Energy Management Program’s request for federal agency participation in the Federal Energy Management Program Solar PV Performance Initiative.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems

Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.

14 SOLAR ENERGY↗

High-Performance Computing Based EMT Simulation of Large PV or Hybrid PV Plants

Faults in the transmission grid have led to reduced power generation from power electronics resources that are typically not connected to the faulted transmission line. In many of the cases, partial loss of power is observed within the power electronics resources like large photovoltaic (PV) power plants. This phenomena is not captured in existing simulation models and/or simulators. High-fidelity switched system electromagnetic transient (EMT) dynamic models of PV power plants can improve the fidelity of models available for accurate analysis of the impact on PV plants during simulation of faults. However, these models are extremely computationally expensive and take a long time to simulate. Long simulation times limit the ability to use these models as larger regions are studied in EMT simulations with more power electronics resources. In this paper, numerical simulation algorithms are combined with high-performance computing techniques and applied to the high-fidelity switched system EMT model of PV plants. Using these techniques, a speed-up of up to 58x is obtained, while preserving the accuracy of the simulation at greater than 98%.

Debnath, Suman↗

Assessments and Applications of Terra and Aqua MODIS On-Orbit Electronic Calibration

MODIS has 36 spectral bands located on four focal plane assemblies (FPAs), covering wavelengths from 0.41 to 14.4 micrometers. MODIS bands 1-30 collect data using photovoltaic (PV) detectors and, therefore, are referred to as the PV bands. Similarly, bands 31-36 using photoconductive (PC) detectors are referred to as the PC bands.The MODIS instrument was built with a set of on-board calibrators (OBCs) in order to track on-orbit changes of its radiometric, spatial, and spectral characteristics. In addition, an electronic calibration (ECAL) function can be used to monitor on-orbit changes of its electronic responses (gains). This is accomplished via a series of stair step signals generated by the ECAL function. These signals, in place of the FPA detector signals, are amplified and digitized just like the detector signals. Over the entire mission of both Terra and Aqua MODIS,the ECAL has been performed for the PV bands and used to assess their on-orbit performance. This paper provides an overview of MODIS on-orbit calibration activities with a focus on the PV ECAL, including its calibration process and approaches used to monitor the electronic performance. It presents the results derived and lessons learned from Terra and Aqua MODIS on-orbit ECAL. Also discussed are some of the applications performed with the information provided by the ECAL data.

Xiong, Xiaoxiong↗

EMT Simulation of Large PV Plant & Power Grid for Disturbance Analysis

One of the challenges faced during the analysis of various disturbances with inverter-based resources is the ability to replicate the same disturbance in simulations. The main issue arises from lack of electromagnetic transient (EMT) models and adequate fidelity of models. To overcome this problem, in this paper, EMT simulation of power grid and one of the affected photovoltaic (PV) plants is performed to replicate the observations during the Angeles Forest disturbance in 2018. The processes to (i) develop the EMT model of the power grid from traditional transient stability (TS) data, and (ii) develop high-fidelity EMT model of PV plant from data collected on a PV plant are described in the paper. The requirements in the high-fidelity EMT model of the PV plant are also described. Finally, simulation of the Angeles Forest disturbance is performed and similar simulation results (as compared to the observed disturbances) are observed.

Debnath, Suman↗

Understanding Bifacial Photovoltaic's Potential

The performance of bifacial PV systems depends greatly on the installed conditions. Previous simulations and results have shown very high bifacial gain improvement, but this may not be the case for all conditions, particularly for large-scale systems with self-shading, lower-cost PV modules (PERC) which might have lower bifaciality coefficient, and field deployments over natural ground cover. But not to worry! Financial models indicate that even with these lower performance conditions, and with bifacial gain of 4%-7%, bifacial modules can still provide improved LCOE.

bifacial↗

Dataset for Evaluation of Extreme Weather Impacts on Utility-Scale Photovoltaic Plant Performance in the United States

This dataset is a fusion of three data types (operations and maintenance tickets, weather data, and production data) that was used to support machine learning analysis and evaluation of drivers for low performance at photovoltaic (PV) sites during compound, extreme weather events. After being processed with machine learning, the data was used in the "Evaluation of Extreme Weather Impacts on Utility-scale Photovoltaic Plant Performance in the United States" manuscript. Additional details are captured in the associated manuscript.

AI↗

DuraMAT Technology Scouting Report: Assessing Module Reliability Risks Associated with Projected Technological Changes

Maintaining the reliability of photovoltaic (PV) modules in the face of rapidly changing technology is critical to maximizing solar energy's contribution to global decarbonization. Our presentation describes expected changes in PV technology and their impacts on performance and reliability. We leverage PV market reports, interviews with PV researchers and other industry stakeholders, and peer-reviewed literature to narrow the multitude of possible changes into a manageable set of 11 impactful trends likely to be incorporated in near-term crystalline-silicon module designs. We group the trends into four categories (module architecture, interconnect technologies, bifacial modules, and cell technology) and explore the drivers behind the changes, their interactions, and associated reliability risks and benefits. Our analysis identifies specific areas that would benefit from accelerating the PV reliability learning cycle, to assess emerging module products and designs more accurately. We recommend that researchers continue tracking module technologies and their reliability implications so efforts can be focused on the most impactful trends. As the rapid technological turnover continues, it is also critical to incorporate fundamental knowledge into models that can predict module reliability. Predictive capabilities complete the PV reliability learning cycle-reducing the time required to assess new designs and mitigating the risks associated with large-scale deployment of new products.

bifacial↗

Interactive Educational Tool for Turbofan and Afterburning Turbojet Engines

A workstation-based, interactive educational computer program has been developed at the NASA Lewis Research Center to aid in the teaching and understanding of turbine engine design and analysis. This tool has recently been extended to model the performance of two-spool turbofans and afterburning turbojets. The program solves for the flow conditions through the engine by using classical one-dimensional thermodynamic analysis found in various propulsion textbooks. Either an approximately thermally perfect or calorically perfect gas can be used in the thermodynamic analysis. Students can vary the design conditions through a graphical user interface; engine performance is calculated immediately. A variety of graphical formats are used to present results, including numerical results, moving bar charts, and student-generated temperature versus entropy (Ts), pressure versus specific volume (pv), and engine performance plots. The package includes user-controlled printed output, restart capability, online help screens, and a browser that displays teacher-prepared lessons in turbomachinery. The program runs on a variety of workstations or a personal computer using the UNIX operating system and X-based graphics. It is being tested at several universities in the midwestern United States; the source and executables are available free from the author.

Benson, Thomas J.↗

A Data-Driven Method for Estimating Behind-the-Meter Photovoltaic Generation in Hawaii

Due to the increasing penetration of distributed behind-the-meter photovoltaic (PV) systems and the installed utility revenue metering limited to monitoring only the net power import/export of the household, it is increasingly challenging for utilities to effectively plan and operate the grid. This paper proposes a methodology that estimates behind-the-meter PV generation using a selected subset of monitored PV systems. It is a data-driven approach, and the PV output is estimated utilizing a statistic regression model. A Minimum Redundancy Maximum Relevance (MRMR) algorithm is applied to preselect the optimal subset of the monitored PV systems. The performance of this approach is compared with a spatial interpolation method and a model-based approach. The proposed method is validated using high-resolution meter data recorded from 18 residential rooftop PV systems located on the island of Maui, Hawaii.

Data-driven modeling↗

Individual Pressure Vessel (PV) and Common Pressure Vessel (CPV) Nickel-Hydrogen Battery Performance Under LEO Cycling Conditions

LEO life cycle testing of Individual Pressure Vessel (PV) and Common Pressure Vessel (CPV) nickel-hydrogen cell packs have been sponsored by the NASA Aerospace Flight Battery Program. The cell packs have cycled under both 35% and 60% depth-of- discharge and temperature conditions of -5 C and +lO C. The packs have been on test since as early as 1992 and have generated a substantial database. This report will provide insight into performance trends as a function of the specific cell configuration and manufacturer for eight separate nickel-hydrogen battery cell packs.

Miller, Thomas B.↗

PV CAMPER (Progress Report)

The objective of the Photovoltaic Collaborative to Advance Multi-climate and Performance Research (PVCAMPER) is to create a multi-climate research platform similar to the US DOE Regional Test Center (RTC) program. Overall, the goal is to foster collaborative research and to build an international organization dedicated to sharing data and exchanging best practices related to PV performance.

14 SOLAR ENERGY↗

SEIN: Breaking Barriers Resilient Energy System Analysis [Slides]

The Solar Energy Innovation Network (SEIN) is a collaborative research program that supports multi-stakeholder teams in researching and sharing solutions to real-world challenges associated with solar energy adoption. The Breaking Barriers project was selected to participate in the Solar Energy Innovation Network, Round 2, and was led by Groundswell, a D.C.-based clean energy project developer. The Breaking Barriers team included Partnership for Southern Equity, Atlanta University Center campus facility managers and professors, the City of Atlanta's Neighborhood Planning Unit T, and Georgia Power Company. The project aimed to design and construct innovative urban energy resiliency hubs integrating microgrid technology, solar generation, and energy storage in Atlanta colleges and communities. The hubs will help these historically Black colleges and universities (HBCUs) and the energy-burdened broader community in West Atlanta be more resilient, in addition to informing new course curricula at Atlanta University Center campuses. With many possible options for the system's battery size, the Breaking Barriers team needed insight into the relationships between BESS size, economic performance, and resilience at Spelman College's Manley Center. These insights are crucial for entering procurement negotiations with project developers, establishing resilience capabilities that the HBCU campuses can plan around, and guiding the team's fundraising targets. This analysis includes estimates of PV and battery performance, costs, savings, and resilience for multiple battery sizes. In order to provide power during a grid outage, the resilient energy system also needs to be connected to the Manley Center in a safe and island-able manner (electrically isolated from the grid). Analysis of potential electrical configurations and estimated setup costs is key to successfully entering a required interconnection agreement with Georgia Power, as well as informing requests for engineering firms to construct the system. This analysis includes conceptual options and rough order of magnitude cost estimates for electrically interconnecting the resilient energy system to the Manley Center and the grid. The Breaking Barriers team used this analysis to select preferred system characteristics and design for the resilient energy system.

14 SOLAR ENERGY↗

Cost and Performance of Distributed Photovoltaic Systems

Lifetime Cost and Performance (LCP) model assists in design of Photovoltaic (PV) systems. LCP simulation of performance, cost and revenue streams associated with distributed PV power systems. Provides user with substantial flexibility in specifying technical and economic environment of PV application.

Borden, C. S.↗

Effect of training on blood volume and plasma hormone concentrations in the elderly

The purpose of this investigation was to determine the effects of 6 months of endurance training on resting plasma (PV) and blood volume (BV), and resting hormone and electrolyte concentrations in the elderly. Thirty-eight elderly men and women (ages 60-82 yr) were assigned to endurance exercise training (N = 29) or to control (N = 9) groups. Resting plasma levels of adrenocorticotropic hormone, vasopressin, aldosterone, norepinephrine, epinephrine, sodium, potassium, and protein were measured at the start (T1) and end (T2) of 26 wk of training. PV measurement was performed using the Evan's blue dye technique. Endurance training consisted of uphill treadmill walking or stairclimbing exercise 3 times.wk-1, 30-45 min.d-1, at 75-84% of maximal heart rate reserve. The exercise group increased VO2max by 11.2% (P < or = 0.05) and increased resting PV and BV by 11.2% and 12.7% (P < or = 0.05), respectively. Hormone and electrolyte levels in the exercise group remained unchanged; all variables were unchanged in the control group. These results are similar to findings in younger individuals. Because plasma hormone concentrations were maintained despite a chronically elevated BV, endurance training in healthy, elderly subjects may be associated with a resetting of volume receptors.

Clinical Trial↗