Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROTON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SU-C-204-04: Patient Specific Proton Stopping Powers Estimation by Combining Proton Radiography and Prior-Knowledge X-Ray CT Information

Purpose: The material relative stopping power (RSP) uncertainty is the highest contributor to the range uncertainty in proton therapy. The purpose of this work is to develop a robust and systematic method that yields accurate, patient specific, RSP by combining 1) pre-treatment x-ray CT and 2) daily proton radiograph of the patient. Methods: The method is formulated as a linear least-square optimization problem (min||Ax-B||2). The parameter A represents the pathlength crossed by the proton in each material. The RSPs for the materials (water equivalent thickness (WET)/physical thickness) are denoted by x. B is the proton radiograph expressed as WET crossed. The problem is minimized using a convex-conic optimization algorithm with xi<xi+1 constraint. The Gammex RMI-465 phantom, with 13 material inserts, is used to investigate the optimal RSPs. The proton radiograph (B) is produced using Geant4 simulation. The matrix A is computed by calculating proton trajectories through the CT with the cubic-spline approach. Geant4 RSPs are used as reference and the clinical HU-RSP calibration curve is used as comparison. The convergence is investigated as a function of the number of angles and protons used. The radiographs angle which yield the most accurate RSPs are investigated. Results: Optimization with 9 angles and 104 protons/angle yields precise RSP (<0.75%) for all materials, except plastic lung (1.5%). Average deviation relative to Geant4 RSP is 0.5% and 3.5% using HU-RSP. Using more than two angles or more than 4×103 proton does not further increase the RSP estimate accuracy. The insert distance to the beam initial plane is related to the RSP error for this insert material. Specific filters are applied on the proton angle and energy loss to remove nuclear interaction artefacts. Conclusion: The proposed formulation of the problem with prior knowledge x-ray CT demonstrates serious potential to increase the accuracy of present RSP estimates.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-01: Acoustic Range Verification of Proton Beams: Simulation of Heterogeneity and Clinical Proton Pulses

Purpose: Through simulation, to assess acoustic-based range verification of proton beams (protoacoustics) under clinical conditions. Methods: Pressure waves generated by the energy deposition of a 150 MeV, 8 mm FWHM pulsed pencil proton beam were numerically simulated through two Methods: 1) For a homogeneous water medium, an analytical wave-equation solution was used to calculate the time-dependent pressure measured at detector points surrounding the proton Bragg peak. 2) For heterogeneity studies, a CT tissue image was used to calculate the proton dose deposition and define the acoustic properties of the voxels through which numerical pressure wave propagation was simulated with the k-Wave matlab toolbox. The simulations were used to assess the dependence of the acoustic amplitude and range-verification accuracy on proton pulse rise time and tissue heterogeneity. Results: As the proton pulse rise time is increased from 1 to 40 µs, the amplitude of the expected acoustic emission decreases (a 60% drop distal to the Bragg peak), the central frequency of the expected signal decreases (from 45 to 6 kHz), and the accuracy of the range-verification decreases (from <1 mm to 16 mm at 5 cm distal to the Bragg peak). For a 300 nA pulse, the expected pressure range is on the order of 0.1 Pa, which is observable with commercial detectors. For the heterogeneous medium, our test case shows that pressure waves emitted by an anterior pencil beam directed into the abdomen and detected posteriorly can determine the Bragg peak range to an accuracy of <2mm for a 1 µs proton pulse. Conclusion: For proton pulses with fast rise-times, protoacoustics is a promising potential method for monitoring penetration depth through heterogeneous tissue. The loss of range-verification accuracy with increasing rise-times, however, suggests the need for comparisons to modeling to improve accuracy for slower cyclotron proton sources.

07 ISOTOPE AND RADIATION SOURCES↗

Beyond the proton drip line: Bayesian analysis of proton-emitting nuclei

The limits of the nuclear landscape are determined by nuclear binding energies. Beyond the proton drip lines, where the separation energy becomes negative, there is not enough binding energy to prevent protons from escaping the nucleus. Predicting properties of unstable nuclear states in the vast territory of proton emitters poses an appreciable challenge for nuclear theory as it often involves far extrapolations. In addition, significant discrepancies between nuclear models in the proton-rich territory call for quantified predictions. With the help of Bayesian methodology, we mix a family of nuclear mass models corrected with statistical emulators trained on the experimental mass measurements, in the proton-rich region of the nuclear chart. Separation energies were computed within nuclear density functional theory using several Skyrme and Gogny energy density functionals. We also considered mass predictions based on two models used in astrophysical studies. Quantified predictions were obtained for each model using Bayesian Gaussian processes trained on separation-energy residuals and combined via Bayesian model averaging. Here, we obtained a good agreement between averaged predictions of statistically corrected models and experiment. In particular, we quantified model results for one- and two-proton separation energies and derived probabilities of proton emission. This information enabled us to produce a quantified landscape of proton-rich nuclei. The most promising candidates for two-proton decay studies have been identified. Finally, the methodology used in this work has broad applications to model-based extrapolations of various nuclear observables. It also provides a reliable uncertainty quantification of theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator

Purpose: To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up to 221 MeV. Methods: The spot scanning beam nozzle is modeled using TOPAS code, a simulation tool based on Geant4.9.6. The model contained a beam pipe vacuum window, a beam profile monitor, a drift chamber, two plane-parallel ionization chambers, and a spot-position monitor consisted of a multiwire ionization chamber. A water phantom is located with its upstream surface at the isocenter plane. The initial proton beam energy and anglar deflection are modeled using a Gaussian distribution with FWHM (Full Widths at Half Maximum) deponding on its beam energy. The phase space file (PSF) on a virtual surface located at the center between the two magnets is recorded. PSF is used to analyze the pencil beam features and offset the pencil beam position. The source model parameters are verificated by fitting the simulated Result to the measurement. Results: The simulated percentage depth dose (PDD) and lateral profiles of scanning pencil beams of various incident proton energies are verificated to the measurement. Generally the distance to agreement (DTA) of Bragg peaks is less than 0.2cm. The FWHM of Gaussian anglar distribution was adjusted to fit the lateral profile difference between the simulation and the measurement to less than 2∼3cm. Conclusion: A Monte Carlo model of a spot scanning proton beam was bullt based on a synchrotron proton therapy accelerator. This scanning pencil beam model will be as a block to build the broad proton beam as a proton TPS dose verification tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-EF-303-09: Proton-Acoustic Range Verification in Proton Therapy

Purpose: We investigated proton-acoustic signals detection for range verification with current ultrasound instruments in typical clinical scenarios. Using simulations that included a realistic noise model, we determined the theoretical minimum dose required to generate detectable proton-acoustic signals. Methods: An analytical model was used to calculate the dose distributions and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. The acoustic waves propagating from the Bragg peak were modeled by the general 3D pressure wave equation and convolved with Gaussian kernels to simulate various proton pulse widths (0.1 – 10 ms). A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth band-pass filter, and ii) randomly generated noise based on a model of thermal noise in the transducer. The signal-to-noise ratio was calculated, determining the minimum number of protons and dose required per pulse. The maximum spatial resolution was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer center frequency (70–380 kHz). The minimum number of protons were on the order of 0.6–6 million per pulse, leading to 3–110 mGy dose per pulse at the Bragg peak, depending on the spot size. The acoustic signal consisted of lower frequencies for wider pulses, leading to lower noise levels, but also worse spatial resolution. The resolution was 1-mm for a 0.1-µs pulse width, but increased to 5-mm for a 10-µs pulse width. Conclusion: We have established minimum dose detection limits for proton-acoustic range validation. These limits correspond to a best case scenario with a large detector with no losses and only detector thermal noise. Feasible proton-acoustic range detection will require at least 10{sup 7} protons per pulse and pulse widths ≤ 1-µs.

60 APPLIED LIFE SCIENCES↗

Varying stopping and self-focusing of intense proton beams as they heat solid density matter

Transport of intense proton beams in solid-density matter is numerically investigated using an implicit hybrid particle-in-cell code. Both collective effects and stopping for individual beam particles are included through the electromagnetic fields solver and stopping power calculations utilizing the varying local target conditions, allowing self-consistent transport studies. Two target heating mechanisms, the beam energy deposition and Ohmic heating driven by the return current, are compared. The dependences of proton beam transport in solid targets on the beam parameters are systematically analyzed, i.e., simulations with various beam intensities, pulse durations, kinetic energies, and energy distributions are compared. The proton beam deposition profile and ultimate target temperature show strong dependence on intensity and pulse duration. A strong magnetic field is generated from a proton beam with high density and tight beam radius, resulting in focusing of the beam and localized heating of the target up to hundreds of eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reversible Heterolytic Cleavage of the H-H Bond by Molybdenum Complexes: Controlling the Dynamics of Exchange Between Proton and Hydride

Controlling the heterolytic cleavage of the H-H bond of dihydrogen is critically important in catalytic hydrogenations and in the catalytic oxidation of H2. We show how the rate of reversible heterolytic cleavage of H2 can be controlled over nearly four orders of magnitude at 25 °C, from 2.1 × 103 s-1 to ≥107 s-1. Bifunctional Mo complexes, [CpMo(CO)(κ3-P2N2)]+ (P2N2 = 1,5-diaza-3,7-diphosphacyclooctane with alkyl/aryl groups on N and P), have been developed for heterolytic cleavage of H2 into a proton and a hydride, akin to Frustrated Lewis Pairs. The H-H bond cleavage is enabled by the basic amine in the second coordination sphere. The products of heterolytic cleavage of H2, Mo hydride complexes bearing protonated amines, [CpMo(H)(CO)(P2N2H)]+, were characterized by spectroscopic studies and by X-ray crystallography. Variable temperature 1H, 15N and 2-D 1H-1H ROESY NMR spectra indicated rapid exchange of the proton and hydride. The exchange rates are in the order [CpMo(H)(CO)(PPh2NPh2H)]+ > [CpMo(H)(CO)(PtBu2NPh2H)]+ > [CpMo(H)(CO)(PPh2NBn2H)]+ > [CpMo(H)(CO)(PtBu2NBn2H)]+ > [CpMo(H)(CO)(PtBu2NtBu2H)]+. The pKa values determined in acetonitrile range from 9.3 to 17.7, and show a linear correlation with the logarithm of the exchange rates. Thus the exchange dynamics are controlled through the relative acidity of the [CpMo(H)(CO)(P2N2H)]+ and [CpMo(H2)(CO)(P2N2)]+ isomers, providing a design principle for controlling heterolytic cleavage of H2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of boosted proton energies through proton radiography of target normal sheath acceleration fields in the multi-ps regime

Multi-kilojoule, multi-picosecond short-pulse lasers, such as the National Ignition Facility-Advanced Radiographic Capability laser and the OMEGA-Extended Performance laser, which have been constructed over the last two decades, enable exciting opportunities to produce high-brightness, high-energy laser-driven proton sources for applications in high-energy-density science like proton fast ignition for inertial fusion energy, particle radiography, and materials science studies. Results on these platforms have demonstrated enhanced accelerated proton energies and electron temperatures when compared to established scaling laws. Recent work has developed a new scaling for proton TNSA in the multi-ps regime. However, this new physics in the multi-ps regime motivates the need to understand the origin of the enhancement in proton energies. Toward this goal, here this work presents the first measurements of the TNSA accelerating sheath field in the multi-ps regime for pulse durations of 0.6, 5, and 10 ps. This measurement was achieved by using a separate TNSA proton source to radiograph the spatiotemporal profile of the accelerating sheath that is responsible for proton acceleration. The use of stacked radiochromic film detectors allows for a discrete time profile of the radiographs, thus enabling the measurement of the temporal and spatial evolution of the accelerating field. In performing this measurement, we extract quantities such as the sheath strength as a function of time and pulse duration, which shows that longer pulse durations sustain a stronger electric field for a longer duration when compared to sub-ps laser pulses, which may enable the observed boosted proton energies and proton conversion efficiencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton radius from electron scattering data

Background: The proton charge radius extracted from recent muonic hydrogen Lamb shift measurements is significantly smaller than that extracted from atomic hydrogen and electron scattering measurements. The discrepancy has become known as the proton radius puzzle. Purpose: In an attempt to understand the discrepancy, we review high-precision electron scattering results from Mainz, Jefferson Lab, Saskatoon and Stanford. Methods: We make use of stepwise regression techniques using the F-test as well as the Akaike information criterion to systematically determine the predictive variables to use for a given set and range of electron scattering data as well as to provide multivariate error estimates. Results: Starting with the precision, low four-momentum transfer (Q 2 ) data from Mainz (1980) and Saskatoon (1974), we find that a stepwise regression of the Maclaurin series using the F-test as well as the Akaike information criterion justify using a linear extrapolation which yields a value for the proton radius that is consistent with the result obtained from muonic hydrogen measurements. Applying the same Maclaurin series and statistical criteria to the 2014 Rosenbluth results on GE from Mainz, we again find that the stepwise regression tends to favor a radius consistent with the muonic hydrogen radius but produces results that are extremely sensitive to the range of data included in the fit. Making use of the high-Q 2 data on G E to select functions which extrapolate to high Q 2 , we find that a Pad´e (N = M = 1) statistical model works remarkably well, as does a dipole function with a 0.84 fm radius, G E (Q 2 ) = (1 + Q 2 /0.66 GeV 2 ) -2 . Conclusions: Rigorous applications of stepwise regression techniques and multivariate error estimates result in the extraction of a proton charge radius that is consistent with the muonic hydrogen result of 0.84 fm; either from linear extrapolation of the extreme low-Q 2 data or by use of the Pad´e approximant for extrapolation using a larger range of data. Thus, based on a purely statistical analysis of electron scattering data, we conclude that the electron scattering result and the muonic hydrogen result are consistent. Lastly, it is the atomic hydrogen results that are the outliers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric properties of a proton beamline dedicated to the treatment of ocular disease

Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systems and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong dependence on range (up to 4%/mm). A linear increase in dose/MU as a function of instantaneous MU rate is observed. The dose/MU model describes the measurements with an accuracy of ±2%. Neutron dose is found to be 146 ± 102 μSv/Gy at the contralateral eye and 19 ± 13 μSv/Gy at the chest. Conclusions: Measurements show the proton eyeline meets the requirements to effectively treat ocular disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-EF-303-10: Single- Detector Proton Radiography as a Portal Imaging Equivalent for Proton Therapy

Purpose: In proton therapy, patient alignment is of critical importance due to the sensitivity of the proton range to tissue heterogeneities. Traditionally proton radiography is used for verification of the water-equivalent path length (WEPL), which dictates the depth protons reach. In this work we propose its use for alignment. Additionally, many new proton centers have cone-beam computed tomography in place of beamline X-ray imaging and so proton radiography offers a unique patient alignment verification similar to portal imaging in photon therapy. Method: Proton radiographs of a CIRS head phantom were acquired using the Beam Imaging System (BIS) (IBA, Louvain-la-Neuve) in a horizontal beamline. A scattered beam was produced using a small, dedicated, range modulator (RM) wheel fabricated out of aluminum. The RM wheel was rotated slowly (20 sec/rev) using a stepper motor to compensate for the frame rate of the BIS (120 ms). Dose rate functions (DRFs) over two RM wheel rotations were acquired. Calibration was made with known thicknesses of homogeneous solid water. For each pixel the time width, skewness and kurtosis of the DRFs were computed. The time width was used to compute the object WEPL. In the heterogeneous phantom, the excess skewness and excess kurtosis (i.e. difference from homogeneous cases) were computed and assessed for suitability for patient set up. Results: The technique allowed for the simultaneous production of images that can be used for WEPL verification, showing few internal details, and excess skewness and kurtosis images that can be used for soft tissue alignment. These latter images highlight areas where range mixing has occurred, correlating with phantom heterogeneities. Conclusion: The excess skewness and kurtosis images contain details that are not visible in the WET images. These images, unique to the time-resolved proton radiographic method, could be used for patient set up according to soft tissues.

60 APPLIED LIFE SCIENCES↗

Direct simulation of proton-coupled electron transfer across multiple regimes

The coupled transfer of electrons and protons is a central feature of biological and molecular catalysis, yet fundamental aspects of these reactions remain poorly understood. In this study, we extend the ring polymer molecular dynamics (RPMD) method to enable direct simulation of proton-coupled electron transfer (PCET) reactions across a wide range of physically relevant regimes. In a system-bath model for symmetric, co-linear PCET in the condensed phase, RPMD trajectories reveal distinct kinetic pathways associated with sequential and concerted PCET reaction mechanisms, and it is demonstrated that concerted PCET proceeds by a solvent-gating mechanism in which the reorganization energy is mitigated by charge cancellation among the transferring particles. We further employ RPMD to study the kinetics and mechanistic features of concerted PCET reactions across multiple coupling regimes, including the fully non-adiabatic (both electronically and vibrationally non-adiabatic), partially adiabatic (electronically adiabatic, but vibrationally non-adiabatic), and fully adiabatic (both electronically and vibrationally adiabatic) limits. Comparison of RPMD with the results of PCET rate theories demonstrates the applicability of the direct simulation method over a broad range of conditions; it is particularly notable that RPMD accurately predicts the crossover in the thermal reaction rates between different coupling regimes while avoiding a priori assumptions about the PCET reaction mechanism. Finally, by utilizing the connections between RPMD rate theory and semiclassical instanton theory, we show that analysis of ring-polymer configurations in the RPMD transition path ensemble enables the a posteriori determination of the coupling regime for the PCET reaction. This analysis reveals an intriguing and distinct 'transient-proton-bridge' mechanism for concerted PCET that emerges in the transition between the proton-mediated electron superexchange mechanism for fully non-adiabatic PCET and the hydrogen atom transfer mechanism for partially adiabatic PCET. Taken together, these results provide a unifying picture of the mechanisms and physical driving forces that govern PCET across a wide range of physical regimes, and they raise the possibility for PCET mechanisms that have not been previously reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A technique for extending by ∼10{sup 3} the dynamic range of compact proton spectrometers for diagnosing ICF implosions on the National Ignition Facility and OMEGA

Wedge Range Filter (WRF) proton spectrometers are routinely used on OMEGA and the NIF for diagnosing ρR and ρR asymmetries in direct- and indirect-drive implosions of D{sup 3}He-, D{sub 2}-, and DT-gas-filled capsules. By measuring the optical opacity distribution in CR-39 due to proton tracks in high-yield applications, as opposed to counting individual tracks, WRF dynamic range can be extended by 10{sup 2} for obtaining the spectral shape, and by 10{sup 3} for mean energy (ρR) measurement, corresponding to proton fluences of 10{sup 8} and 10{sup 9} cm{sup −2}, respectively. Using this new technique, ρR asymmetries can be measured during both shock and compression burn (proton yield ∼10{sup 8} and ∼10{sup 12}, respectively) in 2-shock National Ignition Facility implosions with the standard WRF accuracy of ±∼10 mg/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-J-02: Developing a Phenomenological Model of the Proton Trajectory Within a Heterogeneous Medium Required for Proton Imaging

Purpose: To develop an accurate phenomenological model of the cubic spline trajectory (CST) estimate of the proton path, accounting for the initial proton energy and water equivalent thickness (WET) traversed. Methods: Geant4 Monte Carlo (MC) simulations were used to calculate the path of protons crossing various slabs (5–30 cm WET) of different material (LN300, water and CB2–50% CaCO3) for a range of initial energies (150–330MeV). For each MC trajectory, CST was constructed based on the proton entrance and exit information and compared with the MC using the root mean square (RMS) metric. The CST path is dependent on the direction vector magnitudes (|P0,1|). First, |P0,1| is set to the proton path length. Then, a factor Λ is introduced to modify |P0,1|. The factor is varied to minimize the RMS with MC paths for every configuration. Finally, a set of Λopt factors that minimizes the RMS is presented. These are dependent on the ratio between WET and water equivalent path length (WEPL). The resolution along the path is investigated with a set of slabs. MTF analysis is performed on proton radiographs of a line-pair phantom reconstructed using the CST trajectories (Λopt and Λ1). Results: Λopt was fitted to the ratio of WET/WEPL using a power function (Y=1-AXB where A=0.36, B=4.07). The RMS deviation calculated along the path, between the CST and the MC path, increases with the WET. The increase is larger when using Λ1 than Λopt (difference of 5.0% with WET/WEPL=0.86). For 230(330) MeV protons, the MTF10% was found to increase by 40%(6%) respectively for a thick phantom (30cm) and by 25%(1%) for thinner phantom (25cm) when using the Λopt model compared to the Λ1 model. Conclusion: Based on these results, using CST with the Λopt factor reduces the RMS deviation and increases the spatial resolution when reconstructing proton trajectories.

60 APPLIED LIFE SCIENCES↗

Enhanced proton conductivity and dimensional stability of proton exchange membrane based on sulfonated poly(arylene ether sulfone) and graphene oxide

Highlights: • Proton conductivity of SPAES-GO-x membranes enhanced with increasing GO content. • Incorporating GO into SPAES matrix restrained SPAES-GO-x membranes swelling. • GO promoted the sulfonic acid groups of SPAES molecular chain aggregation (big ionic clusters) to enhance proton transport. - Abstract: A series composited membranes of sulfonated poly(arylene ether sulfone) and graphene oxide (SPAES-GO-x) have been exploited as proton exchange membrane. The properties of SPAES-GO-x membranes were evaluated including proton conductivity, water uptake, swelling ratio, oxide and thermal stability. Incorporating GO into SPAES matrix restrained the composite membranes swelling and enhanced their proton conductivity. The SPAES-GO-3% membrane showed a conductivity value of 0.183 S cm{sup −1} at 120 °C and relative humidity 100%. Compared with the pristine SPAES membrane, the swelling ratio of SPAES-GO-2% membrane was reduced by 55.7% at 90 °C. Small-Angle X-ray Scattering (SAXS) revealed GO promoted SPAES molecular chain movement to form bigger ionic clusters in favor of enhancing proton transport. X-Ray Diffraction and Field Emission Scanning Electron Microscope (XRD and FE-SEM) analysis further demonstrated GO was exfoliated and distributed throughout the SPAES matrix. These results indicated GO was an effective filler to trade off proton conductivity and swelling of composite membrane.

36 MATERIALS SCIENCE↗

Unveiling the two-proton halo character of 17 Ne: Exclusive measurement of quasi-free proton-knockout reactions

The proton drip-line nucleus 17 Ne is investigated experimentally in order to determine its two-proton halo character. A fully exclusive measurement of the 17 Ne (p, 2p) 16 F* 15 O+p quasi-free one-proton knockout reaction has been performed at GSI at around 500 MeV/nucleon beam energy. All particles resulting from the scattering process have been detected. The relevant reconstructed quantities are the angles of the two protons scattered in quasi-elastic kinematics, the decay of 16 F into 15 O (including γ decays from excited states) and a proton, as well as the 15 O+p relative-energy spectrum and the 16 F momentum distributions. The latter two quantities allow an independent and consistent determination of the fractions of l = 0 and l = 2 motion of the valence protons in 17 Ne. With a resulting relatively small l = 0 component of only around 35(3)%, it is concluded that 17 Ne exhibits a rather modest halo character only. The quantitative agreement of the two values deduced from the energy spectrum and the momentum distributions supports the theoretical treatment of the calculation of momentum distributions after quasi-free knockout reactions at high energies by taking into account distortions based on the Glauber theory. Moreover, the experimental data allow the separation of valence-proton knockout and knockout from the 15O core. The latter process contributes with 11.8(3.1) mb around 40% to the total proton-knockout cross section of 30.3(2.3) mb, which explains previously reported contradicting conclusions derived from inclusive cross sections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗