Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRODUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Access Patterns and Performance Behaviors of Multi-layer Supercomputer I/O Subsystems under Production Load

Scientific computing workloads at HPC facilities have been shifting from traditional numerical simulations to AI/ML applications for training and inference while processing and producing ever-increasing amounts of scientific data. To address the growing need for increased storage capacity, lower access latency, and higher bandwidth, emerging technologies such as non-volatile memory are integrated into supercomputer I/O subsystems. With these emerging trends, we need a better understanding of the multilayer supercomputer I/O systems and ways to use these subsystems efficiently. In this work, we study the I/O access patterns and performance characteristics of two representative supercomputer I/O subsystems. Through an extensive analysis of year-long I/O logs on each system, we report new observations in I/O reads and writes, unbalanced use of storage system layers, and new trends in user behaviors at the HPC I/O middleware stack.

Bez, JL↗

Data for An Orphan Gene BOOSTER Enhances Photosynthetic Efficiency and Plant Productivity

Seeds of Col-0 wild type, sig6 T-DNA mutants (CS877785, ABRC), PRL-1-OE, and sig6 T-DNA mutants transfected with PRL-1 (sig6::PRL-1) were planted in 1/2 MS media. Seedlings growth including chlorophyll development defects were investigated across the genotypes. Four-days-old-post-light exposure seedlings were harvested and performed RNAseq analysis with four biological replicates.

Biomass Analytics↗

Production of bio-diesel blend stocks via acid-catalyzed dehydration of ethanol oligomerization products

Ethanol is the most widely produced biofuel in the world. Gasoline demand is projected to decrease in the next 20 years largely due to an increase in electric vehicles. Diesel fuel demand is projected to continue to increase. Long-chain mono C10+ ethers have high cetane numbers and appropriate physical properties to be blended at high levels into petroleum diesel fuel. A techno-economic analysis shows that the ethers can be produced at prices similar to biodiesel. In our presentation we will show the catalytic chemistry involved in our ethanol to diesel approach, the engine and physical measurements of the produced diesel-range ethers, and a summary of the techno-economic analysis.

Canales, Emmanuel↗

Economic Extraction and Recovery of REEs and Production of Clean Value-Added Products from Low-Rank Coal Fly Ash

TechConnect World Innovation Conference & Expo, Washington, DC, June 13–15, 2022. The University of North Dakota (UND) Energy & Environmental Research Center (EERC) teamed with Pacific Northwest National Laboratory; the North Dakota Industrial Commission Lignite Research Program; and commercial partners Basin Electric Power Cooperative, Great River Energy, and Southern Company to execute a Cooperative Agreement funded by the U.S. Department of Energy’s National Energy Technology Laboratory (NETL) focused on identifying unique pathways and pretreatments to extract rare-earth elements (REEs) from low-rank coal (LRC) ash in a more economical and environmentally benign manner than current methods. By focusing on minimizing process steps and consumptive use of extraction solutions, a tunable, economically viable process for REE extraction from LRC ash was developed.

01 COAL, LIGNITE, AND PEAT↗

MassIVE MSV000085948 - Utilization of syringyl lignin-derived compounds and production of 2-pyrone-4,6-dicarboxylic acid by Pseudomonas putida KT2440: Lignin is an abundant aromatic polymer formed in plants by coupling reactions of p-coumaryl, coniferyl, and sinapyl alcohols. Pseudomonas putida KT2440 (P. putida KT2440), a robust soil bacterium, naturally catabolizes many aromatic compounds derived from lignin as carbon and energy sources and has been extensively engineered to valorize guaiacyl (G) and p-hydroxyphenyl (H) lignin-derived aromatic species to valuable chemicals. However, only a few studies report the capacity of Pseudomonads to grow on syringyl (S) lignin-derived compounds. In this work, we demonstrate that P. putida KT2440 catabolizes syringate in the presence of an auxiliary energy source. Overexpression of vanAB, encoding a native Rieske non-heme iron monooxygenase, enabled catabolism of syringate and syringaldehyde without an additional carbon and energy source. In vitro biochemical characterization of VanAB confirmed that this enzyme O-demethylates syringate to 3-O-methylgallate and, subsequently, 3-O-methylgallate to gallate, albeit 4- and 55-fold less efficiently than vanillate, respectively. Transcriptomics and proteomics experiments demonstrate that the galADBC transcripts and enzymes required for gallate catabolism are induced when vanAB is overexpressed during cultivation in syringate. Further, we show that that the endogenous protocatechuate-3,4-dioxygenase PcaHG ring-opens gallate to produce 2-pyrone-4,6-dicarboxylic acid (PDC), a promising bio-based chemical. Constitutive overexpression of vanAB and pcaHG along with galA deletion enabled PDC production from SA at a 70% (mol/mol) yield. Furthermore, leveraging the LigAB dioxygenase from Sphingobium sp. SYK-6 and VanAB O-demethylase from Pseudomonas sp. HR199 enabled simultaneous conversion of monomers with S-, G-, and H-type functionality to PDC at 82% (mol/mol) yield. Overall, this study elucidates a native pathway for catabolism of syringyl lignin-derived compounds in P. putida KT2440 and demonstrates the potential of this robust host for biological funneling of substrates derived from all three canonical monolignols.

Explore the source record for details and available documents.

Beckham, Gregg↗

\(J/\psi \) and \(\psi (2S)\) Production in Small Systems with PHENIX

The suppression of the ψ(2S) nuclear modification factor has been seen as a trademark signature of final-state effects in large collision systems for decades. In small systems, deviations of the nuclear modification from unity had been attributed to cold nuclear matter effects until the observation of strong differential suppression of the ψ(2S) state in p/d+A collisions, which suggests the presence of final-state effects. Here in this paper, we present results of J/ψ and ψ(2S) measurements in the dimuon decay channel for p + p, p+Al, and p+Au collision systems at $\sqrt{s_{NN}}$ = 200 GeV. Key results include the nuclear modification factors R pA as a function of centrality and rapidity. The measurements are compared with shadowing and transport model predictions, as well as complementary measurements at LHC energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engineered microorganisms for the production of intermediates and final products

The present disclosure relates to a non-naturally occurring microorganism that includes an endogenous genetic deletion that eliminates the expression of at least a pyruvate kinase, where the genetically modified prokaryotic microorganism is capable of producing 3-deoxy-D-arabino-heptulosonate-7-phosphate.

Johnson, Christopher W.↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗