Recommended test procedure for aircraft engine turbosupercharger power plants
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Propulsion subsystem surge analysis and testing was performed at NASA Goddard Space Flight Center (GSFC) in order to analytically and experimentally determine the potential for damaging dynamic pressure events in the Plankton Aerosol Cloud and ocean Ecosystem (PACE) propulsion subsystem. Surge pressures occur when propellant flow is initiated following the actuation of an isolation valve separating an upstream high pressure fluid from a downstream low pressure manifold. By design, the PACE propulsion subsystem mitigates surge pressures using an orifice, or a cavitating venturi, placed upstream of each thruster bank isolation latch valve. Venturi sizing is a balancing act due to the competing performance goals of staying within the margins of an acceptable pressure loss and maintaining surge pressures below the proof pressure rating of the subsystem components. Subsystem pressure loss is dependent upon the venturi throat diameter and is higher for smaller venturi sizes. A venturi with a smaller throat diameter incurs an increased pressure loss through the orifice resulting in a reduced thruster inlet pressure and diminished thruster performance. The PACE propulsion subsystem surge analysis and testing supports system optimization, i.e. pressure drop minimization, while still meeting the surge pressure requirements to maximize overall system performance. In this paper a new approach to surge pressure analytical gauging is discussed, as well as its accuracy when compared to traditional surge testing campaign.
Part 1 of this report focuses on results of the western Kentucky carbon storage test, and provides a basis for evaluating injection and storage of supercritical CO 2 in Cambro-Ordovician carbonate reservoirs throughout the U.S. Midcontinent. This test demonstrated that the Cambro- Ordovician Knox Group, including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite in stratigraphic succession from shallowest to deepest, had reservoir properties suitable for supercritical CO 2 storage in a deep saline reservoir hosted in carbonate rocks, and that strata with properties sufficient for long-term confinement of supercritical CO 2 were present in the deep subsurface. Injection testing with brine and CO 2 was completed in two phases. The first phase, a joint project by the Kentucky Geological Survey and the Western Kentucky Carbon Storage Foundation, drilled the Marvin Blan No. 1 carbon storage research well and tested the entire Knox Group section in the open borehole – including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite – at 1152–2255 m, below casing cemented at 1116 m. During Phase 1 injection testing, most of the 297 tonnes of supercritical CO 2 was displaced into porous and permeable sections of the lowermost Beekmantown below 1463 m and Gunter. The wellbore was then temporarily abandoned with a retrievable bridge plug in casing at 1105 m and two downhole pressure-temperature monitoring gauges below the bridge plug pending subsequent testing. Pressure and temperature data were recorded every minute for slightly more than a year, providing a unique record of subsurface reservoir conditions in the Knox. In contrast, Phase 2 testing, this study, tested a mechanically-isolated dolomitic-sandstone interval in the Gunter.
Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D2 molecules and the He atoms which will be produced by D-T fusion. To study He exhaust, Penning gauges were used to measure total neutral pressure assisted by spectroscopy to resolve the D and He partial pressures. In this contribution, initial results are shown from developing this technique into a miniaturized configuration for direct in-situ measurements in the divertor of fusion devices. The configuration is based off a gauge originally designed for the National Spherical Tokamak Experiment-Upgrade (NSTX-U). The goal of this new miniaturized design it to reduce the space required by the gauge on the device and use of the inherent magnetic field of the machine rather than permanent magnets inside the gauge, enabling it to be adapted into a system that can be extended directly into the divertor region. The feasibility test of the method for NSTX-U and the Wendelstein 7-X (W7-X) stellarator are surveyed. For W7-X, a commercial Penning Gauge has been installed on an outboard vacuum flange as a generic feasibility test in the neutral gas environment of a stellarator. At an integration time of 25s, helium lines can be seen down to 10^-5 mbar and H-alpha lines down to 10^-6 mbar. Successful measurement of the total as well as the fractional neutral pressures of He and H has been shown. A first prototype of the miniature Penning gauge has been tested in Madison and shows a near linear power law scaling between current and pressure: I = C*P^n with n = 1.0 - 1.2. Pressure measurements were achieved starting at 10^-3 mbar and down to 10^-6 mbar. A modular gauge is being assembled, which allows easy interchangeability of the anode to test new anode geometries, in order to improve optical access and increase spectroscopic sensitivity. This shall enable an increase of the time resolution of the spectroscopically assisted fractional neutral pressure measurements to up to 1kHz.
Ionization control system design for monitoring separately located ion gage pressures on vacuum chambers
NASA’s Psyche mission will launch in 2022 and begin a 3.6-year cruise to the metallic asteroid Psyche, the largest metal asteroid in the solar system. All primary propulsion will be done with the flight-proven SPT-140 electric propulsion subsystem. The Psyche mission will feature the first use of Hall thrusters for a NASA mission, and the first use of Hall thrusters beyond cis-lunar space, which has presented some unique challenges. In this paper we describe the Psyche propellant feed system architecture, expected propellant usage for the mission, propellant gauging requirements, and challenges associated with propellant gauging. Data from two recent Maxar electric orbit-raising missions with SPT-140 thrusters are reviewed and used to assess in-flight performance. We develop a pressure-volume-temperature gauging method that incorporates the propellant temperature distributions observed in the flight data, and use this method to provide an improved quantitative understanding of in-flight propellant consumption rates and their uncertainties. The results are in excellent agreement with the results of standard Maxar gauging methods and we determine a propellant usage uncertainty of ± 7.1% 3σ based on flight telemetry. Additionally, we demonstrate that the bookkeeping method of propellant gauging accurately predicts the tank pressure flight data. This work has led to design changes in the Psyche spacecraft avionics that will further improve propellant gauging uncertainties, which is particularly important for later phases of the mission. Finally, we statistically combine the predicted propellant mass uncertainties from the two gauging methods and demonstrate that the system will meet the mission requirements for propellant uncertainty. Together, all of this work provides confidence that the Psyche mission can be successfully completed within the existing propellant budget and propellant tank capacity.
Nonmagnetic quadrupole ionization gauge, discussing systems design and electron oscillations
Photoelectric and other effects of rubidium vapor on Bayard-Alpert ionization gauges at vacuum pressure due to condensable nature of vapor
Operating the JLab polarized electron source with high reliability and long lifetime requires vacuum near the XHV level, defined as pressure below 7.5×10 -13 Torr. This paper describes ongoing vacuum research at Jefferson Lab including characterization of outgassing rates for surface coatings and heat treatments, ultimate pressure measurements, investigation of pumping including an XHV cryopump, and characterization of ionization gauges in this pressure regime.
We have measured the luminescence shifts of the ruby’s R1- and R2-lines and the line of 5 D 0 → 7 F 0 from Sm 2+ :SrFCl corresponding to the melting pressure of mercury that is recommended by the AIRAPT task force as an International Practical Pressure Scale (IPPS). The linear coefficients of the pressure dependence of the R1-, R2-lines, and the luminescence line of Sm 2+ :SrFCl are determined to be 0.3722 ± 0.002, 0.3796 ± 0.002, and 1.123 ± 0.002 nm/GPa, respectively. The results not only put tight constraints on the initial slopes of ruby and Sm 2+ :SrFCl gauges, but also link the luminescence-based pressure gauges to the more fundamental primary piston gauges.
The phrase, "common-layered architecture for semiconductor silicon carbide" ("CLASSiC") denotes a method of batch fabrication of microelectromechanical and semiconductor devices from bulk silicon carbide. CLASSiC is the latest in a series of related methods developed in recent years in continuing efforts to standardize SiC-fabrication processes. CLASSiC encompasses both institutional and technological innovations that can be exploited separately or in combination to make the manufacture of SiC devices more economical. Examples of such devices are piezoresistive pressure sensors, strain gauges, vibration sensors, and turbulence-intensity sensors for use in harsh environments (e.g., high-temperature, high-pressure, corrosive atmospheres). The institutional innovation is to manufacture devices for different customers (individuals, companies, and/or other entities) simultaneously in the same batch. This innovation is based on utilization of the capability for fabrication, on the same substrate, of multiple SiC devices having different functionalities (see figure). Multiple customers can purchase shares of the area on the same substrate, each customer s share being apportioned according to the customer s production-volume requirement. This makes it possible for multiple customers to share costs in a common foundry, so that the capital equipment cost per customer in the inherently low-volume SiC-product market can be reduced significantly. One of the technological innovations is a five-mask process that is based on an established set of process design rules. The rules provide for standardization of the fabrication process, yet are flexible enough to enable multiple customers to lay out masks for their portions of the SiC substrate to provide for simultaneous batch fabrication of their various devices. In a related prior method, denoted multi-user fabrication in silicon carbide (MUSiC), the fabrication process is based largely on surface micromachining of poly SiC. However, in MUSiC one cannot exploit the superior sensing, thermomechanical, and electrical properties of single-crystal 6H-SiC or 4H-SiC. As a complement to MUSiC, the CLASSiC five-mask process can be utilized to fabricate multiple devices in bulk single-crystal SiC of any polytype. The five-mask process makes fabrication less complex because it eliminates the need for large-area deposition and removal of sacrificial material. Other innovations in CLASSiC pertain to selective etching of indium tin oxide and aluminum in connection with multilayer metallization. One major characteristic of bulk micromachined microelectromechanical devices is the presence of three-dimensional (3D) structures. Any 3D recesses that already exist at a given step in a fabrication process usually make it difficult to apply a planar coat of photoresist for metallization and other subsequent process steps. To overcome this difficulty, the CLASSiC process includes a reversal of part of the conventional flow: Metallization is performed before the recesses are etched.
Modified McLeod gauge which automatically records pressures
Cerium has a complex phase diagram that is explained by the presence of structural phase transitions. Experiments to measure the sound velocities in cerium by two methods were carried out to determine the onset of cerium melting on the Hugoniot. In the pressure range 4-37 GPa, the sound velocity in cerium samples was measured by the counter release method using manganin-based piezoresistive gauges. In the pressure range 35-140 GPa, the sound velocity in cerium was measured by the overtaking release method using carbogal and tetrachloromethane indicator liquids. The samples were loaded with plane shock wave generators using powerful explosive charges. The onset of cerium melting on the Hugoniot at a pressure of about 13 GPa has been ascertained from the measured elastic longitudinal and bulk sound velocities.
A new flow-control system (FCS-705) has been developed at Korea Research Institute of Standards and Science. The system is intended for calibration of vacuum gauges in the pressure range of 1 Pa-133 Pa by comparison method. This paper describes some basic characteristics of the system including; (1) the design and construction of the system, (2) the generation of stable pressures in the chamber, (3) achieving high upstream pressure limit by installing a short duct in the by-pass pumping line, and (4) investigation of the gas flow regimes within the short duct.
Volume-ratio pressure measurement calibration system for vacuum gauges
Abstract Peterie et al. question one observation in our paper: associating pressure increases to injection volumes at distances of up to 25 km from an injection well. In this reply, we show that the comment misunderstands our analysis and the evidence that led to this conclusion. We also show that gauge‐depth‐corrected pressures, used by the authors to produce statewide pressure maps, are discrepant with the static fluid level data, provided in our original compilation and analysis. The discrepancies are a result of the pressure correction method employed, which naïvely substitutes formation pressure for bottomhole pressure to calculate wellbore fluid density. Their linearly interpolated pressure maps, based on sparse data, contain interpolation and extrapolation artifacts that contradict injection trends in the state, the Theis solution, and the superposition principle. We reiterate that pressure and static fluid level increases in Class I wells existed prior to 2013, most notably in central Kansas, where recent earthquakes are cited in the comment as evidence of a pressure plume emanating from the Kansas‐Oklahoma border, 90 km away. We show that the space‐time pattern of seismicity in this area is inconsistent with a northward propagating pressure plume and, instead, seismicity appears to be centered on and near a cluster of high‐rate injection wells, two of which are among the highest rate wells in the state. These observations, along with recent M4 + earthquakes during continued decreases in wastewater injection in southern Kansas and northern Oklahoma, question the usefulness of the comment for understanding and managing societally significant earthquakes.
Extremely lightweight, compact, noninvasive, rugged, relatively inexpensive strain-gauge transducers have been developed for use in measuring pressures of fluids in tubes. These gauges were originally intended for measuring pressures of spacecraft-propulsion fluids, but they are also attractive for use in numerous terrestrial applications especially those involving fluids that are extremely chemically reactive, fluids that must be isolated for hygienic purposes, fluids that must be allowed to flow without obstruction, and fluid-containing tubes exposed to severe environments. A basic pressure transducer of this type comprises one or more pair(s) of thin-film strain gauges integral with a tube that contains the fluid of interest. Following established strain-gauge practice, the gauges in each pair are connected into opposite arms of a Wheatstone bridge (see figure). Typically, each pressure transducer includes one pair (the active pair) of strain gauges for measuring the hoop stress proportional to the pressure of the fluid in the tube and another pair (the dummy pair) of strain gauges that are nominally unstrained: The dummy gauges are mounted on a substrate that is made of the same material as that of the tube. The substrate is welded to the tube at only one spot so that stresses and strains are not coupled from the tube into the substrate. The dummy strain gauges measure neutral strains (basically, strains associated with thermal expansion), so that the neutral-strain contribution can be subtracted out of the final gauge reading.
A Hamiltonian/Lagrangian theory to describe guiding center orbit drift motion that is canonical in Boozer magnetic coordinates is developed to include full electrostatic and electromagnetic perturbed fields in axisymmetric tokamak geometry. Furthermore, the radial component of the equilibrium magnetic field in the covariant representation is retained and the background equilibrium state extends to anisotropic plasma pressure conditions. A gauge transformation on the perturbed vector potential is imposed to guarantee canonical structure in the Boozer frame. Perturbed field nonlinear wave-wave interactions affect only the evolution of the guiding center particle parallel gyroradius. The evolution of the particle coordinate positions retains only linear wave-particle interactions. For particle motion in magnetohydrodynamic (MHD) instability structures, the electrostatic potential is linked mainly to the binormal component of the perturbed displacement vector when finite {delta}A{sub perpendicular} components are included.