Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

36 MATERIALS SCIENCE↗

Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

42 ENGINEERING↗

Techno-Economic Analysis of Solid Oxide Fuel Cell-Gas Turbine Hybrid Systems for Stationary Power Applications Using Renewable Hydrogen

Solid oxide fuel cell (SOFC)–gas turbine (GT) hybrid systems can produce power at high electrical efficiencies while emitting virtually zero criteria pollutants (e.g., ozone, carbon monoxide, oxides of nitrogen and sulfur, and particulate matters). This study presents new insights into renewable hydrogen (RH 2 )-powered SOFC–GT hybrid systems with respect to their system configuration and techno-economic analysis motivated by the need for clean on-demand power. First, three system configurations are thermodynamically assessed: (I) a reference case with no SOFC off-gas recirculation, (II) a case with cathode off-gas recirculation, and (III) a case with anode off-gas recirculation. While these configurations have been studied in isolation, here we provide a detailed performance comparison. Moreover, a techno-economic analysis is conducted to study the economic competitiveness of RH 2 -fueled hybrid systems and the economies of scale by offering a comparison to natural gas (NG)-fueled systems. Results show that the case with anode off-gas recirculation, with 68.50%-lower heating value (LHV) at a 10 MW scale, has the highest efficiency among the studied scenarios. When moving from 10 MW to 50 MW, the efficiency increases to 70.22%-LHV. These high efficiency values make SOFC–GT hybrid systems highly attractive in the context of a circular economy as they outcompete most other power generation technologies. The cost-of-electricity (COE) is reduced by about 10% when moving from 10 MW to 50 MW, from USD 1976/kW to USD 1668/kW, respectively. Renewable H 2 is expected to be economically competitive with NG by 2030, when the U.S. Department of Energy’s target of USD 1/kg RH 2 is reached.

25 ENERGY STORAGE↗

Analytical Modeling of Spacecraft Power Systems

During the 25 years of space flight with unmanned Earth orbiting satellites, there has been an evolution of power systems in three general areas. The size of power system in terms of power demand at the bus has increased frorm a few watts in the early 1960s to a few hundred watts during the 1970s. Today, the bus power requirements are typically in the .5 to 1 kw range with some mission requirements exceeding the 1 kw size. Power grounding and user isolation are major design considerations when high fidelity power is required by a user.

Ford, F. E.↗

Advanced-technology space station study: Summary of systems and pacing technologies

The principal system features defined for the Advanced Technology Space Station are summarized and the 21 pacing technologies identified during the course of the study are described. The descriptions of system configurations were extracted from four previous study reports. The technological areas focus on those systems particular to all large spacecraft which generate artificial gravity by rotation. The summary includes a listing of the functions, crew requirements and electrical power demand that led to the studied configuration. The pacing technologies include the benefits of advanced materials, in-orbit assembly requirements, stationkeeping, evaluations of electrical power generation alternates, and life support systems. The descriptions of systems show the potential for synergies and identifies the beneficial interactions that can result from technological advances.

Butterfield, A. J.↗

Reactor safety for the Space Exploration Initiative

A task force was created by the National Aeronautics and Space Administration to conduct a 90-day study to support efforts to determine requirements to meet the goals of the Space Exploration Initiative. The task force identified the need for a nuclear reactor to provide the electrical power required as the outpost power demands on the moon and Mars evolve into hundreds of kilowatts. A preliminary hazards analysis has been performed to examine safety aspects of nuclear reactor power systems for representative missions to the moon and Mars. Mission profiles were defined for reference lunar and Martian flights. Potential alternatives to each mission phase were also defined. Accident scenarios were qualitatively defined for the mission phases. The safety issues decay heat removal, reactor control, disposal, criticality, end-of-mission shutdown, radiation exposure, the Martian environment, high speed impact on the surfaces of the moon or Mars, and return flyby trajectories were identified.

Dix, Terry E.↗

Heterogeneous climate change impacts on electricity demand in world cities circa mid-century

Rising ambient temperatures due to climate change will increase urban populations’ exposures to extreme heat. During hot hours, a key protective adaptation is increased air conditioning and associated consumption of electricity for cooling. But during cold hours, milder temperatures have the offsetting effect of reducing consumption of electricity and other fuels for heating. We elucidate the net consequences of these opposing effects in 36 cities in different world regions. We couple reduced-form statistical models of cities’ hourly responses of electric load to temperature with temporally downscaled projections of temperatures simulated by 21 global climate models (GCMs), projecting the effects of warming on the demand for electricity circa 2050. Cities' responses, temperature exposures and impacts are heterogeneous, with changes in total annual consumption ranging from –2.7 to 5.7%, and peak power demand increasing by as much as 9.5% at the multi-GCM median. The largest increases are concentrated in more economically developed mid-latitude cities, with less developed urban areas in the tropics exhibiting relatively small changes. The results highlight the important role of the structure of electricity demand: large temperature increases in tropical cities are offset by their inelastic responses, which can be attributed to lower air-conditioning penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Risk Reduction via Geothermal/Solar Hybrid Power Plants. Final Report

There are numerous technical merits associated with a renewable geothermal-solar hybrid plant concept. The performance of air-cooled binary plants is lowest when ambient temperatures are high due to the decrease in air-cooled binary plant performance that occurs when the working fluid condensing temperature, and consequently the turbine exhaust pressure, increases. Electrical power demand is generally at peak levels during periods of elevated ambient temperature and it is therefore especially important to utilities to be able to provide electrical power during these periods. The time periods in which air-cooled binary geothermal power plant performance is lowest generally correspond to periods of high solar insolation. Use of solar heat to increase air-cooled geothermal power plant performance during these periods can improve the correlation between power plant output and utility load curves. While solar energy is a renewable energy source with long term performance that can be accurately characterized, on shorter time scales of hours or days it can be highly intermittent. Concentrating solar power (CSP), aka solar-thermal, plants often incorporate thermal energy storage to ensure continued operation during cloud events or after sunset. Hybridization with a geothermal power plant can eliminate the need for thermal storage due to the constant availability of geothermal heat. In addition to the elimination of the requirement for solar thermal storage, the ability of a geothermal/solar-thermal hybrid plant to share a common power block can reduce capital costs relative to separate, stand-alone geothermal and solar-thermal power plant installations. The common occurrence of long-term geothermal resource productivity decline provides additional motivation to consider the use of hybrid power plants in geothermal power production. Geothermal resource productivity decline is a source of significant risk in geothermal power generation. Many, if not all, geothermal resources are subject to decreasing productivity manifested in the form of decreasing production fluid temperature, flow rate, or both during the life span of the associated power generation project. The impacts of geothermal production fluid temperature decline on power plant performance can be significant; a reduction in heat input to a power plant not only decreases the thermal energy available for conversion to electrical power, but also adversely impacts the power plant efficiency. The impact of resource productivity decline on power generation project economics can be equally detrimental. The reduction in power generation is directly correlated to a reduction in revenues from power sales. Further, projects with Power Purchase Agreement (PPA) contracts in place may be subject to significant economic penalties if power generation falls below a specified default level. While the magnitude of PPA penalties varies on a case-by-case basis, it is not unrealistic for these penalties to be on the order of the value of the deficit power sales such that the utility may purchase the power elsewhere. This report evaluates the use of geothermal/solar-thermal hybrid plant technology for mitigation of resource productivity decline, which has not been a primary topic of investigation in previous analyses in the open literature.

14 SOLAR ENERGY↗

Performance Testing of a Liquid Metal Pump for In-Space Power Systems

Fission surface power (FSP) systems could be used to provide power on the surface of the moon, Mars, or other planets and moons of our solar system. Fission power systems could provide excellent performance at any location, including those near the poles or other permanently shaded regions, and offer the capability to provide on demand power at any time, even at large distances from the sun. Fission-based systems also offer the potential for outposts, crew and science instruments to operate in a power-rich environment. NASA has been exploring technologies with the goal of reducing the cost and technical risk of employing FSP systems. A reference 40 kWe option has been devised that is cost-competitive with alternatives while providing more power for less mass anywhere on the lunar surface. The reference FSP system is also readily extensible for use on Mars, where it would be capable of operating through global dust storms and providing year-round power at any Martian latitude. Detailed development of the FSP concept and the reference mission are documented in various other reports. The development discussed in this paper prepares the way for testing of the Technology Demonstration Unit (TDU), which is a 10 kWe end-to-end test of FSP technologies intended to raise the entire FSP system to technology readiness level (TRL) 6. The Early Flight Fission Test Facility (EFF-TF) was established by NASA s Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a nonnuclear test methodology. This includes fabrication and testing at both the module/component level and at near prototypic reactor components and configurations allowing for realistic thermal-hydraulic evaluations of systems. The liquid-metal pump associated with the FSP system must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National Laboratory (INL) was tasked with the modeling, design, and fabrication of an ALIP suitable for the FSP reference mission. A prototypic ALIP was fabricated under the direction of INL and shipped to MSFC for inclusion in the Technology Demonstration Unit (TDU), a quarter-scale end-to-end reactor simulator system that is scheduled for testing at NASA-GRC. Before inclusion in the TDU, the ALIP was tested in the ALIP test circuit (ATC), which is a rig developed and operated at MSFC for the specific purpose of providing accurate quantification of liquid metal pump performance. Data showing the pump performance curves (pressure, flowrate, and pump efficiency) are presented for various operating power levels, demonstrating the full performance envelope of the pump.

Polzin, Kurt↗

A reinforcement learning approach to long-horizon operations, health, and maintenance supervisory control of advanced energy systems

In this work, we develop a Reinforcement Learning (RL) approach to the supervisory control problem for advanced energy systems, such as novel nuclear reactors and other demand-driven, mission-critical, and component-health-sensitive energy plants. The inclusive problem landscape considered captures the stochastic confluence of plant performance, component health evolution, power demand from the grid, diverse maintenance actions, and operator-defined goals and constraints, all considered over meaningfully long-enough reasoning horizons. Key aspects of the proposed approach are a receding horizon control-inspired technique dictating time- or event-triggered supervisory policy (re-)constructions, as well as additional capability-enabling contributions such as timescale compression, to handle long reasoning horizons and uncertainty in parts of the problem, and practical yet demonstrably-effective handling of hybrid action spaces with continuous and discrete decision variables. The resulting algorithm consists of a simulation-based RL agent constructing stochastic supervisory control policies over nontrivial action spaces and for long horizons, applying the learned policy to the system for a much shorter interval, and perpetually repeating, to construct the next long-horizon policy. That next policy will only be applied, again, for a short interval, yet originally far-in-time events move progressively closer, their associated uncertainty decreases, and new events and aspects enter the reasoning horizon. The proposed methodology bridges fundamental receding horizon concepts with the unequivocally stronger and more scalable reasoning of contemporary RL. Numerical examples using Soft Actor–Critic Deep RL illustrate the operation and efficacy of the proposed technique for a power plant tasked with health-aware load following missions in a dynamic electricity market landscape.

97 MATHEMATICS AND COMPUTING↗

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel Integrated Magnetic Structure Based DC/DC Converter for Hybrid Battery/Ultracapacitor Energy Storage Systems

This manuscript focuses on a novel actively controlled hybrid magnetic battery/ultracapacitor based energy storage system (ESS) for vehicular propulsion systems. A stand-alone battery system might not be sufficient to satisfy peak power demand and transient load variations in hybrid and plug-in hybrid electric vehicles (HEV, PHEV). Active battery/ultracapacitor hybrid ESS provides a better solution in terms of efficient power management and control flexibility. Moreover, the voltage of the battery pack can be selected to be different than that of the ultracapacitor, which will result in flexibility of design as well as cost and size reduction of the battery pack. In addition, the ultracapacitor bank can supply or recapture a large burst of power and it can be used with high C-rates. Hence, the battery is not subjected to supply peak and sharp power variations, and the stress on the battery will be reduced and the battery lifetime would be increased. Utilizing ultracapacitor results in effective capturing of the braking energy, especially in sudden braking conditions.

25 ENERGY STORAGE↗

Eliminating the Derate of Carbon Capture Retrofits

Retrofitting existing PC plants with amine-based CO 2 capture technology is thermally- and power-intensive. This study examines the benefit of installing a natural gas simple cycle to provide the auxiliaries required to operate the amine system such that the original power demand can still be met.

20 FOSSIL-FUELED POWER PLANTS↗

A Battery Health Monitoring Framework for Planetary Rovers

Batteries have seen an increased use in electric ground and air vehicles for commercial, military, and space applications as the primary energy source. An important aspect of using batteries in such contexts is battery health monitoring. Batteries must be carefully monitored such that the battery health can be determined, and end of discharge and end of usable life events may be accurately predicted. For planetary rovers, battery health estimation and prediction is critical to mission planning and decision-making. We develop a model-based approach utilizing computaitonally efficient and accurate electrochemistry models of batteries. An unscented Kalman filter yields state estimates, which are then used to predict the future behavior of the batteries and, specifically, end of discharge. The prediction algorithm accounts for possible future power demands on the rover batteries in order to provide meaningful results and an accurate representation of prediction uncertainty. The framework is demonstrated on a set of lithium-ion batteries powering a rover at NASA.

prediction↗

Energy storage: Redox flow batteries go organic

Access to sustainable and affordable energy is the foundation for the economic growth of our current society and its future prosperity. Energy harvested from renewable resources, such as solar and wind, although currently at a small fraction, is on a steady trajectory of increasing installation accompanied with falling cost. Driven also by the need to reduce the carbon footprint from electricity generation, they could provide a clean and sustainable energy future. The caveat, however, is the intermittent and fluctuating nature of the renewables, which threatens the stability of the grid when its share surpasses 20% of the overall energy capacity. 1 Besides the on-demand power generation, electrical energy storage is another potentially cost-effective way to provide massive energy storage for not only renewable energy integration, but to balance the mismatch between supply and demand, and the improvement of grid reliability and efficiency also.

Wang, Wei↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PQScal (Power Quality Score Calculation for Distribution Systems with DER Integration)

Power Quality is of great importance to evaluate the “health” of a distribution system, especially when the distributed energy resource (DER) penetration becomes more significant. The individual components that make up power quality, such as voltage magnitude and unbalance, can be measured in simulations or in the field, however, a comprehensive method to incorporate all of these values into a single score doesn't exist. As a result, we propose a methodology to quantify the power quality health using the single number value, named as Power Quality Score (PQS). The PQS is dependent on six metrics that are developed based on both components that directly impact power quality and those are often reference in the context of power quality. These six metrics are named as System Average Voltage Magnitude Violation Index (SAVMVI), System Average Voltage Fluctuation Index (SAVFI), System Average Voltage Unbalance Index (SAVUI), System Control Device Operation Index (SCDOI), System Reactive Power Demand Index (SRPDI) and System Energy Loss Index (SELI). This software tool, PQScal, is developed based on this novel PQS methodology. Besides of traditional distribution systems, PQScal can also measure the power quality for distribution systems with various DER penetrations. PQScal has been tested on two utility distribution feeders with distinct model characteristics and its effectiveness has been proved. In sum, PQScal can help utilities or other parties to measure the power quality of distribution systems with DER integration easily and effectively.

Source record↗

Human life support during interplanetary travel and domicile. III - Mars expedition system trade study

Several alternative configurations of life-support systems (LSSs) for a Mars missions are compared analytically on a quantitative basis in terms of weight, volume, and power. A baseline technology set is utilized for the illustrations of systems including totally open loop, carbon dioxide removal only, partially closed loop, and totally closed loop. The analytical model takes advantage of a modular, top-down hierarchical breakdown of LSS subsystems into functional elements that represent individual processing technologies. The open-loop systems are not competitive in terms of weight for both long-duration orbiters and short-duration lander vehicles, and power demands are lowest with the open loop and highest with the closed loop. The closed-loop system can reduce vehicle weight by over 70,000 lbs and thereby overcome the power penalty of 1600 W; the closed-loop variety is championed as the preferred system for a Mars expedition.

Seshan, P. K.↗