Capability in Theory, Modeling, and Validation for a Range of Innovative Fusion Concepts using High-Fidelity Moment-Kinetic Models

A computational modeling capability is created and available to the fusion community to understand and design lower-cost and innovative fusion concepts. The approach uses high- fidelity kinetic, moment-kinetic, and moment models and includes sophisticated plasma- boundary interactions. A majority of fusion-relevant simulations are performed with magnetohydrodynamic models and hybrid particle-in-cell codes, with limited-fidelity electron and kinetic physics. However, in fusion configurations like Z-pinches, field-reversed- configurations, plasma jet magneto-inertial fusion, spinning mirrors, and others, kinetic effects (both electron and ions) are critical to understand the physics and design scaling into the highly kinetic regime of a burning fusion plasma. Furthermore, as present fusion machines move towards a burning plasma regime, liquid-metal blankets are needed to handle first-wall heat- flux, reduce erosion, and eventually for energy conversion and fuel breeding. The work performed under this ARPA-E BETHE Capability Team advances the state-of-the-art in modeling and understanding plasma dynamics in fusion devices and its coupling with liquid-metal dynamics. These are critical areas of research for fusion energy to become realizable. To address these complex problems, we have leveraged and extended computational capabilities through the code, Gkeyll (developed jointly with Princeton Plasma Physics Laboratory and academic partners), for kinetic and moment modeling of fusion plasmas. The Concept Teams supported by this Capability Team include the Wisconsin High-field Axisymmetric Mirror (WHAM), Centrifugal Mirror Experiment (CFME), Plasma-Jet Magneto- Inertial Fusion (PJMIF), and solid and liquid wall plasma-material interaction studies relevant to a number of fusion concepts including Zap Energy’s Z-pinch. This software is open-source and available to the fusion community as a high-fidelity tool for the design of lower-cost fusion experiments. 3D gyrokinetic simulations of WHAM are now possible for long enough time scales to understand the evolution of interchange instabilities. 3D multi-fluid simulations of CMFE at higher Mach numbers are now possible for detailed design iterations with the goal of stability. The state-of-the-art in understanding shock formation and shock mitigation regimes in merging liners for PJMIF have been furthered by our kinetic simulations. Our novel models and frameworks studying plasma-material interaction by incorporating wall emission for various solid wall materials of relevance to pulsed and steady fusion concepts have advanced the state-of-the-art in our understanding of particle fluxes, heat fluxes, and other quantities at cathodes and anodes. The results from this work may explain discrepancies between experimental and theoretical predictions of achieved current densities in pulsed concepts such as Z-pinches. Another significant contribution of this Capability Team is the development and deployment of a novel experimental platform, LEX (Liquid Electrode eXperiment), at Virginia Tech to understand liquid metal free-surface response to electromagnetic pulses. The novel experiments along with model validation quantified the effect of different materials and sizes of liquid metal droplets on the radiative power balance of fusion plasmas for pulsed concepts. Furthermore, these experiments provided mitigation strategies for violent liquid metal response for high current pulses as would be expected in fusion regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the field‐aligned electric field in the polar cap

Abstract The Johns Hopkins University Applied Physics Laboratory open‐field line particle precipitation model predicts downward field‐aligned electric field to maintain charge quasi‐neutrality. Previous studies confirmed the existence of such electric fields. However, the present study shows that upward field‐aligned electric field can be found within upward field‐aligned current (FAC) region. In the upward FAC region, upward electric field that accelerates electron downward is seen with the occurrence rates of 82%–96%. In contrast, the occurrence rates in the downward FAC regions are 3%–11%. Polar rain electrons located in the upward FAC region adjacent to closed field lines often show a ramping up of energy with increasing latitude before reaching a plateau. This plateau may be attributed to the magnetosheath electrons that progressively have higher antisunward velocity and lower density with increasing distance from the subsolar point before they asymptotically reach the solar wind values.

Wing, Simon↗

New Schemes of Digital Speckle Photography

This paper presents a review and an analysis of the development of speckle photography from the first experiments performed at the National Physical Laboratory of Great Britain up to the present time. The possibility of diagnosing turbulent and three-dimensional flows by the speckle photography methods has been shown. The single-exposure scheme of speckle photography has been analyzed and the possibility of using multiaspect speckle photography in reconstructive tomography of complex three-dimensional flows has been shown. Methods based on speckle technologies such as Talbot interferometry, PIV and BOS techniques have been analyzed. Particular consideration is given to the application of new measuring technologies in diagnosing turbulent flows and reconstructive tomography of three-dimensional flows.

42 ENGINEERING↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PET examination in intracranial tumor diagnosis of a cat

This paper shows the significance of the Positron Emission Tomography (PET) in the veterinary medication through a case study of a cat brain tumor. A castrated male cat with bilateral mydriasis and blindness arrived at the veterinary clinic. After physical, laboratory and neurological investigations other sickness was ruled out and the inkling of the intracranial lesion had come to light. Brain tumor seemed the most likely to cause the illness because other symptoms appeared (for example: anorexia, depression) and they progrediated fast. PET examination, using {sup 18}F-FDG isotope, was performed to confirm the possible causes of the cat's symptoms.

60 APPLIED LIFE SCIENCES↗

Multi-harmonic RF test stand for RF breakdown studies

A multi-harmonic RF test stand is under construction at Yale Beam Physics Laboratory. It includes a frequency multiplier which can generate high power harmonics efficiently that are phase locked to the fundamental drive frequency. In a bi-modal asymmetric cavity powered by this RF source, the cavity may experience reduced exposure time to peak fields and sweeping of peak fields across their surfaces, and strong asymmetry between surfaces that may experience cathode-and anode-like fields; these phenomena are to be assessed for their influence on RF breakdown probabilities.

43 PARTICLE ACCELERATORS↗

Development of a new radiometer for the thermodynamic measurement of high temperature fixed points

The National Physical Laboratory (NPL) has developed a new radiometer to measure the thermodynamic melting point temperatures of high temperature fixed points with ultra-low uncertainties. In comparison with the NPL's Absolute Radiation Thermometer (ART), the 'THermodynamic Optical Radiometer' (THOR) is more portable and compact, with a much lower size-of-source effect and improved performance in other parameters such as temperature sensitivity. It has been designed for calibration as a whole instrument via the radiance method, removing the need to calibrate the individual subcomponents, as required by ART, and thereby reducing uncertainties. In addition, the calibration approach has been improved through a new integrating sphere that has been designed to have greater uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly and commissioning of a new SRF cryomodule for the ATLAS intensity upgrade

The Argonne National Laboratory Physics Division is in the final stages of a major upgrade to the Argonne Tandem Linear Accelerator System national user facility, referred to as the intensity upgrade. The intensity upgrade project will substantially increase beam currents for experimenters working with the existing ATLAS stable and in-flight rare isotope beams and for the neutron-rich beams from the Californium Rare Isotope Breeder Upgrade. This project includes the replacement of three existing cryomodules, containing 18 superconducting accelerator cavities and 9 superconducting solenoids, with a single cryomodule with seven SC 72.75 MHz accelerator cavities optimized for ion velocities of 7.7% the speed of light and 4 SC solenoids all operating at 4.5 K. This presentation will report: how we minimized the heat load into the 4 K and 80 K coolant streams feeding the cryomodule, a comparison of the calculated and measured static heat loads at 80 K and the mechanical design of the vacuum vessel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrical detection of liquid lithium leaks from pipe joints

A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

42 ENGINEERING↗

Characterization of the KM3NeT photomultipliers in the Hellenic Open University

The KM3NeT neutrino research infrastructure will be a deep sea multidisciplinary observatory in the Mediterranean Sea hosting a neutrino telescope. The Physics Laboratory of the Hellenic Open University is involved in the characterization of the KM3NeT neutrino detector. The present work describes measurement techniques for the functional characteristics of the candidate KM3NeT photomultipliers. These characteristics include dark current, transit time spread, gain slope and single photoelectron characteristics, as well as delayed and after pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary measurements of the edge magnetic field pitch from 2-D Doppler backscattering in MAST and NSTX-U (invited)

The Synthetic Aperture Microwave Imaging (SAMI) system is a novel diagnostic consisting of an array of 8 independently phased antennas. At any one time, SAMI operates at one of the 16 frequencies in the range 10-34.5 GHz. The imaging beam is steered in software post-shot to create a picture of the entire emission surface. In SAMI’s active probing mode of operation, the plasma edge is illuminated with a monochromatic source and SAMI reconstructs an image of the Doppler back-scattered (DBS) signal. By assuming that density fluctuations are extended along magnetic field lines, and knowing that the strongest back-scattered signals are directed perpendicular to the density fluctuations, SAMI’s 2-D DBS imaging capability can be used to measure the pitch of the edge magnetic field. In this paper, we present preliminary pitch angle measurements obtained by SAMI on the Mega Amp Spherical Tokamak (MAST) at Culham Centre for Fusion Energy and on the National Spherical Torus Experiment Upgrade at Princeton Plasma Physics Laboratory. Lastly, the results demonstrate encouraging agreement between SAMI and other independent measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗

Application of an energy-dependent instrument response function to analysis of nTOF data from cryogenic DT experiments

Neutron time-of-flight (nTOF) detectors are used to diagnose the conditions present in inertial confinement fusion (ICF) experiments and basic laboratory physics experiments performed on an ICF platform. The instrument response function (IRF) of these detectors is constructed by convolution of two components: an x-ray IRF and a neutron interaction response. The shape of the neutron interaction response varies with incident neutron energy, changing the shape of the total IRF. Analyses of nTOF data that span a broad range of energies must account for this energy-dependence in order to accurately infer plasma parameters and nuclear properties in ICF experiments. This work briefly reviews a matrix multiplication approach to convolution which allows for an energy-dependent change in the shape of the IRF. This method is applied to synthetic data resembling symmetric cryogenic DT implosions to examine the effect of the energy-dependent IRF on the inferred areal density. Here, results of forward fits that infer ion temperatures and areal densities from nTOF data collected during cryogenic DT experiments on OMEGA are also discussed.

47 OTHER INSTRUMENTATION↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Ion temperature measurements from tomographic reconstruction of Doppler spectra in the presence of multi-component flow in two dimensions

A new ion Doppler diagnostic has been constructed to measure ion temperature profiles in the presence of multi-component flow during magnetic reconnection experiments. The inversion technique and diagnostic setup are applicable to axisymmetric plasmas with two-component flow across the measurement cross section, which occurs during magnetic reconnection. The particular design discussed here is optimized for operation on the Magnetic Reconnection eXperiment (MRX) at Princeton Plasma Physics Laboratory. To prove the viability of this diagnostic for MRX and the future Facility for Laboratory Reconnection Experiments, measurements have been taken and ion temperature and perpendicular flow profiles have been obtained. The radial velocity on MRX does not contribute to the Doppler shift of the measured spectra but does contribute to the broadening of the spectra, while toroidal flow contributes to both. It is shown that neglecting the radial velocity for vR = 20 km/s leads to an error in the ion temperature inversion of 20%. Results from MRX discharges are shown, and the impact of radial velocity on ion temperature inversions is discussed.

Goodman, A. (ORCID:0000000336396572)↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

Movement and collision of Lagrangian particles in hydro-turbine intakes: a case study

Studies of the stress/survival of migratory fish during downstream passage through operating hydro-turbines are normally conducted to determine the fish-friendliness of units. One field approach consisting of recording extreme hydraulics with autonomous sensors is largely sensitive to the conditions of sensor release and the initial trajectories at the turbine intake. This study applies a modelling strategy based on flow simulations using computational fluid dynamics and Lagrangian particle tracking to represent the travel of live fish and autonomous sensor devices through hydro-turbine intakes. For the flow field calculation, the simulations were conducted with both a time-averaging turbulence model and an eddy-resolving technique. For the particle tracking calculation, different modelling assumptions for turbulence forcing, mass formulation, buoyancy, and release condition were tested. The modelling assumptions are evaluated with respect to data sets collected using a laboratory physical model and an autonomous sensor device deployed at Ice Harbor Dam (Snake River, State of Washington, U.S.A.) at the same discharge and release point as in the present computer simulations. We found an acceptable agreement between the simulated results and observed data and discuss relevant features of Lagrangian particle movement that are critical in turbine design and in the experimental design of field studies.