Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A perspective on the electro-thermal co-design of ultra-wide bandgap lateral devices

Fundamental research and development of ultra-wide bandgap (UWBG) semiconductor devices are under way to realize next-generation power conversion and wireless communication systems. Devices based on aluminum gallium nitride (AlxGa1-xN, x is the Al composition), ..beta..-phase gallium oxide (..beta..-Ga2O3), and diamond give promise to the development of power switching devices and radio frequency power amplifiers with higher performance and efficiency than commercial wide bandgap semiconductor devices based on gallium nitride (GaN) and silicon carbide (SiC). However, one of the most critical challenges for the successful deployment of UWBG device technologies is to overcome adverse thermal effects that impact the device performance and reliability. Overheating of UWBG devices originates from the projected high power density operation and poor intrinsic thermal properties of AlxGa1-xN and ..beta..-Ga2O3. This Perspective delineates the need and process for the "electro-thermal co-design" of laterally configured UWBG electronic devices and provides a comprehensive review of current state-of-the-art thermal characterization methods, device thermal modeling practices, and both device- and package-level thermal management solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High precision control of laser energy for laser–matter interaction studies

Precise, highly reproducible control of the laser energy is required for high confidence laser–matter interaction research such as in dynamic compression science and high energy density physics. The energy must be adjustable without affecting the pulse shape (time varying intensity) or beam smoothness. We have developed a convenient two-stage energy tuning method for a nominal 100 J, 351 nm (UV) laser. The energy is adjusted in 10 J (10%) increments by operating the laser at full energy and inserting a beam splitter in the laser output. As the splitter is located after the final frequency tripling optics, the UV pulse shape is unchanged. The energy is varied by substituting a splitter of different reflectivity. For finer 3 J (3%) increments, the infrared pulse is attenuated inside the laser before the final amplifier. This requires modest tuning to preserve the pulse shape. The demonstrated variation in shot-to-shot reproducibility is less than +/–2.5 J (5% of the full energy), irrespective of the laser output energy. These approaches can be adapted to most ~100 J class lasers. We describe these techniques and show two examples where they have elucidated the underlying physics in laser shock compression experiments. One used only the beam splitters to establish the pressure for melting in iron. The other combined both techniques to finely increment the peak stress (~2 GPa steps) in germanium to precisely determine the onset and completion of melting—including the melting kinetics. Furthermore, these unambiguous results would not be possible without the developments described here.

47 OTHER INSTRUMENTATION↗

Dual-polarization O-band silicon photonics transmitter with an integrated tunable laser, Mach-Zehnder modulators, and SOAs

Presented is an O-band silicon photonics dual-polarization coherent/IMDD modulator integrated with semiconductor optical amplifiers and tunable laser to enhance the short-reach link budget. The laser demonstrated output power >6 dBm and a <250 kHz linewidth over a 14 nm tuning range. Modulators paired with custom 64 Gbaud QPSK drivers exhibited improved analog link sensitivity compared to similar devices without integrated gain sections. They also demonstrated 53 Gbaud dual-polarization PAM4 operation when characterized with a linear driver and MaxLinear 100G/lane DSP board. Both optical links achieved BERs at the KP4-FEC threshold and overall transmitter assembly energy consumption <6.9 pJ/bit without any thermal control when at steady room temperatures.

Liu, Junqian (ORCID:0000000167337650)↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

In situ amplification of spin echoes within a kinetic inductance parametric amplifier

The use of superconducting microresonators together with quantum-limited Josephson parametric amplifiers has enhanced the sensitivity of pulsed electron spin resonance (ESR) measurements by more than four orders of magnitude. So far, the microwave resonators and amplifiers have been designed as separate components due to the incompatibility of Josephson junction–based devices with magnetic fields. This has produced complex spectrometers and raised technical barriers toward adoption of the technique. Here, we circumvent this issue by coupling an ensemble of spins directly to a weakly nonlinear and magnetic field–resilient superconducting microwave resonator. We perform pulsed ESR measurements with a 1-pL mode volume containing 6 × 10 7 spins and amplify the resulting signals within the device. When considering only those spins that contribute to the detected signals, we find a sensitivity of 2.8 x 10 3 spins / $\sqrt{Hz}$ for a Hahn echo sequence at a temperature of 400 mK. In situ amplification is demonstrated at fields up to 254 mT, highlighting the technique’s potential for application under conventional ESR operating conditions.

42 ENGINEERING↗

Josephson Traveling Wave Parametric Amplifiers to Enable Future Neutrino Mass Measurements

Technologies for “quantum sensing" have the promise of dramatically improved sensitivity in some experiments that explore nuclear physics at the boundaries of our current knowledge. In particular, the Josephson Traveling Wave Parametric Amplifier (JTWPA) could enable future experiments such as Project 8 that use Cyclotron Radiation Emission Spectroscopy (CRES) to measure the absolute neutrino mass scale in tritium beta decays. CRES consists of detecting a signal of approximately one femtowatt of power radiated by electrons trapped in a 1-T magnetic field. The frequency of that radiation, around 27 GHz for a tritium endpoint electron, is inversely proportional to the electron energy. One of the significant challenges of a CRES experiment is the detection of minimal signal power levels. State-of-the-art transistor-based technologies will not likely achieve sufficient signal-to-noise ratio (SNR) in a competitive neutrino mass experiment. However, emerging quantum technologies have been demonstrated to operate at the fundamental lower limits of noise permitted by the laws of quantum mechanics. Of those technologies, JTWPAs appear to satisfy future performance needs with speed gain, bandwidth, and very low noise. We propose to bring together a group of neutrino physicists, experts in the needs of future neutrino mass measurements, with leaders in the field of quantum information science and JTWPA technology to develop JTWPAs appropriate for neutrino mass measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

Solution-Processed Temperature-Adaptive Radiative Paint as a Thermal Imaging Sensitizer

Thermography detects mid-infrared radiation from surfaces based on the Stefan-Boltzmann law, mapping surface temperatures and potentially revealing subsurface thermal activity. Recent developments offer an alternative strategy to traditional camera-based improvements: a thermal imaging sensitizer (TIS) coating whose emissivity increases sharply with local temperature, amplifying small thermal variations into high-contrast signals. Existing TIS structures are nanofabricated solid membranes and face significant challenges in fabrication complexity. Here, in this study, we present a solution-processed, liquid form of TIS, termed temperature-adaptive radiative paint (TARP), to address these limitations. TARP offers drastically reduced fabrication costs, scalability to large areas, applicability to curved surfaces, and an extended operating temperature range, while maintaining the function of temperature amplification. Application of TARP enhances small temperature contrast by more than 3 times, substantially improving ambient thermography and enabling broader applications such as detection of structural defects and hot spots in electronic components.

paint↗

Understanding Multi-Ion Transport Mechanisms in Bipolar Membranes

Bipolar membranes (BPMs) have the potential to become critical components in electrochemical devices for a variety of electrolysis and electrosynthesis applications. Because they can operate under large pH gradients, BPMs enable favorable environments for electrocatalysis at the individual electrodes. Critical to the implementation of BPMs in these devices is understanding the kinetics of water dissociation that occurs within the BPM as well as the co- and counter-ion crossover through the BPM, which both present significant obstacles to developing efficient and stable BPM-electrolyzers. In this study, a continuum model of multi-ion transport in a BPM is developed and fit to experimental data. Specifically, concentration profiles are determined for all ionic species, and the importance of a water-dissociation catalyst is demonstrated. The model describes internal concentration polarization and co- and counter-ion crossover in BPMs, determining the mode of transport for ions within the BPM and revealing the significance of salt-ion crossover when operated with pH gradients relevant to electrolysis and electrosynthesis. Lastly, a sensitivity analysis reveals that the performance and lifetime of BPMs can be improved substantially by using of thinner dissociation catalysts, managing water transport, modulating the thickness of the individual layers in the BPM to control salt-ion crossover, and increasing the ion-exchange capacity of the ion-exchange layers in order to amplify the water-dissociation kinetics at the interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of amplification and absorption of a THz quantum-cascade metasurface free-space amplifier

An active amplifying metasurface based on a quantum-cascade gain material at 2.7 THz is studied. The metasurface is first evaluated as the active component of an external cavity laser with excellent beam quality and frequency tunability from 2.55–2.8 THz. Amplification and absorption of the metasurface alone are then separately measured at a single frequency using a probe signal from a CO 2 -pumped gas laser operating at 2.743 THz. The metasurface reflectance vs bias is measured and compared with expectations from non-equilibrium Green’s function simulations of the quantum-cascade gain material and FEM simulations of the metasurface reflectance. A peak amplification on the order of 0.3 dB is measured. Design strategies are discussed for increasing single-reflection amplification (upward of 10 dB) and reducing power dissipation. Further increased amplification could be achieved by cascading multiple metasurfaces.

Curwen, Christopher A.↗

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PVInsight (Final Technical Report)

Data generated from real-world photovoltaic (PV) systems represent significant opportunities for the industry–from digital operations and maintenance to real-time planning and forecasting. However, these data also come with substantial, unique challenges. A particular challenge is the analysis of unlabeled PV performance data, which we define as time-series measurements of real power production (or sometimes current or voltage) that do not have corresponding meteorological measurements (irradiance, temperature, etc.) or system configuration information (sometimes called system metadata). These challenges are amplified in the distributed rooftop sector, in which data quality, completeness, and metadata can be very poor.

14 SOLAR ENERGY↗

1016516285-AA - Handling Frame Assembly Table Structural and Seismic Analysis

Within the NIF (National Ignition Facility) sustainment project, LLNL is replacing all 1,728 blast shields with new ones. Before the new blast shield glass can be installed on NIF, it must pass through the AMOL (Amplifier Main Optics Loop). The AMOL process involves cleaning and coating the glass, assembling it into a Line Replaceable Unit (LRU), and performing testing and inspection. This work will be conducted in the OPFX cleanroom facility (Building 391, Room 1250) and requires several pieces of custom equipment. One key piece of equipment within the loop is the Handling Frame Assembly Table (see Figure 1.1). Its purpose is to assist operators in installing the blast shield glass into handling frames (1014442709) (see Figure 1.2). The table is also used to store handling frame assembly components. The primary components stored are the L-frames (1015208271), which are kept in a drawer underneath the table (see Figure 1.3). The purpose of this safety note is to ensure that the system does not pose a risk of injury to personnel during a seismic event. The system owner is OMST Engineering & Maintenance.

42 ENGINEERING↗

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗